Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Gunnar Tepe is active.

Publication


Featured researches published by Gunnar Tepe.


Circulation | 2007

Nitinol Stent Implantation Versus Percutaneous Transluminal Angioplasty in Superficial Femoral Artery Lesions up to 10 cm in Length: The Femoral Artery Stenting Trial (FAST)

Hans Krankenberg; Michael Schlüter; Hermann J. Steinkamp; Karlheinz Bürgelin; Dierk Scheinert; Karl-Ludwig Schulte; Erich Minar; Patrick Peeters; Marc Bosiers; Gunnar Tepe; Bernhard Reimers; Felix Mahler; Thilo Tübler; Thomas Zeller

Background— Endoluminal treatment of superficial femoral artery lesions is a matter of controversy. The present study was designed to investigate the impact of nitinol stenting of superficial femoral artery lesions with a maximum length of 10 cm on restenosis and clinical outcomes at 1 year. Methods and Results— Two hundred forty-four patients (168 men; 66±9 years) with a single superficial femoral artery lesion and chronic limb ischemia were randomized to implantation of a single Bard Luminexx 3 stent (123 patients) or stand-alone percutaneous transluminal angioplasty (PTA) (121 patients). Mean lesion length was 45 mm. Technical success (residual stenosis <50% for PTA, <30% for stenting) was achieved in 96 patients assigned to PTA (79%) and 117 patients assigned to stenting (95%); 13 PTA group patients (11%) “crossed over” to stenting. At 1 year, the primary end point of ultrasound-assessed binary restenosis was reached in 39 of 101 PTA group patients (38.6%) and 32 of 101 stent group patients (31.7%; absolute treatment difference, −6.9%; 95% CI, −19.7% to 6.2%; P=0.377). Target lesion revascularization rates at 1 year were 18.3% and 14.9%, respectively (absolute treatment difference, −3.3%; 95% CI, −13.0% to 6.4%; P=0.595). No statistically significant difference between treatment groups was observed at 12 months in the improvement by at least 1 Rutherford category of peripheral arterial disease. Conclusions— In the present study of patients with short superficial femoral artery lesions, the hypothesized absolute difference of 20% in binary restenosis at 1 year between the implantation of a single Luminexx nitinol stent and stand-alone PTA could not be demonstrated. A smaller difference requiring a larger trial might have been missed.


Circulation | 2008

Inhibition of Restenosis in Femoropopliteal Arteries Paclitaxel-Coated Versus Uncoated Balloon: Femoral Paclitaxel Randomized Pilot Trial

Michael Werk; Soenke Langner; Bianka Reinkensmeier; Hans-Frank Boettcher; Gunnar Tepe; Ulrich Dietz; Norbert Hosten; Bernd Hamm; Ulrich Speck; Jens Ricke

Background— The success of percutaneous intervention in peripheral arterial disease is limited by restenosis. The aim of the present pilot study was to evaluate a novel method of local drug delivery. Methods and Results— This randomized multicenter study with blinded reading enrolled 87 patients in Rutherford class 1 to 4 with occlusion or hemodynamically relevant stenosis, restenosis, or in-stent restenosis of femoropopliteal arteries. Treatment was performed by either conventional uncoated or paclitaxel-coated balloon catheters. The primary end point was late lumen loss at 6 months. Secondary end points included restenosis rate, ankle brachial index, Rutherford class, target lesion revascularization, and tolerance up to >18 months. Before intervention, there were no significant differences in lesion characteristics such as reference diameter (5.3±1.1 versus 5.2±1.0 mm), degree of stenosis (84±11% versus 84±16%), proportion of restenotic lesions (36% versus 33%), and mean lesion length (5.7 cm [0.8 to 22.6 cm] versus 6.1 cm [0.9 to 19.3 cm]) between treatment groups. The 6-month follow-up angiography performed in 31 of 45 and 34 of 42 patients showed less late lumen loss in the coated balloon group (0.5±1.1 versus 1.0±1.1 mm; P=0.031). The number of target lesion revascularizations was lower in the paclitaxel-coated balloon group than in control subjects (3 of 45 versus 14 of 42 patients; P=0.002). Improvement in Rutherford class was greater in the coated balloon group (P=0.045), whereas the improvement in ankle brachial index was not different. The difference in target lesion revascularizations between treatment groups was maintained up to >18 months. No adverse events were assessed as related to balloon coating. Conclusions— In this pilot trial, paclitaxel balloon coating caused no obvious adverse events and reduced restenosis in patients undergoing angioplasty of femoropopliteal arteries.


Journal of Endovascular Therapy | 2006

Drug-Eluting and Bare Nitinol Stents for the Treatment of Atherosclerotic Lesions in the Superficial Femoral Artery: Long-Term Results from the SIROCCO Trial

Stephan H. Duda; Marc Bosiers; Johannes Lammer; Dierk Scheinert; Thomas Zeller; Vincent L. Oliva; Alexander V. Tielbeek; John Lennon Anderson; Benjamin Wiesinger; Gunnar Tepe; Alexandra J. Lansky; Michael R. Jaff; Catharina Mudde; Hans Tielemans; Jean-Paul Beregi

Purpose: To review clinical outcomes of patients with chronic limb ischemia and TASC type C lesions treated with sirolimus-eluting versus bare SMART nitinol self-expanding stents. Methods: Data were obtained from a randomized, multicenter, double-blinded study conducted in 2 phases. All 93 patients had chronic limb ischemia and superficial femoral artery (SFA) occlusions or stenoses (average lesion length 8.3 cm). In total, 47 patients (31 men; mean age 66.3±9.1 years, range 50–84) received the sirolimus-eluting SMART stent and 46 patients (36 men; mean age 65.9 ± 10.8 years, range 38–83) received a bare SMART nitinol stent. Both groups were followed for a mean 24 months. Results: Both the sirolimus-eluting and the bare SMART stents were effective in revascularizing the diseased SFA and in sustaining freedom from restenosis. For both types of stents, improvements in ankle-brachial indices (ABI) and symptoms of claudication were maintained over 24 months (median 24-month ABI 0.96 for the sirolimus group versus 0.87 for the bare stent group, p>0.05). At 24 months, the restenosis rate in the sirolimus group was 22.9% versus 21.1% in the bare stent group (p>0.05). The cumulative in-stent restenosis rates according to duplex ultrasound were 4.7%, 9.0%, 15.6%, and 21.9%, respectively, at 6, 9, 18, and 24 months; the rates did not differ significantly between the treatment groups. The TLR rate for the sirolimus group was 6% and for the bare stent group 13%; the TVR rates were somewhat higher: 13% and 22%, respectively. Mortality rates did not differ significantly between the groups. Conclusion: These data demonstrate that the sirolimus-eluting and the bare SMART stent are effective, safe, and free from restenosis in a majority of patients for up to 24 months. Because the restenosis rate in the bare stent group is unexpectedly low, no significant difference could be found between the sirolimus-eluting and the bare SMART stents.


Journal of Vascular and Interventional Radiology | 2005

Sirolimus-Eluting versus Bare Nitinol Stent for Obstructive Superficial Femoral Artery Disease: The SIROCCO II Trial

Stephan H. Duda; Marc Bosiers; Johannes Lammer; Dierk Scheinert; Thomas Zeller; Alexander V. Tielbeek; John Lennon Anderson; Benjamin Wiesinger; Gunnar Tepe; Alexandra J. Lansky; Catharina Mudde; Hans Tielemans; Jean Paul Beregi

PURPOSE To investigate further the safety and efficacy of the sirolimus-eluting S. M.A.R.T. Nitinol Self-expanding Stent by comparison with a bare stent in superficial femoral artery (SFA) obstructions. MATERIALS AND METHODS This randomized, double-blind study involved 57 patients (29 in the sirolimus-eluting stent group and 28 in the bare stent group) with chronic limb ischemia and SFA occlusions (66.7%) or stenoses (average lesion length, 81.5 mm +/- 41.2). Stent implantation followed standard interventional techniques and a maximum of two stents could be implanted. The primary endpoint was the in-stent mean lumen diameter at 6 months as determined by quantitative angiography. RESULTS Both stent types were effective in revascularizing the diseased SFA and allowing sustained patency for at least 6 months. There was no statistically significant difference between treatment groups in the in-stent mean lumen diameter at 6 months (4.94 mm +/- 0.69 and 4.76 mm +/- 0.54 mm for sirolimus-eluting and bare stent groups, respectively; P = .31). Although the diameter of the target lesion tended to be larger and percent stenosis tended to be lower with the sirolimus-eluting stent, there were no statistically significant differences between treatments in terms of any of the variables. The mean late loss values were 0.38 mm +/- 0.64 and 0.68 mm +/- 0.97 for the sirolimus-eluting stent group and the bare stent group, respectively (P = .20). The binary restenosis rates, with a cutoff of 50% at 6 months, were zero in the sirolimus-eluting stent group and 7.7% in the bare stent group (P = .49). Clinical outcomes matched angiographic outcomes with improvements in ankle-brachial index and symptoms of claudication. There was no significant difference between treatments in terms of adverse events. CONCLUSION Although there is a trend for greater efficacy in the sirolimus-eluting stent group, there were no statistically significant differences in any of the variables.


Circulation | 2015

Drug-coated balloon versus standard percutaneous transluminal angioplasty for the treatment of superficial femoral and popliteal peripheral artery disease: 12-month results from the IN.PACT SFA randomized trial.

Gunnar Tepe; John R. Laird; Peter Schneider; Marianne Brodmann; Prakash Krishnan; Antonio Micari; Christopher Metzger; Dierk Scheinert; Thomas Zeller; David J. Cohen; David Snead; Beaux Alexander; Mario Landini; Michael R. Jaff

Background— Drug-coated balloons (DCBs) have shown promise in improving the outcomes for patients with peripheral artery disease. We compared a paclitaxel-coated balloon with percutaneous transluminal angioplasty (PTA) for the treatment of symptomatic superficial femoral and popliteal artery disease. Methods and Results— The IN.PACT SFA Trial is a prospective, multicenter, single-blinded, randomized trial in which 331 patients with intermittent claudication or ischemic rest pain attributable to superficial femoral and popliteal peripheral artery disease were randomly assigned in a 2:1 ratio to treatment with DCB or PTA. The primary efficacy end point was primary patency, defined as freedom from restenosis or clinically driven target lesion revascularization at 12 months. Baseline characteristics were similar between the 2 groups. Mean lesion length and the percentage of total occlusions for the DCB and PTA arms were 8.94±4.89 and 8.81±5.12 cm (P=0.82) and 25.8% and 19.5% (P=0.22), respectively. DCB resulted in higher primary patency versus PTA (82.2% versus 52.4%; P<0.001). The rate of clinically driven target lesion revascularization was 2.4% in the DCB arm in comparison with 20.6% in the PTA arm (P<0.001). There was a low rate of vessel thrombosis in both arms (1.4% after DCB and 3.7% after PTA [P=0.10]). There were no device- or procedure-related deaths and no major amputations. Conclusions— In this prospective, multicenter, randomized trial, DCB was superior to PTA and had a favorable safety profile for the treatment of patients with symptomatic femoropopliteal peripheral artery disease. Clinical Trial Registration— URL: http://www.clinicaltrials.gov. Unique Identifiers: NCT01175850 and NCT01566461.


Jacc-cardiovascular Interventions | 2014

The LEVANT I (Lutonix Paclitaxel-Coated Balloon for the Prevention of Femoropopliteal Restenosis) Trial for Femoropopliteal Revascularization : First-in-Human Randomized Trial of Low-Dose Drug-Coated Balloon Versus Uncoated Balloon Angioplasty

Dierk Scheinert; Stephan H. Duda; Thomas Zeller; Hans Krankenberg; Jens Ricke; Marc Bosiers; Gunnar Tepe; Scott Naisbitt; Kenneth Rosenfield

OBJECTIVES This study sought to evaluate the safety and efficacy of the Lutonix drug-coated balloon (DCB) coated with 2 μg/mm(2)paclitaxel and a polysorbate/sorbitol carrier for treatment of femoropopliteal lesions. BACKGROUND Percutaneous treatment of peripheral vascular disease is associated with a high recurrence. Paclitaxel-coated balloons at 3 μg/mm(2) formulated differently have shown promising results with reduced restenosis. Methods Subjects at 9 centers with Rutherford class 2 to 5 femoropopliteal lesions were randomized between June 2009 and December 2009 to treatment with Lutonix DCB (n = 49) versus uncoated balloons (control group [n = 52]), stratified by whether balloon-only treatment (n = 75) or stenting (n = 26) was intended. The primary endpoint was angiographic late lumen loss at 6 months. Secondary outcomes included adjudicated major adverse events (death, amputation, target lesion thrombosis, reintervention), functional outcomes, and pharmacokinetics. RESULTS Demographic, peripheral vascular disease, and lesion characteristics were matched, with mean lesion length of 8.1 3.8 cm and 42% total occlusions. At 6 months, late lumen loss was 58% lower for the Lutonix DCB group (0.46 1.13 mm) than for the control group (1.09 1.07 mm; p = 0.016). Composite 24-month major adverse events were 39% for the DCB group, including 15 target lesion revascularizations, 1 amputation, and 4 deaths versus 46% for uncoated balloon group, with 20 target lesion revascularizations, 1 thrombosis, and 5 deaths. Pharmacokinetics showed biexponential decay with peak concentration (Cmax) of 59 ng/ml and total observed exposure (AUC(all)) of 73 ng h/ml. For successful DCB deployment excluding 8 malfunctions, 6-month late lumen loss was 0.39 mm and the 24-month target lesion revascularization rate was 24%. CONCLUSIONS Treatment of femoropopliteal lesions with the low-dose Lutonix DCB reduced late lumen loss with safety comparable to that of control angioplasty. (LEVANT I, The Lutonix Paclitaxel-Coated Balloon for the Prevention of Femoropopliteal Restenosis; NCT00930813)


Journal of Vascular and Interventional Radiology | 2000

Physical Properties of Endovascular Stents: An Experimental Comparison

Stephan H. Duda; Jakub Wiskirchen; Gunnar Tepe; Michael Bitzer; Theodor W. Kaulich; Dieter Stoeckel; Claus D. Claussen

PURPOSE Different endovascular stent types (AVE Bridge, AVE Bridge X, Memotherm, Palmaz Large, Palmaz Medium, Palmaz-Schatz Long-Medium, Perflex, S.MA.R.T., Symphony, and Wall-stent) of 4 cm length and 8 mm diameter were subjected to standardized physical tests. MATERIALS AND METHODS The metal mass of each stent was assessed by weighing. The balloon-expandable stents were pneumatically tested for hoop strength. In self-expanding stents, radial resistive force and chronic outward force were determined with use of a loop test. Stent delivery system pushability was assessed in a crossover model. Stent radiopacity was analyzed quantitatively. RESULTS The hoop strength of the balloon-expandable stents ranged from 15.8 N/cm (Perflex) to 28.9 N/cm (AVE Bridge X). The stent weight increased with greater hoop strength (Perflex, 0.046 g/cm vs. AVE Bridge X, 0.061 g(cm). The self-expanding stents had a radial resistive force between 0.39 N/cm (Wallstent) and 1.7 N/cm (Smart). The flexible balloon-expandable stents showed pushability values between 0.13/N (AVE Bridge) and 0.20/N (Perflex). The self-expanding stents had flexibilities between 0.13/N (Memotherm) and 0.24/N (Symphony). Radiopacity assessed with use of a phantom simulating the iliac region ranged from 92 (Palmaz Large) to 115 (AVE Bridge) on a 256-point gray scale (0 = black, 256 = white). CONCLUSIONS There is no stent with ideal physical properties. However, depending on the characteristics of the arterial lesion to be treated, the most appropriate stent can be chosen.


Journal of the American College of Cardiology | 2015

Durability of Treatment Effect Using a Drug-Coated Balloon for Femoropopliteal Lesions: 24-Month Results of IN.PACT SFA.

John R. Laird; Peter Schneider; Gunnar Tepe; Marianne Brodmann; Thomas Zeller; Christopher Metzger; Prakash Krishnan; Dierk Scheinert; Antonio Micari; David J. Cohen; Hong Wang; Melissa S. Hasenbank; Michael R. Jaff

BACKGROUND Evidence from large, randomized, controlled peripheral artery disease trials reporting long-term outcomes using drug-coated balloons (DCBs) is limited. Previously, the DCB showed favorable 1-year outcomes compared with conventional percutaneous transluminal angioplasty (PTA), yet durability of the treatment effect with DCBs remains unknown. OBJECTIVES This study sought to investigate the longer-term outcomes of a paclitaxel-eluting DCB compared to PTA for femoropopliteal lesions. METHODS We enrolled 331 patients with symptomatic (Rutherford 2 to 4) femoropopliteal lesions up to 18 cm in length. Patients were randomly assigned in a 2:1 ratio to treatment with DCB or PTA. The 24-month assessments included primary patency, freedom from clinically driven target lesion revascularization (CD-TLR), major adverse events, and quality of life and functional outcomes as assessed by the EuroQOL-5D quality-of-life questionnaire, walking impairment questionnaire, and 6-min walk test. RESULTS At 24 months, patients treated with DCB showed significantly higher primary patency when compared with PTA (78.9% vs. 50.1%; p < 0.001). The rates of CD-TLR were 9.1% and 28.3% (p < 0.001) for the DCB and PTA groups, respectively. The overall mortality rate in the DCB group was 8.1% versus 0.9% in the PTA group (p = 0.008). There were no device- or procedure-related deaths and no major amputations in either group through 24-month follow-up. The rate of vessel thrombosis was low (1.5% DCB vs. 3.8% PTA; p = 0.243), with no new events reported between 1 and 2 years. Both groups showed similar functional improvement at 2 years, although DCB patients achieved this level of function with 58% fewer reinterventions. CONCLUSIONS The 24-month outcomes from the trial demonstrate a durable and superior treatment effect of DCB versus PTA with significantly higher primary patency, lower CD-TLR, and similar functional status improvement with fewer repeat interventions. (Randomized Trial of IN.PACT Admiral Drug Eluting Balloon vs Standard PTA for the Treatment of SFA and Proximal Popliteal Arterial Disease [INPACT SFA I]; NCT01175850; and IN.PACT Admiral Drug-Coated Balloon vs. Standard Balloon Angioplasty for the Treatment of Superficial Femoral Artery [SFA] and Proximal Popliteal Artery [PPA] [INPACT SFA II]; NCT01566461).


Journal of Endovascular Therapy | 2011

Nitinol stents with polymer-free paclitaxel coating for lesions in the superficial femoral and popliteal arteries above the knee: twelve-month safety and effectiveness results from the Zilver PTX single-arm clinical study.

Michael D. Dake; Dierk Scheinert; Gunnar Tepe; Jörg Tessarek; Fabrizio Fanelli; Marc Bosiers; Christof Ruhlmann; Zaza Kavteladze; Aaron E. Lottes; Anthony O. Ragheb; Thomas Zeller

Purpose To report a prospective, single-arm, multicenter clinical study evaluating the Zilver PTX drug-eluting stent for treating the above-the-knee femoropopliteal segment (NCT01094678; http://www.clinicaltrials.gov ). Methods The Zilver PTX drug-eluting stent is a self-expanding nitinol stent with a polymer-free paclitaxel coating. Patients with symptomatic (Rutherford category 2–6) de novo or restenotic lesions (including in-stent stenosis) of the above-the-knee femoropopliteal segment were eligible for enrollment. Between April 2006 and June 2008, 787 patients (578 men; mean age 66.6±9.5 years) were enrolled at 30 international sites. Results Nine hundred lesions (24.3% restenotic lesions of which 59.4% were in-stent stenoses) were treated with 1722 Zilver PTX stents; the mean lesion length was 99.5±82.1 mm. The 12-month Kaplan-Meier estimates included an 89.0% event-free survival rate, an 86.2% primary patency rate, and a 90.5% rate of freedom from target lesion revascularization. There were no paclitaxel-related adverse events reported. The 12-month stent fracture rate was 1.5%. The ankle-brachial index, Rutherford score, and walking distance/speed scores significantly improved (p<0.001) from baseline to 12 months. Conclusions These results indicate that the Zilver PTX drug-eluting stent is safe for treatment of patients with de novo and restenotic lesions of the above-the-knee femoropopliteal segment. At 1 year, the overall anatomical and clinical effectiveness results suggest that this stent is a promising endovascular therapy.


European Heart Journal | 2011

Sirolimus-eluting stents vs. bare-metal stents for treatment of focal lesions in infrapopliteal arteries: a double-blind, multi-centre, randomized clinical trial

Aljoscha Rastan; Gunnar Tepe; Hans Krankenberg; Rainer Zahorsky; Ullrich Beschorner; Elias Noory; Sebastian Sixt; Thomas Schwarz; Klaus Brechtel; Catherine Böhme; Franz-Josef Neumann; Thomas Zeller

AIMS Preliminary reports indicate that sirolimus-eluting stents reduce the risk of restenosis after percutaneous infrapopliteal artery revascularization. We conducted a prospective, randomized, multi-centre, double-blind trial comparing a polymer-free sirolimus-eluting stent with a placebo-coated bare-metal stent in patients with either intermittent claudication or critical limb ischaemia who had a de-novo lesion in an infrapopliteal artery. METHODS AND RESULTS 161 patients were included in this trial. The mean target lesion length was 31 ± 9 mm. The main study endpoint was the 1-year primary patency rate, defined as freedom from in-stent-restenosis (luminal narrowing of ≥50%) detected with duplex ultrasound if not appropriate with angiography. Secondary endpoints included the 6-month primary patency rate, secondary patency rate, and changes in Rutherford-Becker classification after 1 year. Twenty-five (15.5%) patients died during the follow-up period. One hundred and twenty-five patients reached the 1-year examinations. The 1-year primary patency rate was significantly higher in the sirolimus-eluting stent group (80.6%) than in the bare-metal stent group (55.6%, P= 0.004), and the 1-year secondary patency rates were 91.9 and 71.4% (P= 0.005), respectively. The median (interquartile range) change in Rutherford-Becker classification after 1 year was -2 (-3 to -1) in the sirolimus-eluting stent group and -1 (-2 to 0) in the bare-metal stent group, respectively (P= 0.004). CONCLUSION Mid-term patency rates of focal infrapopliteal lesions are substantially improved with sirolimus-eluting stent compared with bare-metal stent. Corresponding to the technical results, the changes in Rutherford-Becker classification reveal a significant advantage for the sirolimus-eluting stent.

Collaboration


Dive into the Gunnar Tepe's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Michael R. Jaff

Newton Wellesley Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge