Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where G. Pizzigoni is active.

Publication


Featured researches published by G. Pizzigoni.


Journal of Instrumentation | 2017

Measuring the electron neutrino mass with improved sensitivity: the HOLMES experiment

A. Giachero; Bradley K. Alpert; D.T. Becker; D. Bennett; M. Biasotti; C. Brofferio; V. Ceriale; G. Ceruti; D. Corsini; Peter K. Day; M. De Gerone; R. Dressler; M. Faverzani; E. Ferri; J. W. Fowler; E. Fumagalli; G. Gallucci; J. Gard; F. Gatti; J. Hays-Wehle; S. Heinitz; G. C. Hilton; U. Köster; M. Lusignoli; J. A. B. Mates; S. Nisi; A. Nucciotti; A. Orlando; L. Parodi; G. Pessina

HOLMES is a new experiment aiming at directly measuring the neutrino mass with a sensitivity below 2 eV. HOLMES will perform a calorimetric measurement of the energy released in the decay of


Proceedings of SPIE | 2014

The Cryogenic AntiCoincidence detector for ATHENA: the progress towards the final pixel design

C. Macculi; Luigi Piro; Donatella Cea; L. Colasanti; Simone Lotti; L. Natalucci; F. Gatti; D. Bagliani; M. Biasotti; D. Corsini; G. Pizzigoni; G. Torrioli; Marco Barbera; Teresa Mineo; Emanuele Perinati

^{163}


IEEE Transactions on Applied Superconductivity | 2013

Status of the MARE Experiment

M. R. Gomes; F. Gatti; A. Nucciotti; Pietro Manfrinetti; M. Galeazzi; E. Alves; D. Bagliani; N.P. Barradas; S. Basak; M. Biasotti; E. Ferri; A. Kling; G. Pizzigoni; K. Prasai; J. Rocha

Ho. The calorimetric measurement eliminates systematic uncertainties arising from the use of external beta sources, as in experiments with spectrometers. This measurement was proposed in 1982 by A. De Rujula and M. Lusignoli, but only recently the detector technological progress has allowed to design a sensitive experiment. HOLMES will deploy a large array of low temperature microcalorimeters with implanted


Journal of Physics: Conference Series | 2014

Large Area ?-thermal Phonon TES Detector Mediated by the quasi-particle Diffusion Signal for Space Application

G. Pizzigoni; D Bagliani; M. Biasotti; D. Corsini; M De Gerone; F. Gatti; C. Macculi; Luigi Piro

^{163}


nuclear science symposium and medical imaging conference | 2015

A high resolution timing counter for the MEG II experiment

M. Simonetta; G. Boca; P. W. Cattaneo; M. De Gerone; F. Gatti; W. Ootani; G. Pizzigoni; M. Rossella; N. Shibata; Y. Uchiyama; K. Yoshida; M. Nishimura; Michiyasu Nakao

Ho nuclei. HOLMES, besides being an important step forward in the direct neutrino mass measurement with a calorimetric approach, will also establish the potential of this approach to extend the sensitivity down to 0.1 eV and lower. In its final configuration HOLMES will collect about


Journal of Low Temperature Physics | 2014

Preliminary Results of the MARE Experiment

E. Ferri; D. Bagliani; M. Biassotti; G. Ceruti; D. Corsini; M. Faverzani; F. Gatti; A. Giachero; C. Gotti; Caroline A. Kilbourne; A. Kling; S. Kraft-Bermuth; M. Maino; Pietro Manfrinetti; A. Nucciotti; G. Pessina; G. Pizzigoni; M. Ribeiro Gomes; D. Schaeffer; M. Sisti

3\cdot 10^{13}


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2016

A high resolution Timing Counter for the MEG II experiment

M. De Gerone; A. Bevilacqua; M. Biasotti; G. Boca; P. W. Cattaneo; F. Gatti; M. Nishimura; W. Ootani; G. Pizzigoni; M. Rossella; N. Shibata; F. Siccardi; M. Simonetta; Y. Uchiyama; K. Yoshida

decays with 1000 detectors characterized by an instrumental energy resolution of the order of few eV and a time resolution of few microseconds. To embed the


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2016

Test and characterisation of SiPMs for the MEGII high resolution Timing Counter

M. Simonetta; M. Biasotti; G. Boca; P. W. Cattaneo; M. De Gerone; F. Gatti; R. Nardò; M. Nishimura; W. Ootani; G. Pizzigoni; M.C. Prata; M. Rossella; N. Shibata; Y. Uchiyama; K. Yoshida

^{163}


Proceedings of International Conference on New Photo-detectors — PoS(PhotoDet2015) | 2016

Pixelated Positron Timing Counter with SiPM-readout Scintillator for MEG II experiment

M. Nishimura; G. Boca; Paolo Walter Cattaneo; Matteo De Gerone; F. Gatti; W. Ootani; G. Pizzigoni; M. Rossella; Naoya Shibata; Simonetta Marcello; Yusuke Uchiyama; Kohei Yoshida

Ho into the gold absorbers a custom mass separator ion implanter is being developed. The detectors used for the HOLMES experiment will be Mo/Cu bilayers TESs (Transition Edge Sensors) on SiN


Journal of Low Temperature Physics | 2016

Transition-Edge Sensor Arrays of Microcalorimeters with \(^{163}\)Ho for Direct Neutrino Mass Measurements with HOLMES

A. Orlando; M. Biasotti; V. Ceriale; M. De Gerone; F. Gatti; J. Hays-Wehle; G. Pizzigoni; Daniel R. Schmidt; Daniel S. Swetz; Joel N. Ullom

_x

Collaboration


Dive into the G. Pizzigoni's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

M. De Gerone

Istituto Nazionale di Fisica Nucleare

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge