Todor Karaulanov
Los Alamos National Laboratory
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Todor Karaulanov.
Journal of Magnetic Resonance | 2013
Igor Savukov; Todor Karaulanov
Ultra-low field (ULF) MRI is a promising method for inexpensive medical imaging with various additional advantages over conventional instruments such as low weight, low power, portability, absence of artifacts from metals, and high contrast. Anatomical ULF MRI has been successfully implemented with SQUIDs, but SQUIDs have the drawback of a cryogen requirement. Atomic magnetometers have sensitivity comparable to SQUIDs and can be in principle used for ULF MRI to replace SQUIDs. Unfortunately some problems exist due to the sensitivity of atomic magnetometers to a magnetic field and gradients. At low frequency, noise is also substantial and a shielded room is needed for improving sensitivity. In this paper, we show that at 85 kHz, the atomic magnetometer can be used to obtain anatomical images. This is the first demonstration of any use of atomic magnetometers for anatomical MRI. The demonstrated resolution is 1.1 mm×1.4 mm in about 6 min of acquisition with SNR of 10. Some applications of the method are discussed. We discuss several measures to increase the sensitivity to reach a resolution 1 mm×1 mm.
Journal of Magnetic Resonance | 2013
Igor Savukov; Hsueh-Ying Chen; Todor Karaulanov; Christian Hilty
The nuclear-spin optical rotation (NSOR) effect recently attracted much attention due to potential applications in combined optical-NMR spectroscopy and imaging. Currently, the main problem with applications of NSOR is low SNR and accuracy of measurements. In this work we demonstrate a new method for data acquisition and analysis based on a low-power laser and an emphasis on software based processing. This method significantly reduces cost and is suitable for application in most NMR spectroscopy laboratories for exploration of the NSOR effect. Despite the use of low laser power, SNR can be substantially improved with fairly simple strategies including the use of short wavelength and a multi-pass optical cell with in-flow pre-polarization in a 7 T magnet. Under these conditions, we observed that NSOR signal can be detected in less than 1 min and discuss strategies for further improvement of signal. With higher SNR than previously reported, NSOR constants can be extracted with improved accuracy. On the example of water, we obtained measurements at a level of accuracy of 5%. We include a detailed theoretical analysis of the geometrical factors of the experiment, which is required for accurate quantification of NSOR. This discussion is particularly important for relatively short detection cells, which will be necessary to use in spectroscopy or imaging applications that impose geometrical constraints.
Journal of Magnetic Resonance | 2011
Igor Savukov; Todor Karaulanov; A. Castro; Petr L. Volegov; A. Urbatis; John J. Gomez; Michelle A. Espy
Ultra-low field (ULF) MRI with a pulsed prepolarization is a promising method with potential for applications where conventional high-, mid-, and low-field medical MRI cannot be used due to cost, weight, or other restrictions. Previously, successful ULF demonstrations of anatomical imaging were made using liquid helium-cooled SQUIDs and conducted inside a magnetically shielded room. The Larmor frequency for these demonstrations was ∼3 kHz. In order to make ULF MRI more accessible, portable, and inexpensive, we have recently developed a non-cryogenic system. To eliminate the requirement for a magnetically shielded room and improve the detection sensitivity, we increased the frequency to 83.6 kHz. While the background noise at these frequencies is greatly reduced, this is still within the ULF regime and most of its advantages such as simplicity in magnetic field generation hardware, and less stringent requirements for uniform fields, remaining. In this paper we demonstrate use of this system to image a human hand with up to 1.5mm resolution. The signal-to-noise ratio was sufficient to reveal anatomical features within a scan time of less than 7 min. This prototype can be scaled up for constructing head and full body scanners, and work is in progress toward demonstration of head imaging.
Measurement Science and Technology | 2016
Todor Karaulanov; Igor Savukov; Young-Jin Kim
We constructed a spin-exchange relaxation-free (SERF) magnetometer with a small angle between the pump and probe beams facilitating a multi-channel design with a flat pancake cell. This configuration provides almost complete overlap of the beams in the cell, and prevents the pump beam from entering the probe detection channel. By coupling the lasers in multi-mode fibers, without an optical isolator or field modulation, we demonstrate a sensitivity of 10 fT
Biomedizinische Technik | 2015
Leyma P. De Haro; Todor Karaulanov; Erika C. Vreeland; Bill Anderson; Helen J. Hathaway; Dale L. Huber; Christopher Nettles; Andrew D. Price; Todd C. Monson; Edward R. Flynn
Journal of Magnetic Resonance | 2013
Igor Savukov; Todor Karaulanov; Caroline Wurden; Larry J. Schultz
/\sqrt{\text{Hz}}
Journal of Magnetic Resonance | 2014
Igor Savukov; Todor Karaulanov
Solid State Nuclear Magnetic Resonance | 2014
Y.J. Kim; Todor Karaulanov; Shaun Newman; Algis Urbaitis; Petr L. Volegov; Jacob Yoder; Michelle A. Espy
for frequencies between 10 Hz and 100 Hz. In addition to the experimental study of sensitivity, we present a theoretical analysis of SERF magnetometer response to magnetic fields for small-angle and parallel-beam configurations, and show that at optimal DC offset fields the magnetometer response is comparable to that in the orthogonal-beam configuration. Based on the analysis, we also derive fundamental and probe-limited sensitivities for the arbitrary non-orthogonal geometry. The expected practical and fundamental sensitivities are of the same order as those in the orthogonal geometry. As a result, we anticipate that our design will be useful for magnetoencephalography (MEG) and magnetocardiography (MCG) applications.
Physics in Medicine and Biology | 2017
Mingxiong Huang; Bill Anderson; Charles W. Huang; Gerd J. Kunde; Erika C. Vreeland; Jeffrey W. Huang; Todor Karaulanov; Christopher Nettles; Andrew Gomez; Kayla E. Minser; Caroline L. Weldon; Giulio Paciotti; Michael Harsh; Roland R. Lee; Edward R. Flynn
Abstract Background: Here we describe superparamagnetic relaxometry (SPMR), a technology that utilizes highly sensitive magnetic sensors and superparamagnetic nanoparticles for cancer detection. Using SPMR, we sensitively and specifically detect nanoparticles conjugated to biomarkers for various types of cancer. SPMR offers high contrast in vivo, as there is no superparamagnetic background, and bones and tissue are transparent to the magnetic fields. Methods: In SPMR measurements, a brief magnetizing pulse is used to align superparamagnetic nanoparticles of a discrete size. Following the pulse, an array of superconducting quantum interference detectors (SQUID) sensors detect the decaying magnetization field. NP size is chosen so that, when bound, the induced field decays in seconds. They are functionalized with specific biomarkers and incubated with cancer cells in vitro to determine specificity and cell binding. For in vivo experiments, functionalized NPs are injected into mice with xenograft tumors, and field maps are generated to localize tumor sites. Results: Superparamagnetic NPs developed here have small size dispersion. Cell incubation studies measure specificity for different cell lines and antibodies with very high contrast. In vivo animal measurements verify SPMR localization of tumors. Our results indicate that SPMR possesses sensitivity more than 2 orders of magnitude better than previously reported.
Cancer Research | 2017
Erika C. Vreeland; Kayla E. Minser; Caroline L. Weldon; Andrew Gomez; Todor Karaulanov; Helen J. Hathaway; William H. Anderson; Christopher Nettles; Dale L. Huber; Giulio F. Paciotti
Ultra-low field (ULF) MRI as an alternative to high field MRI can find some niche applications where high field is a liability. Previously we demonstrated hand images with a non-cryogenic ULF MRI system, but such a system was restrictive to the size of the imaging objects. We have modified the previous setup to increase the imaging volume and demonstrate the image of human hand near the wrist area. One goal for the demonstration is the evaluation of quality of larger bone structure to project image quality to other parts of extremities, such as elbows, shoulders, and knees. We found that after 12 min of acquisition, the image quality was quite satisfactory. To achieve this image quality, several problems were solved that appeared in the new system. The increase in the imaging volume size led to an increase in transient time and various measures were taken to reduce this time. We also explored a method of overcoming the artifacts and image quality reduction arising from field drifts present in the system due to heating of the coils. We believe that our results can be useful for evaluation of diagnostic capability of non-cryogenic ULF MRI of extremities and other parts of the body. The system can be also applied to image animals and tissues.