Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Federica Ettori is active.

Publication


Featured researches published by Federica Ettori.


Circulation | 2011

Incidence and Predictors of Early and Late Mortality After Transcatheter Aortic Valve Implantation in 663 Patients With Severe Aortic Stenosis

Corrado Tamburino; Davide Capodanno; Angelo Ramondo; Anna Sonia Petronio; Federica Ettori; Gennaro Santoro; Silvio Klugmann; Francesco Bedogni; Francesco Maisano; Antonio Marzocchi; Arnaldo Poli; David Antoniucci; Massimo Napodano; Marco De Carlo; Claudia Fiorina; Gian Paolo Ussia

Background— There is a lack of information on the incidence and predictors of early mortality at 30 days and late mortality between 30 days and 1 year after transcatheter aortic valve implantation (TAVI) with the self-expanding CoreValve Revalving prosthesis. Methods and Results— A total of 663 consecutive patients (mean age 81.0±7.3 years) underwent TAVI with the third generation 18-Fr CoreValve device in 14 centers. Procedural success and intraprocedural mortality were 98% and 0.9%, respectively. The cumulative incidences of mortality were 5.4% at 30 days, 12.2% at 6 months, and 15.0% at 1 year. The incidence density of mortality was 12.3 per 100 person-year of observation. Clinical and hemodynamic benefits observed acutely after TAVI were sustained at 1 year. Paravalvular leakages were trace to mild in the majority of cases. Conversion to open heart surgery (odds ratio [OR] 38.68), cardiac tamponade (OR 10.97), major access site complications (OR 8.47), left ventricular ejection fraction <40% (OR 3.51), prior balloon valvuloplasty (OR 2.87), and diabetes mellitus (OR 2.66) were independent predictors of mortality at 30 days, whereas prior stroke (hazard ratio [HR] 5.47), postprocedural paravalvular leak ≥2+ (HR 3.79), prior acute pulmonary edema (HR 2.70), and chronic kidney disease (HR 2.53) were independent predictors of mortality between 30 days and 1 year. Conclusions— Benefit of TAVI with the CoreValve Revalving System is maintained over time up to 1 year, with acceptable mortality rates at various time points. Although procedural complications are strongly associated with early mortality at 30 days, comorbidities and postprocedural paravalvular aortic regurgitation ≥2+ mainly impact late outcomes between 30 days and 1 year.


Journal of the American College of Cardiology | 2003

Immediate results and one-year clinical outcome after percutaneous coronary interventions in chronic total occlusions: Data from a multicenter, prospective, observational study (TOAST-GISE)

Zoran Olivari; Paolo Rubartelli; Federico Piscione; Federica Ettori; Alessandro Fontanelli; Luigi Salemme; Corinna Giachero; Carlo Di Mario; Gabriele Gabrielli; Leonardo Spedicato; Francesco Bedogni

OBJECTIVES We sought to investigate the success rate and the acute and 12-month clinical outcome of percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) in the contemporary era. BACKGROUND The technique of PCI involving CTO has improved over time. However, limited data on acute and follow-up results in patients treated with PCI on CTO in recent years are available. METHODS Four hundred nineteen consecutive patients scheduled for PCI of CTO of > or =30 days of duration were enrolled in 29 centers; 390 CTOs were confirmed in 376 patients in an independent core laboratory. The end points were technical and procedural success, in-hospital and 12-month major adverse cardiac events (MACE) occurrence, and 12-month symptomatic status. RESULTS Technical and procedural success was obtained in 77.2% and 73.3% of lesions, respectively. In-hospital major adverse cardiac events occurred in 5.1% of patients. Multivariate analysis identified CTO length >15 mm or not measurable, moderate to severe calcifications, duration > or =180 days, and multivessel disease as significant predictors of PCI failure. At 12 months, patients with a successful procedure experienced a lower incidence of cardiac deaths or myocardial infarction (1.05% vs. 7.23%, p = 0.005), a reduced need for coronary artery bypass surgery (2.45% vs. 15.7%, p < 0.0001), and were more frequently free of angina (88.7% vs. 75.0%, p = 0.008) compared with patients who had an unsuccessful procedure. CONCLUSIONS Successful PCI was achieved in a high percentage of CTOs with a low incidence of complications. At one-year follow-up, patients with successful PCI of a CTO had a significantly better clinical outcome than those whose PCI was unsuccessful.


European Heart Journal | 2012

Transcatheter aortic valve implantation: 3-year outcomes of self-expanding CoreValve prosthesis

Gian Paolo Ussia; Marco Barbanti; Anna Sonia Petronio; Giuseppe Tarantini; Federica Ettori; Antonio Colombo; Roberto Violini; Angelo Ramondo; Gennaro Santoro; Silvio Klugmann; Francesco Bedogni; Francesco Maisano; Antonio Marzocchi; Arnaldo Poli; Marco De Carlo; Massimo Napodano; Claudia Fiorina; Federico De Marco; David Antoniucci; Emanuela de Cillis; Davide Capodanno; Corrado Tamburino

AIMS The paucity of evidences about the long-term durability of currently available transcatheter prostheses is one of the main issues of transcatheter aortic valve implantation (TAVI). We sought to assess 3-year clinical and echocardiographic outcomes of patients undergoing TAVI with the third generation CoreValve prosthesis (Medtronic Incorporation, MN, USA). METHODS AND RESULTS From the Italian CoreValve registry, 181 who underwent TAVI from June 2007 to August 2008 and eligible for 3-year follow-up were analysed. All outcomes were defined according to the Valve Academic Research Consortium. All-cause mortality at 1, 2, and 3 years was 23.6, 30.3, and 34.8%, respectively. Cardiovascular death at 1, 2, and 3 years was 11.2, 12.1, and 13.5%, respectively. The actuarial survival free from a composite of death, major stroke, myocardial infarction, and life-threatening bleeding was 69.6% at 1 year, 63.5% at 2 years, and 59.7% at 3 years. Patients with renal insufficiency had a higher mortality at 3-year follow-up (49.0 vs. 29.2%, P = 0.007); moreover, patients experiencing post-procedural major or life-threatening bleeding had a higher rate of mortality already seen at 30 days (21.6 vs. 2.8%; P < 0.001) and this result was sustained at 3-year follow-up (62.2 vs. 27.7%; P < 0.001). Mean pressure gradients decreased from 52.2 ± 18.1 mmHg (pre-TAVI) to 10.3 ± 3.1 mmHg (1-year post-TAVI) (P < 0.001); aortic valve area increased from 0.6 ± 0.2 cm(2) (pre-TAVI) to 1.8 ± 0.4 cm(2) (1-year post-TAVI); these results remained stable over the 3 years of follow-up. Paravalvular leak was observed in the majority of patients. There were no cases of progression to moderate or severe regurgitation. No cases of structural valve deterioration were observed. CONCLUSION This multicentre study demonstrates that TAVI with the 18-Fr CoreValve ReValving System is associated with sustained clinical and functional cardiovascular benefits in high-risk patients with symptomatic aortic stenosis up to 3-year follow-up. Non-cardiac causes accounted for the majority of deaths at follow-up.


Circulation-cardiovascular Interventions | 2010

Safety and Efficacy of the Subclavian Approach for Transcatheter Aortic Valve Implantation With the CoreValve Revalving System

Anna Sonia Petronio; Marco De Carlo; Francesco Bedogni; Antonio Marzocchi; Silvio Klugmann; Francesco Maisano; Angelo Ramondo; Gian Paolo Ussia; Federica Ettori; Arnaldo Poli; Nedy Brambilla; Francesco Saia; Federico De Marco; Antonio Colombo

Background—Transcatheter aortic valve implantation (TAVI) is a new option for patients with severe aortic stenosis at high surgical risk. The standard retrograde approach through the femoral artery is contraindicated in case of unfavorable iliofemoral anatomy or extensive disease. In these patients, a trans-subclavian approach may be feasible. Methods and Results—Between June 2007 and July 2009, TAVI with the CoreValve bioprosthesis (Medtronic, Minneapolis, Minn) was performed in 514 consecutive patients at 13 Italian hospitals, using the subclavian approach in 54 cases. The median logistic EuroSCORE was significantly higher in the subclavian (19.4; interquartile range, 12.5 to 29.8) versus femoral group (25.3; interquartile range, 15.1 to 36.6) (P=0.03), as well as the rate of comorbidities. Procedural success was obtained in 100% versus 98.4% of the subclavian versus femoral groups, respectively (P=0.62), with intraprocedural mortality of 0% versus 0.9% (P=1.00). The most common in-hospital complications were a new left bundle-branch block (22.4%) and the need for pacemaker (16.3%). No specific complications for the subclavian access (vessel rupture, vertebral or internal mammary ischemia) were reported. The learning curve for the subclavian approach led to a wider use of local anesthesia. Thirty-day mortality was 0% versus 6.1% in the subclavian versus femoral groups, respectively (P=0.13). Six-month mortality rate was 9.4% versus 15.8% (P=0.44), whereas valve-related adverse events were 13.6% versus 13.9% (P=0.79). Conclusions—TAVI through the subclavian approach appeared feasible and safe, with excellent procedural success and low in-hospital complication rates. This new technique allows patients with contraindications to the femoral approach to be treated with TAVI.


American Heart Journal | 2009

Emergency percutaneous coronary intervention in patients with ST-elevation myocardial infarction complicated by out-of-hospital cardiac arrest: Early and medium-term outcome

Corrado Lettieri; Stefano Savonitto; Stefano De Servi; Giulio Guagliumi; Guido Belli; Alessandra Repetto; Emanuela Piccaluga; Alessandro Politi; Federica Ettori; Battistina Castiglioni; Franco Fabbiocchi; Nicoletta De Cesare; Giuseppe Sangiorgi; Giuseppe Musumeci; Marco Onofri; Maurizio D'Urbano; Salvatore Pirelli; Roberto Zanini; Silvio Klugmann

BACKGROUND The role of emergency reperfusion therapy in patients with ST-elevation myocardial infarction (STEMI) resuscitated after an out-of-hospital cardiac arrest (OHCA) has not been clearly established yet. The aim of this study was to evaluate the in-hospital and postdischarge outcomes of STEMI patients surviving OHCA and undergoing emergency angioplasty (percutaneous coronary intervention [PCI]) within an established regional network. METHODS We prospectively collected data on 2,617 consecutive patients with STEMI treated with emergency PCI in 2005; in-hospital and 6-month outcomes of 99 patients who had experienced OHCA were compared with those of 2,518 patients without OHCA. The OHCA patients also underwent a cerebral performance evaluation after 12 months. RESULTS OHCA patients were at higher clinical risk at presentation (cardiogenic shock 26% vs 5%, P < .0001). Percutaneous coronary intervention was successful in 80% of the OHCA and 89% of the non-OHCA patients (P = NS). In-hospital mortality rates were 22% and 3%, respectively (P < .0001). Independent predictors of in-hospital mortality among OHCA patients were longer delay between the call to the emergency medical system and the start of cardiopulmonary resuscitation (odds ratio [OR] 3.5, P = .03), nonshockable initial rhythms (OR 10.5, P = .002), cardiogenic shock (OR 3.05, P = .035), and a Glasgow Coma Scale score of 3 on admission (OR 2.9, P = .032). The 6-month composite rate of death, myocardial infarction, and revascularization among OHCA patients surviving the acute phase was comparable to that of non-OHCA patients (16% vs 13.9%, P = NS), and 87% of them showed a favorable neurologic recovery after 1 year. CONCLUSIONS Resuscitated OHCA patients undergoing emergency PCI for STEMI have worse clinical presentation and higher in-hospital mortality compared to those without OHCA. However, subsequent cardiac events are similar, and neurologic recovery is more favorable than reported in most previous series.


Jacc-cardiovascular Interventions | 2015

5-Year Outcomes After Transcatheter Aortic Valve Implantation With CoreValve Prosthesis.

Marco Barbanti; Anna Sonia Petronio; Federica Ettori; Azeem Latib; Francesco Bedogni; Federico De Marco; Arnaldo Poli; Carla Boschetti; Marco De Carlo; Claudia Fiorina; Antonio Colombo; Nedy Brambilla; Giuseppe Bruschi; Paola Martina; Claudia Pandolfi; Cristina Giannini; Salvatore Curello; Carmelo Sgroi; Simona Gulino; Martina Patanè; Yohei Ohno; Claudia Tamburino; Guilherme F. Attizzani; Sebastiano Immè; Alessandra Gentili; Corrado Tamburino

OBJECTIVES The purpose of this analysis was to assess 5-year outcomes of transcatheter aortic valve implantation (TAVI) using the current technology of the self-expanding CoreValve prosthesis (Medtronic Inc., Minneapolis, Minnesota). BACKGROUND There is a paucity of evidence on long-term durability of currently available transcatheter heart valves. METHODS Starting in June 2007, all consecutive patients with severe aortic stenosis undergoing TAVI with the third-generation 18-F CoreValve device in 8 Italian centers were prospectively included in the ClinicalService Project. For the purposes of this study, we included only consecutive patients with 5-year follow-up data available (n = 353) treated from June 2007 to August 2009. All outcomes were reported according to VARC (Valve Academic Research Consortium)-1 criteria. RESULTS All-cause mortality rates at 1, 2, 3, 4, and 5 years were 21%, 29%, 38%, 48%, and 55.0%, respectively. Cardiovascular mortality rates at 1, 2, 3, 4, and 5 years were 10%, 14%, 19%, 23%, and 28.0%, respectively. The overall neurological event rate at 5 years was 7.5%, of which more than two-thirds occurred early after the procedure. During follow-up, there were 241 rehospitalizations for cardiovascular reasons in 164 (46%) patients. Among all rehospitalizations, acute heart failure was the most frequently reported (42.7%), followed by requirement of permanent pacemaker implantation (17.4%). On echocardiography, mean transaortic gradients decreased from 55.6 ± 16.8 mm Hg (pre-TAVI) to 12.8 ± 10.9 mm Hg (5-year post-TAVI) (p < 0.001). Late prosthesis failure occurred in 5 cases (1.4%); among these, redo TAVI was successfully carried out in 2 patients (0.6%) presenting with symptomatic prosthesis restenosis. The remaining 3 cases of prosthesis failure did not undergo further invasive interventions. Ten patients (2.8%) showed late mild stenosis with a mean transaortic gradient ranging from 20 to 40 mm Hg. No other cases of structural or nonstructural valvular deterioration were observed. Valve thrombosis or late valve embolization were not reported. CONCLUSIONS TAVI with the currently adopted CoreValve generation was associated with sustained clinical outcomes up to 5-year follow-up, with a low rate (1.4%) of significant prosthetic valve degeneration. The procedure appears to be an adequate and lasting resolution of aortic stenosis in selected high-risk patients.


Circulation | 2013

Clinical impact of persistent left bundle-branch block after transcatheter aortic valve implantation with CoreValve revalving system

Luca Testa; Azeem Latib; Federico De Marco; Marco De Carlo; Mauro Agnifili; Roberto Latini; Anna Sonia Petronio; Federica Ettori; Arnaldo Poli; Stefano De Servi; Angelo Ramondo; Massimo Napodano; S. Klugmann; Gian Paolo Ussia; Corrado Tamburino; Nedy Brambilla; Antonio Colombo; Francesco Bedogni

Background— Conduction disturbances are relatively common after transcatheter aortic valve implantation. Previous data demonstrated an adverse impact of persistent left bundle-branch block (LBBB) after surgical aortic valve replacement. It is unclear whether new-onset LBBB may also impact the prognosis of patients after transcatheter aortic valve implantation. Methods and Results— Among 1060 patients treated with a CoreValve Revalving System transcatheter aortic valve implantation between October 2007 and April 2011 in high-volume centers in Italy, we analyzed those without LBBB or pacemaker at admission (879 patients [82.9%]). We further excluded those who underwent permanent pacemaker implantation within 48 hours after the procedure (61 patients [7%]), for a final study population of 818 patients. Among them, 224 patients (group A; 27.4%) developed a persistent LBBB and the remaining 594 (group B; 72.6%) did not. Clinical characteristics were similar between groups. A low implantation was significantly more frequent in group A (15% versus 9.8%, P=0.02). No patients were censored before 1 year (median follow-up period 438 days, interquartile range 174–798 days). Survival analyses and inherent log-rank tests showed that LBBB was not associated with higher all-cause mortality, cardiac mortality, or hospitalization for heart failure at 30 days or 1 year. At 30 days, but not at 1 year, group A had a significantly higher rate of pacemaker implantation. Conclusions— In this registry of high-volume centers, persistent LBBB after CoreValve Revalving System transcatheter aortic valve implantation showed no effect on hard end points. On the other hand, LBBB was associated with a higher short-term rate of pacemaker implantation.


Journal of the American College of Cardiology | 2011

The Valve-in-Valve Technique for Treatment of Aortic Bioprosthesis Malposition: An Analysis of Incidence and 1-Year Clinical Outcomes From the Italian CoreValve Registry

Gian Paolo Ussia; Marco Barbanti; Angelo Ramondo; Anna Sonia Petronio; Federica Ettori; Gennaro Santoro; Silvio Klugmann; Francesco Bedogni; Francesco Maisano; Antonio Marzocchi; Arnaldo Poli; Massimo Napodano; Corrado Tamburino

OBJECTIVES We appraised the incidence and clinical outcomes of patients who were treated with the valve-in-valve (ViV) technique for hemodynamically destabilizing paraprosthetic leak (PPL). BACKGROUND Device malpositioning causing severe PPL after transcatheter aortic valve implantation is not an uncommon finding. It occurs after release of the prosthesis, leading to hemodynamic compromise. It can be managed successfully in selected cases with implantation of a second device inside the malpositioned primary prosthesis (ViV technique). METHODS Consecutive patients (n = 663) who underwent transcatheter aortic valve implantation with the 18-F CoreValve ReValving System (Medtronic, Inc., Minneapolis, Minnesota) at 14 centers across Italy were included in this prospective web-based registry. We identified patients treated with the ViV technique for severe PPL and analyzed their clinical and echocardiographic outcomes. Primary end points were major adverse cerebrovascular and cardiac events and prosthesis performance at the 30-day and midterm follow-up. RESULTS Overall procedural success was obtained in 650 patients (98.0%). The ViV technique was used in 24 (3.6%) of 663 patients. The 30-day major adverse cerebrovascular and cardiac event rates were 7.0% and 0% in patients undergoing the standard procedure and ViV technique, respectively (p = 0.185); the mortality rates were 5.6% versus 0% in patients undergoing the standard procedure and ViV technique, respectively (p = 0.238). There was an improvement in the mean transaortic gradient in all patients without significant difference between the 2 groups (from 52.1 ± 17.1 mm Hg and 45.4 ± 14.8 mm Hg [p = 0.060] to 10.1 ± 4.2 mm Hg and 10.5 ± 5.2 mm Hg, respectively [p = 0.838]). At 12 months, the major adverse cerebrovascular and cardiac event rates in the standard procedure and ViV technique groups were 4.5% and 14.1%, respectively (p = 0.158), and the mortality rates were 4.5% versus 13.7%, respectively (p = 0.230). CONCLUSIONS This large, multicenter registry provides important information about the feasibility, safety, and efficacy of the ViV technique with the third-generation CoreValve ReValving System. The clinical and echocardiographic end points compare favorably with those of patients undergoing the standard procedure. The ViV technique offers a viable therapeutic option in patients with acute significant PPL without recourse to emergent surgery.


Journal of the American College of Cardiology | 2012

2-year results of CoreValve implantation through the subclavian access: a propensity-matched comparison with the femoral access.

Anna Sonia Petronio; Marco De Carlo; Francesco Bedogni; Francesco Maisano; Federica Ettori; Silvio Klugmann; Arnaldo Poli; Antonio Marzocchi; Gennaro Santoro; Massimo Napodano; Gian Paolo Ussia; Cristina Giannini; Nedy Brambilla; Antonio Colombo

OBJECTIVES The goal of this study was to assess the procedural and 2-year results of the subclavian approach for transcatheter aortic valve implantation (TAVI) compared with those of the femoral approach by using propensity-matched analysis. BACKGROUND The subclavian approach with the CoreValve prosthesis (Medtronic, Inc., Minneapolis, Minnesota) represents an interesting opportunity when the femoral access is unfeasible. METHODS All consecutive patients enrolled in the Italian CoreValve Registry who underwent TAVI with the subclavian approach were included. Propensity score analysis was used to identify a matching group of patients undergoing femoral TAVI. RESULTS Subclavian approach was used in 141 patients (61% men; median age 83 years; median logistic European System for Cardiac Operative Risk Evaluation score 23.7%). The femoral group of 141 patients was matched for baseline clinical characteristics, except for peripheral artery disease. The 2 groups showed similar procedural success (97.9% vs. 96.5%; p = 0.47), major vascular complications (5.0% vs. 7.8%; p = 0.33), life-threatening bleeding events (7.8% vs. 5.7%; p = 0.48), and combined safety endpoint (19.9% vs. 25.5%; p = 0.26). The subclavian group showed lower rates of acute kidney injury/stage 3 (4.3% vs. 9.9%; p = 0.02), of minor vascular complications at the 18-F sheath insertion site (2.1% vs. 11.3%; p = 0.003), and of all types of bleeding events related to vascular complications. Survival at 2 years was 74.0 ± 4.0% in the subclavian group compared with 73.7 ± 3.9% in the femoral group (p = 0.78). The 2-year freedom from cardiovascular death was 87.2 ± 3.1% versus 88.7 ± 2.8% in the subclavian versus femoral group, respectively (p = 0.84). CONCLUSIONS The subclavian approach for TAVI is safe and feasible, with procedural and medium-term results similar to the femoral approach. Subclavian access should be considered a valid option not only when the femoral approach is impossible but also when it is difficult, albeit feasible.


Circulation | 2013

Interplay Between Mitral Regurgitation and Transcatheter Aortic Valve Replacement With the CoreValve Revalving System A Multicenter Registry

Francesco Bedogni; Azeem Latib; Federico De Marco; Mauro Agnifili; Jacopo Oreglia; Samuele Pizzocri; Roberto Latini; Stefania Lanotte; Anna Sonia Petronio; Marco De Carlo; Federica Ettori; Claudia Fiorina; Arnaldo Poli; Silvia Cirri; Stefano De Servi; Angelo Ramondo; Giuseppe Tarantini; Antonio Marzocchi; Rosario Fiorilli; Silvio Klugmann; Gian Paolo Ussia; Corrado Tamburino; Francesco Maisano; Nedy Brambilla; Antonio Colombo; Luca Testa

Background— Little is known of the prognostic significance of mitral regurgitation (MR) on transcatheter aortic valve replacement (TAVR), the impact of TAVR on MR severity, and the variables associated with possible post-TAVR improvement in MR. We evaluated these issues in a multicenter registry of patients undergoing CoreValve Revalving System–TAVR. Methods and Results— Among 1007 consecutive patients, 670 (66.5%), 243 (24.1%), and 94 (9.3%) presented with no/mild, moderate, and severe MR, respectively. At 1 month after TAVR, patients with severe or moderate MR showed comparable mortality rates (odds ratio, 1.1; 95% confidence interval [95% CI], 0.7–1.55; P=0.2), but both were significantly higher compared with patients with mild/no MR (odds ratio, 2.2; 95% CI, 1.78–3.28; P<0.001; and odds ratio, 1.9; 95% CI, 1.1–3.3; P=0.02, respectively). One-year mortality was also similar between patients with severe and those with moderate MR (hazard ratio, 1.4; 95% CI, 0.94–2.4; P=0.06) and still significantly higher compared with patients with mild/no MR (hazard ratio, 1.7; 95% CI, 1.2–3.41; P<0.001; and hazard ratio, 1.4; 95% CI, 1.2–2.2; P=0.03, respectively). Severe pulmonary hypertension, atrial fibrillation, and MR more than mild, but not an improvement of ≥1 grade in MR severity, were independent predictors of mortality at 1 year. At 1 year, an improved MR was observed in 47% and 35% of patients with severe and moderate MR, respectively. The rate of low implantation was consistent across groups with improved, unchanged, or worsened MR. A functional type of MR and the absence of severe pulmonary hypertension and atrial fibrillation independently predicted the improvement in MR severity. Conclusions— Baseline MR greater than mild is associated with higher mortality after CoreValve Revalving System–TAVR. A significant improvement in MR was more likely in patients with functional MR and without severe pulmonary hypertension or atrial fibrillation. The improvement in MR did not independently predict mortality.

Collaboration


Dive into the Federica Ettori's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Francesco Bedogni

Vita-Salute San Raffaele University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Antonio Colombo

Vita-Salute San Raffaele University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Nedy Brambilla

Royal North Shore Hospital

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge