Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where W. Ootani is active.

Publication


Featured researches published by W. Ootani.


IEEE Transactions on Nuclear Science | 2014

Development of High Precision Timing Counter Based on Plastic Scintillator with SiPM Readout

Paolo Walter Cattaneo; Flavio Gatti; M. Nishimura; W. Ootani; Massimo Rossella; Yusuke Uchiyama

High-time-resolution counters based on plastic scintillator with silicon photomultiplier (SiPM) readout have been developed for applications to high energy physics experiments for which relatively large-sized counters are required. We have studied counter sizes up to 120 ×40 ×5 mm3 with series connection of multiple SiPMs to increase the sensitive area and thus achieve better time resolution. A readout scheme with analog shaping and digital waveform analysis is optimized to achieve the highest time resolution. The timing performance is measured using electrons from a 90Sr radioactive source, comparing different scintillators, counter dimensions, and types of near-ultraviolet sensitive SiPMs. As a result, a resolution of σ = 42 ±2 ps at 1 MeV energy deposition is obtained for counter size 60 ×30 ×5 mm3 with three SiPMs ( 3 ×3 mm2 each) at each end of the scintillator. The time resolution improves with the number of photons detected by the SiPMs. The SiPMs from Hamamatsu Photonics give the best time resolution because of their high photon detection efficiency in the near-ultraviolet region. Further improvement is possible by increasing the number of SiPMs attached to the scintillator.


European Physical Journal C | 2016

Measurement of the radiative decay of polarized muons in the MEG experiment

A.M. Baldini; Y. Bao; E. Baracchini; C. Bemporad; F. Berg; M. Biasotti; G. Boca; P. W. Cattaneo; G. Cavoto; F. Cei; G. Chiarello; C. Chiri; A. de Bari; M. De Gerone; A. D’Onofrio; S. Dussoni; Y. Fujii; L. Galli; F. Gatti; F. Grancagnolo; M. Grassi; A. Graziosi; D.N. Grigoriev; T. Haruyama; M. Hildebrandt; Z. Hodge; K. Ieki; F. Ignatov; T. Iwamoto; D. Kaneko

We studied the radiative muon decay


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2016

Time resolution of time-of-flight detector based on multiple scintillation counters readout by SiPMs

P. W. Cattaneo; M. De Gerone; F. Gatti; M. Nishimura; W. Ootani; M. Rossella; Shohei Shirabe; Y. Uchiyama


European Physical Journal C | 2016

Muon polarization in the MEG experiment: Predictions and measurements

A.M. Baldini; Y. Bao; E. Baracchini; C. Bemporad; F. Berg; M. Biasotti; G. Boca; P. W. Cattaneo; G. Cavoto; F. Cei; G. Chiarello; C. Chiri; A. de Bari; M. De Gerone; A. D’Onofrio; S. Dussoni; Y. Fujii; L. Galli; F. Gatti; F. Grancagnolo; M. Grassi; A. Graziosi; D.N. Grigoriev; T. Haruyama; M. Hildebrandt; Z. Hodge; K. Ieki; F. Ignatov; T. Iwamoto; D. Kaneko

{upmu }^{+} rightarrow mathrm {e}^{+} {upnu }bar{{upnu }}{upgamma }


Journal of the Physical Society of Japan | 2016

An Experimental Review of Charged Lepton Flavor Violation in Muon Channel

W. Ootani


Teion Kogaku (journal of The Cryogenic Society of Japan) | 2005

Development of a Method for Liquid Xenon Purification Using a Cryogenic Centrifugal Pump

S. Mihara; T. Haruyama; T. Iwamoto; Yusuke Uchiyama; W. Ootani; K. Kasami; Ryu Sawada; Kazuhiro Terasawa; T. Doke; Hiroaki Natori; Hajime Nishiguchi; A. Maki; Toshinori Mori; Shuei Yamada

μ+→e+νν¯γ by using for the first time an almost fully polarized muon source. We identified a large sample (


arXiv: High Energy Physics - Experiment | 2013

New constraint on the existence of the mu+-> e+ gamma decay

J. Adam; X. Bai; A.M. Baldini; E. Baracchini; C. Bemporad; G. Boca; P. W. Cattaneo; G. Cavoto; F. Cei; C. Cerri; A. de Bari; M. De Gerone; T. Doke; S. Dussoni; J. Egger; K. Fratini; Y. Fujii; L. Galli; G. Gallucci; F. Gatti; B. Golden; M. Grassi; A. Graziosi; D. N. Grigoriev; T. Haruyama; M. Hildebrandt; Y. Hisamatsu; F. Ignatov; T. Iwamoto; D. Kaneko


arXiv: Instrumentation and Detectors | 2013

MEG Upgrade Proposal

A.M. Baldini; M. De Gerone; A. L'Erario; G. Palama; Y. Uchiyama; Z. You; M. Cascella; F. Grancagnolo; W. Ootani; F. Raffaelli; C. Cerri; T. Haruyama; M. Panareo; A. Papa; L. Galli; B. I. Khazin; T. I. Kang; E. Ripiccini; A.S. Popov; H. Nishiguchi; G. Lim; A. S. Korenchenko; F. Gatti; T. Mori; G. Onorato; Ryu Sawada; Alfonso Maffezzoli; S. Mihara; D. Nicolò; P.-R. Kettle

sim


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2006

A radioactive point-source lattice for calibrating and monitoring the liquid xenon calorimeter of the MEG experiment

A. Baldini; C. Bemporad; Fabrizio Cei; S. Dussoni; F. Gatti; M. Grassi; T. Haruyama; Y. Hisamatsu; T. Iwamoto; S. Mihara; Toshinori Mori; Donato Nicolo; Hajime Nishiguchi; W. Ootani; A. Papa; R. Pazzi; Ryu Sawada; F. Sergiampietri; G. Signorelli; R Valle; S. Yamada


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2011

Calibration and monitoring of the MEG experiment by a proton beam from a Cockcroft–Walton accelerator

J. Adam; X. Bai; A.M. Baldini; E. Baracchini; C. Bemporad; G. Boca; Paolo Walter Cattaneo; G. Cavoto; Fabrizio Cei; C. Cerri; M. Corbo; N. Curalli; A. de Bari; M. De Gerone; T. Doke; S. Dussoni; J. Egger; K. Fratini; Y. Fujii; L. Galli; G. Gallucci; F. Gatti; B. Golden; M. Grassi; D. N. Grigoriev; T. Haruyama; M. Hildebrandt; F. Ignatov; T. Iwamoto; P.-R. Kettle

∼13,000) of these decays in a total sample of

Collaboration


Dive into the W. Ootani's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

M. De Gerone

Istituto Nazionale di Fisica Nucleare

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge