Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Gustavo H. Olivera is active.

Publication


Featured researches published by Gustavo H. Olivera.


International Journal of Radiation Oncology Biology Physics | 2003

Image guidance for precise conformal radiotherapy

T Mackie; Jeff Kapatoes; K Ruchala; Weiguo Lu; Chuan Wu; Gustavo H. Olivera; Lisa J. Forrest; Wolfgang A. Tomé; Jim Welsh; R Jeraj; Paul M. Harari; Paul J. Reckwerdt; Bhudatt R. Paliwal; Mark A. Ritter; Harry Keller; Jack F. Fowler; Minesh P. Mehta

PURPOSE To review the state of the art in image-guided precision conformal radiotherapy and to describe how helical tomotherapy compares with the image-guided practices being developed for conventional radiotherapy. MATERIALS AND METHODS Image guidance is beginning to be the fundamental basis for radiotherapy planning, delivery, and verification. Radiotherapy planning requires more precision in the extension and localization of disease. When greater precision is not possible, conformal avoidance methodology may be indicated whereby the margin of disease extension is generous, except where sensitive normal tissues exist. Radiotherapy delivery requires better precision in the definition of treatment volume, on a daily basis if necessary. Helical tomotherapy has been designed to use CT imaging technology to plan, deliver, and verify that the delivery has been carried out as planned. The image-guided processes of helical tomotherapy that enable this goal are described. RESULTS Examples of the results of helical tomotherapy processes for image-guided intensity-modulated radiotherapy are presented. These processes include megavoltage CT acquisition, automated segmentation of CT images, dose reconstruction using the CT image set, deformable registration of CT images, and reoptimization. CONCLUSIONS Image-guided precision conformal radiotherapy can be used as a tool to treat the tumor yet spare critical structures. Helical tomotherapy has been designed from the ground up as an integrated image-guided intensity-modulated radiotherapy system and allows new verification processes based on megavoltage CT images to be implemented.


Medical Physics | 2007

The management of imaging dose during image-guided radiotherapy: Report of the AAPM Task Group 75

Martin J. Murphy; James M. Balter; Stephen Balter; J BenComo; Indra J. Das; S Jiang; Chang-Ming Ma; Gustavo H. Olivera; Raymond F. Rodebaugh; Kenneth J. Ruchala; Hiroki Shirato; Fang-Fang Yin

Radiographic image guidance has emerged as the new paradigm for patient positioning, target localization, and external beam alignment in radiotherapy. Although widely varied in modality and method, all radiographic guidance techniques have one thing in common--they can give a significant radiation dose to the patient. As with all medical uses of ionizing radiation, the general view is that this exposure should be carefully managed. The philosophy for dose management adopted by the diagnostic imaging community is summarized by the acronym ALARA, i.e., as low as reasonably achievable. But unlike the general situation with diagnostic imaging and image-guided surgery, image-guided radiotherapy (IGRT) adds the imaging dose to an already high level of therapeutic radiation. There is furthermore an interplay between increased imaging and improved therapeutic dose conformity that suggests the possibility of optimizing rather than simply minimizing the imaging dose. For this reason, the management of imaging dose during radiotherapy is a different problem than its management during routine diagnostic or image-guided surgical procedures. The imaging dose received as part of a radiotherapy treatment has long been regarded as negligible and thus has been quantified in a fairly loose manner. On the other hand, radiation oncologists examine the therapy dose distribution in minute detail. The introduction of more intensive imaging procedures for IGRT now obligates the clinician to evaluate therapeutic and imaging doses in a more balanced manner. This task group is charged with addressing the issue of radiation dose delivered via image guidance techniques during radiotherapy. The group has developed this charge into three objectives: (1) Compile an overview of image-guidance techniques and their associated radiation dose levels, to provide the clinician using a particular set of image guidance techniques with enough data to estimate the total diagnostic dose for a specific treatment scenario, (2) identify ways to reduce the total imaging dose without sacrificing essential imaging information, and (3) recommend optimization strategies to trade off imaging dose with improvements in therapeutic dose delivery. The end goal is to enable the design of image guidance regimens that are as effective and efficient as possible.


Physics in Medicine and Biology | 1999

Megavoltage CT on a tomotherapy system

K Ruchala; Gustavo H. Olivera; E A Schloesser; T Mackie

A megavoltage computed tomography (MVCT) system was developed on the University of Wisconsin tomotherapy benchtop. This system can operate either axially or helically, and collect transmission data without any bounds on delivered dose. Scan times as low as 12 s per slice are possible, and scans were run with linac output rates of 100 MU min(-1), although the system can be tuned to deliver arbitrarily low dose rates. Images were reconstructed with clinically reasonable doses ranging from 8 to 12 cGy. These images delineate contrasts below 2% and resolutions of 3.0 mm. Thus, the MVCT image quality of this system should be sufficient for verifying the patients position and anatomy prior to radiotherapy. Additionally, synthetic data were used to test the potential for improved MVCT contrast using maximum-likelihood (ML) reconstruction. Specifically, the maximum-likelihood expectation-maximization (ML-EM) algorithm and a transmission ML algorithm were compared with filtered backprojection (FBP). It was found that for expected clinical MVCT doses enough imaging photons are used such that little benefit is conferred by the improved noise model of ML algorithms. For significantly lower doses, some quantitative improvement is achieved through ML reconstruction. Nonetheless, the image quality at those lower doses is not satisfactory for radiotherapy verification.


Medical Physics | 2004

Radiation characteristics of helical tomotherapy

R Jeraj; T Mackie; John Balog; Gustavo H. Olivera; Dave Pearson; Jeff Kapatoes; K Ruchala; Paul J. Reckwerdt

Helical tomotherapy is a dedicated intensity modulated radiation therapy (IMRT) system with on-board imaging capability (MVCT) and therefore differs from conventional treatment units. Different design goals resulted in some distinctive radiation field characteristics. The most significant differences in the design are the lack of flattening filter, increased shielding of the collimators, treatment and imaging operation modes and narrow fan beam delivery. Radiation characteristics of the helical tomotherapy system, sensitivity studies of various incident electron beam parameters and radiation safety analyses are presented here. It was determined that the photon beam energy spectrum of helical tomotherapy is similar to that of more conventional radiation treatment units. The two operational modes of the system result in different nominal energies of the incident electron beam with approximately 6 MeV and 3.5 MeV in the treatment and imaging modes, respectively. The off-axis mean energy dependence is much lower than in conventional radiotherapy units with less than 5% variation across the field, which is the consequence of the absent flattening filter. For the same reason the transverse profile exhibits the characteristic conical shape resulting in a 2-fold increase of the beam intensity in the center. The radiation leakage outside the field was found to be negligible at less than 0.05% because of the increased shielding of the collimators. At this level the in-field scattering is a dominant source of the radiation outside the field and thus a narrow field treatment does not result in the increased leakage. The sensitivity studies showed increased sensitivity on the incident electron position because of the narrow fan beam delivery and high sensitivity on the incident electron energy, as common to other treatment systems. All in all, it was determined that helical tomotherapy is a system with some unique radiation characteristics, which have been to a large extent optimized for intensity modulated delivery.


Physics in Medicine and Biology | 2005

The use of megavoltage CT (MVCT) images for dose recomputations.

Katja M. Langen; Sanford L. Meeks; D. Poole; Thomas H. Wagner; Twyla R. Willoughby; Patrick A. Kupelian; Kenneth J. Ruchala; Jason Haimerl; Gustavo H. Olivera

Megavoltage CT (MVCT) images of patients are acquired daily on a helical tomotherapy unit (TomoTherapy, Inc., Madison, WI). While these images are used primarily for patient alignment, they can also be used to recalculate the treatment plan for the patient anatomy of the day. The use of MVCT images for dose computations requires a reliable CT number to electron density calibration curve. In this work, we tested the stability of the MVCT numbers by determining the variation of this calibration with spatial arrangement of the phantom, time and MVCT acquisition parameters. The two calibration curves that represent the largest variations were applied to six clinical MVCT images for recalculations to test for dosimetric uncertainties. Among the six cases tested, the largest difference in any of the dosimetric endpoints was 3.1% but more typically the dosimetric endpoints varied by less than 2%. Using an average CT to electron density calibration and a thorax phantom, a series of end-to-end tests were run. Using a rigid phantom, recalculated dose volume histograms (DVHs) were compared with plan DVHs. Using a deformed phantom, recalculated point dose variations were compared with measurements. The MVCT field of view is limited and the image space outside this field of view can be filled in with information from the planning kVCT. This merging technique was tested for a rigid phantom. Finally, the influence of the MVCT slice thickness on the dose recalculation was investigated. The dosimetric differences observed in all phantom tests were within the range of dosimetric uncertainties observed due to variations in the calibration curve. The use of MVCT images allows the assessment of daily dose distributions with an accuracy that is similar to that of the initial kVCT dose calculation.


International Journal of Radiation Oncology Biology Physics | 2008

Assessment of parotid gland dose changes during head and neck cancer radiotherapy using daily megavoltage computed tomography and deformable image registration.

Choonik Lee; Katja M. Langen; Weiguo Lu; Jason Haimerl; Eric Schnarr; Kenneth J. Ruchala; Gustavo H. Olivera; Sanford L. Meeks; Patrick A. Kupelian; Thomas D. Shellenberger; Rafael R. Mañon

PURPOSE To analyze changes in parotid gland dose resulting from anatomic changes throughout a course of radiotherapy in a cohort of head-and-neck cancer patients. METHODS AND MATERIALS The study population consisted of 10 head-and-neck cancer patients treated definitively with intensity-modulated radiotherapy on a helical tomotherapy unit. A total of 330 daily megavoltage computed tomography images were retrospectively processed through a deformable image registration algorithm to be registered to the planning kilovoltage computed tomography images. The process resulted in deformed parotid contours and voxel mappings for both daily and accumulated dose-volume histogram calculations. The daily and cumulative dose deviations from the original treatment plan were analyzed. Correlations between dosimetric variations and anatomic changes were investigated. RESULTS The daily parotid mean dose of the 10 patients differed from the plan dose by an average of 15%. At the end of the treatment, 3 of the 10 patients were estimated to have received a greater than 10% higher mean parotid dose than in the original plan (range, 13-42%), whereas the remaining 7 patients received doses that differed by less than 10% (range, -6-8%). The dose difference was correlated with a migration of the parotids toward the high-dose region. CONCLUSIONS The use of deformable image registration techniques and daily megavoltage computed tomography imaging makes it possible to calculate daily and accumulated dose-volume histograms. Significant dose variations were observed as result of interfractional anatomic changes. These techniques enable the implementation of dose-adaptive radiotherapy.


Physics in Medicine and Biology | 2000

Iterative approaches to dose optimization in tomotherapy.

David M. Shepard; Gustavo H. Olivera; Paul J. Reckwerdt; T Mackie

This paper will present the results of an investigation into three iterative approaches to inverse treatment planning. These techniques have been examined in the hope of developing an optimization algorithm suitable for the large-scale problems that are encountered in tomotherapy. The three iterative techniques are referred to as the ratio method, iterative least-squares minimization and the maximum-likelihood estimator. Our results indicate that each of these techniques can serve as a useful tool in tomotherapy optimization. As compared with other mathematical programming techniques, the iterative approaches can reduce both memory demands and time requirements. In this paper, the results from small- and large-scale optimizations will be analysed. It will also be demonstrated that the flexibility of the iterative techniques can be greatly enhanced through the use of dose-volume histogram based penalty functions and/or through the use of weighting factors assigned to each region of the patient. Finally, results will be presented from an investigation into the stability of the iterative techniques.


Medical Physics | 2010

QA for helical tomotherapy: Report of the AAPM Task Group 148

Katja M. Langen; N Papanikolaou; John Balog; Richard J. Crilly; D Followill; S. Murty Goddu; Walter Grant; Gustavo H. Olivera; C Ramsey; Chengyu Shi

Helical tomotherapy is a relatively new modality with integrated treatment planning and delivery hardware for radiation therapy treatments. In view of the uniqueness of the hardware design of the helical tomotherapy unit and its implications in routine quality assurance, the Therapy Physics Committee of the American Association of Physicists in Medicine commissioned Task Group 148 to review this modality and make recommendations for quality assurance related methodologies. The specific objectives of this Task Group are: (a) To discuss quality assurance techniques, frequencies, and tolerances and (b) discuss dosimetric verification techniques applicable to this unit. This report summarizes the findings of the Task Group and aims to provide the practicing clinical medical physicist with the insight into the technology that is necessary to establish an independent and comprehensive quality assurance program for a helical tomotherapy unit. The emphasis of the report is to describe the rationale for the proposed QA program and to provide example tests that can be performed, drawing from the collective experience of the task group members and the published literature. It is expected that as technology continues to evolve, so will the test procedures that may be used in the future to perform comprehensive quality assurance for helical tomotherapy units.


Physics in Medicine and Biology | 2002

Re-optimization in adaptive radiotherapy

Chuan Wu; R Jeraj; Gustavo H. Olivera; T Mackie

In routine clinical practice, radiotherapy treatment planning is performed based on the patient CT images obtained during the patient setup procedure. However, the actual delivered dose to the patient might be different from the planned dose because of various reasons such as patient motion. Under such situations, it is desirable to modify the original treatment plan in order to partially remedy the dose delivery errors in the subsequent dose delivery process. Such modification can be implemented by modifying the original treatment plan using re-optimization. In this work, issues such as the re-optimization dose prescription, optimization constraints in re-optimization, re-optimization in multiple fractionation schemes and re-optimization procedure with generalized dose-based objective functions were investigated and corresponding mathematical schemes proposed. The derived results were applied to a clinical case study in which it was shown that the proposed re-optimization method is able to remedy the cold spots in tumour while delivering low dose to normal structures. Thus the potential effectiveness of the method was demonstrated.


Medical Physics | 2005

Feasibility study of helical tomotherapy for total body or total marrow irradiation.

S Hui; Jeff Kapatoes; Jack F. Fowler; Douglas Henderson; Gustavo H. Olivera; Rafael Manon; Bruce J. Gerbi; T Mackie; James S. Welsh

Total body radiation (TBI) has been used for many years as a preconditioning agent before bone marrow transplantation. Many side effects still plague its use. We investigated the planning and delivery of total body irradiation (TBI) and selective total marrow irradiation (TMI) and a reduced radiation dose to sensitive structures using image-guided helical tomotherapy. To assess the feasibility of using helical tomotherapy, (A) we studied variations in pitch, field width, and modulation factor on total body and total marrow helical tomotherapy treatments. We varied these parameters to provide a uniform dose along with a treatment times similar to conventional TBI (15-30min). (B) We also investigated limited (head, chest, and pelvis) megavoltage CT (MVCT) scanning for the dimensional pretreatment setup verification rather than total body MVCT scanning to shorten the overall treatment time per treatment fraction

Collaboration


Dive into the Gustavo H. Olivera's collaboration.

Top Co-Authors

Avatar

Weiguo Lu

University of Texas Southwestern Medical Center

View shared research outputs
Top Co-Authors

Avatar

Kenneth J. Ruchala

Wisconsin Alumni Research Foundation

View shared research outputs
Top Co-Authors

Avatar

T Mackie

University of Wisconsin-Madison

View shared research outputs
Top Co-Authors

Avatar

Paul J. Reckwerdt

University of Wisconsin-Madison

View shared research outputs
Top Co-Authors

Avatar

Quan Chen

University of Virginia

View shared research outputs
Top Co-Authors

Avatar

Jeffrey M. Kapatoes

Wisconsin Alumni Research Foundation

View shared research outputs
Top Co-Authors

Avatar

Thomas R. Mackie

Wisconsin Alumni Research Foundation

View shared research outputs
Top Co-Authors

Avatar

Katja M. Langen

University of Texas MD Anderson Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Sanford L. Meeks

University of Texas MD Anderson Cancer Center

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge