Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Heinz F. Pitschner is active.

Publication


Featured researches published by Heinz F. Pitschner.


Europace | 2013

Cryoballoon ablation of paroxysmal atrial fibrillation: 5-year outcome after single procedure and predictors of success.

Thomas Neumann; Maciej Wójcik; Alexander Berkowitsch; Damir Erkapic; Sergey Zaltsberg; Harald Greiss; Dimitri Pajitnev; Stefan Lehinant; Jörn Schmitt; Christian W. Hamm; Heinz F. Pitschner; Malte Kuniss

AIMS Long-term efficacy following cryoballoon (CB) ablation of atrial fibrillation (AF) remains unknown. This study describes 5 years follow-up results and predictors of success of CB ablation in patients with paroxysmal atrial fibrillation (PAF). METHODS AND RESULTS In total, 163 patients were enrolled with symptomatic, drug refractory PAF. Pulmonary vein isolation (PVI) with CB technique was performed. Primary endpoint of this consecutive single-centre study was first electrocardiogram-documented recurrence of AF, atrial tachycardia or atrial flutter (AFLAT). Five years success rate after single CB ablation was 53%. In 70% of the patients acute complete PVI was achieved with a single 28 mm balloon. The univariate predictors of AFLAT recurrence were (1) size of left atrium, with normalized left atrium (NLA) ≥10.25 [hazard ratios (HR) of 1.81, 95% confidence interval (CI): 1.28-2.56] when compared with NLA <10.25 (35% vs. 53%, P = 0.0001) and (2) renal function, with impaired glomerular filtration rate (GFR) <80 ml/min (HR of 1.26, 95% CI: 1.02-1.57) when compared with GFR ≥80 ml/min (45% vs. 53%, P = 0.041). Normalized left atrium ≥10.25 was the sole independent predictor for outcome (HR 2.11; 95% CI: 1.34-3.31; P = 0.0001). CONCLUSIONS Sinus rhythm can be maintained in a substantial proportion of patients with PAF even 5 years after circumferential PVI using CB ablation. The rate of decline in freedom from AFLAT was highest within the first 12 months after the index procedure. The patients with enlarged left atrium and/or impaired renal function have lower outcome.


Journal of Interventional Cardiac Electrophysiology | 2001

Inappropriate arrhythmia detection in implantable defibrillator therapy due to oversensing of diaphragmatic myopotentials.

Britta Schulte; Johannes Sperzel; Jörg Carlsson; Martin Dürsch; Ali Erdogan; Heinz F. Pitschner; Jörg Neuzner

Nonadequate arrhythmia detection and delivery of electrical therapy is still a main problem in current implantable cardioverter defibrillator therapy. Besides supraventricular arrhythmias extra-cardiac biosignals also can cause inadequate shock delivery. The present study focuses on nonadequate arrhythmia detection due to oversensing of diaphragmatic myopotentials. Their clinical characteristics, incidence and management are presented. Three-hundred-eighty-four recipients of a transvenous cardioverter-defibrillator who were implanted and followed-up at our institution between October 1991 and June 1999 were enrolled. During a mean follow-up of 32±25 months a total number of 139 nonadequate episodes of arrhythmia detection due to oversensing of diaphragmatic myopotentials were observed in 33 patients (8.6%). In 11 patients a total of 32 high energy shock deliveries occurred. Oversensing of diaphragmatic myopotentials was primarily observed in patients implanted with defibrillator leads providing “integrated bipolar” sensing. The vast majority of nonadequate arrhythmia detection were observed during intrinsic bradycardia heart rate and/or antibradycardia pacing. Electrical lead failure was ruled out in every patient. In 90% of the patients with a cardioverter-defibrillator providing programmable maximal sensitivity (n=16), the reduction of maximum sensitivity was effective in preventing further episodes of nonadequate arrhythmia detection. In 48% of the patients with devices without programmable maximal sensitivity (n=17), surgery revision was necessary to solve the problem.


Journal of Cardiovascular Electrophysiology | 2005

Cryocatheter Ablation of Right Ventricular Outflow Tract Tachycardia

Klaus Kurzidim; Hans‐Jürgen Schneider; Malte Kuniss; Johannes Sperzel; Harald Greiss; Alexander Berkowitsch; Heinz F. Pitschner

Introduction: Cryocatheter techniques have been successfully applied to treat supraventricular tachycardia but there are no reports on their value in treating ventricular tachycardia (VT). We present our initial experience with cryocatheter ablation of right ventricular outflow tract (RVOT) tachycardia.


Pacing and Clinical Electrophysiology | 2005

Usefulness of atrial fibrillation burden as a predictor for success of pulmonary vein isolation.

Alexander Berkowitsch; Harald Greiss; Dejan Vukajlovic; Malte Kuniss; Thomas Neumann; Sergej Zaltsberg; Klaus Kurzidim; Christian W. Hamm; Heinz F. Pitschner

Background: The definition of symptomatic improvement after pulmonary vein isolation (PVI) is controversial. We assessed primarily the usefulness and predictive accuracy (PA) of AF (atrial fibrillation) burden (AFB) within the first 3 months after the procedure as an early predictor for curative success as well as reduction of symptoms.


Pacing and Clinical Electrophysiology | 2001

Myocardial injury during radiofrequency catheter ablation: comparison of focal and linear lesions.

Joerg Carlsson; Ali Erdogan; N. Guettler; Britta Schulte; Dagmar Lay; Joerg Neuzner; Christian W. Hamm; Heinz F. Pitschner

CARLSSON, J., et al.: Myocardial Injury During Radiofrequency Catheter Ablation: Comparison of Focal and Linear Lesions. The aim of study was to investigate the extent of myocardial injury incurred by creation of continuous RF current induced linear ablation lesions (LL; ablation of atrial fibrillation, right atrial procedure) in comparison to focal RF lesions (FL; AV node reentry tachycardia, WPW tachycardia). In 23 patients with LL (age 51.3 ± 11.2 years, 18 men, 5 women) and in 16 patients with FL (age 53.9 ± 5.1 years, 8 men and 8 women), levels of creatine kinase (CK), myoglobin (MG), CKMB mass (CKMB M), CKMB activity (CKMB A), and cardiac troponin T (cTnT) were determined before and 2, 4, 8, 24, and 48 hours after ablation. CKMB A was normal in 87% in LL and 100% in FL (< 6% of CK) with median maximum CK values of 214 (45–1583) U/L in LL and 36 (29–212) U/L in FL. Peak values of all parameters were significantly higher in LL than in FL. The sensitivity of cTnT was 50% in FL and 100% in LL. In FL MG, total CK, and CKMB M were abnormal in only 12.5% of cases while in LL MG and CKMB M were pathological in 100% and total CK was abnormal in 91.3% of patients. The amount of energy and number of RF applications correlated with cTnT, MG, and CKMB M (P = 0.01). In conclusion, (1) long linear RF current lesions for ablation of atrial fibrillation are associated with significantly greater myocardial injury than focal ablations. (2) In focal lesions only cTnT provided a sensitivity of 50% in the detection of myocardial injury while in linear lesions cTnT, CKMBM, and CKMB M seemed suitable for detection of RF current induced myocardial damage with 100% sensitivity. All biochemical parameters do not differentiate patients with coronary ischemia up to 48 hours after an ablation. (3) Further investigations are necessary to determine if RF current linear lesions lead to impaired atrial contractility in cases of extensive tissue damage.


Europace | 2011

Gold vs. platinum-iridium tip catheter for cavotricuspid isthmus ablation: the AURUM 8 study.

Thorsten Lewalter; Christian Weiss; Sebastian Spencker; Werner Jung; Wilhelm Haverkamp; Stephan Willems; Thomas Deneke; Josef Kautzner; Michael Wiedemann; Jürgen Siebels; Heinz F. Pitschner; Ellen Hoffmann; G. Hindricks; Markus Zabel; Vester Eg; Harald Schwacke; Erica Mittmann-Braun; Lars Lickfett; Sabine Hoffmeister; Jochen Proff; Christian Mewis; Wolfgang R. Bauer

AIMS Gold electrodes have the theoretical advantage of creating bigger lesions than platinum-iridium (Pt-Ir) electrodes. We performed a prospective randomized study to compare the clinical efficacy of standard 8 mm Pt-Ir tip catheter (control) and 8 mm gold-tip catheters in the ablation of the cavotricuspid isthmus (CTI)-dependent atrial flutter. METHODS AND RESULTS A total of 463 patients undergoing CTI ablation in 19 clinical centres were randomized to receive the treatment by gold-tip or control catheter. The primary endpoint was cumulative radiofrequency (RF) application duration until achieving bidirectional CTI block. It did not differ significantly for the two catheters. The gold-tip catheter was, however, associated with a higher ablation success rate (94.3 vs. 89.0%, P = 0.042) and a substantially lower incidence of char and coagulum formation (4.8 vs. 37.9%, P < 0.001), which required exchange of 1 gold-tip (0.4%) and 10 control catheters (4.6%, P = 0.005). The gold-tip catheter delivered more mean power (52 ± 12 W) than the control catheter (48 ± 13 W, P < 0.001). Both mean and maximum temperatures measured by the thermocouple integrated in the catheter tip were statistically significantly lower in the gold (mean: 53.2 ± 4.7°C, max: 68.7 ± 6.6°C) than in the control catheter (54.3 ± 5.2 and 70.2 ± 7.0°C, respectively, P < 0.05). Fluoroscopy time, procedure duration, procedural-related complications, and arrhythmia recurrence during 6 months of follow-up did not differ between the two catheters. CONCLUSION Owing to a higher primary ablation success rate and reduced incidence of char/coagulum formation, gold may be preferred over Pt-Ir as electrode material for 8 mm tip catheters for CTI ablation. ClinicalTrials.gov: NCT00326001 (http://clinicaltrials.gov/ct2/show/NCT00326001).


Pacing and Clinical Electrophysiology | 2006

Acute Success and Persistence of Bidirectional Conduction Block in the Cavotricuspid Isthmus One Month Post Cryocatheter Ablation of Common Atrial Flutter

Malte Kuniss; Klaus Kurzidim; Harald Greiss; Alexander Berkowitsch; Johannes Sperzel; Christian W. Hamm; Heinz F. Pitschner

Introduction: Cryoablation is successful in the treatment of common atrial flutter. Long‐term clinical success is mainly dependent on persistence of bidirectional conduction block (BCB) in the inferior cavotricuspid isthmus (CTI). Only few data on persistence of BCB post cryoablation with the reported technique are available. This prospective study aimed to test efficacy of cryo energy and persistence of BCB in the CTI 1 month post cryoablation.


Clinical Pharmacology & Therapeutics | 1991

AF‐DX 116, a cardioselective muscarinic antagonist in humans: Pharmacodynamic and pharmacokinetic properties

Britta Schulte; Corinna Volz‐Zang; Ernst Mutschier; Cornelia Horne; Dieter Palm; Anton Wellstein; Heinz F. Pitschner

Effects of AF‐DX 116, a cardioselective antagonist, on M cholinergic receptors (M‐ChR) were studied in healthy volunteers. Occupancy of M‐ChR subtypes by drug present in plasma samples (radioreceptor assay) was compared with these effects. After an intravenous dose of AF‐DX 116 saturating greater than 90% of cardiac M2‐ChR, an increase in heart rate by 25 beats/min was observed. This cardiac receptor occupancy and effect wore off with a parallel time course within 10 hours. No inhibition of salivary flow was observed, coinciding with a lack of M3‐ChR blockade in the radioreceptor assay. β‐Adrenergic receptor blockade by propranolol did not affect either of the effects. No indication for active metabolites or stereoselective drug metabolism was found comparing HPLC and receptor assay for drug concentrations in plasma. We conclude that AF‐DX 116 may be a useful drug for the treatment of bradycardia. Its lack of troublesome side effects is the result of its selectivity for cardiac M‐ChR.


Pacing and Clinical Electrophysiology | 2003

Microwave, Irrigated, Pulsed, or Conventional Radiofrequency Energy Source: Which Energy Source for Which Catheter Ablation?

Ali Erdogan; Stephan Grumbrecht; Thomas Neumann; Joerg Neuzner; Heinz F. Pitschner

ERDOGAN, A., et al.: Microwave, Irrigated, Pulsed, or Conventional Radiofrequency Energy Source: Which Energy Source for Which Catheter Ablation? The aim of the study was to compare the diameter of endomyocardial lesions induced with the delivery of microwave, cooled, or pulsed energy versus conventional RF energy. In vitro tests were performed in fresh endomyocardial preparations of pig hearts in a 10‐L bath of NaCl 0.9% solution at 37°C and constant 1.5 L/min flow. Ablation 7 Fr catheters with 4‐mm tip electrodes were used, except for the delivery of microwave energy. Energy delivery time was set to 60 s/50 W in all experiments. Cooled energy delivery was performed with a closed irrigation catheter. Pulsed energy delivery was performed using a special controller with a duty‐cycle of 5 ms. Microwave energy was delivered with a 2.5‐GHz generator and 10‐mm antenna. Electrode temperature and impedance were measured simultaneously. After ablation, lesion length, width, and depth were measured with microcalipers, and volume calculated by a formula for ellipsoid bodies. Each energy delivery mode was tested in ten experiments. The deepest lesions were created with cooled energy delivery, and the largest volume by microwave energy delivery. Pulsed RF produced significantly deeper lesions than conventional RF energy delivery. Cooled or pulsed RF energy delivery created deeper transmural lesions than conventional RF. To create linear lesions at anatomically complex sites (isthmus), microwave energy seemed superior by rapidly creating deep and long lesions. (PACE 2003; 26:[Pt. II]:504–506)


Pacing and Clinical Electrophysiology | 2001

Possible Role of Epicardial Left Ventricular Programmed Stimulation in Brugada Syndrome

Joerg Carlsson; Ali Erdogan; Britta Schulte; Joerg Neuzner; Heinz F. Pitschner

CARLSSON, J., et al.: Possible Role of Epicardial Left Ventricular Programmed Stimulation in Brugada Syndrome. A patient with recurrent syncope due to polymorphic ventricular tachcardia was diagnosed with Brugada syndrome. Programmed right ventricular stimulation could not induce arrhythmia. Epicardial stimulation from a left ventricular site through the coronary sinus led to polymorhic VT. The stimulation protocol for risk stratification in Brugada syndrome is discussed.

Collaboration


Dive into the Heinz F. Pitschner's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Maciej Wójcik

Medical University of Lublin

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Britta Schulte

Goethe University Frankfurt

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge