Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Francesco Merlini is active.

Publication


Featured researches published by Francesco Merlini.


British Journal of Ophthalmology | 2013

The Argus II epiretinal prosthesis system allows letter and word reading and long-term function in patients with profound vision loss

Lyndon da Cruz; Brian Coley; Jessy Dorn; Francesco Merlini; Eugene Filley; Punita Christopher; Fred K. Chen; Varalakshmi Wuyyuru; José Sahel; Paulo E. Stanga; Mark S. Humayun; Robert J. Greenberg; Gislin Dagnelie

Background Retinal prosthesis systems (RPS) are a novel treatment for profound vision loss in outer retinal dystrophies. Ideal prostheses would offer stable, long-term retinal stimulation and reproducible spatial resolution in a portable form appropriate for daily life. Methods We report a prospective, internally controlled, multicentre trial of the Argus II system. Twenty-eight subjects with light perception vision received a retinal implant. Controlled, closed-group, forced-choice letter identification, and, open-choice two-, three- and four-letter word identification tests were carried out. Results The mean±SD percentage correct letter identification for 21 subjects tested were: letters L, T, E, J, F, H, I, U, 72.3±24.6% system on and 17.7±12.9% system off; letters A, Z, Q, V, N, W, O, C, D, M, 55.0±27.4% system on and 11.8%±10.7% system off, and letters K, R, G, X, B, Y, S, P, 51.7±28.9% system on and 15.3±7.4% system off. (p<0.001 for all groups). A subgroup of six subjects was able to consistently read letters of reduced size, the smallest measuring 0.9 cm (1.7°) at 30 cm, and four subjects correctly identify unrehearsed two-, three- and four-letter words. Average implant duration was 19.9 months. Conclusions Multiple blind subjects fitted with the Argus II system consistently identified letters and words using the device, indicating reproducible spatial resolution. This, in combination with stable, long-term function, represents significant progress in the evolution of artificial sight.


Investigative Ophthalmology & Visual Science | 2010

Patients Blinded by Outer Retinal Dystrophies Are Able to Identify Letters Using the Argus TM II Retinal Prosthesis System

Lyndon daCruz; Brian Coley; P. Christopher; Francesco Merlini; Varalakshmi Wuyyuru; José-Alain Sahel; Paulo E. Stanga; Eugene Filley; Gislin Dagnelie


Archive | 2012

Face Detection, Tracking, and Recognition for a Visual Prosthesis

Neil Hamilton Talbot; Jerry Ok; Robert J. Greenberg; Gregoire Cosendai; Brian V. Mech; Avraham I. Caspi; Fatima Anaflous; Francesco Merlini; Kelly H. Mcclure


Investigative Ophthalmology & Visual Science | 2013

Face Detection using the Argus® II Retinal Prosthesis System

Paulo E. Stanga; José Sahel; Saddek Mohand-Said; Lyndon daCruz; Avi Caspi; Francesco Merlini; Robert J. Greenberg


Investigative Ophthalmology & Visual Science | 2012

Patients blinded by outer retinal dystrophies are able to perceive simultaneous colors using the Argus® II Retinal Prosthesis System

Paulo E. Stanga; José Sahel; Lyndon daCruz; Farhad Hafezi; Francesco Merlini; Brian Coley; Robert J. Greenberg


Investigative Ophthalmology & Visual Science | 2012

Subjects Blinded By Outer Retinal Dystrophies Are Able To Recognize Outlined Shapes Using The Argus® Ii Retinal Prosthesis System: A Comparison With The Full Shapes Recognition Task

Lyndon daCruz; Francesco Merlini; Maura Arsiero; Fatima Anaflous; Avi Caspi; José Sahel; Paulo E. Stanga; Farhad Hafezi; Robert J. Greenberg


Investigative Ophthalmology & Visual Science | 2011

Patients Blinded By Outer Retinal Dystrophies Are Able To Perceive Color Using The ArgusTm II Retinal Prosthesis System

Paulo E. Stanga; Farhad Hafezi; José Sahel; Lyndon daCruz; Francesco Merlini; Brian Coley; Robert J. Greenberg


Investigative Ophthalmology & Visual Science | 2014

The use of Argus® II Retinal Prosthesis to Identify Common Objects in Blind Subjects with Outer Retinal Dystrophies

Yvonne Hsu-Lin Luo; Joe Zhong; Francesco Merlini; Fatima Anaflous; Maura Arsiero; Paulo E. Stanga; Lyndon da Cruz


Investigative Ophthalmology & Visual Science | 2010

Initial Word Recognition Results With the ArgusTM II Retinal Prosthesis

Paulo E. Stanga; Brian Coley; Francesco Merlini; Susmito Biswas; George S. Turner; Robert J. Greenberg


Investigative Ophthalmology & Visual Science | 2011

Comparison Of Etdrs, Landolt C, And Grating Visual Acuity Tests Between Sighted Volunteers Using A Pixelized Image Simulator And Blind Subjects Implanted With The ArgusTm Ii Retinal Prosthesis

Saddek Mohand-Said; Avi Caspi; Francesco Merlini; Brian Coley; Jessy Dorn; Gregoire Cosendai; Robert J. Greenberg

Collaboration


Dive into the Francesco Merlini's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Paulo E. Stanga

Manchester Royal Eye Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Farhad Hafezi

University of Southern California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Fatima Anaflous

École Polytechnique Fédérale de Lausanne

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Gregoire Cosendai

École Polytechnique Fédérale de Lausanne

View shared research outputs
Top Co-Authors

Avatar

Maura Arsiero

École Polytechnique Fédérale de Lausanne

View shared research outputs
Top Co-Authors

Avatar

Arup Roy

Johns Hopkins University

View shared research outputs
Researchain Logo
Decentralizing Knowledge