Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Harald Greiss is active.

Publication


Featured researches published by Harald Greiss.


Europace | 2013

Cryoballoon ablation of paroxysmal atrial fibrillation: 5-year outcome after single procedure and predictors of success.

Thomas Neumann; Maciej Wójcik; Alexander Berkowitsch; Damir Erkapic; Sergey Zaltsberg; Harald Greiss; Dimitri Pajitnev; Stefan Lehinant; Jörn Schmitt; Christian W. Hamm; Heinz F. Pitschner; Malte Kuniss

AIMS Long-term efficacy following cryoballoon (CB) ablation of atrial fibrillation (AF) remains unknown. This study describes 5 years follow-up results and predictors of success of CB ablation in patients with paroxysmal atrial fibrillation (PAF). METHODS AND RESULTS In total, 163 patients were enrolled with symptomatic, drug refractory PAF. Pulmonary vein isolation (PVI) with CB technique was performed. Primary endpoint of this consecutive single-centre study was first electrocardiogram-documented recurrence of AF, atrial tachycardia or atrial flutter (AFLAT). Five years success rate after single CB ablation was 53%. In 70% of the patients acute complete PVI was achieved with a single 28 mm balloon. The univariate predictors of AFLAT recurrence were (1) size of left atrium, with normalized left atrium (NLA) ≥10.25 [hazard ratios (HR) of 1.81, 95% confidence interval (CI): 1.28-2.56] when compared with NLA <10.25 (35% vs. 53%, P = 0.0001) and (2) renal function, with impaired glomerular filtration rate (GFR) <80 ml/min (HR of 1.26, 95% CI: 1.02-1.57) when compared with GFR ≥80 ml/min (45% vs. 53%, P = 0.041). Normalized left atrium ≥10.25 was the sole independent predictor for outcome (HR 2.11; 95% CI: 1.34-3.31; P = 0.0001). CONCLUSIONS Sinus rhythm can be maintained in a substantial proportion of patients with PAF even 5 years after circumferential PVI using CB ablation. The rate of decline in freedom from AFLAT was highest within the first 12 months after the index procedure. The patients with enlarged left atrium and/or impaired renal function have lower outcome.


Journal of Cardiovascular Electrophysiology | 2005

Cryocatheter Ablation of Right Ventricular Outflow Tract Tachycardia

Klaus Kurzidim; Hans‐Jürgen Schneider; Malte Kuniss; Johannes Sperzel; Harald Greiss; Alexander Berkowitsch; Heinz F. Pitschner

Introduction: Cryocatheter techniques have been successfully applied to treat supraventricular tachycardia but there are no reports on their value in treating ventricular tachycardia (VT). We present our initial experience with cryocatheter ablation of right ventricular outflow tract (RVOT) tachycardia.


Pacing and Clinical Electrophysiology | 2005

Usefulness of atrial fibrillation burden as a predictor for success of pulmonary vein isolation.

Alexander Berkowitsch; Harald Greiss; Dejan Vukajlovic; Malte Kuniss; Thomas Neumann; Sergej Zaltsberg; Klaus Kurzidim; Christian W. Hamm; Heinz F. Pitschner

Background: The definition of symptomatic improvement after pulmonary vein isolation (PVI) is controversial. We assessed primarily the usefulness and predictive accuracy (PA) of AF (atrial fibrillation) burden (AFB) within the first 3 months after the procedure as an early predictor for curative success as well as reduction of symptoms.


Europace | 2015

Clinical impact of a novel three-dimensional electrocardiographic imaging for non-invasive mapping of ventricular arrhythmias-a prospective randomized trial.

Damir Erkapic; Harald Greiss; Dmitri Pajitnev; Sergey Zaltsberg; Nicolas Deubner; Alexander Berkowitsch; Susanne Möllman; Johannes Sperzel; Andreas Rolf; Jörn Schmitt; Christian W. Hamm; Malte Kuniss; Thomas Neumann

AIMS ECVUE™ technology, a novel, three-dimensional, non-invasive mapping system, offers a unique arrhythmia characterization and localization. We sought to evaluate the clinical impact of this system in routine clinical mapping and ablation of ventricular arrhythmias (VAs). METHODS AND RESULTS Patients with monomorphic premature ventricular contractions with or without monomorphic ventricular tachycardia were enrolled prospectively and randomized into two groups: ventricular ectopy localization using either 12-lead electrocardiogram (ECG) algorithms or with ECVUE™, followed by conventional guided ablation. Forty-two patients were enrolled in the study. The ECVUE™ system accurately identified both the chamber and sub-localized the VA origin in 20 of 21 (95.2%) patients. In contrast, using 12-lead ECG algorithms, the chamber was accurately diagnosed in 16 of 21 (76.2%) patients, while the arrhythmia origin in only 8 of 21 (38.1%), (P = 0.001 vs. ECVUE™). Acute success in ablation was achieved in all patients. Regarding the number of radiofrequency-energy applications (in total 2 vs. 4, P = 0.005) in the ECVUE™ arm, ablation was more precise than the ECG group which used standard of care activation and pace mapping-guided ablation. Three months success in ablation was 95.2% for the ECVUE™ and 100% for the ECG group (P = ns). Time to ablation was 35.3 min in the conventional arm and 24.4 min in ECVUE Group, (P = 0.035). The X-ray radiation exposure was 3.21 vs. 0.39 mSv, P = 0.001 for the ECVUE™ group and ECG group. CONCLUSION ECVUE™ technology offers a clinically useful tool to map VAs with high accuracy and more targeted ablations superior to the body surface ECG but had significantly higher radiation exposure due to computed tomography scan.


Pacing and Clinical Electrophysiology | 2006

Acute Success and Persistence of Bidirectional Conduction Block in the Cavotricuspid Isthmus One Month Post Cryocatheter Ablation of Common Atrial Flutter

Malte Kuniss; Klaus Kurzidim; Harald Greiss; Alexander Berkowitsch; Johannes Sperzel; Christian W. Hamm; Heinz F. Pitschner

Introduction: Cryoablation is successful in the treatment of common atrial flutter. Long‐term clinical success is mainly dependent on persistence of bidirectional conduction block (BCB) in the inferior cavotricuspid isthmus (CTI). Only few data on persistence of BCB post cryoablation with the reported technique are available. This prospective study aimed to test efficacy of cryo energy and persistence of BCB in the CTI 1 month post cryoablation.


Pacing and Clinical Electrophysiology | 2005

A decrease in pulmonary vein diameter after radiofrequency ablation predicts the development of severe stenosis.

Alexander Berkowitsch; Thomas Neumann; Okan Ekinci; Harald Greiss; Thorsten Dill; Klaus Kurzidim; Malte Kuniss; Hans Jürgen Schneider; Heinz F. Pitschner

A decrease in ostial pulmonary vein (PV) diameter was observed in patients on the day after radiofrequency ablation of atrial fibrillation (AF). This study examined whether a relative reduction in PV diameter on day 1 (RRPVD1) after the procedure predicts the late development of severe PV stenosis (PVS). The study included 104 consecutive patients (mean age = 55 years, range 46–61, 34 women) with drug refractory AF. Pulmonary vein diameter was measured using MR angiography (MRA) on the day before and on day 1 after the ablation procedure. The MRA was repeated every 3 months after the procedure. Severe PVS was defined as a >70% diameter reduction from the initial ostial diameter. The cut‐off of RRPVD1 was prespecified as 25% decrease in initial diameter. The data are presented as medians and interquartile range. A total of 357 PV were treated. The RRPVD1 was 0.0% (0.0–11.1%). Severe PVS was found in 18 PV during a follow‐up of 12 months (range 6–13). The log‐rank analysis confirmed a strong association between a RRPVD1 ≥25% and the development of PVS (hazard ratio: 7.1; 95% confidence interval 3.8–13.5, P < 0.0001). By multivariate Cox regression model, after adjustment of procedure variables, RRPVD1 was the strongest predictor of development of severe PVS. RRPVD1 ≥25% was a strong independent predictor of development of severe PVS.


Journal of Cardiovascular Electrophysiology | 2018

Second-generation cryoballoon ablation for treatment of persistent atrial fibrillation: Three-year outcome and predictors of recurrence after a single procedure

Ersan Akkaya; Alexander Berkowitsch; Sergej Zaltsberg; Harald Greiss; Christian W. Hamm; Johannes Sperzel; Thomas Neumann; Malte Kuniss

Data on long‐term outcomes of cryoballoon (CB) ablation for treatment of persistent atrial fibrillation (AF) are sparse. Here, we report the first 3‐year follow‐up results and predictors of success for catheter ablation using the second‐generation CB in patients with persistent AF.


Journal of Cardiovascular Electrophysiology | 2018

Ice or fire? Comparison of second-generation cryoballoon ablation and radiofrequency ablation in patients with symptomatic persistent atrial fibrillation and an enlarged left atrium

Ersan Akkaya; Alexander Berkowitsch; Sergej Zaltsberg; Harald Greiss; Christian W. Hamm; Johannes Sperzel; Thomas Neumann; Malte Kuniss

We aimed to compare arrhythmia recurrence rates after second‐generation cryoballoon (CB‐Adv) ablation and radiofrequency (RF) ablation in patients with symptomatic persistent atrial fibrillation (AF) and left atrial (LA) enlargement.


International Journal of Cardiology | 2017

How safe are NOACs compared with phenprocoumon after pulmonary vein isolation with the cryoballoon technique using purse-string suture closure?

Ersan Akkaya; Alexander Berkowitsch; Sergej Zaltsberg; Nikolas Deubner; Harald Greiss; Andreas Hain; Christian W. Hamm; Johannes Sperzel; Malte Kuniss; Thomas Neumann

INTRODUCTION The aim of this observational study was to compare the postprocedural incidence of bleeding and thromboembolic complications associated with novel oral anticoagulants (NOACs) with that of interrupted and continuous phenprocoumon after pulmonary vein isolation (PVI) using a purse-string suture (PSS) closure of the puncture site. METHODS AND RESULTS Consecutive patients who had undergone PVI via cryoballoon ablation were divided into the following groups: (1) interrupted phenprocoumon with heparin bridging (n=101), (2) continuous phenprocoumon targeting an internationally normalized ratio>2 (n=70), and (3) NOACs without bridging that were restarted 2-4h after the procedure (n=185). Protamine was not administered after venous closure with PSS at the end of the procedure. The total complication rate was significantly lower in group 3 than in groups 1 and 2 (1.62% vs. 6.93% vs. 7.14%, p=0.04). The hospital costs were lower and the hospital stay length was significantly shorter (4484±3742 vs. 6082±4044 Euro vs. 4908±2925, p=0.03; 1.94±1.67 vs. 2.70±1.80 vs. 2.19±1.30days, p<0.01). No thromboembolic event occurred. Vascular complications were the most common complications noted (80%). The occurrence of any complication led to a significantly longer hospital stay (5 vs. 2days, p<0.01) and higher costs (10,052±6241 Euro vs. 4747±3447, p<0.01). The vascular complication rate after PSS was independent of intraprocedural heparin dosage and activated clotting time. CONCLUSIONS NOACs have a lower complication rate and appear to be safer in this setting than phenprocoumon. The hospital costs and hospital stay length after PVI was significantly reduced in patients treated with NOACs compared with phenprocoumon.


Europace | 2017

PLAAF score as a novel predictor of long-term outcome after second-generation cryoballoon pulmonary vein isolation

Ersan Akkaya; Alexander Berkowitsch; Harald Greiss; Christian W. Hamm; Johannes Sperzel; Thomas Neumann; Malte Kuniss

Aims Predictors of atrial arrhythmia recurrence have not been described in a long-term follow-up study of patients undergoing pulmonary vein isolation (PVI) using the cryoballoon technique. We aimed to evaluate the efficacy of a second-generation cryoballoon and identify pre-procedural predictors of 3-year outcome after PVI. Methods and results For this observational cohort study, we enrolled 440 patients ablated at our institution with a second-generation cryoballoon. The endpoint was the first documented recurrence (>30 s) of atrial fibrillation (AF), atrial flutter, or atrial tachycardia after a 3-month blanking period. The impact of several pre-existing variables on clinical outcome was evaluated by univariate and multivariate analyses using the Cox proportional hazards regression model. The PLAAF (persistent AF, left atrial area, abnormal PV anatomy, AF history, female gender) score was defined to predict outcome. After a median follow-up of 36 months (interquartile range 25/75-27/42), the endpoint was achieved in 95 of 440 (21.6%) patients. Cox regression analysis showed that persistent AF, left atrial (LA) area, abnormal PV anatomy, AF history, and female gender independently predicted recurrence. The calculated optimal cut-offs for LA area and AF history were 21 cm2 and 3 years, respectively. Patients with a PLAAF score of 0 showed the best outcome, with an arrhythmia-free survival of 86.7%. Conclusion PVI using the cryoballoon technique shows acceptable long-term results depending on predictors described by the new PLAAF score, which may facilitate patient selection for PVI.

Collaboration


Dive into the Harald Greiss's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Heinz F. Pitschner

Goethe University Frankfurt

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge