Journal of Neural Engineering | 2006

The effect of cystic cavities on deep brain stimulation in the basal ganglia: a simulation-based study

Mattias Åström; Johannes Johansson; Marwan Hariz; Ola Eriksson; Karin Wårdell

Although the therapeutic effect of deep brain stimulation (DBS) is well recognized, a fundamental understanding of the mechanisms responsible is still not known. In this study finite element method (FEM) modelling and simulation was used in order to study relative changes of the electrical field extension surrounding a monopolar DBS electrode positioned in grey matter. Due to the frequently appearing cystic cavities in the DBS-target globus pallidus internus, a nucleus of grey matter with and without a cerebrospinal fluid filled cystic cavity was modelled. The position, size and shape of the cyst were altered in relation to the electrode. The simulations demonstrated an electrical field around the active element with decreasing values in the radial direction. A stepwise change was present at the edge between grey and white matters. The cyst increased the radial extension and changed the shape of the electrical field substantially. The position, size and shape of the cyst were the main influencing factors. We suggest that cystic cavities in the DBS-target may result in closely related unexpected structures or neural fibre bundles being stimulated and could be one of the reasons for suboptimal clinical effects or stimulation-induced side effects.


Journal of Biomedical Optics | 2010

Spectroscopic method for determination of the absorption coefficient in brain tissue

Johannes Johansson

I use Monte Carlo simulations and phantom measurements to characterize a probe with adjacent optical fibres for diffuse reflectance spectroscopy during stereotactic surgery in the brain. Simulations and measurements have been fitted to a modified Beer-Lambert model for light transport in order to be able to quantify chromophore content based on clinically measured spectra in brain tissue. It was found that it is important to take the impact of the light absorption into account when calculating the apparent optical path length, lp, for the photons in order to get good estimates of the absorption coefficient, μa. The optical path length was found to be well fitted to the equation lp=a+b ln(Is)+c ln(μa)+d ln(Is)ln(μa), where Is is the reflected light intensity for scattering alone (i.e., zero absorption). Although coefficients a-d calculated in this study are specific to the probe used here, the general form of the equation should be applicable to similar probes.


Stereotactic and Functional Neurosurgery | 2009

Combined Diffuse Light Reflectance and Electrical Impedance Measurements as a Navigation Aid in Deep Brain Surgery

Johannes Johansson; Patric Blomstedt; Neda Haj-Hosseini; A. Tommy Bergenheim; Ola Eriksson; Karin Wårdell

Aim: The aim of this study is to assess reflected light intensity combined with impedance as a navigation aid during stereotactic neurosurgery. Methods: During creation of 21 trajectories for stereotactic implantation of deep brain stimulation electrodes in the globus pallidus internus or subthalamus (zona incerta or subthalamic nucleus), impedance at 512 kHz and reflected light intensity at 780 nm were measured continuously and simultaneously with a radio frequency electrode containing optical fibres. The signals were compared with the anatomy, determined from pre- and post-operative MRI and CT. The measurements were performed within minutes, and signal analysis was done post-operatively. Results: Reflected light intensity was low from the cortex, lateral ventricle, caudate nucleus and putamen; intermediate from the globus pallidus and thalamus; while it was high from the subcortical white matter, internal capsule and subthalamus. The electrical impedance was less consistent, but generally low in the cortex, intermediate in the subcortical white matter, putamen, globus pallidus and thalamus, and high in the internal capsule and subthalamus. Conclusion: Reflected light intensity and electrical impedance give complementary information about passed tissue, and the combination seems promising as a navigation aid during stereotactic neurosurgery.


Biomedical Optics Express | 2015

Non-contact scanning diffuse correlation tomography system for three-dimensional blood flow imaging in a murine bone graft model.

Songfeng Han; Johannes Johansson; Miguel Mireles; Ashley R. Proctor; Michael D. Hoffman; Joseph B. Vella; Danielle S. W. Benoit; Turgut Durduran; Regine Choe

A non-contact galvanometer-based optical scanning system for diffuse correlation tomography was developed for monitoring bone graft healing in a murine femur model. A linear image reconstruction algorithm for diffuse correlation tomography was tested using finite-element method based simulated data and experimental data from a femur or a tube suspended in a homogeneous liquid phantom. Finally, the non-contact system was utilized to monitor in vivo blood flow changes prior to and one week after bone graft transplantation within murine femurs. Localized blood flow changes were observed in three mice, demonstrating a potential for quantification of longitudinal blood flow associated with bone graft healing.


Journal of Biomedical Optics | 2009

Simulation of reflected light intensity changes during navigation and radio frequency lesioning in the brain

Johannes Johansson; Ingemar Fredriksson; Karin Wårdell; Ola Eriksson

An electrode with adjacent optical fibers for measurements during navigation and radio frequency lesioning in the brain is modeled for Monte Carlo simulations of light transport in brain tissue. Relative reflected light intensity at 780 nm, I780, from this electrode and probes with identical fiber configuration are simulated using the intensity from native white matter as reference. Models are made of homogeneous native and coagulated gray, thalamus, and white matter as well as blood. Dual layer models, including models with a layer of cerebrospinal fluid between the fibers and the brain tissue, are also made. Simulated I780 was 0.16 for gray matter, 0.67 for coagulate gray matter, 0.36 for thalamus, 0.39 for coagulated thalamus, unity for white matter, 0.70 for coagulated white matter, and 0.24 for blood. Thalamic matter is also found to reflect more light than gray matter and less than white matter in clinical studies. In conclusion, the reflected light intensity can be used to differentiate between gray and white matter during navigation. Furthermore, coagulation of light gray tissue, such as the thalamus, might be difficult to detect using I780, but coagulation in darker gray tissue should result in a rapid increase of I780.


Journal of Biophotonics | 2013

Intracerebral quantitative chromophore estimation from reflectance spectra captured during deep brain stimulation implantation

Johannes Johansson; Karin Wårdell

Quantification of blood fraction (f(blood)), blood oxygenation (S(O2)), melanin, lipofuscin and oxidised and reduced Cytochrome aa 3 and c was done from diffuse reflectance spectra captured in cortex, white matter, globus pallidus internus (GPi) and subthalamus during stereotactic implantations of 29 deep brain stimulation (DBS) electrodes with the aim of investigating whether the chromophores can give physiological information about the targets for DBS. Double-sided Mann-Whitney U-tests showed more lipofuscin in GPi compared to white matter and subthalamus (p < 0.05). Compared to the other structures, f(blood) was significantly higher in cortex (p < 0.05) and S(O2) lower in GPi (p < 0.05). Median values and range for f(blood) were 1.0 [0.2-6.0]% in the cortex, 0.3 [0.1-8.2]% in white matter, 0.2 [0.1-0.8]% in the GPi and 0.2 [0.1-11.7]% in the subthalamus. Corresponding values for S(O2) was 20 [0-81]% in the cortex, 29 [0-78]% in white matter, 0 [0-0]% in the GPi and 0 [0-92]% in the subthalamus. In conclusion, the measurements indicate very low oxygenation and blood volume for DBS patients, especially in the GPi. It would be of great interest to investigate whether this is due to the disease, the normal situation or an artefact of doing invasive measurements.


Biomedical Optics Express | 2016

Scanning, non-contact, hybrid broadband diffuse optical spectroscopy and diffuse correlation spectroscopy system.

Johannes Johansson; Miguel Mireles; Jordi Morales-Dalmau; Parisa Farzam; Mar Martínez-Lozano; Oriol Casanovas; Turgut Durduran

A scanning system for small animal imaging using non-contact, hybrid broadband diffuse optical spectroscopy (ncDOS) and diffuse correlation spectroscopy (ncDCS) is presented. The ncDOS uses a two-dimensional spectrophotometer retrieving broadband (610-900 nm) spectral information from up to fifty-seven source-detector distances between 2 and 5 mm. The ncDCS data is simultaneously acquired from four source-detector pairs. The sample is scanned in two dimensions while tracking variations in height. The system has been validated with liquid phantoms, demonstrated in vivo on a human fingertip during an arm cuff occlusion and on a group of mice with xenoimplanted renal cell carcinoma.


PLOS ONE | 2016

Diffuse Optical Characterization of the Healthy Human Thyroid Tissue and Two Pathological Case Studies

Claus Lindner; Mireia Mora; Parisa Farzam; Mattia Squarcia; Johannes Johansson; Udo M. Weigel; Irene Halperin; Felicia Hanzu; Turgut Durduran

The in vivo optical and hemodynamic properties of the healthy (n = 22) and pathological (n = 2) human thyroid tissue were measured non-invasively using a custom time-resolved spectroscopy (TRS) and diffuse correlation spectroscopy (DCS) system. Medical ultrasound was used to guide the placement of the hand-held hybrid optical probe. TRS measured the absorption and reduced scattering coefficients (μa, μs′) at three wavelengths (690, 785 and 830 nm) to derive total hemoglobin concentration (THC) and oxygen saturation (StO2). DCS measured the microvascular blood flow index (BFI). Their dependencies on physiological and clinical parameters and positions along the thyroid were investigated and compared to the surrounding sternocleidomastoid muscle. The THC in the thyroid ranged from 131.9 μM to 144.8 μM, showing a 25–44% increase compared to the surrounding sternocleidomastoid muscle tissue. The blood flow was significantly higher in the thyroid (BFIthyroid = 16.0 × 10-9 cm2/s) compared to the muscle (BFImuscle = 7.8 × 10-9 cm2/s), while StO2 showed a small (StO2, muscle = 63.8% to StO2, thyroid = 68.4%), yet significant difference. Two case studies with thyroid nodules underwent the same measurement protocol prior to thyroidectomy. Their THC and BFI reached values around 226.5 μM and 62.8 × 10-9 cm2/s respectively showing a clear contrast to the nodule-free thyroid tissue as well as the general population. The initial characterization of the healthy and pathologic human thyroid tissue lays the ground work for the future investigation on the use of diffuse optics in thyroid cancer screening.


international conference of the ieee engineering in medicine and biology society | 2004

Comparison between a detailed and a simplified finite element model of radio-frequency lesioning in the brain

Johannes Johansson; Joakim Wren; Dan Loyd; Karin Wårdell

A detailed and a simplified model of a lesioning electrode was made using the finite element method. 15 simulations of the lesioning procedure were performed for each model and the resulting lesion volumes were compared in order to investigate if the simplified model is adequate. The simplified model resulted in a very slight overestimation of the volume compared to the detailed model. It was thus concluded that the simplified model is adequate for simulations.


Stereotactic and Functional Neurosurgery | 2017

Refining the Deep Brain Stimulation Target within the Limbic Globus Pallidus Internus for Tourette Syndrome

Ladan Akbarian-Tefaghi; Harith Akram; Johannes Johansson; Ludvic Zrinzo; Zinovia Kefalopoulou; Patricia Limousin; Eileen M. Joyce; Marwan Hariz; Karin Wårdell; Thomas Foltynie

Background: Deep brain stimulation (DBS) in patients with severe, refractory Tourette syndrome (TS) has demonstrated promising but variable results thus far. The thalamus and anteromedial globus pallidus internus (amGPi) have been the most commonly stimulated sites within the cortico-striato thalamic circuit, but an optimal target is yet to be elucidated. Objectives: This study of 15 patients with long-term amGPi DBS for severe TS investigated whether a specific anatomical site within the amGPi correlated with optimal clinical outcome for the measures of tics, obsessive compulsive behaviour (OCB), and mood. Methods: Validated clinical assessments were used to measure tics, OCB, quality of life, anxiety, and depression before DBS and at the latest follow-up (17-82 months). Electric field simulations were created for each patient using information on electrode location and individual stimulation parameters. A subsequent regression analysis correlated these patient-specific simulations to percentage changes in outcome measures in order to identify any significant voxels related to clinical improvement. Results: A region within the ventral limbic GPi, specifically on the medial medullary lamina in the pallidum at the level of the AC-PC, was significantly associated with improved tics but not mood or OCB outcome. Conclusions: This study adds further support to the application of DBS in a tic-related network, though factors such as patient sample size and clinical heterogeneity remain as limitations and replication is required.

Collaboration


Dive into the Johannes Johansson's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Dan Loyd

Linköping University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Parisa Farzam

ICFO – The Institute of Photonic Sciences

View shared research outputs
Top Co-Authors

Avatar

Turgut Durduran

ICFO – The Institute of Photonic Sciences

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge