Hans Meierer
University of Mainz
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Hans Meierer.
Mikrochimica Acta | 1989
Heinz Eschnauer; Ludwig Jakob; Hans Meierer; Rolf Neeb
At present, some 50 inorganic components in wine can be detected, of which 8 are mineral matter at concentrations down to 1 mg/l, about 25 are trace elements with concentrations of 0.001–0.1 mg/l, and about 20 are ultratrace elements at concentrations below 1 μg/1. It has been shown that ICP-OES, a typical multielement detection method, permits the fast and reliable simultaneous determination of whole range of these inorganic species in wine, and thus can help in solving practical problems in wine manufacture. For instance, the metal content of wine can be checked, and corrosion and contamination monitored. Ten trace elements (Al, Cd, Co, Cr, Cu, Fe, Mn, Pb, V, Zn) which may be toxic or to which wine is sensitive, can be determined, and their decrease through fermentation and fining established. Above all, ICP-OES seems suitable for defining the grape type and origin of wines in wine taxonomy (pattern analysis). Data obtained by ICP-OES can also help in assigning a vintage year.
Fresenius Journal of Analytical Chemistry | 1983
Hans Meierer; Rolf Neeb
SummaryA survey is given of the capillary gas-chromatographic behaviour of some dialkyldithiocarbamatochelates in comparison to the fluorinated diethyl-compounds. Only short columns give satisfying results for the non-fluorinated compounds. Linear calibration curves for cobalt and nickel are obtained in the range of 0.5 to 17.5 ng of metal. The use of dipropyl- and diisobutyl-compounds offers no advantages compared to the diethyl-compounds.ZusammenfassungEs wird ein Überblick über das capillargas-chromatographische Verhalten einiger Diethyldithiocarbamato-Chelate im Vergleich zu den fluorierten Diethyl-Verbindungen gegeben. Befriedigende Ergebnisse werden mit den nichtfluorierten Verbindungen nur auf kurzen Säulen erhalten. Die Eichkurven für Nickel und Cobalt sind im Bereich von 0,5 bis 17,5 ng Metall linear. Die Verwendung von Dipropyl- und Diisobutyldithiocarbamaten bringt keine Vorteile gegenüber den Diethyl-Verbindungen.
Fresenius Journal of Analytical Chemistry | 1982
Günther Hartmetz; Geoffrey R. Scollary; Hans Meierer; Axel Meyer; Rolf Neeb
Summary. A survey is given of the capillary gaschromatographic behaviour of some di(trifluoroethyl)dithiocarbamato-chelates. The influence of column material, column length, injection technique and choice of proper inner standards on the linearity of the calibration curves is discussed. The following elements were examined: TI, Hg, Cd, Cu, Co, Ni, Fe, Pb, In, Bi, Pd, Zn. Zusammenfassung. Es wird ein [)berblick fiber das Capillargas-chromatographische Verhalten einiger Di(trifluorethyl)dithiocarbamato-Chelate gegeben, wobei besonders der Einflul3 des S/iulenmaterials, der S/iulenlfinge, der Einspritztechnik und der Wahl eines geeigneten inneren Standards auf die Linearit/it der Eichkurven diskutiert wird. Folgende Elemente wurden untersucht: T1, Hg, Cd, Cu, Co, Ni, Fe, Pb, In, Bi, Pd, Zn.SummaryA survey is given of the capillary gaschromatographic behaviour of some di(trifluoroethyl)-dithiocarbamato-chelates. The influence of column material, column length, injection technique and choice of proper inner standards on the linearity of the calibration curves is discussed. The following elements were examined: Tl, Hg, Cd, Cu, Co, Ni, Fe, Pb, In, Bi, Pd, Zn.ZusammenfassungEs wird ein Überblick über das Capillargas-chromatographische Verhalten einiger Di(trifluorethyl)-dithiocarbamato-Chelate gegeben, wobei besonders der Einfluß des Säulenmaterials, der Säulenlänge, der Einspritztechnik und der Wahl eines geeigneten inneren Standards auf die Linearität der Eichkurven diskutiert wird. Folgende Elemente wurden untersucht: Tl, Hg, Cd, Cu, Co, Ni, Fe, Pb, In, Bi, Pd, Zn.
Fresenius Journal of Analytical Chemistry | 1982
J. Magner; Hans Meierer; Rolf Neeb
SummaryPreparation, gas-chromatographic and mass-spectroscopic behaviour of nickel-bis(dipentafluoropropyl)dithiocarbamate and nickel-bis[(diheptafluorobutyl)dithiocarbamate] are described. Ni-bis[(dipentafluoropropyl)dithiocarbamate] shows the smalles retention times both on packed and capillary columns.ZusammenfassungDarstellung sowie gas-chromatographisches und massenspektroskopisches Verhalten von Nickel-bis[di(pentafluorpropyl)dithiocarbamat] und Nickel-bis [di(heptafluorbutyl)-dithiocarbamat] werden beschrieben. Das Nickel-bis[di(pentafluorpropyl)dithiocarbamat] besitzt die kleinsten Retentionszeiten sowohl auf gepackten wie auf Capillarsäulen.
Fresenius Journal of Analytical Chemistry | 1982
Hans Meierer; Rolf Neeb
SummaryDecomposition effects occurring during the gaschromatographic determination of Zn-bis[di(trifluorethyl)-dithiocarbamate] on packed columns are investigated with the aid of a radioactive 65Zn-chelate. It is concluded that for the gas-chromatographic determination of small amounts of Zn capillary columns are better suited.ZusammenfassungDie bei der gas-chromatographischen Bestimmung des Zn-bis[di(trifluorethyl)dithiocarbamats] auftretenden Zersetzungserscheinungen auf gepackten Säulen wurden mit radioaktivem 65Zn-Chelat verfolgt. Es ergab sich, daß für die Bestimmung kleiner Mengen Zink Capillarsäulen besser geeignet sind.
Archive | 1983
Hans Meierer; Rolf Neeb
Fresenius Journal of Analytical Chemistry | 1983
Hans Meierer; Rolf Neeb
Archive | 1982
Jodelle S. W. Magner; Hans Meierer; Rolf Neeb
Archive | 1982
Hans Meierer; Rolf Neeb
Archive | 1982
G. Hartmetz; Geoffrey R. Scollary; Hans Meierer; Axel Meyer; Rolf Neeb