Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Hendrik Kersten is active.

Publication


Featured researches published by Hendrik Kersten.


Analytical and Bioanalytical Chemistry | 2013

Generation of ion-bound solvent clusters as reactant ions in dopant-assisted APPI and APLI

Sonja Klee; Sascha Albrecht; Valerie Derpmann; Hendrik Kersten; Thorsten Benter

We provide experimental and theoretical evidence that the primary ionization process in the dopant-assisted varieties of the atmospheric pressure ionization methods atmospheric pressure photoionization and atmospheric pressure laser ionization in typical liquid chromatography–mass spectrometry settings is—as suggested in the literature—dopant radical cation formation. However, instead of direct dopant radical cation–analyte interaction—the broadly accepted subsequent step in the reaction cascade leading to protonated analyte molecules—rapid thermal equilibration with ion source background water or liquid chromatography solvents through dopant ion–molecule cluster formation occurs. Fast intracluster chemistry then leads to almost instantaneous proton-bound water/solvent cluster generation. These clusters interact either directly with analytes by ligand switching or association reactions, respectively, or further downstream in the intermediate-pressure regions in the ion transfer stages of the mass spectrometer via electrical-field-driven collisional decomposition reactions finally leading to the predominantly observed bare protonated analyte molecules [M + H]+.


Journal of the American Society for Mass Spectrometry | 2009

Evidence of neutral radical induced analyte ion transformations in APPI and Near-VUV APLI

Hendrik Kersten; Valerie Funcke; Matthias Lorenz; Klaus J. Brockmann; Thorsten Benter; Rob O’Brien

We report on the reactions of neutral radical species [OH, Cl, O(3P), H], generated in a typical atmospheric pressure ionization (API) source upon irradiation of the sample gases with either 193 nm laser radiation or 124 nm VUV light, the latter commonly used in atmospheric pressure photoionization (APPI). The present investigations focus on the polycyclic aromatic hydrocarbon pyrene as representative of the aromatic compound class. Experimental results are supported by computational methods: simple kinetic models are used to estimate the temporal evolution of the concentrations of reactants, intermediates, and final products, whereas density functional theory (DFT) energy calculations are carried out to further elucidate the proposed reaction pathways. The neutral radicals are generated upon photolysis of background water and oxygen always present in appreciable mixing ratios in typical API sources. Substantial amounts of oxygenated analyte product ions are observed using both techniques. In contrast, upon atmospheric pressure laser ionization (APLI) with 248 nm radiation, oxygenated products are virtually absent. In addition, kinetic data evaluation yielded a bimolecular rate constant of k=(1.9±0.9)×10−9 cm3 molecule−1 s−1 for the reaction of the pyrene radical cation with OH radicals.


Journal of the American Society for Mass Spectrometry | 2014

Are Clusters Important in Understanding the Mechanisms in Atmospheric Pressure Ionization? Part 1: Reagent Ion Generation and Chemical Control of Ion Populations

Sonja Klee; Valerie Derpmann; Walter Wißdorf; Sebastian Klopotowski; Hendrik Kersten; Klaus J. Brockmann; Thorsten Benter; Sascha Albrecht; Andries P. Bruins; Faezeh Dousty; Tiina J. Kauppila; Risto Kostiainen; Rob O’Brien; Damon B. Robb; Jack A. Syage

AbstractIt is well documented since the early days of the development of atmospheric pressure ionization methods, which operate in the gas phase, that cluster ions are ubiquitous. This holds true for atmospheric pressure chemical ionization, as well as for more recent techniques, such as atmospheric pressure photoionization, direct analysis in real time, and many more. In fact, it is well established that cluster ions are the primary carriers of the net charge generated. Nevertheless, cluster ion chemistry has only been sporadically included in the numerous proposed ionization mechanisms leading to charged target analytes, which are often protonated molecules. This paper series, consisting of two parts, attempts to highlight the role of cluster ion chemistry with regard to the generation of analyte ions. In addition, the impact of the changing reaction matrix and the non-thermal collisions of ions en route from the atmospheric pressure ion source to the high vacuum analyzer region are discussed. This work addresses such issues as extent of protonation versus deuteration, the extent of analyte fragmentation, as well as highly variable ionization efficiencies, among others. In Part 1, the nature of the reagent ion generation is examined, as well as the extent of thermodynamic versus kinetic control of the resulting ion population entering the analyzer region. Figureᅟ


Journal of the American Society for Mass Spectrometry | 2014

The ionization mechanisms in direct and dopant-assisted atmospheric pressure photoionization and atmospheric pressure laser ionization.

Tiina J. Kauppila; Hendrik Kersten; Thorsten Benter

AbstractA novel, gas-tight API interface for gas chromatography–mass spectrometry was used to study the ionization mechanism in direct and dopant-assisted atmospheric pressure photoionization (APPI) and atmospheric pressure laser ionization (APLI). Eight analytes (ethylbenzene, bromobenzene, naphthalene, anthracene, benzaldehyde, pyridine, quinolone, and acridine) with varying ionization energies (IEs) and proton affinities (PAs), and four common APPI dopants (toluene, acetone, anisole, and chlorobenzene) were chosen. All the studied compounds were ionized by direct APPI, forming mainly molecular ions. Addition of dopants suppressed the signal of the analytes with IEs above the IE of the dopant. For compounds with suitable IEs or Pas, the dopants increased the ionization efficiency as the analytes could be ionized through dopant-mediated gas-phase reactions, such as charge exchange, proton transfer, and other rather unexpected reactions, such as formation of [M + 77]+ in the presence of chlorobenzene. Experiments with deuterated toluene as the dopant verified that in case of proton transfer, the proton originated from the dopant instead of proton-bound solvent clusters, as in conventional open or non-tight APPI sources. In direct APLI using a 266 nm laser, a narrower range of compounds was ionized than in direct APPI, because of exceedingly high IEs or unfavorable two-photon absorption cross-sections. Introduction of dopants in the APLI system changed the ionization mechanism to similar dopant-mediated gas-phase reactions with the dopant as in APPI, which produced mainly ions of the same form as in APPI, and ionized a wider range of analytes than direct APLI. Graphical Abstractᅟ


Analytical Chemistry | 2012

Comparison of direct and alternating current vacuum ultraviolet lamps in atmospheric pressure photoionization.

Anu Vaikkinen; Markus Haapala; Hendrik Kersten; Thorsten Benter; Risto Kostiainen; Tiina J. Kauppila

A direct current induced vacuum ultraviolet (dc-VUV) krypton discharge lamp and an alternating current, radio frequency (rf) induced VUV lamp that are essentially similar to lamps in commercial atmospheric pressure photoionization (APPI) ion sources were compared. The emission distributions along the diameter of the lamp exit window were measured, and they showed that the beam of the rf lamp is much wider than that of the dc lamp. Thus, the rf lamp has larger efficient ionization area, and it also emits more photons than the dc lamp. The ionization efficiencies of the lamps were compared using identical spray geometries with both lamps in microchip APPI mass spectrometry (μAPPI-MS) and desorption atmospheric pressure photoionization-mass spectrometry (DAPPI-MS). A comprehensive view on the ionization was gained by studying six different μAPPI solvent compositions, five DAPPI spray solvents, and completely solvent-free DAPPI. The observed reactant ions for each solvent composition were very similar with both lamps except for toluene, which showed a higher amount of solvent originating oxidation products with the rf lamp than with the dc lamp in μAPPI. Moreover, the same analyte ions were detected with both lamps, and thus, the ionization mechanisms with both lamps are similar. The rf lamp showed a higher ionization efficiency than the dc lamp in all experiments. The difference between the lamp ionization efficiencies was greatest when high ionization energy (IE) solvent compositions (IEs above 10 eV), i.e., hexane, methanol, and methanol/water, (1:1 v:v) were used. The higher ionization efficiency of the rf lamp is likely due to the larger area of high intensity light emission, and the resulting larger efficient ionization area and higher amount of photons emitted. These result in higher solvent reactant ion production, which in turn enables more efficient analyte ion production.


Rapid Communications in Mass Spectrometry | 2013

Carbon disulfide as a dopant in photon-induced chemical ionization mass spectrometry

Faezeh Dousty; Robert T. O'Brien; Roland Gahler; Hendrik Kersten; Thorsten Benter

RATIONALE The addition of a dopant to an Atmospheric Pressure PhotoIonization (APPI) source of a mass spectrometer has been shown to enhance the degree of analyte ionization. A series of different dopants has been successfully utilized; however, there has been very little published on the characteristics of a good dopant. We have proposed carbon disulfide (CS2) as a novel new dopant based on its absorption cross-section for the VUV photons energy used and its unique gas-phase ion chemistry, notably the fact that it does not contain a proton. METHODS The ability of CS2 to enhance the ionization effectiveness of APPI was tested by using a group of compounds that have different proton affinities (PAs) and electron affinities (EAs). These results were compared to results obtained using the commonly used dopants, toluene and anisole. Particular attention was paid to the formation of [M](+) ions relative to [M+H](+) ions. Mass spectra were collected using a Waters Quattro Premier liquid chromatography/tandem mass spectrometry (LC/MS/MS) system equipped with a commercial Photomate™ photoionization source. RESULTS The results show that CS2 increases the ionization efficiency of most of the analytes studied in this work comparably to toluene and anisole. CS2 promotes both ionization routes of [M](+) and [M+H](+). In addition, due to the higher ionization energy (IE) of CS2 (10.01) compared to the IEs of toluene (8.83) and anisole (8.20), CS2 can enhance the ionization efficiency of analytes that cannot be enhanced with toluene and anisole. CONCLUSIONS We have determined that CS2 is a viable dopant for use in APPI sources. For some analytes, significant [M+H](+) ion signals are observed; therefore, the donated proton must come from either water clusters or solvents. In addition, CS2 promotes the ionization of analytes with low PAs and higher IEs than that of toluene and anisole.


Journal of the American Society for Mass Spectrometry | 2016

Gas Flow Dynamics in Inlet Capillaries: Evidence for non Laminar Conditions

Walter Wißdorf; David Müller; Yessica Brachthäuser; Markus Langner; Valerie Derpmann; Sebastian Klopotowski; Christine Polaczek; Hendrik Kersten; Klaus J. Brockmann; Thorsten Benter

AbstractIn this work, the characteristics of gas flow in inlet capillaries are examined. Such inlet capillaries are widely used as a first flow restriction stage in commercial atmospheric pressure ionization mass spectrometers. Contrary to the common assumption, we consider the gas flow in typical glass inlet capillaries with 0.5 to 0.6 mm inner diameters and lengths about 20 cm as transitional or turbulent. The measured volume flow of the choked turbulent gas stream in such capillaries is 0.8 L·min−1 to 1.6 L·min−1 under typical operation conditions, which is in good agreement to theoretically calculated values. Likewise, the change of the volume flow in dependence of the pressure difference along the capillary agrees well with a theoretical model for turbulent conditions as well as with exemplary measurements of the static pressure inside the capillary channel. However, the results for the volume flow of heated glass and metal inlet capillaries are neither in agreement with turbulent nor with laminar models. The velocity profile of the neutral gas in a quartz capillary with an inner diameter similar to commercial inlet capillaries was experimentally determined with spatially resolved ion transfer time measurements. The determined gas velocity profiles do not contradict the turbulent character of the flow. Finally, inducing disturbances of the gas flow by placing obstacles in the capillary channel is found to not change the flow characteristics significantly. In combination the findings suggest that laminar conditions inside inlet capillaries are not a valid primary explanation for the observed high ion transparency of inlet capillaries under common operation conditions. Graphical Abstractᅟ


Journal of the American Society for Mass Spectrometry | 2016

Design Study of an Atmospheric Pressure Photoionization Interface for GC-MS

Hendrik Kersten; Kai Kroll; Kirsten Haberer; Klaus J. Brockmann; Thorsten Benter; Amelia Peterson; Alexander Makarov

AbstractThis contribution reports on the development of an atmospheric pressure photoionization (APPI) source interfacing a gas chromatograph (GC) with a bench-top Orbitrap high resolution mass spectrometer (MS). We present efforts on method development aiming at high temperature stability (325°C), constant low impurity levels upon prolonged source operation, and efficient reaction volume irradiation combined with minimum peak broadening. The performance throughout each iterative development step was carefully assessed. The final GC-APPI-MS setup demonstrated femtogram-on-column sensitivity and chromatographic peaks of Gaussian shape with base peak widths <2 s for even the highest boiling compounds present in different EPA standard mixtures. Graphical Abstractᅟ


Journal of the American Society for Mass Spectrometry | 2015

Ionization of EPA Contaminants in Direct and Dopant-Assisted Atmospheric Pressure Photoionization and Atmospheric Pressure Laser Ionization

Tiina J. Kauppila; Hendrik Kersten; Thorsten Benter

AbstractSeventy-seven EPA priority environmental pollutants were analyzed using gas chromatography-mass spectrometry (GC-MS) equipped with an optimized atmospheric pressure photoionization (APPI) and an atmospheric pressure laser ionization (APLI) interface with and without dopants. The analyzed compounds included e.g., polycyclic aromatic hydrocarbons (PAHs), nitro compounds, halogenated compounds, aromatic compounds with phenolic, acidic, alcohol, and amino groups, phthalate and adipatic esters, and aliphatic ethers. Toluene, anisole, chlorobenzene, and acetone were tested as dopants. The widest range of analytes was ionized using direct APPI (66/77 compounds). The introduction of dopants decreased the amount of compounds ionized in APPI (e.g., 54/77 with toluene), but in many cases the ionization efficiency increased. While in direct APPI the formation of molecular ions via photoionization was the main ionization reaction, dopant-assisted (DA) APPI promoted ionization reactions, such as charge exchange and proton transfer. Direct APLI ionized a much smaller amount of compounds than APPI (41/77 compounds), showing selectivity towards compounds with low ionization energies (IEs) and long-lived resonantly excited intermediate states. DA-APLI, however, was able to ionize a higher amount of compounds (e.g. 51/77 with toluene), as the ionization took place entirely through dopant-assisted ion/molecule reactions similar to those in DA-APPI. Best ionization efficiency in APPI and APLI (both direct and DA) was obtained for PAHs and aromatics with O- and N-functionalities, whereas nitro compounds and aliphatic ethers were the most difficult to ionize. Halogenated aromatics and esters were (mainly) ionized in APPI, but not in APLI. Graphical Abstractᅟ


Analytical Chemistry | 2017

Characterization of an Airborne Laser-Spark Ion Source for Ambient Mass Spectrometry

Andreas Bierstedt; Hendrik Kersten; Reto Glaus; I. B. Gornushkin; Ulrich Panne; Jens Riedel

An airborne laser plasma is suggested as an ambient ion source for mass spectrometry. Its fundamental physical properties, such as an excellent spatial and temporal definition, high electron and ion densities and a high effective cross section in maintaining the plasma, make it a promising candidate for future applications. For deeper insights into the plasma properties, the optical plasma emission is examined and compared to mass spectra. The results show a seemingly contradictory behavior, since the emitted light reports the plasma to almost entirely consist of hot elemental ions, while the corresponding mass spectra exhibit the formation of intact molecular species. Further experiments, including time-resolved shadowgraphy, spatially resolved mass spectrometry, as well as flow-dependent emission spectroscopy and mass spectrometry, suggest the analyte molecules to be formed in the cold plasma vicinity upon interaction with reactive species formed inside the hot plasma center. Spatial separation is maintained by concentrically expanding pressure waves, inducing a strong unidirectional diffusion. The accompanying rarefaction inside the plasma center can be compensated by a gas stream application. This replenishing results in a strong increase in emission brightness, in local reactive species concentration, and eventually in direct mass spectrometric sensitivity. To determine the analytical performance of the new technique, a comparison with an atmospheric pressure chemical ionization (APCI) source was conducted. Two kitchen herbs, namely, spearmint and basil, were analyzed without any sample pretreatment. The presented results demonstrate a considerably higher sensitivity of the presented laser-spark ionization technique.

Collaboration


Dive into the Hendrik Kersten's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Rob O’Brien

University of British Columbia

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

I. Barnes

University of Wuppertal

View shared research outputs
Researchain Logo
Decentralizing Knowledge