Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Gary A. Sneiderman is active.

Publication


Featured researches published by Gary A. Sneiderman.


Proceedings of SPIE | 2016

The Astro-H High Resolution Soft X-Ray Spectrometer

Richard L. Kelley; Hiroki Akamatsu; Phillipp Azzarell; Tom Bialas; Gregory V. Brown; Edgar Canavan; Meng P. Chiao; E. Costantini; Michael DiPirro; Megan E. Eckart; Yuichiro Ezoe; Ryuichi Fujimoto; D. Haas; Jan Willem den Herder; Akio Hoshino; Kumi Ishikawa; Yoshitaka Ishisaki; Naoko Iyomoto; Caroline A. Kilbourne; Mark O. Kimball; Shunji Kitamoto; Saori Konami; Shu Koyama; Maurice A. Leutenegger; Dan McCammon; Joseph Miko; Kazuhisa Mitsuda; Ikuyuki Mitsuishi; Harvey Moseley; Hiroshi Murakami

We present the overall design and performance of the Astro-H (Hitomi) Soft X-Ray Spectrometer (SXS). The instrument uses a 36-pixel array of x-ray microcalorimeters at the focus of a grazing-incidence x-ray mirror Soft X-Ray Telescope (SXT) for high-resolution spectroscopy of celestial x-ray sources. The instrument was designed to achieve an energy resolution better than 7 eV over the 0.3-12 keV energy range and operate for more than 3 years in orbit. The actual energy resolution of the instrument is 4-5 eV as demonstrated during extensive ground testing prior to launch and in orbit. The measured mass flow rate of the liquid helium cryogen and initial fill level at launch predict a lifetime of more than 4 years assuming steady mechanical cooler performance. Cryogen-free operation was successfully demonstrated prior to launch. The successful operation of the SXS in orbit, including the first observations of the velocity structure of the Perseus cluster of galaxies, demonstrates the viability and power of this technology as a tool for astrophysics.


Proceedings of SPIE | 2014

Soft x-ray spectrometer (SXS): The high-resolution cryogenic spectrometer onboard ASTRO-H

Kazuhisa Mitsuda; Richard L. Kelley; Hiroki Akamatsu; Thomas G. Bialas; Gregory V. Brown; Edgar Canavan; Meng Chiao; E. Costantini; Jan Willem den Herder; Cor P. de Vries; Michael DiPirro; Megan E. Eckart; Yuichiro Ezoe; Ryuichi Fujimoto; D. Haas; Akio Hoshino; Kumi Ishikawa; Yoshitaka Ishisaki; Naoko Iyomoto; Caroline A. Kilbourne; Mark O. Kimball; Shunji Kitamoto; Saori Konami; M. A. Leutenegger; Dan McCammon; Joseph Miko; Ikuyuki Mitsuishi; Hiroshi Murakami; Masahide Murakami; Hirofumi Noda

We present the development status of the Soft X-ray Spectrometer (SXS) onboard the ASTRO-H mission. The SXS provides the capability of high energy-resolution X-ray spectroscopy of a FWHM energy resolution of < 7eV in the energy range of 0.3 – 10 keV. It utilizes an X-ray micorcalorimeter array operated at 50 mK. The SXS microcalorimeter subsystem is being developed in an EM-FM approach. The EM SXS cryostat was developed and fully tested and, although the design was generally confirmed, several anomalies and problems were found. Among them is the interference of the detector with the micro-vibrations from the mechanical coolers, which is the most difficult one to solve. We have pursued three different countermeasures and two of them seem to be effective. So far we have obtained energy resolutions satisfying the requirement with the FM cryostat.


Proceedings of SPIE | 2016

In-orbit operation of the ASTRO-H SXS

Masahiro Tsujimoto; Kazuhisa Mitsuda; Richard L. Kelley; Jan Willem den Herder; Hiroki Akamatsu; Thomas G. Bialas; Gregory V. Brown; Meng P. Chiao; E. Costantini; Cor P. de Vries; Michael DiPirro; Megan E. Eckart; Yuichiro Ezoe; Ryuichi Fujimoto; D. Haas; Akio Hoshino; Kumi Ishikawa; Yoshitaka Ishisaki; Naoko Iyomoto; Caroline A. Kilbourne; Shunji Kitamoto; Shu Koyama; Maurice A. Leutenegger; Dan McCammon; Ikuyuki Mitsuishi; Hiroshi Murakami; Masahide Murakami; Hirofumi Noda; Mina Ogawa; Naomi Ota

We summarize all the in-orbit operations of the Soft X-ray Spectrometer (SXS) onboard the ASTRO-H (Hit- omi) satellite. The satellite was launched on 2016/02/17 and the communication with the satellite ceased on 2016/03/26. The SXS was still in the commissioning phase, in which the setups were progressively changed. This article is intended to serve as a reference of the events in the orbit to properly interpret the SXS data taken during its short life time, and as a test case for planning the in-orbit operation for future micro-calorimeter missions.


Proceedings of SPIE | 2016

Performance of the helium dewar and cryocoolers of ASTRO-H SXS

Ryuichi Fujimoto; Yoh Takei; Kazuhisa Mitsuda; Noriko Y. Yamasaki; Masahiro Tsujimoto; Shu Koyama; Kumi Ishikawa; Hiroyuki Sugita; Yoichi Sato; Keisuke Shinozaki; Atsushi Okamoto; Shunji Kitamoto; Akio Hoshino; Kosuke Sato; Yuichiro Ezoe; Yoshitaka Ishisaki; S. Yamada; Hiromi Seta; Takaya Ohashi; Toru Tamagawa; Hirofumi Noda; Makoto Sawada; Makoto Tashiro; Yoichi Yatsu; Ikuyuki Mitsuishi; Kenichi Kanao; Seiji Yoshida; Mikio Miyaoka; Shoji Tsunematsu; Kiyomi Otsuka

The Soft X-ray Spectrometer (SXS) is a cryogenic high-resolution X-ray spectrometer onboard the ASTRO-H satellite, that achieves energy resolution better than 7 eV at 6 keV, by operating the detector array at 50 mK using an adiabatic demagnetization refrigerator. The cooling chain from room temperature to the ADR heat sink is composed of 2-stage Stirling cryocoolers, a 4He Joule-Thomson cryocooler, and super uid liquid He, and is installed in a dewar. It is designed to achieve a helium lifetime of more than 3 years with a minimum of 30 liters. The satellite was launched on 2016 February 17, and the SXS worked perfectly in orbit, until March 26 when the satellite lost its function. It was demonstrated that the heat load on the He tank was about 0.7 mW, which would have satisfied the lifetime requirement. This paper describes the design, results of ground performance tests, prelaunch operations, and initial operation and performance in orbit of the flight dewar and cryocoolers.


Proceedings of SPIE | 2016

In-flight performance of the Soft X-ray Spectrometer detector system on Astro-H

F. S. Porter; Meng P. Chiao; Megan E. Eckart; Ryuichi Fujimoto; Yoshitaka Ishisaki; Richard L. Kelley; Caroline A. Kilbourne; Maurice A. Leutenegger; Dan McCammon; Kazuhisa Mitsuda; Kosuke Sato; Hiromi Seta; Makoto Sawada; Gary A. Sneiderman; Andrew E. Szymkowiak; Yoh Takei; Makoto Tashiro; Masahiro Tsujimoto; Tomomi Watanabe; S. Yamada

The SXS instrument was launched aboard the Astro-H observatory on February 17, 2016. The SXS spectrometer is based on a high sensitivity x-ray calorimeter detector system that has been successfully deployed in many ground and sub-orbital spectrometers. The instrument was to provide essential diagnostics for nearly every class of x-ray emitting objects from the atmosphere of Jupiter to the outskirts of galaxy clusters, without degradation for spatially extended objects. The SXS detector system consisted of a 36-pixel cryogenic microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the detector system demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous band-pass from below 0.3 keV to above 12 keV with a timing precision better than 100 μs. In addition, a solid-state anti-coincidence detector was placed directly behind the detector array for background suppression. The detector error budget included the measured interference from the SXS cooling system and the spacecraft. Additional margin for on-orbit gain-stability, and on-orbit spacecraft interference were also included predicting an on-orbit performance that meets or exceeds the 7 eV FWHM at 6 keV requirement. The actual on-orbit spectral resolution was better than 5 eV FWHM at 6 keV, easily satisfying the instrument requirement. Here we discuss the actual on-orbit performance of the SXS detector system and compare this to performance in pre-flight testing and the on-orbit predictions. We will also discuss the on-orbit gain stability, additional on-orbit interference, and measurements of the on-orbit background.


Proceedings of SPIE | 2010

Cooling system for the soft x-ray spectrometer (SXS) onboard ASTRO-H

Ryuichi Fujimoto; Kazuhisa Mitsuda; Noriko Y. Yamasaki; Yoh Takei; Masahiro Tsujimoto; Hiroyuki Sugita; Yoichi Sato; Keisuke Shinozaki; Atsushi Okamoto; Takaya Ohashi; Yoshitaka Ishisaki; Yuichiro Ezoe; Kumi Ishikawa; Masahide Murakami; Shunji Kitamoto; Hiroshi Murakami; Toru Tamagawa; Madoka Kawaharada; Hiroya Yamaguchi; Kosuke Sato; Akio Hoshino; Kenichi Kanao; Seiji Yoshida; Mikio Miyaoka; Michael DiPirro; Peter J. Shirron; Gary A. Sneiderman; Richard L. Kelley; F. Scott Porter; Caroline A. Kilbourne

The Soft X-ray Spectrometer (SXS) is a cryogenic high resolution X-ray spectrometer onboard the X-ray astronomy satellite ASTRO-H. The detector array is cooled down to 50 mK using a 3-stage adiabatic demagnetization refrigerator (ADR). The cooling chain from room temperature to the ADR heat-sink is composed of superfluid liquid He, a 4He Joule-Thomson cryocooler, and 2-stage Stirling cryocoolers. It is designed to keep 30 L of liquid He for more than 3 years in the nominal case. It is also designed with redundant subsystems throughout from room temperature to the ADR heat-sink, to alleviate failure of a single cryocooler or loss of liquid He.


Proceedings of SPIE | 2016

Design and on-orbit operation of the adiabatic demagnetization refrigerator on the Hitomi Soft X-ray Spectrometer instrument

Peter J. Shirron; Mark O. Kimball; Bryan L. James; Theodore Muench; Edgar Canavan; Michael DiPirro; Thomas G. Bialas; Gary A. Sneiderman; Caroline A. Kilbourne; F. S. Porter; Richard L. Kelley; Ryuichi Fujimoto; Yoh Takei; Seiji Yoshida; Kazuhisa Mitsuda

The Soft X-ray Spectrometer instrument on the Astro-H observatory contains a 6x6 array of x-ray microcalorimeters, which is cooled to 50 mK by an adiabatic demagnetization refrigerator (ADR). The ADR consists of three stages in order to provide stable detector cooling using either a 1.2 K superfluid helium bath or a 4.5 K Joule-Thomson (JT) cryocooler as its heat sink. When liquid helium is present, two of the ADR’s stages are used to single-shot cool the detectors while rejecting heat to the helium. After the helium is depleted, all three stages are used to cool both the helium tank (to about 1.5 K) and the detectors (to 50 mK) using the JT cryocooler as its heat sink. The Astro-H observatory, renamed Hitomi after its successful launch in February 2016, carried approximately 36 liters of helium into orbit. On day 5, the helium had cooled sufficiently (<1.4 K) to allow operation of the ADR. This paper describes the design, operation and on-orbit performance of the ADR.


Proceedings of SPIE | 2016

Ground Calibration of the Astro-H (Hitomi) Soft X-Ray Spectrometer

Megan E. Eckart; Joseph S. Adams; G. V. Brown; Meng P. Chiao; Ryuichi Fujimoto; D. Haas; J. W. den Herder; Yoshitaka Ishisaki; R. L. Kelley; Caroline A. Kilbourne; Maurice A. Leutenegger; D. McCammon; K. Mitsuda; F. S. Porter; Kosuke Sato; Makoto Sawada; Hiromi Seta; Gary A. Sneiderman; Andrew E. Szymkowiak; Yoh Takei; Makoto Tashiro; Masahiro Tsujimoto; C. P. de Vries; Tomomi Watanabe; S. Yamada; Noriko Y. Yamasaki

The Astro-H (Hitomi) Soft X-ray Spectrometer (SXS) was a pioneering imaging x-ray spectrometer with 5 eV energy resolution at 6 keV. The instrument used a microcalorimeter array at the focus of a high-throughput soft x-ray telescope to enable high-resolution non-dispersive spectroscopy in the soft x-ray waveband (0:3-12 keV). We present the suite of ground calibration measurements acquired from 2012-2015, including characterization of the detector system, anti-coincidence detector, optical blocking filters, and filter-wheel filters. The calibration of the 36-pixel silicon thermistor microcalorimeter array includes parameterizations of the energy gain scale and line spread function for each event grade over a range of instrument operating conditions, as well as quantum efficiency measurements. The x-ray transmission of the set of five Al/polyimide thin-film optical blocking filters mounted inside the SXS dewar has been modeled based on measurements at synchrotron beamlines, including with high spectral resolution at the C, N, O, and Al K-edges. In addition, we present the x-ray transmission of the dewar gate valve and of the filters mounted on the SXS filter wheel (external to the dewar), including beryllium, polyimide, and neutral density filters.


Proceedings of SPIE | 2016

Vibration isolation system for cryocoolers of Soft X-ray Spectrometer (SXS) onboard ASTRO-H (Hitomi)

Yoh Takei; Susumu Yasuda; Kosei Ishimura; Naoko Iwata; Atsushi Okamoto; Yoichi Sato; Mina Ogawa; Makoto Sawada; Taro Kawano; Shingo Obara; Chikara Natsukari; Atsushi Wada; S. Yamada; Ryuichi Fujimoto; Motohide Kokubun; Noriko Y. Yamasaki; Hiroyuki Sugita; Kenji Minesugi; Yasuo Nakamura; Kazuhisa Mitsuda; Tadayuki Takahashi; Seiji Yoshida; Shoji Tsunematsu; Kenichi Kanao; Katsuhiro Narasaki; Kiyomi Otsuka; Richard L. Kelley; F. Scott Porter; Caroline A. Kilbourne; Meng P. Chiao

Soft X-ray Spectrometer (SXS) onboard ASTRO-H (named Hitomi after launch) is a microcalorimeter-type spectrometer, installed in a dewar to be cooled at 50 mK. The energy resolution of the SXS engineering model suffered from micro-vibration from cryocoolers mounted on the dewar. This is mitigated for the flight model by introducing vibration isolation systems between the cryocoolers and the dewar. The detector performance of the flight model was verified before launch of the spacecraft in both ambient condition and thermal-vac condition, showing no detectable degradation in energy resolution. The in-orbit performance was also consistent with that on ground, indicating that the cryocoolers were not damaged by launch environment. The design and performance of the vibration isolation system along with the mechanism of how the micro-vibration could degrade the cryogenic detector is shown.


Proceedings of SPIE | 2016

In-flight verification of the calibration and performance of the ASTRO-H (Hitomi) Soft X-Ray Spectrometer

Maurice A. Leutenegger; Marc Audard; Gregory V. Brown; Meng P. Chiao; Megan E. Eckart; Ryuichi Fujimoto; Akihiro Furuzawa; Matteo Guainazzi; D. Haas; Jan-Willem den Herder; Takayuki Hayashi; Ryo Iizuka; Manabu Ishida; Yoshitaka Ishisaki; Richard L. Kelley; Naomichi Kikuchi; Caroline A. Kilbourne; Shu Koyama; Sho Kurashima; Yoshitomo Maeda; Maxim Markevitch; Dan McCammon; Kazuhisa Mitsuda; Hideyuki Mori; Nozomi Nakaniwa; Takashi Okajima; Stephane Paltani; Robert Petre; F. Scott Porter; Kosuke Sato

The Soft X-ray Spectrometer (SXS) onboard the Astro-H (Hitomi) orbiting x-ray observatory featured an array of 36 silicon thermistor x-ray calorimeters optimized to perform high spectral resolution x-ray imaging spectroscopy of astrophysical sources in the 0.3-12 keV band. Extensive pre- flight calibration measurements are the basis for our modeling of the pulse-height-energy relation and energy resolution for each pixel and event grade, telescope collecting area, detector efficiency, and pulse arrival time. Because of the early termination of mission operations, we needed to extract the maximum information from observations performed only days into the mission when the onboard calibration sources had not yet been commissioned and the dewar was still coming into thermal equilibrium, so our technique for reconstructing the per-pixel time-dependent pulse-height-energy relation had to be modified. The gain scale was reconstructed using a combination of an absolute energy scale calibration at a single time using a fiducial from an onboard radioactive source, and calibration of a dominant time-dependent gain drift component using a dedicated calibration pixel, as well as a residual time-dependent variation using spectra from the Perseus cluster of galaxies. The energy resolution was also measured using the onboard radioactive sources. It is consistent with instrument-level measurements accounting for the modest increase in noise due to spacecraft systems interference. We use observations of two pulsars to validate our models of the telescope area and detector efficiency, and to derive a more accurate value for the thickness of the gate valve Be window, which had not been opened by the time mission operations ceased. We use observations of the Crab pulsar to refine the pixel-to-pixel timing and validate the absolute timing.

Collaboration


Dive into the Gary A. Sneiderman's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Richard L. Kelley

University of Wisconsin-Madison

View shared research outputs
Top Co-Authors

Avatar

Kazuhisa Mitsuda

Japan Aerospace Exploration Agency

View shared research outputs
Top Co-Authors

Avatar

Yoshitaka Ishisaki

Tokyo Metropolitan University

View shared research outputs
Top Co-Authors

Avatar

Yoh Takei

Japan Aerospace Exploration Agency

View shared research outputs
Top Co-Authors

Avatar

Michael DiPirro

Goddard Space Flight Center

View shared research outputs
Top Co-Authors

Avatar

Dan McCammon

University of Wisconsin-Madison

View shared research outputs
Top Co-Authors

Avatar

Megan E. Eckart

Lawrence Livermore National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Peter J. Shirron

Goddard Space Flight Center

View shared research outputs
Researchain Logo
Decentralizing Knowledge