Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where G. O'Hara is active.

Publication


Featured researches published by G. O'Hara.


Journal of the American College of Cardiology | 2012

Usefulness of fluorine-18 positron emission tomography/computed tomography for identification of cardiovascular implantable electronic device infections.

J. Sarrazin; François Philippon; Michel Tessier; Jean Guimond; Franck Molin; Jean Champagne; Isabelle Nault; L. Blier; Maxime Nadeau; Lyne Charbonneau; Mikaël Trottier; G. O'Hara

OBJECTIVES This study evaluated the usefulness of fluorodesoxyglucose marked by fluorine-18 ((18)F-FDG) positron emission tomography (PET) and computed tomography (CT) in patients with suspected cardiovascular implantable electronic device (CIED) infection. BACKGROUND CIED infection is sometimes challenging to diagnose. Because extraction is associated with significant morbidity/mortality, new imaging modalities to confirm the infection and its dissemination would be of clinical value. METHODS Three groups were compared. In Group A, 42 patients with suspected CIED infection underwent (18)F-FDG PET/CT. Positive PET/CT was defined as abnormal uptake along cardiac devices. Group B included 12 patients without infection who underwent PET/CT 4 to 8 weeks post-implant. Group C included 12 patients implanted for >6 months without infection who underwent PET/CT for another indication. Semi-quantitative ratio (SQR) was obtained from the ratio between maximal uptake and lung parenchyma uptake. RESULTS In Group A, 32 of 42 patients with suspected CIED infection had positive PET/CT. Twenty-four patients with positive PET/CT underwent extraction with excellent correlation. In 7 patients with positive PET/CT, 6 were treated as superficial infection with clinical resolution. One patient with positive PET/CT but negative leukocyte scan was considered false positive due to Dacron pouch. Ten patients with negative-PET/CT were treated with antibiotics and none has relapsed at 12.9 ± 1.9 months. In Group B, patients had mild uptake seen at the level of the connector. There was no abnormal uptake in Group C patients. Median SQR was significantly higher in Group A (A = 2.02 vs. B = 1.08 vs. C = 0.57; p < 0.001). CONCLUSIONS PET/CT is useful in differentiating between CIED infection and recent post-implant changes. It may guide appropriate therapy.


Circulation | 2007

Obesity and Metabolic Syndrome Are Independent Risk Factors for Atrial Fibrillation After Coronary Artery Bypass Graft Surgery

Najmeddine Echahidi; Dania Mohty; Philippe Pibarot; Jean-Pierre Després; G. O'Hara; Jean Champagne; François Philippon; Pascal Daleau; Pierre Voisine; Patrick Mathieu

Background— Postoperative atrial fibrillation (POAF) is a highly prevalent complication after cardiac surgery with substantial effects on outcomes. Previous studies have reported that obesity is a risk factor for POAF after cardiac surgery. However, it is unknown whether the metabolic syndrome (MS) also increases the risk of postoperative atrial fibrillation. Methods and Results— We retrospectively analyzed the association between obesity and MS and the incidence of new-onset POAF in a total of 5085 patients who underwent isolated coronary artery bypass grafting surgery with no concomitant valvular surgery. Of these patients, 1468 (29%) were obese (body mass index ≥30 kg/m2) and 2320 (46%) had a MS as defined by the NCEP-ATPIII. POAF occurred in 1374 (27%) of the patients. Obesity was associated (P<0.001) with increased incidence of POAF in the whole cohort as well as in patients >50 years old but not in patients ≤50 years old. In these patients, MS was the only metabolic factor to be significantly associated with higher incidence of POAF (12% versus 6%, P=0.01). In >50-year-old patients, mild (30 ≤ body mass index <35 kg/m2) and moderate–severe (body mass index ≥35 kg/m2) obesity were independently associated with a 1.4-fold (95% CI: 1.10 to 1.71; P=0.004) and 2.3-fold (95% CI: 1.71 to 3.13; P<0.0001) increase in the risk of POAF, respectively. In ≤50-year-old patients, MS (relative risk [RR]: 2.36; 95% CI: 1.10 to 5.12; P=0.02) but not obesity was independently associated with POAF. Conclusion— This study demonstrates that obesity is a powerful risk factor for the occurrence of POAF after isolated coronary artery bypass grafting surgery in patients older than 50 years. However, in the younger population, this association is not observed and MS is the only metabolic risk factor to be independently associated with POAF.


The Lancet | 2015

Cardioverter defibrillator implantation without induction of ventricular fibrillation: A single-blind, non-inferiority, randomised controlled trial (SIMPLE)

Jeff S. Healey; Stefan H. Hohnloser; Michael Glikson; Jörg Neuzner; Phillipe Mabo; Xavier Vinolas; Josef Kautzner; G. O'Hara; Lieselot VanErven; Fredrik Gadler; Janice Pogue; Ursula Appl; Jim Gilkerson; Thierry Pochet; Kenneth M. Stein; Béla Merkely; Susan Chrolavicius; Brandi Meeks; Csaba Földesi; Bernard Thibault; Stuart J. Connolly

BACKGROUND Defibrillation testing by induction and termination of ventricular fibrillation is widely done at the time of implantation of implantable cardioverter defibrillators (ICDs). We aimed to compare the efficacy and safety of ICD implantation without defibrillation testing versus the standard of ICD implantation with defibrillation testing. METHODS In this single-blind, randomised, multicentre, non-inferiority trial (Shockless IMPLant Evaluation [SIMPLE]), we recruited patients aged older than 18 years receiving their first ICD for standard indications at 85 hospitals in 18 countries worldwide. Exclusion criteria included pregnancy, awaiting transplantation, particpation in another randomised trial, unavailability for follow-up, or if it was expected that the ICD would have to be implanted on the right-hand side of the chest. Patients undergoing initial implantation of a Boston Scientific ICD were randomly assigned (1:1) using a computer-generated sequence to have either defibrillation testing (testing group) or not (no-testing group). We used random block sizes to conceal treatment allocation from the patients, and randomisation was stratified by clinical centre. Our primary efficacy analysis tested the intention-to-treat population for non-inferiority of no-testing versus testing by use of a composite outcome of arrhythmic death or failed appropriate shock (ie, a shock that did not terminate a spontaneous episode of ventricular tachycardia or fibrillation). The non-inferiority margin was a hazard ratio (HR) of 1·5 calculated from a proportional hazards model with no-testing versus testing as the only covariate; if the upper bound of the 95% CI was less than 1·5, we concluded that ICD insertion without testing was non-inferior to ICD with testing. We examined safety with two, 30 day, adverse event outcome clusters. The trial is registered with ClinicalTrials.gov, number NCT00800384. FINDINGS Between Jan 13, 2009, and April 4, 2011, of 2500 eligible patients, 1253 were randomly assigned to defibrillation testing and 1247 to no-testing, and followed up for a mean of 3·1 years (SD 1·0). The primary outcome of arrhythmic death or failed appropriate shock occurred in fewer patients (90 [7% per year]) in the no-testing group than patients who did receive it (104 [8% per year]; HR 0·86, 95% CI 0·65-1·14; pnon-inferiority <0·0001). The first safety composite outcome occurred in 69 (5·6%) of 1236 patients with no-testing and in 81 (6·5%) of 1242 patients with defibrillation testing, p=0·33. The second, pre-specified safety composite outcome, which included only events most likely to be directly caused by testing, occurred in 3·2% of patients with no-testing and in 4·5% with defibrillation testing, p=0·08. Heart failure needing intravenous treatment with inotropes or diuretics was the most common adverse event (in 20 [2%] of 1236 patients in the no-testing group vs 28 [2%] of 1242 patients in the testing group, p=0·25). INTERPRETATION Routine defibrillation testing at the time of ICD implantation is generally well tolerated, but does not improve shock efficacy or reduce arrhythmic death. FUNDING Boston Scientific and the Heart and Stroke Foundation (Ontario Provincial office).


Pharmacogenetics | 1999

Involvement of CYP2D6 activity in the N-oxidation of procainamide in man.

Etienne Lessard; Bettina A. Hamelin; Labbé L; G. O'Hara; Bélanger Pm; Jacques Turgeon

Occurrence of a lupus-like syndrome in a significant number of patients treated with procainamide has limited the clinical use of this antiarrhythmic drug. In-vitro studies conducted in our laboratory have demonstrated that CYP2D6 is the major cytochrome P450 isozyme involved in the formation of N-hydroxyprocainamide, a metabolite potentially involved in the drug-induced lupus erythematosus syndrome observed with procainamide. In the current study, we evaluated the role of CYP2D6 activity in the in-vivo oxidation of procainamide in man. Nineteen healthy individuals, 13 with high (extensive metabolizers) and six with low (poor metabolizers) CYP2D6 activity, received a single 500 mg oral dose of procainamide hydrochloride on two occasions, once alone (period 1) and once during the concomitant administration of the selective inhibitor quinidine (50 mg four times daily; period 2). Blood and urine samples were collected over 36 h after drug administration of procainamide and analysed for procainamide and its major metabolites (N-acetylprocainamide, desethylprocainamide, N-acetyl-desethylprocainamide, p-aminobenzoic acid and its N-acetylated derivative, and nitroprocainamide). No differences were observed in the oral and renal clearances of procainamide between extensive metabolizers and poor metabolizers during either study period. However, partial metabolic clearance of procainamide to desethylprocainamide was significantly greater in extensive metabolizers than in poor metabolizers during both periods. Most importantly, the urinary excretion of nitroprocainamide during period 1 was measurable in 7/13 extensive metabolizers but in none of the poor metabolizers. During the concomitant administration of quinidine, nitroprocainamide could not be detected in the urine of any individuals tested. Therefore, our results suggest that CYP2D6 is involved in the in-vivo aliphatic amine deethylation and N-oxidation of procainamide at its arylamine function in man. Further studies are needed to demonstrate whether a low CYP2D6 activity, either genetically determined or pharmacologically modulated, could prevent drug-induced lupus erythematosus syndrome observed during chronic therapy with procainamide.


Journal of Clinical Psychopharmacology | 2001

Diphenhydramine alters the disposition of venlafaxine through inhibition of CYP2D6 activity in humans.

Etienne Lessard; Marie-Andrée Yessine; Bettina A. Hamelin; Caroline Gauvin; Line Labbé; G. O'Hara; Jacynthe Leblanc; Jacques Turgeon

CYP2D6 is the major enzyme involved in the metabolism of venlafaxine. Subjects with a low CYP2D6 activity have increased plasma concentrations of venlafaxine that may predispose them to cardiovascular side effects. In vitro and in vivo studies showed that diphenhydramine, a nonprescription antihistamine, can inhibit CYP2D6 activity. Therefore, the authors investigated in this study a potential drug interaction between diphenhydramine and venlafaxine. Fifteen male volunteers, nine with the extensive metabolizer (EM) and six with the poor metabolizer (PM) phenotype of CYP2D6, received venlafaxine hydrochloride 18.75 mg orally every 12 hours for 48 hours on two occasions (1 week apart): once alone and once during the concomitant administration of diphenhydramine hydrochloride (50 mg every 12 hours). Blood and urine samples were collected for 12 hours under steady-state conditions. In EMs, diphenhydramine decreased venlafaxine oral clearance from 104 ± 60 L/hr to 43 ± 23 L/hr (mean ± SD; p < 0.05) without any effect on renal clearance (4 ± 1 L/hr during venlafaxine alone and 4 ± 2 L/hr during venlafaxine plus diphenhydramine). In PMs, coadministration of diphenhydramine did not cause significant changes in oral clearance and partial metabolic clearances of venlafaxine to its various metabolites. Diphenhydramine disposition was only slightly affected by genetically determined low CYP2D6 activity or concomitant administration of venlafaxine. In conclusion, diphenhydramine, at therapeutic doses, inhibits CYP2D6-mediated metabolism of venlafaxine in humans. Clinically significant interactions could be encountered during the concomitant administration of diphenhydramine and other antidepressant or antipsychotic drugs that are substrates of CYP2D6.


European Heart Journal | 2009

Middle-aged men with increased waist circumference and elevated C-reactive protein level are at higher risk for postoperative atrial fibrillation following coronary artery bypass grafting surgery

Nicolas Girerd; Philippe Pibarot; Dominique Fournier; Pascal Daleau; Pierre Voisine; G. O'Hara; Jean-Pierre Després; Patrick Mathieu

INTRODUCTION We recently demonstrated that metabolic syndrome (MetS) is an independent risk factor for postoperative atrial fibrillation (POAF) following coronary artery bypass grafting (CABG). In the present work, we sought to determine which feature of the MetS is associated with POAF. METHODS AND RESULTS We retrospectively analysed the association between metabolic features and the incidence of new-onset POAF in a total of 2214 male patients <65 years who underwent first isolated CABG. Anthropometric data including waist circumference (WC) and complete preoperative lipid profile were available. We also conducted a nested case-control substudy including 147 patients who developed POAF, and were matched for age with a control population. In these patients, C-reactive protein, interleukin-6 (IL-6), and thiobarbituric acid-reactive substances (TBARS; evaluating the oxidative stress) blood levels were determined. In the whole cohort, 19.6% of patients developed POAF. On univariate analysis, body mass index (BMI; P = 0.002) and WC (P = 0.001) were the only anthropometric variables significantly associated with increased incidence of POAF. In the multivariable logistic model, the only independent predictors of POAF were a WC > 102 cm [odds ratio (OR) = 1.40, P = 0.04)] and older age (OR = 1.08, P < 0.001). In the nested case-control substudy C-reactive protein, IL-6, and TBARS levels were not significantly different in patients with or without POAF. Of particular significance, patients with elevated WC > 102 cm and C-reactive protein > 1.5 mg/L or IL-6 >2.2 pg/mL were at a high risk of developing POAF (respectively, OR = 2.32, P = 0.02 and OR = 2.27, P = 0.03). CONCLUSION Patients with increased WC combined with elevated C-reactive protein levels are at higher risk for POAF. Thus, interventions targeting inflammation related to visceral obesity might help reducing the incidence of POAF.


Pacing and Clinical Electrophysiology | 2002

Pacemaker contact sensitivity: case report and review of the literature.

Jean‐Pierre Déry; Marcel R. Gilbert; G. O'Hara; Jean Champagne; Denis Desaulniers; Paul C. Cartier; François Philippon

DÉRY, J.‐P., et al.: Pacemaker Contact Sensitivity: Case Report and Review of the Literature. Pacemaker contact sensitivity is a rare condition. Less than 25 reports of pacemaker skin reaction have been described over the past 30 years. This report describes one patient who developed contact dermatitis after implantation of two subsequent pacemakers. The diagnosis was made with skin patch tests that were positive to polyurethane 75D and polysulfone beige, two of the pacemaker and connector components. Review of the literature and general guidelines for the management of this unusual condition is depicted in this report.


American Heart Journal | 2012

The rationale and design of the Shockless IMPLant Evaluation (SIMPLE) trial: A randomized, controlled trial of defibrillation testing at the time of defibrillator implantation

Jeff S. Healey; Stefan H. Hohnloser; Michael Glikson; Joerg Neuzner; X. Vinolas; Philippe Mabo; Josef Kautzner; G. O'Hara; Liselot Van Erven; Frederick Gadler; Ursula Appl; Stuart J. Connolly

Defibrillation testing (DT) has been an integral part of defibrillator (implantable cardioverter defibrillator [ICD]) implantation; however, there is little evidence that it improves outcomes. Surveys show a trend toward ICD implantation without DT, which now exceeds 30% to 60% in some regions. Because there is no evidence to support dramatic shift in practice, a randomized trial is urgently needed. The SIMPLE trial will determine if ICD implantation without any DT is noninferior to implantation with DT. Patients will be eligible if they are receiving their first ICD using a Boston Scientific device (Boston Scientific, Natick, MA). Patients will be randomized to DT or no DT at the time of ICD implantation. In the DT arm, physicians will make all reasonable efforts to ensure 1 successful intraoperative defibrillation at 17 J or 2 at 21 J. The first clinical shock in all tachycardia zones will be set to 31 J for all patients. The primary outcome of SIMPLE will be the composite of ineffective appropriate shock or arrhythmic death. The safety outcome of SIMPLE will include a composite of potentially DT-related procedural complications within 30 days of ICD implantation. Several secondary outcomes will be evaluated, including all-cause mortality and heart failure hospitalization. Enrollment of 2,500 patients with 3.5-year mean follow-up will provide sufficient statistical power to demonstrate noninferiority. The study is being performed at approximately 90 centers in Canada, Europe, Israel, and Asia Pacific with final results expected in 2013.


Canadian Journal of Cardiology | 2013

Anticoagulation Management Pre- and Post Atrial Fibrillation Ablation: A Survey of Canadian Centres

Vartan Mardigyan; Atul Verma; David H. Birnie; Peter G. Guerra; Damian P. Redfearn; G. Becker; Jean Champagne; John L. Sapp; Lorne J. Gula; Ratika Parkash; Laurent Macle; Eugene Crystal; G. O'Hara; Yaariv Khaykin; Marcio Sturmer; George D. Veenhuyzen; Isabelle Greiss; J. Sarrazin; Iqwal Mangat; Paul Novak; Allan C. Skanes; Jean-Francois Roux; Vijay S. Chauhan; Tom Hadjis; Carlos A. Morillo; Vidal Essebag

BACKGROUND Anticoagulation in patients undergoing atrial fibrillation (AF) ablation is crucial to minimize the risk of thromboembolic complications. There are broad ranges of approaches to anticoagulation management pre and post AF ablation procedures. The purpose of this study was to determine the anticoagulation strategies currently in use in patients peri- and post AF ablation in Canada. METHODS A Web-based national survey of electrophysiologists performing AF ablation in Canada collected data regarding anticoagulation practice prior to ablation, periprocedural bridging, and duration of postablation anticoagulation. RESULTS The survey was completed by 36 (97%) of the 37 electrophysiologists performing AF ablation across Canada. Prior to AF ablation, 58% of electrophysiologists started anticoagulation for patients with paroxysmal AF CHADS(2) scores of 0 to 1, 92% for paroxysmal AF CHADS(2) scores ≥ 2, 83% for persistent AF CHADS(2) scores of 0 to 1, and 97% for persistent AF CHADS(2) scores ≥ 2. For patients with CHADS(2) 0 to 1, warfarin was continued for at least 3 months by most physicians (89% for paroxysmal and 94% for persistent AF). For patients with CHADS(2) ≥ 2 and with no recurrence of AF at 1 year post ablation, 89% of physicians continued warfarin. CONCLUSIONS Although guidelines recommend long-term anticoagulation in patients with CHADS(2) ≥ 2, 11% of physicians would discontinue warfarin in patients with no evidence of recurrent AF 1 year post successful ablation. Significant heterogeneity exists regarding periprocedural anticoagulation management in clinical practice. Clinical trial evidence is required to guide optimal periprocedural anticoagulation and therapeutic decisions regarding long-term anticoagulation after an apparently successful catheter ablation for AF.


Europace | 2013

Detection of high incidence of Riata lead breaches by systematic postero-anterior and lateral chest X-ray in a large cohort

Christian Steinberg; J. Sarrazin; François Philippon; Marc-André Bouchard; G. O'Hara; F. Molin; I. Nault; L. Blier; Jean Champagne

AIMS Insulation breaches with externalization of conductor cables have been described for St-Jude Medical Riata™ defibrillation leads. Published data on the incidence of Riata lead abnormalities are quite heterogeneous. The objective of this study was to estimate systematically the prevalence of lead abnormalities using a postero-anterior (PA) and lateral chest X-ray (CXR). METHODS AND RESULTS From 2002 to 2008, 552 Riata defibrillation leads were implanted at our centre. We evaluated patients for potential insulation breaches. A PA and lateral CXR was obtained. Chest X-rays were reviewed by two electrophysiologists using a zooming function with magnification up to factor 7.5 and were classified as normal or abnormal for the presence of conductor externalization. A total of 284 patients were included. Riata lead models were 1570, 1580, 1582, 1590, 1592, 7000, 7002, and 7022. The total frequency of radiological lead defects was 24.3%. Insulation breaches occurred at zones of major lead curvature. Mean maximal spacing between extruding lead components was 3.6 ± 1.9 mm (range 2.0-12.4). Abnormal CXRs were more frequent in 8F leads (31.4% vs. 6.3%; P < 0.001). Most defects occurred with lead models 1582 (41.2%) and 1580 (31.4%). Mean time since implantation was longer in abnormal leads (6.7 vs. 5.9 years; P < 0.001). Abnormal leads had higher pacing thresholds (1.1 ± 0.8 V vs. 0.9 ± 0.4 V; P = 0.02). CONCLUSION The incidence of insulation breach in Riata leads is much higher than quoted by the manufacturer or reported by most of the literature. A PA and lateral CXR with zooming appears adequate to identify lead breaches when reviewed by an electrophysiologist. Riata lead breaches without electrical abnormalities present a management dilemma and will require further studies.

Collaboration


Dive into the G. O'Hara's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Christian Steinberg

University of British Columbia

View shared research outputs
Top Co-Authors

Avatar

Franck Molin

Université de Montréal

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge