Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where George A. Luiken is active.

Publication


Featured researches published by George A. Luiken.


Journal of Surgical Oncology | 2014

Fluorescently labeled chimeric anti-CEA antibody improves detection and resection of human colon cancer in a patient-derived orthotopic xenograft (PDOX) nude mouse model.

Cristina A. Metildi; Sharmeela Kaushal; George A. Luiken; Mark A. Talamini; Robert M. Hoffman; Michael Bouvet

The aim of this study was to evaluate a new fluorescently labeled chimeric anti‐CEA antibody for improved detection and resection of colon cancer.


BioTechniques | 2005

Facile whole-body imaging of internal fluorescent tumors in mice with an LED flashlight.

Meng Yang; George A. Luiken; Eugene Baranov; Robert M. Hoffman

Exposing the Inner Light The technology to use fluorescent markers to track the presence, growth, and metastasis of in situ tumors in mice has been around for a number of years. However, these meth...


Journal of The American College of Surgeons | 2012

An LED light source and novel fluorophore combinations improve fluorescence laparoscopic detection of metastatic pancreatic cancer in orthotopic mouse models.

Cristina A. Metildi; Sharmeela Kaushal; Claudia Lee; Chanae R. Hardamon; Cynthia S. Snyder; George A. Luiken; Mark A. Talamini; Robert M. Hoffman; Michael Bouvet

BACKGROUND The aim of this study was to improve fluorescence laparoscopy of pancreatic cancer in an orthotopic mouse model with the use of a light-emitting diode (LED) light source and optimal fluorophore combinations. STUDY DESIGN Human pancreatic cancer models were established with fluorescent FG-RFP, MiaPaca2-GFP, BxPC-3-RFP, and BxPC-3 cancer cells implanted in 6-week-old female athymic mice. Two weeks postimplantation, diagnostic laparoscopy was performed with a Stryker L9000 LED light source or a Stryker X8000 xenon light source 24 hours after tail-vein injection of CEA antibodies conjugated with Alexa 488 or Alexa 555. Cancer lesions were detected and localized under each light mode. Intravital images were also obtained with the OV-100 Olympus and Maestro CRI Small Animal Imaging Systems, serving as a positive control. Tumors were collected for histologic analysis. RESULTS Fluorescence laparoscopy with a 495-nm emission filter and an LED light source enabled real-time visualization of the fluorescence-labeled tumor deposits in the peritoneal cavity. The simultaneous use of different fluorophores (Alexa 488 and Alexa 555), conjugated to antibodies, brightened the fluorescence signal, enhancing detection of submillimeter lesions without compromising background illumination. Adjustments to the LED light source permitted simultaneous detection of tumor lesions of different fluorescent colors and surrounding structures with minimal autofluorescence. CONCLUSIONS Using an LED light source with adjustments to the red, blue, and green wavelengths, it is possible to simultaneously identify tumor metastases expressing fluorescent proteins of different wavelengths, which greatly enhanced the signal without compromising background illumination. Development of this fluorescence laparoscopy technology for clinical use can improve staging and resection of pancreatic cancer.


Hepato-gastroenterology | 2011

Tumor-specific fluorescence antibody imaging enables accurate staging laparoscopy in an orthotopic model of pancreatic cancer.

Hop S. Tran Cao; Sharmeela Kaushal; Cristina A. Metildi; Rhiana Menen; Claudia Lee; Cynthia S. Snyder; Karen Messer; Minya Pu; George A. Luiken; Mark A. Talamini; Robert M. Hoffman; Michael Bouvet

BACKGROUND/AIMS Laparoscopy is important in staging pancreatic cancer, but false negatives remain problematic. Making tumors fluorescent has the potential to improve the accuracy of staging laparoscopy. METHODOLOGY Orthotopic and carcinomatosis models of pancreatic cancer were established with BxPC-3 human pancreatic cancer cells in nude mice. Alexa488-antiCEA conjugates were injected via tail vein 24 hours prior to laparoscopy. Mice were examined under bright field laparoscopic (BL) and fluorescence laparoscopic (FL) modes. Outcomes measured included time to identification of primary tumor for the orthotopic model and number of metastases identified within 2 minutes for the carcinomatosis model. RESULTS FL enabled more rapid and accurate identification and localization of primary tumors and metastases than BL. Using BL took statistically significantly longer time than FL (p<0.0001, fold change and 95% CI for BL vs. FL: 8.12 (4.54,14.52)). More metastatic lesions were detected and localized under FL compared to BL and with greater accuracy, with sensitivities of 96% vs. 40%, respectively, when compared to control. FL was sensitive enough to detect metastatic lesions <1mm. CONCLUSIONS The use of fluorescence laparoscopy with tumors labeled with fluorophore-conjugated anti-CEA antibody permits rapid detection and accurate localization of primary and metastatic pancreatic cancer in an orthotopic model. The results of the present report demonstrate the future clinical potential of fluorescence laparoscopy.


PLOS ONE | 2014

Polyethylene glycol (PEG) linked to near infrared (NIR) dyes conjugated to chimeric anti-carcinoembryonic antigen (CEA) antibody enhances imaging of liver metastases in a nude-mouse model of human colon cancer.

Ali Maawy; Yukihiko Hiroshima; Yong Zhang; George A. Luiken; Robert M. Hoffman; Michael Bouvet

We report here that polyethylene glycol (PEG) linked to near infrared dyes conjugated to chimeric mouse-human anti-carcinoembryonic antigen (CEA) antibody greatly improves imaging of liver metastases in a nude mouse model of colon-cancer experimental metastases. PEGylated and non-PEGylated DyLight 650 and 750 dyes were conjugated to the chimeric anti-CEA antibody. The dyes were initially injected intravenously into nude mice without tumors. Tissue biodistribution was determined by tissue sonication and analyzing tissue dye concentration profiles over time. PEGylated dyes had significantly lower accumulation in the liver (p = 0.03 for the 650 dyes; p = 0.002 for the 750 dyes) compared to non-PEGylated dyes. In an experimental liver metastasis model of HT-29 colon cancer, PEGylated dyes conjugated to the anti-CEA antibody showed good labeling of metastatic tumors with high contrast between normal and malignant tissue which was not possible with the non-PEGylated dyes since there was so much non-specific accumulation in the liver. PEGylation of the DyLight 650 and 750 NIR dyes significantly altered tissue biodistribution, allowing brighter tissue labeling, decreased accumulation in normal organs, particularly the liver. This enabled high fidelity and high contrast imaging of liver metastases.


Journal of Biomedical Optics | 2013

Comparison of a chimeric anti-carcinoembryonic antigen antibody conjugated with visible or near-infrared fluorescent dyes for imaging pancreatic cancer in orthotopic nude mouse models

Ali Maawy; Yukihiko Hiroshima; Sharmeela Kaushal; George A. Luiken; Robert M. Hoffman; Michael Bouvet

Abstract. The aim of this study was to evaluate a set of visible and near-infrared dyes conjugated to a tumor-specific chimeric antibody for high-resolution tumor imaging in orthotopic models of pancreatic cancer. BxPC-3 human pancreatic cancer was orthotopically implanted into pancreata of nude mice. Mice received a single intravenous injection of a chimeric anti-carcinoembryonic antigen antibody conjugated to one of the following fluorophores: 488-nm group (Alexa Fluor 488 or DyLight 488); 550-nm group (Alexa Fluor 555 or DyLight 550); 650-nm group (Alexa Fluor 660 or DyLight 650), or the 750-nm group (Alexa Fluor 750 or DyLight 755). After 24 h, the Olympus OV100 small-animal imaging system was used for noninvasive and intravital fluorescence imaging of mice. Dyes were compared with respect to depth of imaging, resolution, tumor-to-background ratio (TBR), photobleaching, and hemoglobin quenching. The longer wavelength dyes had increased depth of penetration and ability to detect the smallest tumor deposits and provided the highest TBRs, resistance to hemoglobin quenching, and specificity. The shorter wavelength dyes were more photostable. This study showed unique advantages of each dye for specific cancer imaging in a clinically relevant orthotopic model.


PLOS ONE | 2015

Near Infra-Red Photoimmunotherapy with Anti-CEA-IR700 Results in Extensive Tumor Lysis and a Significant Decrease in Tumor Burden in Orthotopic Mouse Models of Pancreatic Cancer

Ali Maawy; Yukihiko Hiroshima; Yong Zhang; Roger Heim; Lew Makings; Miguel Garcia-Guzman; George A. Luiken; Hisataka Kobayashi; Robert M. Hoffman; Michael Bouvet

Photoimmunotherapy (PIT) of cancer utilizes tumor-specific monoclonal antibodies conjugated to a photosensitizer phthalocyanine dye IR700 which becomes cytotoxic upon irradiation with near infrared light. In this study, we aimed to evaluate the efficacy of PIT on human pancreatic cancer cells in vitro and in vivo in an orthotopic nude mouse model. The binding capacity of anti-CEA antibody to BxPC-3 human pancreatic cancer cells was determined by FACS analysis. An in vitro cytotoxicity assay was used to determine cell death following treatment with PIT. For in vivo determination of PIT efficacy, nude mice were orthotopically implanted with BxPC-3 pancreatic tumors expressing green fluorescent protein (GFP). After tumor engraftment, the mice were divided into two groups: (1) treatment with anti-CEA-IR700 + 690 nm laser and (2) treatment with 690 nm laser only. Anti-CEA-IR700 (100 μg) was administered to group (1) via tail vein injection 24 hours prior to therapy. Tumors were then surgically exposed and treated with phototherapy at an intensity of 150 mW/cm2 for 30 minutes. Whole body imaging was done subsequently for 5 weeks using an OV-100 small animal imaging system. Anti-CEA-IR700 antibody bound to the BxPC3 cells to a high degree as shown by FACS analysis. Anti-CEA-IR700 caused extensive cancer cell killing after light activation compared to control cells in cytotoxicity assays. In the orthotopic models of pancreatic cancer, the anti-CEA-IR700 group had significantly smaller tumors than the control after 5 weeks (p<0.001). There was no significant difference in the body weights of mice in the anti-CEA-IR700 and control groups indicating that PIT was well tolerated by the mice.


Journal of Surgical Research | 2015

Photoimmunotherapy lowers recurrence after pancreatic cancer surgery in orthotopic nude mouse models

Ali Maawy; Yukihiko Hiroshima; Yong Zhang; Miguel Garcia-Guzman; George A. Luiken; Hisataka Kobayashi; Robert M. Hoffman; Michael Bouvet

BACKGROUND Photoimmunotherapy (PIT) is based on the use of a monoclonal antibody specific to cancer epitopes conjugated to a photosensitizer near-infrared phthalocyanine dye (IR700). In this study, PIT with IR700 conjugated to anti-carcinoembryonic antigen (CEA) was used as an adjunct to surgery in orthotopically-implanted human pancreatic cancer in a nude mouse model to eliminate microscopic disease in the post-surgical tumor bed and prevent local as well as metastatic recurrence. MATERIALS AND METHODS Athymic nude mice were orthotopically implanted with the human pancreatic cancer cell line BxPC3 expressing green fluorescent protein. After tumor engraftment, the mice were divided into two groups as follows: bright light surgery (BLS) + anti-CEA-IR700 + 690 nm laser (PIT); and BLS only. Anti-CEA-IR700 (100 μg) was administered to the treatment group via tail-vein injection 24 h before therapy. Tumors were resected, and the surgical bed was treated with intraoperative phototherapy at an intensity of 150 mW/cm(2) for 30 min. Mice were imaged noninvasively for 8 wk using an OV-100 small animal fluorescence imager. RESULTS BLS + PIT reduced local recurrence to 1/7 mice from 7/7 mice with BLS-only (P = 0.001) and metastatic recurrence to 2/7 mice compared with 6/7 mice with BLS-only (P = 0.03). Local tumor growth continued at a rapid rate after BLS-only compared with BLS + PIT where almost no local growth occurred. There was a significant difference in tumor size between mice in the BLS + PIT (2.14 mm(2), 95% confidence interval [CI] [-2.06 to 6.34] and BLS-only groups (115.2 mm(2), 95% CI [88.8-141.6]) at 6 wk after surgery (P < 0.001). There was also a significant difference in tumor weight between the BLS + PIT group (6.65 mg, 95% CI [-6.35 to 19.65] and BLS-only group (1100 mg, 95% CI [794-1406] at 8 wk after surgery (P < 0.001). CONCLUSIONS PIT holds promise in the treatment of pancreatic cancer and may serve as a useful adjunct to surgery in the eradication of microscopic residual disease that can lead to both local and metastatic recurrence. Further studies are warranted to investigate the potential toxicities of PIT, especially with regard to anastomoses, such as those involved in pancreaticoduodenectomy.


Cancer Research | 2014

Abstract 4306: Bioconjugation of near infrared dyes by PEGylation improves pharmacokinetics and allows for better labeling and imaging of human gastrointestinal cancers

Ali Maawy; Yukihiko Hiroshima; George A. Luiken; Yong Zhang; Robert M. Hoffman; Michael Bouvet

NIR dyes are becoming increasingly popular due to their good tissue penetration, low tissue autofluorescence and resistance to hemoglobin quenching. However, they are still limited by lower hydrophilicity and poor chemical and photo-stability in-vivo. We aimed to try to improve these properties by covalent modification of these dyes by addition of polyethylene glycol (PEG) chains. We studied 2 commercially-available NIR dyes, DyLight 650 and 750, to evaluate how PEGylation affects the pharmacokinetics, biodistribution and imaging. PEGylated and non-PEGylated DyLight 650 and 750 dyes were conjugated to a chimeric anti-CEA antibody and were injected intravenously into nude mice. Serum samples were collected at various time points to determine serum concentrations and clearance kinetics. Biodistribution was determined by tissue sonication and analyzing tissue concentration profiles over time. PEGylated dyes had significantly higher serum concentrations than non-PEGylated dyes with p=0.005 for the 650 dyes and p Citation Format: Ali A. Maawy, Yukihiko Hiroshima, George A. Luiken, Yong Zhang, Robert M. Hoffman, Michael Bouvet. Bioconjugation of near infrared dyes by PEGylation improves pharmacokinetics and allows for better labeling and imaging of human gastrointestinal cancers. [abstract]. In: Proceedings of the 105th Annual Meeting of the American Association for Cancer Research; 2014 Apr 5-9; San Diego, CA. Philadelphia (PA): AACR; Cancer Res 2014;74(19 Suppl):Abstract nr 4306. doi:10.1158/1538-7445.AM2014-4306


Journal of Surgical Oncology | 2014

Fluorescently-labeled chimeric anti-CEA antibody improves detection and resection of human colon cancer in an orthotopic nude mouse model

Cristina A. Metildi; Sharmeela Kaushal; George A. Luiken; Mark A. Talamini; Robert M. Hoffman; Michael Bouvet

The aim of this study was to evaluate a new fluorescently labeled chimeric anti‐CEA antibody for improved detection and resection of colon cancer.

Collaboration


Dive into the George A. Luiken's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Michael Bouvet

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Ali Maawy

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Yong Zhang

University of California

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge