Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Francesco Pera is active.

Publication


Featured researches published by Francesco Pera.


Journal of Prosthetic Dentistry | 2008

Immediate function with fixed implant-supported maxillary dentures: A 12-month pilot study

Tiziano Tealdo; Marco Bevilacqua; Francesco Pera; Maria Menini; Giambattista Ravera; Carl Drago; Paolo Pera

STATEMENT OF PROBLEM Immediate occlusal loading of dental implants in the edentulous mandible has proven to be an effective, reliable, and predictable procedure. There is little long-term data available on similar treatments in the edentulous maxilla. PURPOSE The purpose of this study was to evaluate the 12-month implant survival after immediate loading of 4 to 6 implants with fixed screw-retained prostheses in edentulous maxillae. MATERIAL AND METHODS Twenty-one patients, edentulous or with remaining teeth to be extracted in the maxilla, received 4 to 6 implants (n=111). The patients were restored with screw-retained fixed provisional prostheses supported by palladium-alloy frameworks within 24 hours after surgery. Insertion torques for implants were at least 40 Ncm. Implants, grouped as tapered or cylindrical screws, were placed in healed bone or extraction sockets. Implants were also classified as either vertical or off-angle. Definitive prostheses were placed after a mean healing time of 18 weeks. Radiographic examinations were made at the time of placement of provisional prostheses and 12 months later. Between-groups bone resorption was compared using 2-way ANOVA (alpha=.05). RESULTS The mean follow-up time for all of the patients was 20 months (range, 13 to 28 months). The cumulative implant survival rate at the 12-month follow-up visits (after surgery) was 92.8%; the prostheses survival rate was 100%. No significant differences were found between the survival of tapered or cylindrical screw-type implants placed in postextraction sockets versus those in healed edentulous sites or between vertical and off-angle placed implants. Eight implants failed during the first 3 months, 5 of which were the most distal implants. The mean reduction in marginal bone height over the 12-month observation period was 0.84 mm (CI 95%; 0.68-0.99 mm). CONCLUSIONS In this study with 12-month follow-up, 4 to 6 implants were sufficient to successfully support fixed implant screw-retained prostheses in the edentulous maxillae of 21 patients.


Journal of Dental Research | 2012

Tilted Implants in the Immediate Loading Rehabilitation of the Maxilla: A Systematic Review

Maria Menini; A. Signori; Tiziano Tealdo; Marco Bevilacqua; Francesco Pera; Giambattista Ravera; Paolo Pera

Tilted implants have been proposed as an alternative to traditional protocols in the rehabilitation of edentulous maxillae. The aim of this meta-analysis was to evaluate the outcomes of upright and tilted implants supporting full-arch fixed dentures for the immediate rehabilitation of edentulous maxillae, after at least 1 year of function. An electronic search of databases and a hand search of relevant journals in oral implantology were performed according to PRISMA guidelines through August, 2011. The literature search yielded 1,069 articles. Eleven articles were available for analysis. A total of 1,623 implants (778 tilted, 845 upright) were inserted into the maxillae of 324 patients. Seventeen tilted (2.19%) and 16 upright implants (1.89%) failed during the first year. No significant difference in failure rate was found between tilted and upright implants (p value = 0.52). Marginal bone level results were obtained from 6 studies. A non-significant mean difference between tilted and upright implants was found with regard to bone loss. Tilted implants demonstrated a favorable short-term prognosis in full-arch immediate loading rehabilitations of the maxillae. Randomized long-term trials are needed to better elucidate long-term success of tilted vs. upright-positioned implants.


Materials Science and Engineering: C | 2017

Biological and mechanical characterization of carbon fiber frameworks for dental implant applications

Maria Menini; Paolo Pesce; Francesco Pera; Fabrizio Barberis; Alberto Lagazzo; Ludovica Bertola; Paolo Pera

OBJECTIVES The aim of the present study was to investigate the biocompatibility and mechanical characteristics of dental implant frameworks made of carbon fiber composite. METHODS The biocompatibility of intact samples and fragments was evaluated by cell count and MTT test according to EN-ISO 10993-5:2009 directions. Destructive and non-destructive mechanical tests were performed in order to evaluate: porosity, static and dynamic elastic modulus of carbon fiber samples. These tests were conducted on different batches of samples manufactured by different dental technicians. The samples were evaluated by optical microscope and by SEM. A compression test was performed to compare complete implant-supported fixed dentures, provided with a metal or carbon fiber framework. RESULTS Carbon fiber intact and fragmented samples showed optimal biocompatibility. Manufacture technique strongly influenced the mechanical characteristics of fiber-reinforced composite materials. The implant-supported full-arch fixed denture provided with a carbon fiber framework, showed a yield strength comparable to the implant-supported full-arch fixed denture, provided with a metal framework. SIGNIFICANCE Carbon fiber-reinforced composites demonstrated optimal biocompatibility and mechanical characteristics. They appear suitable for the fabrication of frameworks for implant-supported full-arch dentures. Great attention must be paid to manufacture technique as it strongly affects the material mechanical characteristics.


Journal of Prosthodontics | 2016

A Luting Technique for Passive Fit of Implant-Supported Fixed Dentures

Maria Menini; Elena Dellepiane; Paolo Pera; Marco Bevilacqua; Paolo Pesce; Francesco Pera; Tiziano Tealdo

Several factors contribute to distortion of implant prostheses during fabrication and could prevent passive, accurate adaptation between implants and implant frameworks. The misfit between implants and restorative components may be significant and possibly lead to biologic or mechanical complications. The aim of this article is to describe a laboratory luting technique used to lute implant cylinders to metal frameworks in implant prostheses. This technique provides accurate, passive fits. According to this technique, titanium implant cylinders provided with corresponding external castable cylinders are used. Implant cylinders are screwed into the analogs in the master cast while the castable cylinders on top are splinted together using castable resin to realize a castable resin pattern. After casting, the framework is adjusted and cemented to the titanium cylinders on the master cast. Due to its ease and quickness of use and clinical efficiencies, this technique is deemed particularly useful in immediate loading rehabilitations.


Implant Dentistry | 2016

Analysis of Different Impression Techniques and Materials on Multiple Implants Through 3-Dimensional Laser Scanner.

Francesco Pera; Paolo Pesce; Marco Bevilacqua; Paolo Setti; Maria Menini

Objective:The aim of this study was to evaluate the accuracy of 7 different implant impression techniques for full-arch prostheses. Materials and Methods:A master cast simulating an edentulous arch with 4 implants was used. Seven impression techniques were tested: open tray with polyether Impregum (OTI); open tray with splint-polyether Impregum (OTSI); closed tray with polyether Impregum; open tray with polyether Ramitec; open tray with splint-polyether Ramitec; closed tray with polyether Ramitec (CTR); open tray with impression plaster (OTP). Five impressions of the master cast were taken for each technique using an impression simulator device. Casts were realized based on those impressions (n = 35). Median values of deviation from the master cast were recorded for each cast through a 3-dimensional laser scanner. Results:Only OTI (P = 0.028) and OTSI (P < 0.001) presented a statistically significant difference compared to the master cast. OTP (P = 0.99) and CTR (P = 0.10) showed median values of deviation close to zero (−0.001 and −0.003 mm, respectively). Conclusion:Stiff impression materials (such as plaster or rigid polyether) guarantee greater accuracy in cases of multiple implant impressions of patients with full-arch rehabilitations. Splinting of impression copings with acrylic resin did not improve accuracy.


Journal of Oral Rehabilitation | 2017

Carbon fibre versus metal framework in full-arch immediate loading rehabilitations of the maxilla - a cohort clinical study

Francesco Pera; Paolo Pesce; F. Solimano; Tiziano Tealdo; Paolo Pera; Maria Menini

Frameworks made of carbon fibre-reinforced composites (CFRC) seem to be a viable alternative to traditional metal frameworks in implant prosthodontics. CFRC provide stiffness, rigidity and optimal biocompatibility. The aim of the present prospective study was to compare carbon fibre frameworks versus metal frameworks used to rigidly splint implants in full-arch immediate loading rehabilitations. Forty-two patients (test group) were rehabilitated with full-arch immediate loading rehabilitations of the upper jaw (total: 170 implants) following the Columbus Bridge Protocol with four to six implants with distal tilted implants. All patients were treated with resin screw-retained full-arch prostheses endowed with carbon fibre frameworks. The mean follow-up was 22 months (range: 18-24). Differences in the absolute change of bone resorption over time between the two implant sides (mesial and distal) were assessed performing a Mann-Whitney U-test. The outcomes were statistically compared with those of patients rehabilitated following the same protocol but using metal frameworks (control group: 34 patients with 163 implants - data reported in Tealdo, Menini, Bevilacqua, Pera, Pesce, Signori, Pera, Int J Prosthodont, 27, 2014, 207). Ten implants failed in the control group (6·1%); none failed in the test group (P = 0·002). A statistically significant difference in the absolute change of bone resorption around the implants was found between the two groups (P = 0·004), with greater mean peri-implant bone resorption in the control group (1 mm) compared to the test group (0·8 mm). Carbon fibre frameworks may be considered as a viable alternative to the metal ones and showed less marginal bone loss around implants and a greater implant survival rate during the observation period.


Journal of Oral Rehabilitation | 2015

Gastric and masticatory performances in full-arch immediate loading rehabilitated patients

Paolo Pesce; Maria Menini; M. Furnari; Francesco Pera; Tiziano Tealdo; Paolo Pera

Full-arch immediate loading implant rehabilitations provide patients with compromised dentition an effective treatment to improve their aesthetic and function. Aim of this prospective cohort study was to investigate the correlation between masticatory ability and gastric emptying rates among these patients. Ten subjects (five men and five women) with compromised dentition were tested in two occasions: before treatment and 30 days after the immediate loading rehabilitation. Masticatory ability was evaluated using the sieves test, and the gastric half emptying time (T(1/2)) was assessed by means of the 13C-octanoic acid breath test. A statistically significant increment (P < 0.005) in masticatory ability was found only in reference to the particles smaller than or equal to 4.75 mm, whereas the gastric emptying rate showed a statistically significant reduction between pre- and post-treatment (P = 0.003). A moderate negative correlation (rho = 0.64, P = 0.048) between the percentage change in masticatory ability and the percentage change in gastric emptying rate was evidenced. Patients with compromised dentition rehabilitated with full-arch immediate implant prostheses present a significant improvement of the gastric process.


Journal of Prosthetic Dentistry | 2011

The influence of cantilever length and implant inclination on stress distribution in maxillary implant-supported fixed dentures.

Marco Bevilacqua; Tiziano Tealdo; Maria Menini; Francesco Pera; Alexei Mossolov; Carl J. Drago; Paolo Pera


Clinical Oral Implants Research | 2015

Brånemark Novum® immediate loading rehabilitation of edentulous mandibles: 11-year retrospective study

Tiziano Tealdo; Maria Menini; Marco Bevilacqua; Francesco Pera; Vanessa Capalbo; Paolo Pera


Dental Materials | 2014

Different framework materials for implant-supported prostheses: 3D finite element analysis

Maria Menini; Marco Bevilacqua; Francesco Pera; S. Bini; Tiziano Tealdo; Paolo Pera

Collaboration


Dive into the Francesco Pera's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge