Fujiro Ishikawa
Iwate Medical University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Fujiro Ishikawa.
American Journal of Orthodontics and Dentofacial Orthopedics | 1999
Hirokazu Nakano; Kazuro Satoh; Robert Norris; Tomoaki Jin; Tetsuya Kamegai; Fujiro Ishikawa; Hirofumi Katsura
The purpose of this study was to clarify the mechanical properties of 42 brands of nickel-titanium alloy orthodontic wires from 9 manufacturers by conducting three-point bending tests under uniform testing conditions. Manufacturers included A-Company, Hoya Medical, Lancer, Ormco, Rocky Mountain, Sankin, Tomy (GAC), TP, and 3M/Unitek. Cobalt-chrome, and titanium-molybdenum alloy wires were also tested as a reference for comparison of force levels. All reported data were recorded during the unloading process to simulate the force that a wire exerts on a tooth as it is moved into the dental arch from a position of malocclusion. The following results were obtained for the nickel-titanium wires tested. (1) Among the 0.016 inch round wires tested under a maximum deflection of 1.5 mm, the difference between the smallest (Copper nickel-titanium 35) and the largest (Aline) load values was 136 g. For the 0.016 x 0.022 inch rectangular wires tested, the difference between the smallest (Copper nickel-titanium 40) and the largest (Aline) load values was 337 g. (2) The change in load between 1.5 and 0.5 mm of deflection was examined to clarify the superelastic properties of the wires tested. For the 0.016 inch wires, 17 wire brands produced a load difference of less than 100 g, and two brands produced a difference of at least 100 g (Aline and Titanal = 100 g). For the 0.016 x 0.022 inch wires, 15 brands produced a load difference of less than 100 g, and eight brands produced a difference of over 100 g. The smallest and largest load differences were 3 g (Copper nickel-titanium 35) and 200 g (Aline). (3) The majority of the samples with a smaller load difference between deflections of 1.5 mm and 0.5 mm in the unloading process were found among super-elastic wires, while samples with a larger load difference were predominantly found among work-hardened wires. Compared with cobalt-chrome and TMA wires, nickel-titanium alloy wires exert significantly less force. However, the amount of force varies greatly from brand to brand. Consequently, when using nickel-titanium alloy wires, brands must be selected carefully by taking into consideration the severity of the malocclusion and the stage of orthodontic treatment in each case. It is the intent of this study to offer clinicians an unbiased guide for the selection of appropriate nickel-titanium alloy wires.
Oral Surgery, Oral Medicine, Oral Pathology | 1990
Keigo Kudo; Masayoshi Miyasawa; Yukio Fujioka; Tetsuya Kamegai; Hirokazu Nakano; Yukio Seino; Fujiro Ishikawa; Tsukasa Shioyama; Kanji Ishibashi
During the last 4 years 73 dental implants with root-coated bioglass to replace one to three teeth in the premolar and molar sites of the mandible were inserted. The bonding ratio between implant and bone was observed clinically 1 year after implantation and installation of the superior structure. This ratio measured 52.4% to 63.3%. An acoustoelectric tester was developed that advanced our skills. The emphasis was placed on a tight fit between implant and surrounding bone.
European Journal of Orthodontics | 1998
Munetsugu Kubota; Hirokazu Nakano; Isao Sanjo; Kazuro Satoh; Toshiya Sanjo; Tetsuya Kamegai; Fujiro Ishikawa
Dental Journal of Iwate Medical University | 1996
Masanori Shozushima; Hirokazu Nakano; Nunetsugu Kubota; Tetsuya Kamegai; Fujiro Ishikawa; Hiroki Saito; Kimio Sakamaki
The Japanese Journal of Jaw Deformities | 1997
Hiroki Miyate; Mitsumasa Yokota; Manabu Shimada; Yoshihito Ishikawa; Kiyoshi Tamura; Takanori Oya; Keigo Kudo; Hiroyuki Miura; Fujiro Ishikawa
American Journal of Orthodontics and Dentofacial Orthopedics | 1994
Kingo Nakano; Tetsuya Kamegai; Hirokazu Nakano; Yukio Seino; Toshiyoshi Tatsuki; Kazuro Satoh; Fujiro Ishikawa; Yoshiaki Yamada
Japanese Journal of Oral & Maxillofacial Surgery | 1986
Keigo Kudo; Yukio Fujioka; Masayoshi Miyasawa; Kanji Ishibashi; Tsukasa Shioyama; Fujiro Ishikawa; Tetsuya Kamegai; Hirokazu Nakano; Yukio Seino
Dental Journal of Iwate Medical University | 1998
Munetsugu Kubota; Hirokazu Nakano; Kazuro Satoh; Tetsuya Kamegai; Fujiro Ishikawa; Masanori Shouzushima; Kimio Sakamaki
The Journal of Japanese Society of Stomatognathic Function | 1998
Masaru Ishigame; Hiroyuki Miura; Kazuro Satoh; Mitsuro Furumachi; Tsutomu Masuda; Fujiro Ishikawa
Japanese Journal of Psychosomatic Dentistry | 1998
Madoka Chida; Hiroyuki Miura; Kazuro Satoh; Hisayo Mayama; Fujiro Ishikawa