Publication


Featured researches published by Giada Acciaroli.


Diabetes Technology & Therapeutics | 2016

From Two to One Per Day Calibration of Dexcom G4 Platinum by a Time-Varying Day-Specific Bayesian Prior.

Giada Acciaroli; Martina Vettoretti; Andrea Facchinetti; Giovanni Sparacino; Claudio Cobelli

BACKGROUND In the DexCom G4 Platinum (DG4P) continuous glucose monitoring (CGM) sensor, the raw current signal generated by glucose-oxidase is transformed to glucose concentration by a calibration function whose parameters are periodically updated by matching self-monitoring of blood glucose references, usually twice a day, to compensate for sensor variability in time. The aim of this work is to reduce DG4P calibration frequency to once a day by a recently proposed Bayesian calibration algorithm, which employs a time-varying calibration function and suitable day-specific priors. METHODS The database consists of 57 CGM signals that are collected by the DG4P for 7 days. The Bayesian calibration algorithm is used to calibrate the raw current signal following two different schedules, that is, two and one calibration per day. Calibrated glycemic profiles are compared with those originally acquired by the manufacturer, on days 1, 4, and 7, where frequent blood glucose references were available, by using standard metrics, that is, mean absolute relative difference (MARD), percentage of accurate glucose estimates, and percentage of data in the A-zone of Clarke Error Grid. RESULTS The one per day Bayesian calibration algorithm has accuracy similar to that of two per day (11.8% vs. 11.7% MARD, respectively), and it is statistically better (P-value of 0.0411) than the manufacturer calibration algorithm, which requires two calibrations per day (13.1% MARD). CONCLUSIONS A Bayesian calibration algorithm employing a time-varying calibration function and suitable priors enables a reduction of the calibrations of DG4P sensor from two to one per day.


Biosensors | 2018

Calibration of Minimally Invasive Continuous Glucose Monitoring Sensors: State-of-The-Art and Current Perspectives

Giada Acciaroli; Martina Vettoretti; Andrea Facchinetti; Giovanni Sparacino

Minimally invasive continuous glucose monitoring (CGM) sensors are wearable medical devices that provide real-time measurement of subcutaneous glucose concentration. This can be of great help in the daily management of diabetes. Most of the commercially available CGM devices have a wire-based sensor, usually placed in the subcutaneous tissue, which measures a “raw” current signal via a glucose-oxidase electrochemical reaction. This electrical signal needs to be translated in real-time to glucose concentration through a calibration process. For such a scope, the first commercialized CGM sensors implemented simple linear regression techniques to fit reference glucose concentration measurements periodically collected by fingerprick. On the one hand, these simple linear techniques required several calibrations per day, with the consequent patient’s discomfort. On the other, only a limited accuracy was achieved. This stimulated researchers to propose, over the last decade, more sophisticated algorithms to calibrate CGM sensors, resorting to suitable signal processing, modelling, and machine-learning techniques. This review paper will first contextualize and describe the calibration problem and its implementation in the first generation of CGM sensors, and then present the most recently-proposed calibration algorithms, with a perspective on how these new techniques can influence future CGM products in terms of accuracy improvement and calibration reduction.


IEEE Transactions on Biomedical Engineering | 2018

Reduction of Blood Glucose Measurements to Calibrate Subcutaneous Glucose Sensors: A Bayesian Multiday Framework

Giada Acciaroli; Martina Vettoretti; Andrea Facchinetti; Giovanni Sparacino; Claudio Cobelli

Objective: In most continuous glucose monitoring (CGM) devices used for diabetes management, the electrical signal measured by the sensor is transformed to glucose concentration by a calibration function whose parameters are estimated using self-monitoring of blood glucose (SMBG) samples. The calibration function is usually a linear model approximating the nonlinear relationship between electrical signal and glucose concentration in certain time intervals. Thus, CGM devices require frequent calibrations, usually twice a day. The aim here is to develop a new method able to reduce the frequency of calibrations. Methods: The algorithm is based on a multiple-day model of sensor time-variability with second-order statistical priors on its unknown parameters. In an online setting, these parameters are numerically determined by the Bayesian estimation exploiting SMBG sparsely collected by the patient. The method is assessed retrospectively on 108 CGM signals acquired for 7 days by the Dexcom G4 Platinum sensor, testing progressively less-calibration scenarios. Results: Despite the reduction of calibration frequency (on average from 2/day to 0.25/day), the method shows a statistically significant accuracy improvement compared to manufacturer calibration, e.g., mean absolute relative difference when compared to a laboratory reference decreases from 12.83% to 11.62% (p-value of 0.006). Conclusion: The methodology maintains (sometimes improves) CGM sensor accuracy compared to that of the original manufacturer, while reducing the frequency of calibrations. Significance: Reducing the need of calibrations facilitates the adoption of CGM technology both in terms of ease of use and cost, an obvious prerequisite for its use as replacement of traditional SMBG devices.


Journal of diabetes science and technology | 2018

Diabetes and Prediabetes Classification Using Glycemic Variability Indices From Continuous Glucose Monitoring Data

Giada Acciaroli; Giovanni Sparacino; Liisa Hakaste; Andrea Facchinetti; Giorgio Maria Di Nunzio; Alessandro Palombit; Tiinamaija Tuomi; Rafael Gabriel; Jaime Aranda; Saturio Vega; Claudio Cobelli

Background: Tens of glycemic variability (GV) indices are available in the literature to characterize the dynamic properties of glucose concentration profiles from continuous glucose monitoring (CGM) sensors. However, how to exploit the plethora of GV indices for classifying subjects is still controversial. For instance, the basic problem of using GV indices to automatically determine if the subject is healthy rather than affected by impaired glucose tolerance (IGT) or type 2 diabetes (T2D), is still unaddressed. Here, we analyzed the feasibility of using CGM-based GV indices to distinguish healthy from IGT&T2D and IGT from T2D subjects by means of a machine-learning approach. Methods: The data set consists of 102 subjects belonging to three different classes: 34 healthy, 39 IGT, and 29 T2D subjects. Each subject was monitored for a few days by a CGM sensor that produced a glucose profile from which we extracted 25 GV indices. We used a two-step binary logistic regression model to classify subjects. The first step distinguishes healthy subjects from IGT&T2D, the second step classifies subjects into either IGT or T2D. Results: Healthy subjects are distinguished from subjects with diabetes (IGT&T2D) with 91.4% accuracy. Subjects are further subdivided into IGT or T2D classes with 79.5% accuracy. Globally, the classification into the three classes shows 86.6% accuracy. Conclusions: Even with a basic classification strategy, CGM-based GV indices show good accuracy in classifying healthy and subjects with diabetes. The classification into IGT or T2D seems, not surprisingly, more critical, but results encourage further investigation of the present research.


Computers in Biology and Medicine | 2018

Glycaemic variability-based classification of impaired glucose tolerance vs. type 2 diabetes using continuous glucose monitoring data

Enrico Longato; Giada Acciaroli; Andrea Facchinetti; Liisa Hakaste; Tiinamaija Tuomi; Alberto Maran; Giovanni Sparacino

Many glycaemic variability (GV) indices extracted from continuous glucose monitoring systems data have been proposed for the characterisation of various aspects of glucose concentration profile dynamics in both healthy and non-healthy individuals. However, the inter-index correlations have made it difficult to reach a consensus regarding the best applications or a subset of indices for clinical scenarios, such as distinguishing subjects according to diabetes progression stage. Recently, a logistic regression-based method was used to address the basic problem of differentiating between healthy subjects and those affected by impaired glucose tolerance (IGT) or type 2 diabetes (T2D) in a pool of 25 GV-based indices. Whereas healthy subjects were classified accurately, the distinction between patients with IGT and T2D remained critical. In the present work, by using a dataset of CGM time-series collected in 62 subjects, we developed a polynomial-kernel support vector machine-based approach and demonstrated the ability to distinguish between subjects affected by IGT and T2D based on a pool of 37 GV indices complemented by four basic parameters-age, sex, BMI, and waist circumference-with an accuracy of 87.1%.


Journal of diabetes science and technology | 2018

Continuous Glucose Monitoring: Current Use in Diabetes Management and Possible Future Applications

Martina Vettoretti; Giacomo Cappon; Giada Acciaroli; Andrea Facchinetti; Giovanni Sparacino

The recent announcement of the production of new low-cost continuous glucose monitoring (CGM) sensors, the approval of marketed CGM sensors for making treatment decisions, and new reimbursement criteria have the potential to revolutionize CGM use. After briefly summarizing current CGM applications, we discuss how, in our opinion, these changes are expected to extend CGM utilization beyond diabetes patients, for example, to subjects with prediabetes or even healthy individuals. We also elaborate on how the integration of CGM data with other relevant information, for example, health records and other medical device/wearable sensor data, will contribute to creating a digital data ecosystem that will improve our understanding of the etiology and complications of diabetes and will facilitate the development of data analytics for personalized diabetes management and prevention.


Electronics | 2017

Wearable Continuous Glucose Monitoring Sensors: A Revolution in Diabetes Treatment

Giacomo Cappon; Giada Acciaroli; Martina Vettoretti; Andrea Facchinetti; Giovanni Sparacino


Nutrition Metabolism and Cardiovascular Diseases | 2018

Head-To-Head Comparison of the accuracy of Abbott FreeStyle Libre and Dexcom G5 Mobile

Federico Boscari; Silvia Galasso; Giada Acciaroli; Andrea Facchinetti; Maria Cristina Marescotti; Angelo Avogaro; Daniela Bruttomesso


11th International Conference on Advanced Technologies and Treatments for Diabetes | 2018

IGT and T2D subjects automatically classified using a selection of CGM-based glycemic variability indices

Enrico Longato; Giada Acciaroli; Andrea Facchinetti; Liisa Hakaste; Tiinamaija Tuomi; Alberto Maran; Giovanni Sparacino


17th Annual Diabetes Technology Meeting | 2017

Bayesian calibration algorithm for next generation Dexcom sensor: 8.4% MARD with one calibration every 4 days

Giada Acciaroli; Martina Vettoretti; S. Vanslyke; Arturo Garcia; Andrea Facchinetti; Giovanni Sparacino

Collaboration


Dive into the Giada Acciaroli's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge