Gaëtan Gruel
Institut de radioprotection et de sûreté nucléaire
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Gaëtan Gruel.
Radiation Research | 2009
Aurélie Vaurijoux; Gaëtan Gruel; Frédéric Pouzoulet; Eric Gregoire; Cécile Martin; Sandrine Roch-Lefèvre; Pascale Voisin; Philippe Voisin; Laurence Roy
Abstract Vaurijoux, A., Gruel, G., Pouzoulet, F., Grégoire, E., Martin, C., Roch-Lefèvre, S., Voisin, P., Voisin, P. and Roy, L. Strategy for Population Triage Based on Dicentric Analysis. Radiat. Res. 171, 541–548 (2009). After large-scale accidental overexposure to ionizing radiation, a rapid triage of the exposed population can be performed by scoring dicentrics and ring chromosomes among 50 metaphases. This is rapid but is not accurate because the sensitivity is around 0.5 Gy. After the triage step, dose can be estimated by scoring 500 metaphases. This is lengthy but very accurate because the sensitivity is between 0.1 and 0.2 Gy. To improve the methodology, we propose the use of software for automatic dicentric scoring that was tested on victims of an accident in Dakar. Manual scoring of 50 metaphases was carried out, then manual scoring of 500 metaphases, and automatic scoring. Comparison between the dose classifications obtained with manual scoring on 50 metaphases and 500 metaphases showed 50% misclassification with the manual scoring on 50 metaphases. Comparison between the dose classifications obtained with the automatic scoring and manual scoring on 500 metaphases showed only 4.35% misclassification with the automatic scoring. The automatic scoring method is more accurate than the manual scoring on 50 metaphases and can therefore be used for triage, and in place of the manual scoring on 500 metaphases method for individual dose estimation, because it is as accurate and much faster.
DNA Repair | 2013
Ingrid Nosel; Aurélie Vaurijoux; Joan Francesc Barquinero; Gaëtan Gruel
The aim of the present study is to analyse by microarray techniques how gene expression is modulated after exposure to low and very low doses of ionizing radiation, to evaluate if the pattern of gene expression shows dose dependence, and to search for putative regulatory mechanisms behind the observed gene-expression modifications. For this, whole blood samples from five healthy donors were exposed in six doses between 5 and 500mGy. Total RNA extraction from CD4(+) lymphocytes was done at four different post-irradiation times. After mRNA amplification, aRNAs were hybridized on DNA microarrays. The results indicated that up-regulation was twice than down-regulation. Surprisingly, the number of modulated genes does not seem to change drastically with dose, even at the lowest dose of 5mGy. Clustering analysis revealed seven gene expression clusters with different dose dependence profiles. The functional analysis showed that the genes which increased their expression with the dose were related to p53 pathway and DNA damage response. This could be observed from 25mGy, but became very clear at doses equal or greater than 100mGy. On the other hand, genes with a constant modulation of their expression in all the tested doses were related to cellular respiration, ATP metabolic process and chromatin organization. These latter molecular mechanisms seem to be triggered at very low doses (5-25mGy). In silico promoter analysis seems to confirm the implication of transcription factors related to the pathways mentioned above.
Radiation Research | 2008
Gaëtan Gruel; Pascale Voisin; Aurélie Vaurijoux; Sandrine Roch-Lefèvre; Eric Gregoire; Peggy Maltère; Cyrille Petat; Xavier Gidrol; Philippe Voisin; Laurence Roy
Abstract Gruel, G., Voisin, P., Vaurijoux, A., Roch-Lefèvre, S., Gré goire, E., Maltère, P., Petat, C., Gidrol, X., Voisin, P. and Roy, L. Broad Modulation of Gene Expression in CD4+ Lymphocyte Subpopulations in Response to Low Doses of Ionizing Radiation. Radiat. Res. 170, 335–344 (2008). To compare the responses of the different lymphocyte subtypes after an exposure of whole blood to low doses of ionizing radiation, we examined variations in gene expression in different lymphocyte subpopulations using microarray technology. Blood samples from five healthy donors were independently exposed to 0 (sham irradiation), 0.05 and 0.5 Gy of ionizing radiation. Three and 24 h after exposure, CD56+, CD4+ and CD8+ cells were negatively isolated. RNA from each set of experimental conditions was competitively hybridized on 25k oligonucleotide microarrays. Modifications of gene expression were measured after both intervals and in all cell types. Twenty-four hours after exposure to 0.5 Gy, we observed an induction of the expression of BAX, PCNA, GADD45, DDB2 and CDKN1A. However, the numbers of modulated genes greatly differed between cell types. In particular, 3 h after exposure to doses as low as 0.05 Gy, the number of down-modulated genes was 10 times greater for CD4+ cells than for all other cell types. Moreover, most of these repressed genes were taking part in the cell processes of protein biosynthesis and oxidative phosphorylation. The results suggest that several biological pathways in CD4+ cells could be sensitive to low doses of radiation. Therefore, specifically studying CD4+ cells could help to understand the mechanisms involved in low-dose response and allow their detection.
Radiation Research | 2012
Aurélie Vaurijoux; Eric Gregoire; Sandrine Roch-Lefèvre; Pascale Voisin; Cécile Martin; Philippe Voisin; Laurence Roy; Gaëtan Gruel
In accidental exposure to ionizing radiation, it is essential to estimate the dose received by the victims. Currently dicentric scoring is the best biological indicator of exposure. The standard biological dosimetry procedure (500 metaphases scored manually) is suitable for a few dose estimations, but the time needed for analysis can be problematic in the case of a large-scale accident. Recently, a new methodology using automatic detection of dicentrics has greatly decreased the time needed for dose estimation and preserves the accuracy of the estimation. However, the capability to detect nonhomogeneous partial-body exposures is an important advantage of dicentric scoring-based biodosimetry, and this remains to be tested with automatic scoring. Thus we analyzed the results obtained with in vitro blood dilutions and in real cases of accidental exposure (partial- or whole-body exposure) using manual scoring and automatic detection of dicentrics. We confirmed that automatic detection allows threefold quicker dicentric scoring than the manual procedure with similar dose estimations and uncertainty intervals. The results concerning partial-body exposures were particularly promising, and homogeneously exposed samples were correctly distinguished from heterogeneously exposed samples containing 5% to 75% of blood irradiated with 2 Gy. In addition, the results obtained for real accident cases were similar whatever the methodology used. This study demonstrates that automatic detection of dicentrics is a credible alternative for recent and acute cases of whole- and partial-body accidental exposures to ionizing radiation.
Radiation Research | 2013
Gaëtan Gruel; Eric Gregoire; Sarah Lecas; Cécile Martin; Sandrine Roch-Lefèvre; Aurélie Vaurijoux; Pascale Voisin; Philippe Voisin; Joan Francesc Barquinero
Dicentric chromosome analysis remains the most widely used method in biodosimetry. It has a lower detection limit of about 0.1 Gy, and allows one to distinguish between whole- and partial-body exposures. A drawback of the dicentric analysis is that it is a time consuming method and maybe difficult to implement in a mass casualty event. To try to increase the analysis capacity, automatic dicentric scoring (ADS) using image analysis software is being incorporated in several laboratories. Here we present the results obtained in an emergency exercise simulating 50 victims. The ability to distinguish different radiations scenarios is evaluated. To simulate whole-body exposures peripheral blood samples were irradiated at doses between 0–4.7 Gy, and to simulate partial-body exposures irradiated and nonirradiated blood were mixed in different proportions. With the data obtained from the first slide analyzed (with about 300–400 cells), 32 of 34 simulated whole-body exposures were correctly classified according to radiation exposure levels. For simulated partial-body irradiations, it was possible to detect them as partial exposures at the end of the first slide analyzed but only at the highest doses. In all cases the classification was updated every time the analysis of one additional slide was finished. The comparison between our present results and those reported in the literature for manual scoring shows that for triage purposes the ADS based on 300–400 cells is similar in efficiency to classifying the cases based on manual scoring of 50 cells. However, if one accounts for the associated uncertainties and the time needed for ADS, we suggest that ADS triage scoring should be based on about 1,000 cells. For final dose estimations the number of cells to score will depend on the initial estimated dose, and on the information contributed from physical dose-reconstruction or clinical symptoms. At doses higher than 1 Gy, we propose analysis of 1,500 and for lower doses or suspected partial-body exposures, the number of cells to score should be 3,000.
Radiation Protection Dosimetry | 2013
Eric Gregoire; Valeria Hadjidekova; Rositsa Hristova; Gaëtan Gruel; Sandrine Roch-Lefèvre; P. Voisin; Albena Staynova; S. Deleva; Elizabeth A. Ainsbury; David C. Lloyd; Joan Francesc Barquinero
In 2011, a serious radiation accident occurred in Stamboliyski, Bulgaria, in an industrial sterilisation facility using very-high-activity (60)Co sources. For the five persons accidentally exposed, biological dosimetry based on dicentric analysis was performed in Sofia and in Paris, where the patients were transferred for treatment. Before completing the chromosomal dose assessment, and for the most exposed person, a preliminary cytogenetic evaluation based on electronically transmitted metaphase images was made. The averaged acute whole-body dose estimates for the five patients ranged from 5.2 to 1.2 Gy, and good agreement was obtained between the two laboratories. The patients were also assessed by their prodromal responses and depressed blood cell counts over the first week. The cytogenetic dose estimates were in good accord with those derived from the blood counts, and both techniques indicated that, for the two most seriously exposed persons both techniques indicated that the initial prodromal reactions had suggested somewhat less severe exposure.
PLOS ONE | 2016
Gaëtan Gruel; Carmen Villagrasa; Pascale Voisin; I. Clairand; Marc Benderitter; J.-F. Bottollier-Depois; Joan Francesc Barquinero
Most studies that aim to understand the interactions between different types of photon radiation and cellular DNA assume homogeneous cell irradiation, with all cells receiving the same amount of energy. The level of DNA damage is therefore generally determined by averaging it over the entire population of exposed cells. However, evaluating the molecular consequences of a stochastic phenomenon such as energy deposition of ionizing radiation by measuring only an average effect may not be sufficient for understanding some aspects of the cellular response to this radiation. The variance among the cells associated with this average effect may also be important for the behaviour of irradiated tissue. In this study, we accurately estimated the distribution of the number of radiation-induced γH2AX foci (RIF) per cell nucleus in a large population of endothelial cells exposed to 3 macroscopic doses of gamma rays from 60Co. The number of RIF varied significantly and reproducibly from cell to cell, with its relative standard deviation ranging from 36% to 18% depending on the macroscopic dose delivered. Interestingly, this relative cell-to-cell variability increased as the dose decreased, contrary to the mean RIF count per cell. This result shows that the dose effect, in terms of the number of DNA lesions indicated by RIF is not as simple as a purely proportional relation in which relative SD is constant with dose. To analyse the origins of this observed variability, we calculated the spread of the specific energy distribution for the different target volumes and subvolumes in which RIF can be generated. Variances, standard deviations and relative standard deviations all changed similarly from dose to dose for biological and calculated microdosimetric values. This similarity is an important argument that supports the hypothesis of the conservation of the association between the number of RIF per nucleus and the specific energy per DNA molecule. This comparison allowed us to calculate a volume of 1.6 μm3 for which the spread of the specific energy distribution could explain the entire variability of RIF counts per cell in an exposed cell population. The definition of this volume may allow to use a microdosimetric quantity to predict heterogeneity in DNA damage. Moreover, this value is consistent with the order of magnitude of the volume occupied by the hydrated sugar-phosphate backbone of the DNA molecule, which is the part of the DNA molecule responsible for strand breaks.
Radiation Protection Dosimetry | 2014
M. Dos Santos; I. Clairand; Gaëtan Gruel; Joan Francesc Barquinero; S. Incerti; Carmen Villagrasa
The purpose of this work is to evaluate the influence of the chromatin condensation on the number of direct double-strand break (DSB) damages induced by ions. Two geometries of chromosome territories containing either condensed or decondensed chromatin were implemented as biological targets in the Geant4 Monte Carlo simulation code and proton and alpha irradiation was simulated using the Geant4-DNA processes. A DBSCAN algorithm was used in order to detect energy deposition clusters that could give rise to single-strand breaks or DSBs on the DNA molecule. The results of this study show an increase in the number and complexity of DNA DSBs in condensed chromatin when compared with decondensed chromatin.
Journal of Applied Toxicology | 2014
Nicholas Synhaeve; Ndéye Marième Wade‐Gueye; Stefania Musilli; Johanna Stefani; Line Grandcolas; Gaëtan Gruel; Maâmar Souidi; Isabelle Dublineau; Jean-Marc Bertho
The aim of this work was to delineate the effects of chronic ingestion of strontium 90 (90Sr) at low concentrations on the hematopoiesis and the bone physiology. A mouse model was used for that purpose. Parent animals ingested water containing 20 kBq l−1 of 90Sr two weeks before mating. Offspring were then continuously contaminated with 90Sr through placental transfer during fetal life, through lactation after birth and through drinking water after weaning. At various ages between birth and 20 weeks, animals were tested for hematopoietic parameters such as blood cell counts, colony forming cells in spleen and bone marrow and cytokine concentrations in the plasma. However, we did not find any modification in 90Sr ingesting animals as compared with control animals. By contrast, the analysis of bone physiology showed a modification of gene expression towards bone resorption. This was confirmed by an increase in C‐telopeptide of collagen in the plasma of 90Sr ingesting animals as compared with control animals. This modification in bone metabolism was not linked to a modification of the phosphocalcic homeostasis, as measured by calcium, phosphorus, vitamin D and parathyroid hormone in the blood. Overall these results suggest that the chronic ingestion of 90Sr at low concentration in the long term may induce modifications in bone metabolism but not in hematopoiesis. Copyright
Radiation Protection Dosimetry | 2012
Laurence Roy; Eric Gregoire; Gaëtan Gruel; Sandrine Roch-Lefèvre; Pa. Voisin; A. Busset; C. Martin; Ph. Voisin
Fundamentals of biological dosimetry are described in the International Atomic Energy Agency manual, but all over the world each laboratory is using its own protocol. To test the influence of protocol variations, some blood samples were exposed to 0.5 Gy of gamma radiation and mitotic index and dicentric rates were measured under different experimental conditions. The effect of seven parameters [bromodeoxyuridin (BrdU), phytohaemagglutinin and colcemid concentrations, blood and medium volumes, culture duration and incubation temperature] was tested using a Placket and Burman experimental design. The analysis reveals that the mitotic index was influenced by the concentration of BrdU, medium and blood volumes, the culture duration and the temperature. However, none of the factors has a significant impact on the yield of dicentrics. The dicentric assay is robust against reagent variations within the range tested. These results could be used by relevant laboratories as elements of their procedures robustness in any event requiring such demonstration.