Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Frank J. H. Gijsen is active.

Publication


Featured researches published by Frank J. H. Gijsen.


Nature Reviews Cardiology | 2005

The role of shear stress in the destabilization of vulnerable plaques and related therapeutic implications

Cornelis J. Slager; Jolanda J. Wentzel; Frank J. H. Gijsen; A. Thury; Ac van der Wal; Johannes A. Schaar; Patrick W. Serruys

American Heart Association type IV plaques consist of a lipid core covered by a fibrous cap, and develop at locations of eccentric low shear stress. Vascular remodeling initially preserves the lumen diameter while maintaining the low shear stress conditions that encourage plaque growth. When these plaques eventually start to intrude into the lumen, the shear stress in the area surrounding the plaque changes substantially, increasing tensile stress at the plaque shoulders and exacerbating fissuring and thrombosis. Local biologic effects induced by high shear stress can destabilize the cap, particularly on its upstream side, and turn it into a rupture-prone, vulnerable plaque. Tensile stress is the ultimate mechanical factor that precipitates rupture and atherothrombotic complications. The shear-stress-oriented view of plaque rupture has important therapeutic implications. In this review, we discuss the varying mechanobiologic mechanisms in the areas surrounding the plaque that might explain the otherwise paradoxical observations and unexpected outcomes of experimental therapies.


Stroke | 2007

Plaque Rupture in the Carotid Artery Is Localized at the High Shear Stress Region A Case Report

Harald C. Groen; Frank J. H. Gijsen; Aad van der Lugt; Marina S. Ferguson; Thomas S. Hatsukami; Anton F.W. van der Steen; Chun Yuan; Jolanda J. Wentzel

Background and Purpose— Cerebrovascular events are related to atherosclerotic disease in the carotid arteries and are frequently caused by rupture of a vulnerable plaque. These ruptures are often observed at the upstream region of the plaque, where the wall shear stress (WSS) is considered to be highest. High WSS is known for its influence on many processes affecting tissue regression. Until now, there have been no serial studies showing the relationship between plaque rupture and WSS. Summary of Case— We investigated a serial MRI data set of a 67-year-old woman with a plaque in the carotid artery at baseline and an ulcer at 10-month follow up. The lumen, plaque components (lipid/necrotic core, intraplaque hemorrhage), and ulcer were segmented and the lumen contours at baseline were used for WSS calculation. Correlation of the change in plaque composition with the WSS at baseline showed that the ulcer was generated exclusively at the high WSS location. Conclusions— In this serial MRI study, we found plaque ulceration at the high WSS location of a protruding plaque in the carotid artery. Our data suggest that high WSS influences plaque vulnerability and therefore may become a potential parameter for predicting future events.


Cardiovascular Research | 2012

Endothelial shear stress in the evolution of coronary atherosclerotic plaque and vascular remodelling: Current understanding and remaining questions

Jolanda J. Wentzel; Yiannis S. Chatzizisis; Frank J. H. Gijsen; George D. Giannoglou; Charles L. Feldman; Peter H. Stone

The heterogeneity of plaque formation, the vascular remodelling response to plaque formation, and the consequent phenotype of plaque instability attest to the extraordinarily complex pathobiology of plaque development and progression, culminating in different clinical coronary syndromes. Atherosclerotic plaques predominantly form in regions of low endothelial shear stress (ESS), whereas regions of moderate/physiological and high ESS are generally protected. Low ESS-induced compensatory expansive remodelling plays an important role in preserving lumen dimensions during plaque progression, but when the expansive remodelling becomes excessive promotes continued influx of lipids into the vessel wall, vulnerable plaque formation and potential precipitation of an acute coronary syndrome. Advanced plaques which start to encroach into the lumen experience high ESS at their most stenotic region, which appears to promote plaque destabilization. This review describes the role of ESS from early atherogenesis to early plaque formation, plaque progression to advanced high-risk stenotic or non-stenotic plaque, and plaque destabilization. The critical implication of the vascular remodelling response to plaque growth is also discussed. Current developments in technology to characterize local ESS and vascular remodelling in vivo may provide a rationale for innovative diagnostic and therapeutic strategies for coronary patients that aim to prevent clinical coronary syndromes.


Journal of Biomechanics | 2003

Shear stress, vascular remodeling and neointimal formation

Jolanda J. Wentzel; Frank J. H. Gijsen; Nikos Stergiopulos; Patrick W. Serruys; Cornelis J. Slager; Rob Krams

The role of shear stress in atherosclerosis has been well documented. However, its role in restenosis was underexposed. In this paper a novel in vivo measuring technique and several of its applications related to restenosis will be described. The technique consists of a combination of 3D reconstruction of blood vessels and computational fluid dynamics (CFD). The 3D imaging techniques use either of 3D intravascular ultrasound (IVUS) as a stand-alone technique or a fusion of biplane angiography and IVUS (ANGUS). CFD is applied in order to relate local shear stress distribution to the morphology of the vessel wall. In the applications of these techniques it will be demonstrated that shear stress plays a role in the prediction of neointimal formation in in-stent restenosis and in vascular remodeling after balloon angioplasty. Attempts to locally increase shear stress by a newly developed flow divider indicate that shear stress reduce in-stent neointimal formation by 50%.


American Journal of Physiology-heart and Circulatory Physiology | 2008

Strain distribution over plaques in human coronary arteries relates to shear stress

Frank J. H. Gijsen; Jolanda J. Wentzel; Attila Thury; Frits Mastik; Johannes A. Schaar; Johan C.H. Schuurbiers; Cornelis J. Slager; Wim J. van der Giessen; Pim J. de Feyter; Anton F.W. van der Steen; Patrick W. Serruys

Once plaques intrude into the lumen, the shear stress they are exposed to alters with hitherto unknown consequences for plaque composition. We investigated the relationship between shear stress and strain, a marker for plaque composition, in human coronary arteries. We imaged 31 plaques in coronary arteries with angiography and intravascular ultrasound. Computational fluid dynamics was used to obtain shear stress. Palpography was applied to measure strain. Each plaque was divided into four regions: upstream, throat, shoulder, and downstream. Average shear stress and strain were determined in each region. Shear stress in the upstream, shoulder, throat, and downstream region was 2.55+/-0.89, 2.07+/-0.98, 2.32+/-1.11, and 0.67+/-0.35 Pa, respectively. Shear stress in the downstream region was significantly lower. Strain in the downstream region was also significantly lower than the values in the other regions (0.23+/-0.08% vs. 0.48+/-0.15%, 0.43+/-0.17%, and 0.47+/-0.12%, for the upstream, shoulder, and throat regions, respectively). Pooling all regions, dividing shear stress per plaque into tertiles, and computing average strain showed a positive correlation; for low, medium, and high shear stress, strain was 0.23+/-0.10%, 0.40+/-0.15%, and 0.60+/-0.18%, respectively. Low strain colocalizes with low shear stress downstream of plaques. Higher strain can be found in all other plaque regions, with the highest strain found in regions exposed to the highest shear stresses. This indicates that high shear stress might destabilize plaques, which could lead to plaque rupture.


Circulation | 2003

Augmentation of Wall Shear Stress Inhibits Neointimal Hyperplasia After Stent Implantation Inhibition Through Reduction of Inflammation

Stéphane G. Carlier; Luc van Damme; Casper P. Blommerde; Jolanda J. Wentzel; Glenn van Langehove; Stephan Verheye; Mark M. Kockx; Michiel Knaapen; Caroline Cheng; Frank J. H. Gijsen; Dirk J. Duncker; Nikos Stergiopulos; Cornelis J. Slager; Patrick W. Serruys; Rob Krams

Background—Low wall shear stress (WSS) increases neointimal hyperplasia (NH) in vein grafts and stents. We studied the causal relationship between WSS and NH formation in stents by locally increasing WSS with a flow divider (Anti-Restenotic Diffuser, Endoart SA) placed in the center of the stent. Methods and Results—In 9 rabbits fed a high-cholesterol diet for 2 months to induce endothelial dysfunction, 18 stents were implanted in the right and left external iliac arteries (1 stent per vessel). Lumen diameters were measured by quantitative angiography before and after implantation and at 4-week follow-up, at which time, macrophage accumulation and interruption of the internal elastic lamina was determined. Cross sections of stent segments within the ARED (S+ARED), outside the ARED (S[minus]ARED), and in corresponding segments of the contralateral control stent (SCTRL) were analyzed. Changes in WSS induced by the ARED placement were derived by computational fluid dynamics. Computational fluid dynamics analysis demonstrated that WSS increased from 0.38 to 0.82 N/m2 in the S+ARED immediately after ARED placement. This augmentation of shear stress was accompanied by (1) lower mean late luminal loss by quantitative angiography ([minus]0.23±0.22 versus [minus]0.58±0.30 mm, P =0.02), (2) reduction in NH (1.48±0.58, 2.46±1.25, and 2.36±1.13 mm2, P <0.01, respectively, for S+ARED, S[minus]ARED, and SCTRL), and (3) a reduced inflammation score and a reduced injury score. Increments in shear stress did not change the relationship between injury score and NH or between inflammation score and NH. Conclusions—The newly developed ARED flow divider significantly increases WSS, and this local increment in WSS is accompanied by a local reduction in NH and a local reduction in inflammation and injury. The present study is therefore the first to provide direct evidence for an important modulating role of shear stress in in-stent neointimal hyperplasia.


Biomedical Engineering Online | 2008

Simulation of stent deployment in a realistic human coronary artery

Frank J. H. Gijsen; Francesco Migliavacca; Silvia Schievano; L. Socci; Lorenza Petrini; Attila Thury; Jolanda J. Wentzel; Anton F.W. van der Steen; Patrick W. Serruys; Gabriele Dubini

BackgroundThe process of restenosis after a stenting procedure is related to local biomechanical environment. Arterial wall stresses caused by the interaction of the stent with the vascular wall and possibly stress induced stent strut fracture are two important parameters. The knowledge of these parameters after stent deployment in a patient derived 3D reconstruction of a diseased coronary artery might give insights in the understanding of the process of restenosis.Methods3D reconstruction of a mildly stenosed coronary artery was carried out based on a combination of biplane angiography and intravascular ultrasound. Finite element method computations were performed to simulate the deployment of a stent inside the reconstructed coronary artery model at inflation pressure of 1.0 MPa. Strut thickness of the stent was varied to investigate stresses in the stent and the vessel wall.ResultsDeformed configurations, pressure-lumen area relationship and stress distribution in the arterial wall and stent struts were studied. The simulations show how the stent pushes the arterial wall towards the outside allowing the expansion of the occluded artery. Higher stresses in the arterial wall are present behind the stent struts and in regions where the arterial wall was thin. Values of 200 MPa for the peak stresses in the stent strut were detected near the connecting parts between the stent struts, and they were only just below the fatigue stress. Decreasing strut thickness might reduce arterial damage without increasing stresses in the struts significantly.ConclusionThe method presented in this paper can be used to predict stresses in the stent struts and the vessel wall, and thus evaluate whether a specific stent design is optimal for a specific patient.


Journal of Biomechanical Engineering-transactions of The Asme | 2013

Variability of Computational Fluid Dynamics Solutions for Pressure and Flow in a Giant Aneurysm: The ASME 2012 Summer Bioengineering Conference CFD Challenge

David A. Steinman; Yiemeng Hoi; Paul Fahy; Liam Morris; Michael T. Walsh; Nicolas Aristokleous; Andreas S. Anayiotos; Yannis Papaharilaou; Amirhossein Arzani; Shawn C. Shadden; Philipp Berg; Gábor Janiga; Joris Bols; Patrick Segers; Neil W. Bressloff; Merih Cibis; Frank J. H. Gijsen; Salvatore Cito; Jordi Pallares; Leonard D. Browne; Jennifer A. Costelloe; Adrian G. Lynch; Joris Degroote; Jan Vierendeels; Wenyu Fu; Aike Qiao; Simona Hodis; David F. Kallmes; Hardeep S. Kalsi; Quan Long

Stimulated by a recent controversy regarding pressure drops predicted in a giant aneurysm with a proximal stenosis, the present study sought to assess variability in the prediction of pressures and flow by a wide variety of research groups. In phase I, lumen geometry, flow rates, and fluid properties were specified, leaving each research group to choose their solver, discretization, and solution strategies. Variability was assessed by having each group interpolate their results onto a standardized mesh and centerline. For phase II, a physical model of the geometry was constructed, from which pressure and flow rates were measured. Groups repeated their simulations using a geometry reconstructed from a micro-computed tomography (CT) scan of the physical model with the measured flow rates and fluid properties. Phase I results from 25 groups demonstrated remarkable consistency in the pressure patterns, with the majority predicting peak systolic pressure drops within 8% of each other. Aneurysm sac flow patterns were more variable with only a few groups reporting peak systolic flow instabilities owing to their use of high temporal resolutions. Variability for phase II was comparable, and the median predicted pressure drops were within a few millimeters of mercury of the measured values but only after accounting for submillimeter errors in the reconstruction of the life-sized flow model from micro-CT. In summary, pressure can be predicted with consistency by CFD across a wide range of solvers and solution strategies, but this may not hold true for specific flow patterns or derived quantities. Future challenges are needed and should focus on hemodynamic quantities thought to be of clinical interest.


Journal of Biomechanics | 2011

The influence of boundary conditions on wall shear stress distribution in patients specific coronary trees

Alina G. van der Giessen; Harald C. Groen; Pierre André Doriot; Pim J. de Feyter; Antonius F.W. van der Steen; Fn Frans van de Vosse; Jolanda J. Wentzel; Frank J. H. Gijsen

Patient specific geometrical data on human coronary arteries can be reliably obtained multislice computer tomography (MSCT) imaging. MSCT cannot provide hemodynamic variables, and the outflow through the side branches must be estimated. The impact of two different models to determine flow through the side branches on the wall shear stress (WSS) distribution in patient specific geometries is evaluated. Murrays law predicts that the flow ratio through the side branches scales with the ratio of the diameter of the side branches to the third power. The empirical model is based on flow measurements performed by Doriot et al. (2000) in angiographically normal coronary arteries. The fit based on these measurements showed that the flow ratio through the side branches can best be described with a power of 2.27. The experimental data imply that Murrays law underestimates the flow through the side branches. We applied the two models to study the WSS distribution in 6 coronary artery trees. Under steady flow conditions, the average WSS between the side branches differed significantly for the two models: the average WSS was 8% higher for Murrays law and the relative difference ranged from -5% to +27%. These differences scale with the difference in flow rate. Near the bifurcations, the differences in WSS were more pronounced: the size of the low WSS regions was significantly larger when applying the empirical model (13%), ranging from -12% to +68%. Predicting outflow based on Murrays law underestimates the flow through the side branches. Especially near side branches, the regions where atherosclerotic plaques preferentially develop, the differences are significant and application of Murrays law underestimates the size of the low WSS region.


Catheterization and Cardiovascular Interventions | 2009

In vivo validation of CAAS QCA-3D coronary reconstruction using fusion of angiography and intravascular ultrasound (ANGUS)†

Johan C.H. Schuurbiers; Nieves Gonzalo Lopez; Jurgen Ligthart; Frank J. H. Gijsen; Jouke Dijkstra; Patrick W. Serruys; Antonius F. W. van der Steen; Jolanda J. Wentzel

The CAAS QCA‐3D system (Pie Medical Imaging BV, the Netherlands) was validated against 3D reconstructions based on fusion of angiography and intravascular ultrasound (ANGUS), allowing slice by slice validation of the lumen areas and 3D geometric values.

Collaboration


Dive into the Frank J. H. Gijsen's collaboration.

Top Co-Authors

Avatar

Jolanda J. Wentzel

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Aad van der Lugt

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Cornelis J. Slager

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Harald C. Groen

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Lambert Speelman

Erasmus University Rotterdam

View shared research outputs
Researchain Logo
Decentralizing Knowledge