Featured researches published by Ingemar Fredriksson.


Microvascular Research | 2009

Measurement depth and volume in laser Doppler flowmetry

Ingemar Fredriksson; Marcus Larsson; Tomas Strömberg

A new method for estimating the measurement depth and volume in laser Doppler flowmetry (LDF) is presented. The method is based on Monte Carlo simulations of light propagation in tissue. The contribution from each individual Doppler shift is calculated and thereby multiple Doppler shifts are handled correctly. Different LDF setups for both probe based (0.0, 0.25, 0.5, and 1.2 mm source-detector separation) and imaging systems (0.5 and 2.0 mm beam diameter) are considered, at the wavelengths 543 nm, 633 nm, and 780 nm. Non-linear speckle pattern effects are accounted for in the imaging system setups. The effects of tissue optical properties, blood concentration, and blood oxygen saturation are evaluated using both homogeneous tissue models and a layered skin model. The results show that the effect on the measurement depth of changing tissue properties is comparable to the effect of changing the system setup, e.g. source-detector separation and wavelength. Skin pigmentation was found to have a negligible effect on the measurement depth. Examples of measurement depths are (values are given for a probe based system with 0.25 mm source-detector separation and an imaging system with a 0.5 mm beam diameter, respectively, both operating at 780 nm): muscle - 0.55/0.79 mm; liver - 0.40/0.53 mm; gray matter - 0.48/0.68 mm; white matter - 0.20/0.20 mm; index finger pulp - 0.41/0.53 mm; forearm skin - 0.53/0.56 mm; heat provoked forearm skin - 0.66/0.67 mm.


Journal of Biomedical Optics | 2008

Optical microcirculatory skin model: assessed by Monte Carlo simulations paired with in vivo laser Doppler flowmetry

Ingemar Fredriksson; Marcus Larsson; Tomas Strömberg

An optical microvascular skin model, valid at 780 nm, was developed. The model consisted of six layers with individual optical properties and variable thicknesses and blood concentrations at three different blood flow velocities. Monte Carlo simulations were used to evaluate the impact of various model parameters on the traditional laser Doppler flowmetry (LDF) measures. A set of reference Doppler power spectra was generated by simulating 7000 configurations, varying the thickness and blood concentrations. Simulated spectra, at two different source detector separations, were compared with in vivo recorded spectra, using a nonlinear search algorithm for minimizing the deviation between simulated and measured spectra. The model was validated by inspecting the thickness and blood concentrations that generated the best fit. These four parameters followed a priori expectations for the measurement situations, and the simulated spectra agreed well with the measured spectra for both detector separations. Average estimated dermal blood concentration was 0.08% at rest and 0.63% during heat provocation (44 degrees C) on the volar side of the forearm and 1.2% at rest on the finger pulp. The model is crucial for developing a technique for velocity-resolved absolute LDF measurements with known sampling volume and can also be useful for other bio-optical modalities.


Diabetes | 2010

Reduced arteriovenous shunting capacity after local heating and redistribution of baseline skin blood flow in type 2 diabetes assessed with velocity-resolved quantitative laser Doppler flowmetry.

Ingemar Fredriksson; Marcus Larsson; Fredrik Nyström; Toste Länne; Carl Johan Östgren; Tomas Strömberg

OBJECTIVE To compare the microcirculatory velocity distribution in type 2 diabetic patients and nondiabetic control subjects at baseline and after local heating. RESEARCH DESIGN AND METHODS The skin blood flow response to local heating (44°C for 20 min) was assessed in 28 diabetic patients and 29 control subjects using a new velocity-resolved quantitative laser Doppler flowmetry technique (qLDF). The qLDF estimates erythrocyte (RBC) perfusion (velocity × concentration), in a physiologically relevant unit (grams RBC per 100 g tissue × millimeters per second) in a fixed output volume, separated into three velocity regions: v <1 mm/s, v 1–10 mm/s, and v >10 mm/s. RESULTS The increased blood flow occurs in vessels with a velocity >1 mm/s. A significantly lower response in qLDF total perfusion was found in diabetic patients than in control subjects after heat provocation because of less high-velocity blood flow (v >10 mm/s). The RBC concentration in diabetic patients increased sevenfold for v between 1 and 10 mm/s, and 15-fold for v >10 mm/s, whereas no significant increase was found for v <1 mm/s. The mean velocity increased from 0.94 to 7.3 mm/s in diabetic patients and from 0.83 to 9.7 mm/s in control subjects. CONCLUSIONS The perfusion increase occurs in larger shunting vessels and not as an increase in capillary flow. Baseline diabetic patient data indicated a redistribution of flow to higher velocity regions, associated with longer duration of diabetes. A lower perfusion was associated with a higher BMI and a lower toe-to-brachial systolic blood pressure ratio.


Journal of Biomedical Optics | 2012

Inverse Monte Carlo method in a multilayered tissue model for diffuse reflectance spectroscopy

Ingemar Fredriksson; Marcus Larsson; Tomas Strömberg

Model based data analysis of diffuse reflectance spectroscopy data enables the estimation of optical and structural tissue parameters. The aim of this study was to present an inverse Monte Carlo method based on spectra from two source-detector distances (0.4 and 1.2 mm), using a multilayered tissue model. The tissue model variables include geometrical properties, light scattering properties, tissue chromophores such as melanin and hemoglobin, oxygen saturation and average vessel diameter. The method utilizes a small set of presimulated Monte Carlo data for combinations of different levels of epidermal thickness and tissue scattering. The path length distributions in the different layers are stored and the effect of the other parameters is added in the post-processing. The accuracy of the method was evaluated using Monte Carlo simulations of tissue-like models containing discrete blood vessels, evaluating blood tissue fraction and oxygenation. It was also compared to a homogeneous model. The multilayer model performed better than the homogeneous model and all tissue parameters significantly improved spectral fitting. Recorded in vivo spectra were fitted well at both distances, which we previously found was not possible with a homogeneous model. No absolute intensity calibration is needed and the algorithm is fast enough for real-time processing.


Journal of Biomedical Optics | 2010

Model-based quantitative laser Doppler flowmetry in skin

Ingemar Fredriksson; Marcus Larsson; Tomas Strömberg

Laser Doppler flowmetry (LDF) can be used for assessing the microcirculatory perfusion. However, conventional LDF (cLDF) gives only a relative perfusion estimate for an unknown measurement volume, with no information about the blood flow speed distribution. To overcome these limitations, a model-based analysis method for quantitative LDF (qLDF) is proposed. The method uses inverse Monte Carlo technique with an adaptive three-layer skin model. By analyzing the optimal model where measured and simulated LDF spectra detected at two different source-detector separations match, the absolute microcirculatory perfusion for a specified speed region in a predefined volume is determined. qLDF displayed errors<12% when evaluated using simulations of physiologically relevant variations in the layer structure, in the optical properties of static tissue, and in blood absorption. Inhomogeneous models containing small blood vessels, hair, and sweat glands displayed errors<5%. Evaluation models containing single larger blood vessels displayed significant errors but could be dismissed by residual analysis. In vivo measurements using local heat provocation displayed a higher perfusion increase with qLDF than cLDF, due to nonlinear effects in the latter. The qLDF showed that the perfusion increase occurred due to an increased amount of red blood cells with a speed>1 mm∕s.


Optics Express | 2009

Spectral determination of a two-parametric phase function for polydispersive scattering liquids

Tobias Lindbergh; Ingemar Fredriksson; Marcus Larsson; Tomas Strömberg

A method for determining a two-parametric Gegenbauer-kernel phase function that accurately describes the diffuse reflectance from a polydispersive scattering media at small source-detector separations (0.23 to 1.2 mm), is presented. The method involves spectral collimated transmission measurements, spatially resolved spectral diffuse reflectance (SRDR) measurements, and inverse Monte Carlo technique. Both absolute calibration (using a monodispersive polystyrene microsphere suspension) and relative calibration (eliminating differences between fibers) of SRDR spectra yielded comparable results. When applied to water dilutions of milk, simulated and measured spectra deviated less than 6.5% and 2.5% for the absolute and relative calibration case, respectively, even for the closest fiber separation. Corresponding values for milk including ink as an absorber, were 13.4% and 7.3%.


Journal of Biomedical Optics | 2013

Inverse Monte Carlo in a multilayered tissue model: merging diffuse reflectance spectroscopy and laser Doppler flowmetry.

Ingemar Fredriksson; Oleg Burdakov; Marcus Larsson; Tomas Strömberg

Abstract. The tissue fraction of red blood cells (RBCs) and their oxygenation and speed-resolved perfusion are estimated in absolute units by combining diffuse reflectance spectroscopy (DRS) and laser Doppler flowmetry (LDF). The DRS spectra (450 to 850 nm) are assessed at two source–detector separations (0.4 and 1.2 mm), allowing for a relative calibration routine, whereas LDF spectra are assessed at 1.2 mm in the same fiber-optic probe. Data are analyzed using nonlinear optimization in an inverse Monte Carlo technique by applying an adaptive multilayered tissue model based on geometrical, scattering, and absorbing properties, as well as RBC flow-speed information. Simulations of 250 tissue-like models including up to 2000 individual blood vessels were used to evaluate the method. The absolute root mean square (RMS) deviation between estimated and true oxygenation was 4.1 percentage units, whereas the relative RMS deviations for the RBC tissue fraction and perfusion were 19% and 23%, respectively. Examples of in vivo measurements on forearm and foot during common provocations are presented. The method offers several advantages such as simultaneous quantification of RBC tissue fraction and oxygenation and perfusion from the same, predictable, sampling volume. The perfusion estimate is speed resolved, absolute (% RBC×mm/s), and more accurate due to the combination with DRS.


Optics Express | 2012

Inverse Monte Carlo for estimation of scattering and absorption in liquid optical phantoms

Hanna Karlsson; Ingemar Fredriksson; Marcus Larsson; Tomas Strömberg

A spectroscopic probe with multiple detecting fibers was used for quantifying absorption and scattering in liquid optical phantoms. The phantoms were mixtures of Intralipid and red and blue food dyes. Intensity calibration for the detecting fibers was undertaken using either a microsphere suspension (absolute calibration) or a uniform detector illumination (relative calibration between detectors). Two different scattering phase functions were used in an inverse Monte Carlo algorithm. Data were evaluated for residual spectra (systematic deviations and magnitude) and accuracy in estimation of scattering and absorption. Spectral fitting was improved by allowing for a 10% intensity relaxation in the optimization algorithm. For a multi-detector setup, non-systematic residual spectrum was only found using the more complex Gegenbauer-kernel phase function. However, the choice of phase function did not influence the accuracy in the estimation of absorption and scattering. Similar estimation accuracy as in the multi-detector setup was also obtained using either two relative calibrated detectors or one absolute calibrated detector at a fiber separation of 0.46 mm.


Biomedical optics | 2006

Absolute flow velocity components in laser Doppler flowmetry

Ingemar Fredriksson; Marcus Larsson; Tomas Strömberg

A method to separate a Doppler power spectrum into a number of flow velocity components, measured in absolute units (mm/s), is presented. A Monte Carlo software was developed to track each individual Doppler shift, to determine the probability, p(n), for a photon to undergo n Doppler shifts. Given this shift distribution, a mathematical relationship was developed and used to calculate a Doppler power spectrum originating from a certain combination of velocity components. The non linear Levenberg-Marquardt optimization method could thus be used to fit the calculated and measured Doppler power spectra, giving the true set of velocity components in the measured sample. The method was evaluated using a multi tube flow phantom perfused with either polystyrene microspheres or undiluted/diluted human blood (hct = 0.45). It estimated the velocity components in the flow phantom well, during both low and high concentrations of moving scatterers (microspheres or blood). Thus, further development of the method could prove to be a valuable clinical tool to differentiate capillary blood flow.


Microvascular Research | 2015

Oxygen saturation, red blood cell tissue fraction and speed resolved perfusion - A new optical method for microcirculatory assessment.

Hanna Jonasson; Ingemar Fredriksson; Anders Pettersson; Marcus Larsson; Tomas Strömberg

We have developed a new fiber-optic system that combines diffuse reflectance spectroscopy (DRS) and laser Doppler Flowmetry (LDF) for a multi-modal assessment of the microcirculation. Quantitative data is achieved with an inverse Monte Carlo algorithm based on an individually adaptive skin model. The output parameters are calculated from the model and given in absolute units: hemoglobin oxygen saturation (%), red blood cell (RBC) tissue fraction (%), and the speed resolved RBC perfusion separated into three speed regions; 0-1mm/s, 1-10mm/s and above 10mm/s (% mm/s). The aim was to explore microcirculatory parameters using the new optical method, integrating DRS and LDF in a joint skin model, during local heating of the dorsal foot and venous and arterial occlusion of the forearm in 23 healthy subjects (age 20-28years). There were differences in the three speed regions in regard to blood flow changes due to local heating, where perfusion for high speeds increased the most. There was also a high correlation between changes in oxygenation and changes in perfusion for higher speeds. Oxygen saturation at baseline was 44% on foot, increasing to 83% at plateau after heating. The larger increase in perfusion for higher speeds than for lower speeds together with the oxygenation increase during thermal provocation, shows a local thermoregulatory blood flow in presumably arteriolar dermal vessels. In conclusion, there are improved possibilities to assess microcirculation using integrated DRS and LDF in a joint skin model by enabling both oxygenation and speed resolved blood flow assessment simultaneously and in the same skin site. Output parameters in absolute units may also yield new insights about the microcirculatory system.

Collaboration


Dive into the Ingemar Fredriksson's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge