Publication


Featured researches published by Gregor Ochsner.


IEEE Transactions on Biomedical Engineering | 2013

A Novel Interface for Hybrid Mock Circulations to Evaluate Ventricular Assist Devices

Gregor Ochsner; Raffael Amacher; Alois Amstutz; André Plass; M. Schmid Daners; Hendrik T. Tevaearai; Stijn Vandenberghe; Markus J. Wilhelm; Lino Guzzella

This paper presents a novel mock circulation for the evaluation of ventricular assist devices (VADs), which is based on a hardware-in-the-loop concept. A numerical model of the human blood circulation runs in real time and computes instantaneous pressure, volume, and flow rate values. The VAD to be tested is connected to a numerical-hydraulic interface, which allows the interaction between the VAD and the numerical model of the circulation. The numerical-hydraulic interface consists of two pressure-controlled reservoirs, which apply the computed pressure values from the model to the VAD, and a flow probe to feed the resulting VAD flow rate back to the model. Experimental results are provided to show the proper interaction between a numerical model of the circulation and a mixed-flow blood pump.


Medical Physics | 2014

Development and evaluation of a prototype tracking system using the treatment couch

S. Lang; Jörg Zeimetz; Gregor Ochsner; Marianne Schmid Daners; Oliver Riesterer; Stephan Klöck

PURPOSE Tumor motion increases safety margins around the clinical target volume and leads to an increased dose to the surrounding healthy tissue. The authors have developed and evaluated a one-dimensional treatment couch tracking system to counter steer respiratory tumor motion. Three different motion detection sensors with different lag times were evaluated. METHODS The couch tracking system consists of a motion detection sensor, which can be the topometrical system Topos (Cyber Technologies, Germany), the respiratory gating system RPM (Varian Medical Systems) or a laser triangulation system (Micro Epsilon), and the Protura treatment couch (Civco Medical Systems). The control of the treatment couch was implemented in the block diagram environment Simulink (MathWorks). To achieve real time performance, the Simulink models were executed on a real time engine, provided by Real-Time Windows Target (MathWorks). A proportional-integral control system was implemented. The lag time of the couch tracking system using the three different motion detection sensors was measured. The geometrical accuracy of the system was evaluated by measuring the mean absolute deviation from the reference (static position) during motion tracking. This deviation was compared to the mean absolute deviation without tracking and a reduction factor was defined. A hexapod system was moving according to seven respiration patterns previously acquired with the RPM system as well as according to a sin(6) function with two different frequencies (0.33 and 0.17 Hz) and the treatment table compensated the motion. RESULTS A prototype system for treatment couch tracking of respiratory motion was developed. The laser based tracking system with a small lag time of 57 ms reduced the residual motion by a factor of 11.9 ± 5.5 (mean value ± standard deviation). An increase in delay time from 57 to 130 ms (RPM based system) resulted in a reduction by a factor of 4.7 ± 2.6. The Topos based tracking system with the largest lag time of 300 ms achieved a mean reduction by a factor of 3.4 ± 2.3. The increase in the penumbra of a profile (1 × 1 cm(2)) for a motion of 6 mm was 1.4 mm. With tracking applied there was no increase in the penumbra. CONCLUSIONS Couch tracking with the Protura treatment couch is achievable. To reliably track all possible respiration patterns without prediction filters a short lag time below 100 ms is needed. More scientific work is necessary to extend our prototype to tracking of internal motion.


Artificial Organs | 2014

A Physiological Controller for Turbodynamic Ventricular Assist Devices Based on a Measurement of the Left Ventricular Volume

Gregor Ochsner; Raffael Amacher; Markus J. Wilhelm; Stijn Vandenberghe; Hendrik T. Tevaearai; André Plass; Alois Amstutz; Volkmar Falk; Marianne Schmid Daners

The current article presents a novel physiological control algorithm for ventricular assist devices (VADs), which is inspired by the preload recruitable stroke work. This controller adapts the hydraulic power output of the VAD to the end-diastolic volume of the left ventricle. We tested this controller on a hybrid mock circulation where the left ventricular volume (LVV) is known, i.e., the problem of measuring the LVV is not addressed in the current article. Experiments were conducted to compare the response of the controller with the physiological and with the pathological circulation, with and without VAD support. A sensitivity analysis was performed to analyze the influence of the controller parameters and the influence of the quality of the LVV signal on the performance of the control algorithm. The results show that the controller induces a response similar to the physiological circulation and effectively prevents over- and underpumping, i.e., ventricular suction and backflow from the aorta to the left ventricle, respectively. The same results are obtained in the case of a disturbed LVV signal. The results presented in the current article motivate the development of a robust, long-term stable sensor to measure the LVV.


Artificial Organs | 2014

Synchronized Pulsatile Speed Control of Turbodynamic Left Ventricular Assist Devices: Review and Prospects

Raffael Amacher; Gregor Ochsner; Marianne Schmid Daners

Turbodynamic blood pumps are used clinically as ventricular assist devices (VADs). They are mostly operated at a constant rotational speed, which results in a reduced pulsatility. Previous research has analyzed pulsing pump speeds (speed modulation) to alter the interaction between the cardiovascular system and the blood pump. In those studies, sine- or square-wave speed profiles that were synchronized to the natural cardiac cycle were analyzed in silico, in vitro and in vivo. The definitions of these profiles with respect to both timing and speed levels vary among different research groups. The current paper provides a definition of the timing of these speed profiles such that the resulting hemodynamic effects become comparable. The results published in the literature are summarized and compared using this definition. Further, applied to a turbodynamic VAD, a series of measurements is conducted on a hybrid mock circulation using a constant speed as well as different types of square-wave speed profiles and a sine-wave speed profile. When a consistent definition of the timing of the speed profiles is used, the hemodynamic effects observed in previous work are in agreement with the measurement data obtained for the current paper. These findings allow the conclusion that the speed modulation of turbodynamic VADs represents a consistent tool to systematically change the ventricular load and the pulsatility in the arterial tree. The timing that yields the minimal left ventricular load also yields the minimal arterial pulse pressure.


IEEE Transactions on Biomedical Engineering | 2013

A Robust Reference Signal Generator for Synchronized Ventricular Assist Devices

Raffael Amacher; Gregor Ochsner; Antonio Ferreira; Stijn Vandenberghe; Marianne Schmid Daners

Ventricular assist devices (VADs) are blood pumps that offer an option to support the circulation of patients with severe heart failure. Since a failing heart has a remaining pump function, its interaction with the VAD influences the hemodynamics. Ideally, the hearts action is taken into account for actuating the device such that the device is synchronized to the natural cardiac cycle. To realize this in practice, a reliable real-time algorithm for the automatic synchronization of the VAD to the heart rate is required. This paper defines the tasks such an algorithm needs to fulfill: the automatic detection of irregular heart beats and the feedback control of the phase shift between the systolic phases of the heart and the assist device. We demonstrate a possible solution to these problems and analyze its performance in two steps. First, the algorithm is tested using the MIT-BIH arrhythmia database. Second, the algorithm is implemented in a controller for a pulsatile and a continuous-flow VAD. These devices are connected to a hybrid mock circulation where three test scenarios are evaluated. The proposed algorithm ensures a reliable synchronization of the VAD to the heart cycle, while being insensitive to irregularities in the heart rate.


Proceedings of the Institution of Mechanical Engineers, Part D: Journal of Automobile Engineering | 2012

In-cylinder boosting of turbocharged spark-ignited engines. Part 1: Model-based design of the charge valve

Christoph Voser; Christian Dönitz; Gregor Ochsner; Christopher H. Onder; Lino Guzzella

Downsizing and turbocharging for retaining the maximal power is a widely used approach to decrease the fuel consumption of spark ignited engines. In general, the trade-off is a substantial driveability loss. In-cylinder boosting has proven to be an effective way to eliminate this problem. Thus far, expensive and complex fully variable valve-trains have been proposed for the air exchange between the air tank and the combustion chamber. This paper is the first of a two-part study that examines the use of a deactivatable camshaft-driven valve with respect to the achievable transient engine performance. The system characteristics and limitations are discussed by using a mean value engine model that is adapted for in-cylinder boosting. A model-based design framework is presented which links the valve system design to a desired engine performance. The companion paper covers control issues and provides experimental verifications.


Artificial Organs | 2014

Analysis of Pressure Head-Flow Loops of Pulsatile Rotodynamic Blood Pumps

Silje Ekroll Jahren; Gregor Ochsner; Fangjun Shu; Raffael Amacher; James F. Antaki; Stijn Vandenberghe

The clinical importance of pulsatility is a recurring topic of debate in mechanical circulatory support. Lack of pulsatility has been identified as a possible factor responsible for adverse events and has also demonstrated a role in myocardial perfusion and cardiac recovery. A commonly used method for restoring pulsatility with rotodynamic blood pumps (RBPs) is to modulate the speed profile, synchronized to the cardiac cycle. This introduces additional parameters that influence the (un)loading of the heart, including the timing (phase shift) between the native cardiac cycle and the pump pulses, and the amplitude of speed modulation. In this study, the impact of these parameters upon the heart-RBP interaction was examined in terms of the pressure head-flow (HQ) diagram. The measurements were conducted using a rotodynamic Deltastream DP2 pump in a validated hybrid mock circulation with baroreflex function. The pump was operated with a sinusoidal speed profile, synchronized to the native cardiac cycle. The simulated ventriculo-aortic cannulation showed that the level of (un)loading and the shape of the HQ loops strongly depend on the phase shift. The HQ loops displayed characteristic shapes depending on the phase shift. Increased contribution of native contraction (increased ventricular stroke work [WS ]) resulted in a broadening of the loops. It was found that the previously described linear relationship between WS and the area of the HQ loop for constant pump speeds becomes a family of linear relationships, whose slope depends on the phase shift.


Asaio Journal | 2017

In Vivo Evaluation of Physiologic Control Algorithms for Left Ventricular Assist Devices Based on Left Ventricular Volume or Pressure

Gregor Ochsner; Markus J. Wilhelm; Raffael Amacher; Anastasios Petrou; Nikola Cesarovic; Silvan Staufert; Barbara Röhrnbauer; Francesco Maisano; Christofer Hierold; Mirko Meboldt; Marianne Schmid Daners

Turbodynamic left ventricular assist devices (LVADs) provide a continuous flow depending on the speed at which the pump is set, and do not adapt to the changing requirements of the patient. The limited adaptation of the pump flow to the amount of venous return can lead to ventricular suction or overload. Physiological control may compensate such situations by an automatic adaptation of the pump flow to the volume status of the left ventricle. We evaluated two physiological control algorithms in an acute study with eight healthy pigs. Both controllers imitate the Frank-Starling law of the heart and are based on a measurement of the left ventricular volume or pressure, respectively. After implantation of a modified Deltastream DP2 blood pump as an LVAD, we tested the responses of the physiological controllers to hemodynamic changes and compared them with the response of the constant speed mode. Both physiological controllers adapted the pump speed such that the flow was more sensitive to preload and less sensitive to afterload, as compared to the constant speed mode. As a result, the risk for suction was strongly reduced. Five suction events were observed in the constant speed mode, one with the volume-based controller, and none with the pressure-based controller. The results suggest that both physiological controllers have the potential to reduce the number of adverse events when used in the clinical setting.Turbodynamic left ventricular assist devices (LVADs) provide a continuous flow depending on the speed at which the pump is set, and do not adapt to the changing requirements of the patient. The limited adaptation of the pump flow (PF) to the amount of venous return can lead to ventricular suction or overload. Physiologic control may compensate such situations by an automatic adaptation of the PF to the volume status of the left ventricle. We evaluated two physiologic control algorithms in an acute study with eight healthy pigs. Both controllers imitate the Frank–Starling law of the heart and are based on a measurement of the left ventricular volume (LVV) or pressure (LVP), respectively. After implantation of a modified Deltastream DP2 blood pump as an LVAD, we tested the responses of the physiologic controllers to hemodynamic changes and compared them with the response of the constant speed (CS) mode. Both physiologic controllers adapted the pump speed (PS) such that the flow was more sensitive to preload and less sensitive to afterload, as compared with the CS mode. As a result, the risk for suction was strongly reduced. Five suction events were observed in the CS mode, one with the volume-based controller and none with the pressure-based controller. The results suggest that both physiologic controllers have the potential to reduce the number of adverse events when used in the clinical setting.


Annals of Biomedical Engineering | 2017

Left Ventricular Assist Devices: Challenges Toward Sustaining Long-Term Patient Care

Marianne Schmid Daners; Friedrich Kaufmann; Raffael Amacher; Gregor Ochsner; Markus J. Wilhelm; Aldo Ferrari; Edoardo Mazza; Dimos Poulikakos; Mirko Meboldt; Volkmar Falk

Over the last few decades, the left ventricular assist device (LVAD) technology has been tremendously improved transitioning from large and noisy paracorporeal volume displacement pumps to small implantable turbodynamic devices with only a single transcutaneous element, the driveline. Nevertheless, there remains a great demand for further improvements to meet the challenge of having a robust and safe device for long-term therapy. Here, we review the state of the art and highlight four key areas of needed improvement targeting long-term, sustainable LVAD function: (1) LVADs available today still have a high risk of thromboembolic and bleeding events that could be addressed by the rational fabrication of novel surface structures and endothelialization approaches aiming at improving the device hemocompatibility. (2) Novel, fluid dynamically optimized pump designs will further reduce blood damage. (3) Infection due to the paracorporeal driveline can be avoided with a transcutaneous energy transmission system that additionally allows for increased freedom of movement. (4) Finally, the lack of pump flow adaptation needs to be encountered with physiological control systems, working collaboratively with biocompatible sensor devices, targeting the adaptation of the LVAD flow to the perfusion requirements of the patient. The interdisciplinary Zurich Heart project investigates these technology gaps paving the way toward LVADs for long-term, sustainable therapy.


Artificial Organs | 2018

Control of the fluid viscosity in a mock circulation

Stefan Boës; Gregor Ochsner; Raffael Amacher; Anastasios Petrou; Mirko Meboldt; Marianne Schmid Daners

A mock circulation allows the in vitro investigation, development, and testing of ventricular assist devices. An aqueous-glycerol solution is commonly used to mimic the viscosity of blood. Due to evaporation and temperature changes, the viscosity of the solution drifts from its initial value and therefore, deviates substantially from the targeted viscosity of blood. Additionally, the solution needs to be exchanged to account for changing viscosities when mimicking different hematocrits. This article presents a method to control the viscosity in a mock circulation. This method makes use of the relationship between temperature and viscosity of aqueous-glycerol solutions and employs the automatic control of the viscosity of the fluid. To that end, an existing mock circulation was extended with an industrial viscometer, temperature probes, and a heating nozzle band. The results obtained with different fluid viscosities show that a viscosity controller is vital for repeatable experimental conditions on mock circulations. With a mixture ratio of 49 mass percent of aqueous-glycerol solution, the controller can mimic a viscosity range corresponding to a hematocrit between 29 and 42% in a temperature range of 30-42°C. The control response has no overshoot and the settling time is 8.4 min for a viscosity step of 0.3 cP, equivalent to a hematocrit step of 3.6%. Two rotary blood pumps that are in clinical use are tested at different viscosities. At a flow rate of 5 L/min, both show a deviation of roughly 15 and 10% in motor current for high rotor speeds. The influence of different viscosities on the measured head pressure is negligible. Viscosity control for a mock circulation thus plays an important role for assessing the required motor current of ventricular assist devices. For the investigation of the power consumption of rotary blood pumps and the development of flow estimators where the motor current is a model input, an integrated viscosity controller is a valuable contribution to an accurate testing environment.