Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Igor Savukov is active.

Publication


Featured researches published by Igor Savukov.


Journal of Magnetic Resonance | 2008

Microtesla MRI of the human brain combined with MEG.

Vadim S. Zotev; Petr L. Volegov; Igor Savukov; Michelle A. Espy; John C. Mosher; John J. Gomez; Robert H. Kraus

One of the challenges in functional brain imaging is integration of complementary imaging modalities, such as magnetoencephalography (MEG) and functional magnetic resonance imaging (fMRI). MEG, which uses highly sensitive superconducting quantum interference devices (SQUIDs) to directly measure magnetic fields of neuronal currents, cannot be combined with conventional high-field MRI in a single instrument. Indirect matching of MEG and MRI data leads to significant co-registration errors. A recently proposed imaging method--SQUID-based microtesla MRI--can be naturally combined with MEG in the same system to directly provide structural maps for MEG-localized sources. It enables easy and accurate integration of MEG and MRI/fMRI, because microtesla MR images can be precisely matched to structural images provided by high-field MRI and other techniques. Here we report the first images of the human brain by microtesla MRI, together with auditory MEG (functional) data, recorded using the same seven-channel SQUID system during the same imaging session. The images were acquired at 46 microT measurement field with pre-polarization at 30 mT. We also estimated transverse relaxation times for different tissues at microtesla fields. Our results demonstrate feasibility and potential of human brain imaging by microtesla MRI. They also show that two new types of imaging equipment--low-cost systems for anatomical MRI of the human brain at microtesla fields, and more advanced instruments for combined functional (MEG) and structural (microtesla MRI) brain imaging--are practical.


Proceedings of the National Academy of Sciences of the United States of America | 2008

Zero-field remote detection of NMR with a microfabricated atomic magnetometer

Micah P. Ledbetter; Igor Savukov; Dmitry Budker; Vishal Shah; Svenja Knappe; John Kitching; David Michalak; Shoujun Xu; Alexander Pines

We demonstrate remote detection of nuclear magnetic resonance (NMR) with a microchip sensor consisting of a microfluidic channel and a microfabricated vapor cell (the heart of an atomic magnetometer). Detection occurs at zero magnetic field, which allows operation of the magnetometer in the spin-exchange relaxation-free (SERF) regime and increases the proximity of sensor and sample by eliminating the need for a solenoid to create a leading field. We achieve pulsed NMR linewidths of 26 Hz, limited, we believe, by the residence time and flow dispersion in the encoding region. In a fully optimized system, we estimate that for 1 s of integration, 7 × 1013 protons in a volume of 1 mm3, prepolarized in a 10-kG field, can be detected with a signal-to-noise ratio of ≈3. This level of sensitivity is competitive with that demonstrated by microcoils in 100-kG magnetic fields, without requiring superconducting magnets.


Journal of Magnetic Resonance | 2009

MRI with an atomic magnetometer suitable for practical imaging applications

Igor Savukov; Vadim S. Zotev; Petr L. Volegov; Michelle A. Espy; John J. Gomez; Robert H. Kraus

Conventionally implemented MRI is performed in a strong magnetic field, typically >1T. The high fields, however, can lead to many limitations. To overcome these limitations, ultra-low field (ULF) [or microtesla] MRI systems have been proposed and implemented. To-date such systems rely on low-Tc Superconducting Quantum Interference Devices (SQUIDs) leading to the requirement of cryogens. In this letter, we report ULF-MRI obtained with a non-cryogenic atomic magnetometer. This demonstration creates opportunities for developing inexpensive and widely applicable MRI scanners.


Superconductor Science and Technology | 2010

Ultra-low-field MRI for the detection of liquid explosives

Michelle A. Espy; Mark Flynn; John J. Gomez; Christina J. Hanson; Robert H. Kraus; Per E. Magnelind; Karlene Maskaly; Shaun Newman; Tuba Owens; Mark Peters; Henrik Sandin; Igor Savukov; Larry J. Schultz; Algis Urbaitis; Petr L. Volegov; Vadim S. Zotev

Recently it has become both possible and practical to perform MR at magnetic fields from µT to mT, the so-called ultra-low field (ULF) regime. SQUID sensor technology allows for ultra-sensitive detection while pulsed pre-polarizing fields greatly enhance signal. The instrumentation allows for unprecedented flexibility in signal acquisition sequences and simplified MRI instrumentation. Here we present the results for a new application of ULF MRI and relaxometry for the detection and characterization of liquids. We briefly describe the motivation and advantages of the ULF MR approach. We then present recent results from a 7- channel ULF MRI/relaxometer system constructed to non-invasively inspect liquids at a security check-point for the presence of hazardous material. The instrument was fielded to the Albuquerque International Airport in December, 2008, and results from that endeavor are also presented.


Journal of Magnetic Resonance | 2010

Microtesla MRI with dynamic nuclear polarization

Vadim S. Zotev; Tuba Owens; Igor Savukov; John J. Gomez; Michelle A. Espy

Magnetic resonance imaging at microtesla fields is a promising imaging method that combines the pre-polarization technique and broadband signal reception by superconducting quantum interference device (SQUID) sensors to enable in vivo MRI at microtesla-range magnetic fields similar in strength to the Earth magnetic field. Despite significant advances in recent years, the potential of microtesla MRI for biomedical imaging is limited by its insufficient signal-to-noise ratio due to a relatively low sample polarization. Dynamic nuclear polarization (DNP) is a widely used approach that allows polarization enhancement by 2-4 orders of magnitude without an increase in the polarizing field strength. In this work, the first implementation of microtesla MRI with Overhauser DNP and SQUID signal detection is described. The first measurements of carbon-13 NMR spectra at microtesla fields are also reported. The experiments were performed at the measurement field of 96 μT, corresponding to Larmor frequency of 4 kHz for protons and 1 kHz for carbon-13. The Overhauser DNP was carried out at 3.5-5.7 mT fields using rf irradiation at 120 MHz. Objects for imaging included water phantoms and a cactus plant. Aqueous solutions of metabolically relevant sodium bicarbonate, pyruvate, alanine, and lactate, labeled with carbon-13, were used for NMR studies. All the samples were doped with TEMPO free radicals. The Overhauser DNP enabled nuclear polarization enhancement by factor as large as -95 for protons and as large as -200 for carbon-13, corresponding to thermal polarizations at 0.33 T and 1.1 T fields, respectively. These results demonstrate that SQUID-based microtesla MRI can be naturally combined with Overhauser DNP in one system, and that its signal-to-noise performance is greatly improved in this case. They also suggest that microtesla MRI can become an efficient tool for in vivo imaging of hyperpolarized carbon-13, produced by low-temperature dissolution DNP.


IEEE Transactions on Applied Superconductivity | 2009

SQUID-Based Microtesla MRI for In Vivo Relaxometry of the Human Brain

Vadim S. Zotev; Igor Savukov; Tuba Owens; Petr L. Volegov; John J. Gomez; Michelle A. Espy

SQUID-based MRI (magnetic resonance imaging) at microtesla fields has developed significantly over the past few years. Here we describe application of this method for magnetic relaxation measurements in the living human brain. We report values of the longitudinal relaxation time T1 for brain tissues, measured in vivo for the first time at microtesla fields. The experiments were performed at 46 muT field using a seven-channel SQUID system designed for microtesla MRI and MEG. Values of T1, measured for different tissues at this field, are found to be close (within 5%) to the corresponding values of the transverse relaxation time T2 at the same field. Implications of this result for imaging contrast in microtesla MRI are discussed.


IEEE Transactions on Applied Superconductivity | 2011

SQUIDs vs. Induction Coils for Ultra-Low Field Nuclear Magnetic Resonance: Experimental and Simulation Comparison

Larry J. Schultz; Michelle A. Espy; Robert H. Kraus; Igor Savukov; Petr L. Volegov; Caroline Wurden

Nuclear magnetic resonance (NMR) is widely used in medicine, chemistry and industry. One application area is magnetic resonance imaging (MRI). Recently it has become possible to perform NMR and MRI in the ultra-low field (ULF) regime requiring measurement field strengths of the order of only 1 Gauss. This technique exploits the advantages offered by superconducting quantum interference devices or SQUIDs. Our group has built SQUID based MRI systems for brain imaging and for liquid explosives detection at airport security checkpoints. The requirement for liquid helium cooling limits potential applications of ULF MRI for liquid identification and security purposes. Our experimental comparative investigation shows that room temperature inductive magnetometers may provide enough sensitivity in the 3-10 kHz range and can be used for fast liquid explosives detection based on ULF NMR technique. We describe experimental and computer-simulation results comparing multichannel SQUID based and induction coils based instruments that are capable of performing ULF MRI for liquid identification.


IEEE Transactions on Applied Superconductivity | 2009

Applications of Ultra-Low Field Magnetic Resonance for Imaging and Materials Studies

Michelle A. Espy; Mark Flynn; John J. Gomez; Christina J. Hanson; Robert H. Kraus; Per E. Magnelind; Karlene Maskaly; Shaun Newman; Mark Peters; Henrik Sandin; Igor Savukov; Larry J. Schultz; Algis Urbaitis; Petr L. Volegov; Vadim S. Zotev

Recently it has become both possible and practical to perform MR at magnetic fields from muT to mT, the so-called ultra-low field (ULF) regime. SQUID sensor technology allows for ultra-sensitive detection while pulsed pre-polarizing fields greatly enhance signal. The instrumentation allows for unprecedented flexibility in signal acquisition sequences. Here we present the results from several applications of ULF MR which exploit the unique abilities of the method. These include novel ways to image both brain structure and function either by combination of MRI with magnetoencephalography or direct observation of the interaction of neural currents with the spin population, and ULF relaxometry for detection and characterization of materials relevant to numerous non-invasive inspection applications. We briefly describe the motivation, advantages, and recent results of several new applications of the ULF MR method. Specifically, we present recent data measuring the interaction of weak ( ~ 10 muA) currents with a spin-population in a water phantom, as studied by ULF MRI with implications for neural current imaging. We also present data from a ULF MR relaxometer developed inspecting liquids in a check-point for the presence of hazardous material.


IEEE Transactions on Applied Superconductivity | 2011

Progress on Detection of Liquid Explosives Using Ultra-Low Field MRI

Michelle A. Espy; Shermiyah Baguisa; David Dunkerley; Per E. Magnelind; Tuba Owens; Henrik Sandin; Igor Savukov; Larry J. Schultz; Algis Urbaitis; Petr L. Volegov

Nuclear magnetic resonance (NMR) spectroscopy and magnetic resonance imaging (MRI) methods are widely used in medicine, chemistry and industry. Over the past several years there has been increasing interest in performing NMR and MRI in the ultra-low field (ULF) regime, with measurement field strengths of 10-100 microTesla and pre-polarization fields of 30-50 mTesla. The real-time signal-to-noise ratio for such measurements is about 100. Our group at LANL has built and demonstrated the performance of SQUID-based ULF NMR/MRI instrumentation for classification of materials and detection of liquid explosives via their relaxation properties measured at ULF, using T1, T2, and T1 frequency dispersion. We are also beginning to investigate the performance of induction coils as sensors. Here we present recent progress on the applications of ULF MR to the detection of liquid explosives, in imaging and relaxometry.


Journal of Magnetic Resonance | 2013

Anatomical MRI with an atomic magnetometer

Igor Savukov; Todor Karaulanov

Ultra-low field (ULF) MRI is a promising method for inexpensive medical imaging with various additional advantages over conventional instruments such as low weight, low power, portability, absence of artifacts from metals, and high contrast. Anatomical ULF MRI has been successfully implemented with SQUIDs, but SQUIDs have the drawback of a cryogen requirement. Atomic magnetometers have sensitivity comparable to SQUIDs and can be in principle used for ULF MRI to replace SQUIDs. Unfortunately some problems exist due to the sensitivity of atomic magnetometers to a magnetic field and gradients. At low frequency, noise is also substantial and a shielded room is needed for improving sensitivity. In this paper, we show that at 85 kHz, the atomic magnetometer can be used to obtain anatomical images. This is the first demonstration of any use of atomic magnetometers for anatomical MRI. The demonstrated resolution is 1.1 mm×1.4 mm in about 6 min of acquisition with SNR of 10. Some applications of the method are discussed. We discuss several measures to increase the sensitivity to reach a resolution 1 mm×1 mm.

Collaboration


Dive into the Igor Savukov's collaboration.

Top Co-Authors

Avatar

Michelle A. Espy

Los Alamos National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Petr L. Volegov

Los Alamos National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Henrik Sandin

Los Alamos National Laboratory

View shared research outputs
Top Co-Authors

Avatar

John J. Gomez

Los Alamos National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Larry J. Schultz

Los Alamos National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Robert H. Kraus

Los Alamos National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Vadim S. Zotev

Los Alamos National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Young-Jin Kim

Seoul National University

View shared research outputs
Top Co-Authors

Avatar

Todor Karaulanov

Los Alamos National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Tuba Owens

Los Alamos National Laboratory

View shared research outputs
Researchain Logo
Decentralizing Knowledge