Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Holger Eggebrecht is active.

Publication


Featured researches published by Holger Eggebrecht.


Circulation | 2010

Thirty-Day Results of the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry A European Registry of Transcatheter Aortic Valve Implantation Using the Edwards SAPIEN Valve

Martyn Thomas; Gerhard Schymik; Thomas Walther; Dominique Himbert; Thierry Lefèvre; Hendrik Treede; Holger Eggebrecht; Paolo Rubino; Iassen Michev; Rüdiger Lange; William N. Anderson; Olaf Wendler

Background— Transcatheter aortic valve implantation was developed to mitigate the mortality and morbidity associated with high-risk traditional aortic valve replacement. The Edwards SAPIEN valve was approved for transcatheter aortic valve implantation transfemoral delivery in the European Union in November 2007 and for transapical delivery in January 2008. Methods and Results— The SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry was designed to assess the initial clinical results of the Edwards SAPIEN valve in consecutive patients in Europe after commercialization. Cohort 1 consists of 1038 patients enrolled at 32 centers. Patients who were treated with the transapical approach (n=575) suffered more comorbidities than the transfemoral patients (n=463), resulting in a significantly higher logistic EuroSCORE (29.1% versus 25.7%; P<0.001). Therefore, these groups are considered different, and outcomes cannot be compared. Overall short-term procedural success was observed in 93.8%. The incidence of valve embolization was 0.3% (n=3), and coronary obstruction was reported for 0.6% (n=6 cases). Incidence of stroke was 2.5% and similar for both procedural approaches. Thirty-day mortality was 6.3% in transfemoral patients and 10.3% in transapical patients. The occurrence of vascular complications was not a predictor of <30-day mortality in the transfemoral population. Conclusion— Technical proficiency can be learned and adapted readily as demonstrated by the short-term procedural success rate and low 30-day mortality rates reported in the SOURCE Registry. Specific complication management and refinement of patient selection are needed to further improve outcomes.


European Heart Journal | 2011

Transcatheter aortic valve implantation: first results from a multi-centre real-world registry

Ralf Zahn; Ulrich Gerckens; Eberhard Grube; Axel Linke; Horst Sievert; Holger Eggebrecht; Rainer Hambrecht; Stefan Sack; Karl Eugen Hauptmann; Gert Richardt; Hans-Reiner Figulla; Jochen Senges

AIMS Treatment of elderly symptomatic patients with severe aortic stenosis and co-morbidities is challenging. Transcatheter aortic valve interventions [balloon valvuloplasty and transcatheter aortic valve implantation (TAVI)] are evolving as alternative treatment options to surgical valve replacement. We report the first results of the prospective multi-centre German Transcatheter Aortic Valve Interventions-Registry. METHODS AND RESULTS Between January 2009 and December 2009, a total of 697 patients (81.4 ± 6.3 years, 44.2% males, and logistic EuroScore 20.5 ± 13.2%) underwent TAVI. Pre-operative aortic valve area was 0.6 ± 0.2 cm² with a mean transvalvular gradient of 48.7 ± 17.2 mmHg. Transcatheter aortic valve implantation was performed percutaneously in the majority of patients [666 (95.6%)]. Only 31 (4.4%) procedures were done surgically: 26 (3.7%) transapically and 5 (0.7%) transaortically. The Medtronic CoreValve™ prosthesis was used in 84.4%, whereas the Sapien Edwards™ prosthesis was used in the remaining cases. Technical success was achieved in 98.4% with a post-operative mean transaortic pressure gradient of 5.4 ± 6.2 mmHg. Any residual aortic regurgitation was observed in 72.4% of patients, with a significant aortic insufficiency (≥Grade III) in only 16 patients (2.3%). Complications included pericardial tamponade in 1.8% and stroke in 2.8% of patients. Permanent pacemaker implantation after TAVI became necessary in 39.3% of patients. In-hospital death rate was 8.2%, and the 30-day death rate 12.4%. CONCLUSION In this real-world registry of high-risk patients with aortic stenosis, TAVI had a high success rate and was associated with moderate in-hospital complications. However, careful patient selection and continued hospital selection seem crucial to maintain these results.


Circulation | 2011

One-Year Outcomes of Cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry The European Registry of Transcatheter Aortic Valve Implantation Using the Edwards SAPIEN Valve

Martyn Thomas; Gerhard Schymik; Thomas Walther; Dominique Himbert; Thierry Lefèvre; Hendrik Treede; Holger Eggebrecht; Paolo Rubino; Antonio Colombo; Rüdiger Lange; Rebecca R. Schwarz; Olaf Wendler

Background— Transcatheter aortic valve implantation was developed to provide a therapeutic option for patients considered to be ineligible for, and to mitigate mortality and morbidity associated with, high-risk surgical aortic valve replacement. Methods and Results— The Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry was designed to assess initial post commercial clinical transcatheter aortic valve implantation results of the Edwards SAPIEN valve in consecutive patients in Europe. Cohort 1 consists of 1038 patients enrolled at 32 centers. One-year outcomes are presented. Patients with the transapical approach (n=575) suffered more comorbidities than transfemoral patients (n=463) with a significantly higher logistic EuroSCORE (29% versus 25.8%; P=0.007). These groups are different; therefore, outcomes cannot be directly compared. Total Kaplan Meier 1-year survival was 76.1% overall, 72.1% for transapical and 81.1% for transfemoral patients, and 73.5% of surviving patients were in New York Heart Association (NYHA) class I or II at 1 year. Combined transapical and transfemoral causes of death were cardiac in 25.1%, noncardiac in 49.2%, and unknown in 25.7%. Pulmonary complications (23.9%), renal failure (12.5%), cancer (11.4%), and stroke (10.2%) were the most frequent noncardiac causes of death. Multivariable analysis identified logistic EuroSCORE, renal disease, liver disease, and smoking as variables with the highest hazard ratios for 1-year mortality whereas carotid artery stenosis, hyperlipidemia, and hypertension were associated with lower mortality. Conclusion— The SOURCE Registry is the largest consecutively enrolled registry for transcatheter aortic valve implantation procedures. It demonstrates that with new transcatheter aortic techniques excellent 1-year survival in high-risk and inoperable patients is achievable and provides a benchmark against which future transcatheter aortic valve implantation cohorts and devices can be measured.


Circulation | 2009

Randomized comparison of strategies for type B aortic dissection: the INvestigation of STEnt Grafts in Aortic Dissection (INSTEAD) trial.

Christoph Nienaber; Hervé Rousseau; Holger Eggebrecht; Stephan Kische; Rossella Fattori; Tim C. Rehders; Günther Kundt; Dierk Scheinert; Martin Czerny; Tilo Kleinfeldt; Burkhart Zipfel; Louis Labrousse; Hüseyin Ince

Background— Thoracic endovascular aortic repair (TEVAR) represents a novel concept for type B aortic dissection. Although life-saving in acute emergencies, outcomes and survival of TEVAR in stable dissection are unknown. Methods and Results— One hundred forty patients in stable clinical condition at least 2 weeks after index dissection were randomly subjected to elective stent-graft placement in addition to optimal medical therapy (n=72) or to optimal medical therapy alone (n=68) with surveillance (arterial pressure according to World Health Organization guidelines ≤120/80 mm Hg). The primary end point was all-cause death at 2 years, whereas aorta-related death, progression (with need for conversion or additional endovascular or open surgery), and aortic remodeling were secondary end points. There was no difference in all-cause deaths, with a 2-year cumulative survival rate of 95.6±2.5% with optimal medical therapy versus 88.9±3.7% with TEVAR (P=0.15); the trial, however, turned out to be underpowered. Moreover, the aorta-related death rate was not different (P=0.44), and the risk for the combined end point of aorta-related death (rupture) and progression (including conversion or additional endovascular or open surgery) was similar (P=0.65). Three neurological adverse events occurred in the TEVAR group (1 paraplegia, 1 stroke, and 1 transient paraparesis), versus 1 case of paraparesis with medical treatment. Finally, aortic remodeling (with true-lumen recovery and thoracic false-lumen thrombosis) occurred in 91.3% of patients with TEVAR versus 19.4% of those who received medical treatment (P<0.001), which suggests ongoing aortic remodeling. Conclusions— In the first randomized study on elective stent-graft placement in survivors of uncomplicated type B aortic dissection, TEVAR failed to improve 2-year survival and adverse event rates despite favorable aortic remodeling. Clinical Trial Registration— URL: http://www.clinicaltrials.gov. Unique identifier: NCT00525356.


Heart | 2011

Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry

Mohamed Abdel-Wahab; Ralf Zahn; Martin Horack; Ulrich Gerckens; Gerhard Schuler; Horst Sievert; Holger Eggebrecht; Jochen Senges; Gert Richardt

Background Significant aortic regurgitation (AR) is rare following surgical aortic valve replacement and has been associated with worse outcome. Following transcatheter aortic valve implantation (TAVI), AR is common, but little is known about its determinants and its effect on clinical outcome. Objective To evaluate early outcome and risk factors possibly associated with AR after TAVI. Methods Data were analysed from 690 patients with severe aortic stenosis treated with TAVI enrolled in the prospective multicentre German transcatheter aortic valve interventions registry. The occurrence of AR was evaluated angiographically after device deployment and removal of the catheter and guidewire. Significant AR was defined as AR≥2/4. Results The study populations mean age was 81.4±6.3 years and men represented 44%. The mean logistic Euroscore was 20.4±13.1%. Overall, 84% of patients received the Medtronic CoreValve system and 16% received the Edwards Sapien valve. Significant AR occurred in 119 patients (17.2%). Factors independently associated with significant AR were aortic valve area (adjusted OR=0.10), annulus measurement by transoesophageal echocardiography (adjusted OR=1.94), male gender (adjusted OR=1.80), cardiogenic shock (adjusted OR=1.94) and renal failure (adjusted OR=0.53). In-hospital death rates were significantly higher in patients with significant AR than in those with no/mild AR (15.1% vs 6.7%, OR=2.50, 95% CI 1.37 to 4.55), as were rates of low cardiac output (20% vs 4.4%) and respiratory failure (16.5% vs 7.1%). Using multivariate analysis, the presence of post-procedural AR≥2/4 remained a strong independent predictor of in-hospital death (adjusted OR=2.43, 95% CI 1.22 to 4.85). Conclusion Significant AR after TAVI is common and is associated with increased in-hospital mortality. Long-term follow-up is critical to further define the impact of residual AR on clinical outcome. Until these data become available, every effort should be made to prevent and treat this complication.


Circulation | 2011

One-Year Outcomes of Cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry

Martyn Thomas; Gerhard Schymik; Thomas Walther; Dominique Himbert; Thierry Lefèvre; Hendrik Treede; Holger Eggebrecht; Paolo Rubino; Antonio Colombo; Rüdiger Lange; Rebecca R. Schwarz; Olaf Wendler

Background— Transcatheter aortic valve implantation was developed to provide a therapeutic option for patients considered to be ineligible for, and to mitigate mortality and morbidity associated with, high-risk surgical aortic valve replacement. Methods and Results— The Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry was designed to assess initial post commercial clinical transcatheter aortic valve implantation results of the Edwards SAPIEN valve in consecutive patients in Europe. Cohort 1 consists of 1038 patients enrolled at 32 centers. One-year outcomes are presented. Patients with the transapical approach (n=575) suffered more comorbidities than transfemoral patients (n=463) with a significantly higher logistic EuroSCORE (29% versus 25.8%; P=0.007). These groups are different; therefore, outcomes cannot be directly compared. Total Kaplan Meier 1-year survival was 76.1% overall, 72.1% for transapical and 81.1% for transfemoral patients, and 73.5% of surviving patients were in New York Heart Association (NYHA) class I or II at 1 year. Combined transapical and transfemoral causes of death were cardiac in 25.1%, noncardiac in 49.2%, and unknown in 25.7%. Pulmonary complications (23.9%), renal failure (12.5%), cancer (11.4%), and stroke (10.2%) were the most frequent noncardiac causes of death. Multivariable analysis identified logistic EuroSCORE, renal disease, liver disease, and smoking as variables with the highest hazard ratios for 1-year mortality whereas carotid artery stenosis, hyperlipidemia, and hypertension were associated with lower mortality. Conclusion— The SOURCE Registry is the largest consecutively enrolled registry for transcatheter aortic valve implantation procedures. It demonstrates that with new transcatheter aortic techniques excellent 1-year survival in high-risk and inoperable patients is achievable and provides a benchmark against which future transcatheter aortic valve implantation cohorts and devices can be measured.


Circulation | 2010

Silent and Apparent Cerebral Ischemia After Percutaneous Transfemoral Aortic Valve Implantation A Diffusion-Weighted Magnetic Resonance Imaging Study

Philipp Kahlert; Stephan Knipp; Marc Schlamann; Matthias Thielmann; Fadi Al-Rashid; Marcel Weber; Uwe Johansson; Daniel Wendt; Heinz Jakob; Michael Forsting; Stefan Sack; Raimund Erbel; Holger Eggebrecht

Background— The risk of stroke after transfemoral aortic valve implantation (TAVI) due to dislodgement and subsequent embolization of debris from aortic arch atheroma or from the calcified valve itself ranges between 2% and 10%. The rate of clinically silent cerebral ischemia is unknown but may be even higher. Methods and Results— Thirty-two patients who underwent TAVI with the use of a balloon-expandable (n=22) or self-expandable (n=10) stent valve prosthesis were included in this descriptive study and compared with a historical control group of 21 patients undergoing open surgical aortic valve replacement. Periprocedural apparent and silent cerebral ischemia was assessed by neurological testing and serial cerebral diffusion-weighted magnetic resonance imaging at baseline, at 3.4 (2.5 to 4.4) days after the procedure, and at 3 months. TAVI was successful in all patients. After the procedure, new foci of restricted diffusion on cerebral diffusion-weighted magnetic resonance imaging were found in 27 of 32 TAVI patients (84%) and were more frequent than after open surgery (10 of 21 patients [48%]; P=0.011). These lesions were usually multiple (1 to 19 per patient) and dispersed in both hemispheres in a pattern suggesting cerebral embolization. Volumes of these lesions were significantly smaller after TAVI than after surgery (77 [59 to 94] versus 224 [111 to 338] mm3; P<0.001). There were neither measurable impairments of neurocognitive function nor apparent neurological events during the in-hospital period among TAVI patients, but there was 1 stroke (5%) in the surgical patient group. On 3-month follow-up diffusion-weighted magnetic resonance imaging, there were no new foci of restricted diffusion, and there was no residual signal change associated with the majority (80%) of the foci detected in the periprocedural period. Conclusions— Clinically silent new foci of restricted diffusion on cerebral magnetic resonance imaging were detected in almost all patients (84%) undergoing TAVI. Although typically multiple, these foci were not associated with apparent neurological events or measurable deterioration of neurocognitive function during 3-month follow-up. Further work needs to be directed to determine the clinical significance of these findings in a larger patient population.


Circulation-cardiovascular Interventions | 2013

Endovascular Repair of Type B Aortic Dissection Long-term Results of the Randomized Investigation of Stent Grafts in Aortic Dissection Trial

Christoph Nienaber; Stephan Kische; Hervé Rousseau; Holger Eggebrecht; Tim C. Rehders; Guenther Kundt; Aenne Glass; Dierk Scheinert; Martin Czerny; Tilo Kleinfeldt; Burkhart Zipfel; Louis Labrousse; Rossella Fattori; Hüseyin Ince

Background—Thoracic endovascular aortic repair (TEVAR) represents a therapeutic concept for type B aortic dissection. Long-term outcomes and morphology after TEVAR for uncomplicated dissection are unknown. Methods and Results—A total of 140 patients with stable type B aortic dissection previously randomized to optimal medical treatment and TEVAR (n=72) versus optimal medical treatment alone (n=68) were analyzed retrospectively for aorta-specific, all-cause outcomes, and disease progression using landmark statistical analysis of years 2 to 5 after index procedure. Cox regression was used to compare outcomes between groups; all analyses are based on intention to treat. The risk of all-cause mortality (11.1% versus 19.3%; P=0.13), aorta-specific mortality (6.9% versus 19.3%; P=0.04), and progression (27.0% versus 46.1%; P=0.04) after 5 years was lower with TEVAR than with optimal medical treatment alone. Landmark analysis suggested a benefit of TEVAR for all end points between 2 and 5 years; for example, for all-cause mortality (0% versus 16.9%; P=0.0003), aorta-specific mortality (0% versus 16.9%; P=0.0005), and for progression (4.1% versus 28.1%; P=0.004); Landmarking at 1 year and 1 month revealed consistent findings. Both improved survival and less progression of disease at 5 years after elective TEVAR were associated with stent graft induced false lumen thrombosis in 90.6% of cases (P<0.0001). Conclusions—In this study of survivors of type B aortic dissection, TEVAR in addition to optimal medical treatment is associated with improved 5-year aorta-specific survival and delayed disease progression. In stable type B dissection with suitable anatomy, preemptive TEVAR should be considered to improve late outcome. Clinical Trial Registration—URL: http://www.clinicaltrials.gov. Unique identifier: NCT01415804.


Circulation | 2009

Retrograde ascending aortic dissection during or after thoracic aortic stent graft placement: insight from the European registry on endovascular aortic repair complications

Holger Eggebrecht; M.M. Thompson; Hervé Rousseau; Martin Czerny; Lars Lönn; Rajendra H. Mehta; Raimund Erbel

Background— Single-center reports have identified retrograde ascending aortic dissection (rAAD) as a potentially lethal complication of thoracic endovascular aortic repair (TEVAR). Methods and Results— Between 1995 and 2008, 28 centers participating in the European Registry on Endovascular Aortic Repair Complications reported a total of 63 rAAD cases (incidence, 1.33%; 95% CI, 0.75 to 2.40). Eighty-one percent of patients underwent TEVAR for acute (n=26, 54%) or chronic type B dissection (n=13, 27%). Stent grafts with proximal bare springs were used in majority of patients (83%). Only 7 (15%) patients had intraoperative rAAD, with the remaining occurring during the index hospitalization (n=10, 21%) and during follow-up (n=31, 64%). Presenting symptoms included acute chest pain (n=16, 33%), syncope (n=12, 25%), and sudden death (n=9, 19%) whereas one fourth of patients were asymptomatic (n=12, 25%). Most patients underwent emergency (n=25) or elective (n=5) surgical repair. Outcome was fatal in 20 of 48 patients (42%). Causes of rAAD included the stent graft itself (60%), manipulation of guide wires/sheaths (15%), and progression of underlying aortic disease (15%). Conclusions— The incidence of rAAD was low (1.33%) in the present analysis with high mortality (42%). Patients undergoing TEVAR for type B dissection appeared to be most prone for the occurrence of rAAD. This complication occurred not only during the index hospitalization but after discharge up to 1050 days after TEVAR. Importantly, the majority of rAAD cases were associated with the use of proximal bare spring stent grafts with direct evidence of stent graft–induced injury at surgery or necropsy in half of the patients.


Eurointervention | 2012

Risk of stroke after transcatheter aortic valve implantation (TAVI): a meta-analysis of 10,037 published patients.

Holger Eggebrecht; Axel Schmermund; Thomas Voigtländer; Philipp Kahlert; Raimund Erbel; Rajendra H. Mehta

AIMS Transcatheter aortic valve implantation (TAVI) represents a novel treatment option for inoperable or high surgical risk patients with severe symptomatic aortic valve disease. Recent randomised studies have raised major safety concerns because of increased stroke/transient ischemic attack (TIA) rates with TAVI compared to medical treatment and conventional aortic valve replacement. We aimed to review all currently published literature and estimate the incidence of periprocedural stroke and outcomes in patients undergoing TAVI. METHODS AND RESULTS Fifty-three studies including a total of 10,037 patients undergoing transfemoral, transapical or trans-subclavian TAVI for native aortic valve stenosis published between 01/2004 and 11/2011 were identified and included in a meta-analysis. Patients were 81.5 ± 1.8-years-old and had a mean logistic EuroSCORE of 24.77 ± 5.60%. Procedural stroke (<24 h) occurred in 1.5 ± 1.4%. The overall 30-day stroke/TIA was 3.3 ± 1.8%, with the majority being major strokes (2.9 ± 1.8%). During the first year after TAVI, stroke/TIA increased up to 5.2 ± 3.4%. Differences in stroke rates were associated with different approaches and valve prostheses used with lowest stroke rates after transapical TAVI (2.7 ± 1.4%). Average 30-day mortality was more than 3.5-fold higher in patients with compared to those without stroke (25.5 ± 21.9% vs. 6.9 ± 4.2%). CONCLUSIONS TAVI was associated with average 30-day stroke/TIA rate of 3.3 ± 1.8% (range 0-6%). Most of these strokes were major strokes and were associated with increased mortality within in the first 30 days.

Collaboration


Dive into the Holger Eggebrecht's collaboration.

Top Co-Authors

Avatar

Raimund Erbel

University of Duisburg-Essen

View shared research outputs
Top Co-Authors

Avatar

Heinz Jakob

University of Duisburg-Essen

View shared research outputs
Top Co-Authors

Avatar

Philipp Kahlert

University of Duisburg-Essen

View shared research outputs
Top Co-Authors

Avatar

Dietrich Baumgart

University of Duisburg-Essen

View shared research outputs
Top Co-Authors

Avatar

Axel Schmermund

University of Duisburg-Essen

View shared research outputs
Top Co-Authors

Avatar

Michael Haude

University of Duisburg-Essen

View shared research outputs
Top Co-Authors

Avatar

Matthias Thielmann

University of Duisburg-Essen

View shared research outputs
Top Co-Authors

Avatar

Christoph Naber

University of Duisburg-Essen

View shared research outputs
Top Co-Authors

Avatar

Daniel Wendt

University of Duisburg-Essen

View shared research outputs
Top Co-Authors

Avatar

Thomas Konorza

University of Duisburg-Essen

View shared research outputs
Researchain Logo
Decentralizing Knowledge