Journal of Cosmology and Astroparticle Physics | 2007

An improved limit on the axion–photon coupling from the CAST experiment

S. Andriamonje; S. Aune; D. Autiero; K. Barth; A. Belov; B. Beltrán; H. Bräuninger; J. M. Carmona; S. Cebrián; J. I. Collar; T. Dafni; Martyn Davenport; L. Di Lella; C. Eleftheriadis; Jakob Englhauser; G. Fanourakis; E. Ferrer Ribas; H. Fischer; J. Franz; Peter Friedrich; T. Geralis; I. Giomataris; Sergei Gninenko; Haley Louise Gomez; M. Hasinoff; F.H. Heinsius; D. H. H. Hoffmann; I.G. Irastorza; J. Jacoby; K. Jakovčić

We have searched for solar axions or similar particles that couple to two photons by using the CERN Axion Solar Telescope (CAST) setup with improved conditions in all detectors. From the absence of excess X-rays when the magnet was pointing to the Sun, we set an upper limit on the axion-photon coupling of 8.8 x 10^{-11} GeV^{-1} at 95% CL for m_a<~ 0.02 eV. This result is the best experimental limit over a broad range of axion masses and for m_a<~ 0.02 eV also supersedes the previous limit derived from energy-loss arguments on globular-cluster stars.


Optical Science and Technology, SPIE's 48th Annual Meeting | 2004

Readout modes and automated operation of the Swift X-ray Telescope

J. E. Hill; David N. Burrows; John A. Nousek; Anthony F. Abbey; Richard M. Ambrosi; H. Bräuninger; Wolfgang Burkert; Sergio Campana; Chaitanya Cheruvu; G. Cusumano; Michael J. Freyberg; Gisela D. Hartner; R. Klar; C. Mangels; A. Moretti; Koji Mori; Dave C. Morris; A. Short; Gianpiero Tagliaferri; D. J. Watson; P. Wood; Alan A. Wells

The Swift X-ray Telescope (XRT) is designed to make astrometric, spectroscopic, and photometric observations of X-ray emission from Gamma-ray Bursts and their afterglows in the energy band 0.2-10 keV. In order to provide rapid-response, automated observations of these randomly occurring objects without ground intervention, the XRT must be able to observe objects covering some seven orders of magnitude in flux, extracting the maximum possible science from each one. This requires a variety of readout modes designed to optimise the information collected in response to shifting scientific priorities as the flux from the burst diminishes. The XRT will support four major readout modes: imaging, two timing modes and photon-counting, with several sub-modes. We describe in detail the readout modes of the XRT. We describe the flux ranges over which each mode will operate, the automated mode switching that will occur and the methods used for collection of bias information for this instrument. We also discuss the data products produced from each mode.


Astronomy and Astrophysics | 1997

The ROSAT all - sky survey bright source catalogue

W. Voges; B. Aschenbach; Th. Boller; H. Bräuninger; Ulrich G. Briel; Wolfgang Burkert; Konrad Dennerl; Jakob Englhauser; Ruth Ellen Gruber; F. Haberl; Gisela D. Hartner; G. Hasinger; M. Kürster; Elmar Pfeffermann; W. Pietsch; Peter Predehl; C. Rosso; J. H. M. M. Schmitt; J. Trumper; Uwe T. Zimmermann

In order to ensure the quality of the source catalogue derived from the SASS processing an automatic as well as a visual screening procedure was applied to 1378 survey fields. Most (94%) of the 18,811 sources were confirmed by this screening process. The rest is flagged for various reasons. Broad band images are available for a subset of the flagged sources. Details of the screening process can be found at www.rosat.mpe-garching.mpg.de/survey/rass-bsc/doc.html.


The Astrophysical Journal | 2000

First Light Measurements of Capella with the Low-Energy Transmission Grating Spectrometer aboard the Chandra X-Ray Observatory

Albert C. Brinkman; C. J. T. Gunsing; Jelle S. Kaastra; R. L. J. van der Meer; R. Mewe; Frederik Paerels; A. J. J. Raassen; J.J. Rooijen; H. Bräuninger; Wolfgang Burkert; Vadim Burwitz; Gisela D. Hartner; Peter Predehl; J.-U. Ness; J. H. M. M. Schmitt; Jeremy J. Drake; O. Johnson; Michael Juda; Vinay L. Kashyap; S. S. Murray; Deron O. Pease; Peter W. Ratzlaff; Bradford J. Wargelin

We present the first X-ray spectrum obtained by the Low-Energy Transmission Grating Spectrometer (LETGS) aboard the Chandra X-Ray Observatory. The spectrum is of Capella and covers a wavelength range of 5-175 Å (2.5-0.07 keV). The measured wavelength resolution, which is in good agreement with ground calibration, is Deltalambda approximately 0.06 Å (FWHM). Although in-flight calibration of the LETGS is in progress, the high spectral resolution and unique wavelength coverage of the LETGS are well demonstrated by the results from Capella, a coronal source rich in spectral emission lines. While the primary purpose of this Letter is to demonstrate the spectroscopic potential of the LETGS, we also briefly present some preliminary astrophysical results. We discuss plasma parameters derived from line ratios in narrow spectral bands, such as the electron density diagnostics of the He-like triplets of carbon, nitrogen, and oxygen, as well as resonance scattering of the strong Fe xvii line at 15.014 Å.


Physical Review Letters | 2011

Search for Sub-eV Mass Solar Axions by the CERN Axion Solar Telescope with 3He Buffer Gas

M. Arik; S. Aune; K. Barth; A. Belov; Silvia Borghi; H. Bräuninger; G. Cantatore; J.M. Carmona; S. A. Cetin; J. I. Collar; T. Dafni; M. Davenport; C. Eleftheriadis; N. Elias; C. Ezer; G. Fanourakis; E. Ferrer-Ribas; Peter Friedrich; J. Galán; J. Garcia; A. Gardikiotis; E. N. Gazis; T. Geralis; I. Giomataris; Sergei Gninenko; Haley Louise Gomez; E. Gruber; T. Guthörl; Robert Hartmann; F. Haug

S. Aune, K. Barth, A. Belov, S. Borghi, ∗ H. Bräuninger, G. Cantatore, J. M. Carmona, S. A. Cetin, J. I. Collar, T. Dafni, M. Davenport, C. Eleftheriadis, N. Elias, C. Ezer, G. Fanourakis, E. Ferrer-Ribas, P. Friedrich, J. Galán, J. A. Garćıa, A. Gardikiotis, E. N. Gazis, T. Geralis, I. Giomataris, S. Gninenko, H. Gómez, E. Gruber, T. Guthörl, R. Hartmann, † F. Haug, M. D. Hasinoff, D. H. H. Hoffmann, F. J. Iguaz, ‡ I. G. Irastorza, J. Jacoby, K. Jakovčić, M. Karuza, K. Königsmann, R. Kotthaus, M. Krčmar, M. Kuster, 16, § B. Lakić, ¶ J. M. Laurent, A. Liolios, A. Ljubičić, V. Lozza, G. Lutz, † G. Luzón, J. Morales, ∗∗ T. Niinikoski, †† A. Nordt, 16, ‡‡ T. Papaevangelou, M. J. Pivovaroff, G. Raffelt, T. Rashba, H. Riege, A. Rodŕıguez, M. Rosu, J. Ruz, 2 I. Savvidis, P. S. Silva, S. K. Solanki, L. Stewart, A. Tomás, M. Tsagri, ‡‡ K. van Bibber, §§ T. Vafeiadis, 9, 12 J. Villar, J. K. Vogel, 20, ¶¶ S. C. Yildiz, and K. Zioutas 12


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 1993

The pn-CCD on-chip electronics.

E. Pinotti; H. Bräuninger; N. Findeis; H. Gorke; D. Hauff; Peter Holl; J. Kemmer; Peter Lechner; G. Lutz; W. Kink; Norbert Meidinger; G. Metzner; Peter Predehl; C. Reppin; L. Strüder; J. Trumper; Christoph von Zanthier; E. Kendziorra; R. Staubert; V. Radeka; P. Rehak; Giuseppe Bertuccio; E. Gatti; A. Longoni; Alberto Pullia; M. Sampietro

A new pn-CCD with an activa area of 3 × 1 cm2 was recently fabricated for ESAs X-ray Multi Mirror Mission (XMM). The front-end electronics has been integrated on the same chip as the detector, and its noise behaviour was investigated. X-rays from a 55Fe source have been used for the absolute calibration. The measured electronic Equivalent Noise Charge (ENC) of the on-chip amplifier was 8.8 e− at room temperature and 2.2 e− at the CCD operating temperature of 150 K. The improvements with respect to the last version with noise figures of 4.8 e− (at 150 K) are due to the reduction of the total input capacitance by a factor of 1.6, the improvement of the transistor transconductance by a factor of 2, and the reduction of 1ƒ noise because of the different p-well implant with a better thermal annealing.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 1990

The MPI/AIT X-ray imager (MAXI) — High speed pn CCDs for X-ray detection

L. Strüder; H. Bräuninger; M. Meier; Peter Predehl; C. Reppin; M. Sterzik; J. Trumper; P. Cattaneo; D. Hauff; G. Lutz; K. Schuster; A. S. Schwarz; E. Kenziorra; A. Staubert; E. Gatti; A. Longoni; M. Sampietro; V. Radeka; P. Rehak; S. Rescia; P.F. Manfredi; W. Buttler; Peter Holl; J. Kemmer; U. Prechtel; T. Ziemann

MAXI (MPI/AIT X-ray Imager) is part of a proposal submitted to the European Space Agency (ESA) as focal plane instrumentation of the X-ray Multi Mirror Mission (XMM). Within a collaboration of 13 European institutes we have proposed a fully depleted (sensitive) pn CCD of 280 μm thickness with a homogeneous sensitive area of 36 cm2 and a pixel size of 150×150 μm2 which is well matched with the telescopes angular resolution of 30 arcsec translating to a position resolution of approximately 1 mm in the focal plane. The X-ray sensitivity will be higher than 90% from 250 eV up to 10 keV, the readout time in the full frame mode of the complete focal plane will be 2 ms with a readout noise of better than 5 e− (rms). Prototypes of all individual components of the camera system have been fabricated and tested. The camera concept will be presented. The measured transfer properties of the CCD and the on-chip electronics will be treated. Taking into account the coupling of the on-chip amplifier to the following front-end electronics the expected performance will be derived.


Nature Physics | 2017

New CAST limit on the axion–photon interaction

V. Anastassopoulos; S. Aune; K. Barth; A. Belov; H. Bräuninger; G. Cantatore; J.M. Carmona; J. Castel; S. A. Cetin; Finn E. Christensen; J. I. Collar; T. Dafni; M. Davenport; T.A. Decker; A. Dermenev; K. Desch; C. Eleftheriadis; G. Fanourakis; E. Ferrer-Ribas; H. Fischer; J. Garcia; A. Gardikiotis; J. G. Garza; E. N. Gazis; T. Geralis; I. Giomataris; Sergei Gninenko; Charles J. Hailey; M. D. Hasinoff; D. H. H. Hoffmann

During 2003--2015, the CERN Axion Solar Telescope (CAST) has searched for


New Journal of Physics | 2007

The x-ray telescope of CAST

M. Kuster; H. Bräuninger; S. Cebrián; Martyn Davenport; C. Eleftheriadis; Jakob Englhauser; H. Fischer; J. Franz; Peter Friedrich; Robert Hartmann; F.H. Heinsius; D. H. H. Hoffmann; G Hoffmeister; J N Joux; D. Kang; K. Königsmann; R. Kotthaus; T. Papaevangelou; C. Lasseur; A. Lippitsch; G. Lutz; J. Morales; A. Rodríguez; L. Strüder; J. Vogel; Zioutas

a\to\gamma


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 1996

Performance of the pn-CCD X-ray detector system designed for the XMM satellite mission

Heike Soltau; Peter Holl; J. Kemmer; S. Krisch; Christoph von Zanthier; D. Hauff; R. Richter; H. Bräuninger; Robert Hartmann; Gisela D. Hartner; Norbert Krause; Norbert Meidinger; Elmar Pfeffermann; C. Reppin; G. Schwaab; L. Strüder; J. Trumper; E. Kendziorra; J. Krämer

conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. In its final phase of solar axion searches (2013--2015), CAST has returned to evacuated magnet pipes, which is optimal for small axion masses. The absence of a significant signal above background provides a world leading limit of

Collaboration


Dive into the H. Bräuninger's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Sergei Gninenko

Russian Academy of Sciences

View shared research outputs
Top Co-Authors

Avatar

C. Eleftheriadis

Aristotle University of Thessaloniki

View shared research outputs
Researchain Logo
Decentralizing Knowledge