Analytica Chimica Acta | 2014

Multi-targeted interference-free determination of ten β-blockers in human urine and plasma samples by alternating trilinear decomposition algorithm-assisted liquid chromatography-mass spectrometry in full scan mode: comparison with multiple reaction monitoring.

Hui-Wen Gu; Hai-Long Wu; Xiao-Li Yin; Yong Li; Ya-Juan Liu; Hui Xia; Shu-Rong Zhang; Yi-Feng Jin; Xiao-Dong Sun; Ru-Qin Yu; Pengyuan Yang; Haojie Lu

β-blockers are the first-line therapeutic agents for treating cardiovascular diseases and also a class of prohibited substances in athletic competitions. In this work, a smart strategy that combines three-way liquid chromatography-mass spectrometry (LC-MS) data with second-order calibration method based on alternating trilinear decomposition (ATLD) algorithm was developed for simultaneous determination of ten β-blockers in human urine and plasma samples. This flexible strategy proved to be a useful tool to solve the problems of overlapped peaks and uncalibrated interferences encountered in quantitative LC-MS, and made the multi-targeted interference-free qualitative and quantitative analysis of β-blockers in complex matrices possible. The limits of detection were in the range of 2.0×10(-5)-6.2×10(-3) μg mL(-1), and the average recoveries were between 90 and 110% with standard deviations and average relative prediction errors less than 10%, indicating that the strategy could provide satisfactory prediction results for ten β-blockers in human urine and plasma samples only using liquid chromatography hyphenated single-quadrupole mass spectrometer in full scan mode. To further confirm the feasibility and reliability of the proposed method, the same batch samples were analyzed by multiple reaction monitoring (MRM) method. T-test demonstrated that there are no significant differences between the prediction results of the two methods. Considering the advantages of fast, low-cost, high sensitivity, and no need of complicated chromatographic and tandem mass spectrometric conditions optimization, the proposed strategy is expected to be extended as an attractive alternative method to quantify analyte(s) of interest in complex systems such as cells, biological fluids, food, environment, pharmaceuticals and other complex samples.


Journal of Chromatography B | 2014

Simultaneous determination of phenolic antioxidants in edible vegetable oils by HPLC–FLD assisted with second-order calibration based on ATLD algorithm

Jian-Yao Wang; Hai-Long Wu; Yan-Mei Sun; Hui-Wen Gu; Zhi Liu; Ya-Juan Liu; Ru-Qin Yu

A novel strategy that combines the chemometrics method with high performance liquid chromatography with fluorescence detector (HPLC-FLD) was developed for the simultaneous determination of seven phenolic antioxidants in six kinds of oil samples. After a simple dilution step, oil samples can be directly injected into the detecting system and the data were measured in a short time with a chromatographic system operating in the gradient elution mode. Since the chromatographic and spectral peaks among interesting analytes and interferences were heavily overlapped, second-order calibration method based on alternating trilinear decomposition (ATLD) algorithm which fully exploiting the second-order advantage was adopted. Successful resolution was obtained in the presence of different matrix interferences in different oil samples, and the developed approach allows the quantification of the antioxidants at levels found in edible vegetable oils, without the necessity of applying either preconcentration or extraction steps, moreover, a column washing is also not required. Meanwhile, the effectiveness and reproducibility of the proposed method were also validated by some statistical parameters like root mean squared error of prediction (RMSEP), limits of detection (LOD) and relative standard deviation (RSD). Then the proposed method was compared with several commonly selected methods in sample preparation, elution time and LOD.


Journal of Chromatography A | 2016

Chemometrics-assisted high performance liquid chromatography-diode array detection strategy to solve varying interfering patterns from different chromatographic columns and sample matrices for beverage analysis

Xiao-Li Yin; Hai-Long Wu; Hui-Wen Gu; Yong Hu; Li Wang; Hui Xia; Shou-Xia Xiang; Ru-Qin Yu

This work reports a chemometrics-assisted high performance liquid chromatography-diode array detection (HPLC-DAD) strategy to solve varying interfering patterns from different chromatographic columns and sample matrices for the rapid simultaneous determination of six synthetic colorants in five kinds of beverages with little sample pretreatment. The investigation was performed using two types of LC columns under the same elution conditions. Although analytes using different columns have different co-elution patterns that appear more seriously in complex backgrounds, all colorants were properly resolved by alternating trilinear decomposition (ATLD) method and accurate chromatographic elution profiles, spectral profiles as well as relative concentrations were obtained. The results were confirmed by those obtained from traditional HPLC-UV method at a particular wavelength and the results of both methods were consistent with each other. All results demonstrated that the proposed chemometrics-assisted HPLC-DAD method is accurate, economical and universal, and can be promisingly applied to solve varying interfering patterns from different chromatographic columns and sample matrices for the analysis of complex food samples.


Bioanalysis | 2012

Simultaneous determination of metoprolol and α-hydroxymetoprolol in human plasma using excitation–emission matrix fluorescence coupled with second-order calibration methods

Hui-Wen Gu; Hai-Long Wu; Ya-Juan Liu; Xiao-Li Yin; Zhiyi Su; Shan-Shan Li; Ru-Qin Yu

BACKGROUND Metoprolol (MET) is a β1-adrenoceptor antagonist, which is widely used in the treatment of cardiovascular diseases, and α-hydroxymetoprolol (α-OHM) is its hydroxylated metabolite. Owing to their similar structures, optimization of the condition for the chromatography approach, which is in common use for determination, is both time consuming and laborious. RESULTS A new and effective strategy that combines the excitation-emission matrix fluorescence with second-order calibration methods was developed for simultaneous determination of MET and α-OHM in human plasma. CONCLUSION Although the fluorescence spectra of MET and α-OHM overlapped and a large number of unknown and uncalibrated fluorescent components coexisted, the developed method enables accurate concentrations together with reasonable resolution of excitation and emission profiles for the analytes of interest. An additional advantage of the proposed method is that there is no need for separation and sample pretreatment, in addition to lower cost than traditional methods.


Analytica Chimica Acta | 2015

A novel fourth-order calibration method based on alternating quinquelinear decomposition algorithm for processing high performance liquid chromatography–diode array detection– kinetic-pH data of naptalam hydrolysis

Xiang-Dong Qing; Hai-Long Wu; Xi-Hua Zhang; Yong Li; Hui-Wen Gu; Ru-Qin Yu

Five-way high performance liquid chromatography-diode array detection (HPLC-DAD)-kinetic-pH data were obtained by recording the kinetic evolution of HPLC-DAD signals of samples at different pH values and a new fourth-order calibration method, alternating quinquelinear decomposition (AQQLD) based on pseudo-fully stretched matrix forms of the quinquelinear model, was developed. Simulated data were analyzed to investigate the performance of AQQLD in comparison with five-way parallel factor analysis (PARAFAC). The tested results demonstrated that AQQLD has the advantage of faster convergence rate and being insensitive to the excess component number adopted in the model. Then, they have been successfully applied to investigate quantitatively the kinetics of naptalam (NAP) hydrolysis in two practical systems. Additionally, the serious chromatographic peak shifts were accurately corrected by means of chromatographic peak alignment method based on abstract subspace difference. The good recoveries of NAP were obtained in these samples by selecting the time region of chromatogram. The elution time, spectral, kinetic time and pH profiles resolved by the chemometric techniques were in good agreement with experimental observations. It demonstrates the potential for the utilization of fourth-order data for some complex systems, opening up a new approach to fourth-order data generation and subsequent fourth-order calibration.


Journal of Chromatography B | 2016

Rapid and simultaneous determination of five vinca alkaloids in Catharanthus roseus and human serum using trilinear component modeling of liquid chromatography–diode array detection data

Zhi Liu; Hai-Long Wu; Yong Li; Hui-Wen Gu; Xiao-Li Yin; Li-Xia Xie; Ru-Qin Yu

A novel chemometrics-assisted high performance liquid chromatography method coupled with diode array detector (HPLC-DAD) was proposed for the simultaneous determination of vincristine (VCR), vinblastine (VLB), vindoline (VDL), catharanthine (CAT) and yohimbine (YHB) in Catharanthus roseus (C. roseus) and human serum samples. With the second-order advantage of the alternating trilinear decomposition (ATLD) method, the resolution and rapid determination of five components of interest in complex matrices were performed, even in the present of heavy overlaps and unknown interferences. Therefore, multi-step purification was omitted and five components could be fast eluted out within 7.5min under simple isocratic elution condition (acetonitrile/0.2% formic acid water, 37:63, v/v). Statistical parameters, such as the linear correlation coefficient (R(2)), root-mean-square error of prediction (RMSEP), limit of detection (LOD) and limit of quantitation (LOQ) had been calculated to investigate the accuracy and reliability of the method. The average recoveries of five vinca alkaloids ranged from 97.1% to 101.9% and 98.8% to 103.0% in C. roseus and human serum samples, respectively. The five vinca alkaloids were adequately determined with limits of detection (LODs) of 29.5-49.3ngmL(-1) in C. roseus and 12.4-27.2ngmL(-1) in human serum samples, respectively. The obtained results demonstrated that the analytical strategy provided a feasible alternative for synchronously monitoring the quality of raw herb and the concentration of blood drugs.


RSC Advances | 2016

Interference-free analysis of aflatoxin B1 and G1 in various foodstuffs using trilinear component modeling of excitation–emission matrix fluorescence data enhanced through photochemical derivatization

Zhi Liu; Hai-Long Wu; Hui-Wen Gu; Xiao-Li Yin; Li-Xia Xie; Yong Hu; Hui Xia; Shou-Xia Xiang; Ru-Qin Yu

A novel ‘dilute-and-shoot’ analytical strategy coupling a self-weighted alternating normalized residue fitting (SWANRF) algorithm with two-dimensional fluorescence detection enhanced through photochemical derivatization (PD) was proposed in the present work for rapid, simultaneous and accurate quantitative analysis of aflatoxin B1 and G1 in various foodstuffs (including cereals, honey, and edible oil). By coupling the predominant second-order advantage of the SWANRF algorithm with the ultra-sensitivity of fluorescence detection enhanced through off-line photochemical derivatization, the specific quantitative information of both analytes could be successfully extracted from heavily interferential matrices without complicated multi-step purification and chromatographic separation procedures. Consequently, the whole analytical time and expense were significantly decreased, accurate recoveries (with relative standard deviations, RSDs) (93.5 ± 6.6–102.8 ± 4.0% for AFB1, and 96.4 ± 3.6–107.2 ± 6.0% for AFG1) and extremely low limits of detection (LODs) (0.12–0.21 ng mL−1 for AFB1, and 0.27–0.75 ng mL−1 for AFG1) were obtained for analytical foodstuff matrices. In addition, all quantitative results of this proposed strategy were carefully compared with the standard IAC-LC-ESI+-MS method for further confirmation, which proved that SWANRF-EEMs are promising as an alternative analytical strategy for the routine analysis of multiplex aflatoxins, and a theoretical basis for developing portable detecting devices.


Journal of Chromatography A | 2015

Solving signal instability to maintain the second-order advantage in the resolution and determination of multi-analytes in complex systems by modeling liquid chromatography-mass spectrometry data using alternating trilinear decomposition method assisted with piecewise direct standardization.

Hui-Wen Gu; Hai-Long Wu; Xiao-Li Yin; Shan-Shan Li; Ya-Juan Liu; Hui Xia; Li-Xia Xie; Ru-Qin Yu; Pengyuan Yang; Haojie Lu

The application of calibration transfer methods has been successful in combination with near-infrared spectroscopy or other tools for prediction of chemical composition. One of the developed methods that can provide accurate performances is the piecewise direct standardization (PDS) method, which in this paper is firstly applied to transfer from one day to another the second-order calibration model based on alternating trilinear decomposition (ATLD) method built for the interference-free resolution and determination of multi-analytes in complex systems by liquid chromatography-mass spectrometry (LC-MS) in full scan mode. This is an example of LC-MS analysis in which interferences have been found, making necessary the use of second-order calibration because of its capacity for modeling this phenomenon, which implies analytes of interest can be resolved and quantified even in the presence of overlapped peaks and unknown interferences. Once the second-order calibration model based on ATLD method was built, the calibration transfer was conducted to compensate for the signal instability of LC-MS instrument over time. This allows one to reduce the volume of the heavy works for complete recalibration which is necessary for later accurate determinations. The root-mean-square error of prediction (RMSEP) and average recovery were used to evaluate the performances of the proposed strategy. Results showed that the number of calibration samples used on the real LC-MS data was reduced by using the PDS method from 11 to 3 while producing comparable RMSEP values and recovery values that were statistically the same (F-test, 95% confidence level) to those obtained with 11 calibration samples. This methodology is in accordance with the highly recommended green analytical chemistry principles, since it can reduce the experimental efforts and cost with regard to the use of a new calibration model built in modified conditions.


Bioanalysis | 2015

Chemometrics-assisted determination of amiloride and triamterene in biological fluids with overlapped peaks and unknown interferences

Yong Hu; Hai-Long Wu; Xiao-Li Yin; Hui-Wen Gu; Chao Kang; Shou-Xia Xiang; Hui Xia; Ru-Qin Yu

BACKGROUND Amiloride (AMI) and triamterene (TRI) are both potassium-saving diuretics, which are ordinarily used as doping to enhance the performance of athletes in sports. For the similar structures and complex matrices existence, chromatography and extraction are commonly employed to realize the determination of AMI and TRI in biological fluids, which are very time-consuming and laborious. RESULTS A novel method is presented to simultaneous interference-free determination of AMI and TRI in complex biological fluids samples using excitation-emission matrix fluorescence coupled with second-order calibration method based on alternating normalization-weight error algorithm. CONCLUSION The proposed method can obtain accurate qualitative and quantitative information of the analytes, even in the presence of the interference from complex biological fluids, which requires few prior purification and separation procedures.


Analytical Methods | 2014

An alternating coupled two-unequal residual functions algorithm for second-order calibration

Yong Li; Hai-Long Wu; Chong-Chong Nie; Hui-Wen Gu; Xiang-Dong Qing; Qi Zuo; Ru-Qin Yu

In this paper, a novel algorithm, alternating coupled two-unequal residual functions (ACTUF), has been presented to deal with three-way data for second-order calibration and it is able to achieve the important second-order advantage. This new algorithm resolves the parameter matrices by minimizing the two functions of measurement residuals and parameter residuals. Compared with two widely used algorithms, i.e., PARAFAC and SWATLD, the performance of the new algorithm is evaluated by using two simulation and two real data arrays in some aspects, such as noise, collinearity, analysis speed and solution. The results reveal that ACTUF can not only retain the second-order advantage, but also be insensitive to excessive component numbers and hold strong anti-noise tolerance. Besides, compared to the other two algorithms, ACTUF can successfully deal with the problems due to severe collinearity.

Collaboration


Dive into the Hui-Wen Gu's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Ya-Juan Liu

Lille University of Science and Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge