Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where J. Duboscq is active.

Publication


Featured researches published by J. Duboscq.


nuclear science symposium and medical imaging conference | 1992

The fluid systems for the SLD Cherenkov Ring Imaging Detector

K. Abe; P. Antilogus; D. Aston; K.G. Baird; Andrew J. Bean; R. Ben-David; T. Bienz; F. Bird; D.O. Caldwell; M. Cavalli-Sforza; J.A. Coller; P. Coyle; D. G. Coyne; S. Dasu; S. Dolinsky; A.B. d'Oliveira; J. Duboscq; W. Dunwoodie; P. Gagnon; G.D. Hallewell; K. Hasegawa; Y. Hasegawa; J. Huber; Y. Iwasaki; P. Jacques; R. A. Johnson; M. Kalelkar; H. Kawahara; Y. Kwon; D. W. G. S. Leith

The design and operation of the fluid delivery, monitor, and control systems for the SLD barrel Cherenkov Ring Imaging Detector (CRID) are described. The systems deliver drift gas (C/sub 2/H/sub 6/+TMAE), radiator gas (C/sub 5/F/sub 12/+N/sub 2/), and radiator liquid (C/sub 6/F/sub 14/). Measured critical quantities such as electron lifetime in the drift gas and ultraviolet (UV) transparencies of the radiator fluids, together with the operational experience, are reported. >


ieee nuclear science symposium | 1990

Cherenkov Ring Imaging Detector front-end electronics

P. Antilogus; D. Aston; T. Bienz; F. Bird; S. Dasu; W. Dunwoodie; G.D. Hallewell; H. Kawahara; Y. Kwon; D. W. G. S. Leith; D. Marshall; D. R. Muller; T. Nagamine; G. Oxoby; B. N. Ratcliff; P.E. Rensing; D. Schultz; S. Shapiro; C. Simopoulos; E. Solodov; P. Stiles; F. Suekane; N. Toge; J. Va'vra; Sh Williams; R.J. Wilson; Js Whitaker; Andrew J. Bean; D.O. Caldwell; J. Duboscq

The front-end electronics of the Cerenkov Ring Imaging Detector (CRID) used in the Stanford Large Detector (SLD) spectrometer at the Stanford Linear Accelerator Center (SLAC) Linear Collider is described. The Plessey process provides a straightforward and low-cost path toward system miniaturization. System tests show good noise performance, calibration precision, system linearity, and signal shape uniformity over the full dynamic range. >


IEEE Transactions on Nuclear Science | 1990

Construction and testing of the SLD Cerenkov Ring Imaging Detector

M. Cavalli-Sforza; P. Coyle; D. Coyne; P. Gagnon; Dc Williams; P. Zucchelli; Js Whitaker; R.J. Wilson; A. Bean; D.O. Caldwell; J. Duboscq; J. Huber; A. Lu; L. Mathys; S. McHugh; R. J. Morrison; M. S. Witherell; S. Yellin; R. A. Johnson; J. Martinez; B. Meadows; M. Nussbaum; A.K.S. Santha; A. Shoup; I. Stockdale; P. Jacques; R.J. Plano; P. Stamer; P. Antilogus; D. Aston

The construction of the Cherenkov Ring Imaging Detector (CRID) for the SLD (Stanford Linear Collider Large Detector) experiment at the SLAC (Stanford Linear Accelerator Center) Linear Collider and the testing of its components is reported. Results are included from testing the drift boxes, liquid radiator trays, and mirrors for the barrel CRID. The development of the support systems essential for the operation of the CRID, namely, gas and liquid recirculation systems and monitoring, are discussed. >


Proceedings of the 26th International Conference on High Energy Physics | 1992

THE FIRST RESULTS FROM THE CRID DETECTOR AT SLD

J. Va’vra; K. Abe; P. Antilogus; D. Aston; K.G. Baird; Andrew J. Bean; R. Ben-David; T. Bienz; F. Bird; D.O. Caldwell; M. Cavalli-Sforza; J.A. Coller; P. Coyle; D. G. Coyne; S. Dasu; S. Dolinsky; A. D`Oliveira; J. Duboscq; W. Dunwoodie; G.D. Hallewell; K. Hasegawa; Y. Hasegawa; J. Huber; Y. Iwasaki; P. Jacques; R. A. Johnson; M. Kalelkar; H. Kawahara; Y. Kwon; D. W. G. S. Leith

We report first results from the initial physics run of the Cherenkov Ring Imaging Detector (CRID) in the SLD experiment at the SLC. We describe the experimental conditions, show liquid and gas rings, report the number of photoelectrons per ring, and comment on resolution.


nuclear science symposium and medical imaging conference | 1991

Initial performance of the SLD Cherenkov ring imaging detector system

K. Abe; P. Antilogus; D. Aston; K. Baird; Andrew J. Bean; T. Bienz; F. Bird; D.O. Caldwell; M. Cavalli-Sforza; P. Coyle; D. G. Coyne; S. Dasu; S. Dolinsky; A.B. d'Oliveira; J. Duboscq; W. Dunwoodie; P. Gagnon; G.D. Hallewell; K. Hasegawa; J. Huber; P. Jacques; R. A. Johnson; M. Kalelkar; H. Kawahara; Y. Kwon; D. W. G. S. Leith; X. Liu; A. Lu; J. Martinez; L. Mathys

All of the major subsystems for the barrel Cerenkov Ring Imaging Detector (CRID) in the SLAC Large Detector (SLD) at Stanford Linear Accelerator Center (SLAC) have now been commissioned. The CRID participated in the SLD engineering run of June-August 1991. In a cosmic ray test at the end of the run, Cerenkov rings were observed for the first time. Initial data for the CRID, including Cerenkov rings, studies of minimum ionizing particles, and data from the fiber optics calibration system are presented. The SLD engineering run and the ensuing dedicated CRID test runs have demonstrated that the system behaves as expected. It has been possible to track particles using ionization in the drift boxes and to reconstruct single electron coordinates very well. The runs have also enabled debugging of this complex system.<<ETX>>


nuclear science symposium and medical imaging conference | 1994

Results from the SLD barrel CRID detector

K. Abe; P. Antilogus; D. Aston; K.G. Baird; Andrew J. Bean; R. Ben-David; T. Bienz; F. Bird; D.O. Caldwell; M. Cavalli-Sforza; J.A. Coller; P. Coyle; D. G. Coyne; S. Dasu; S. Dolinsky; A.B. d'Oliveira; J. Duboscq; W. Dunwoodie; G.D. Hallewell; K. Hasegawa; Y. Hasegawa; J. Huber; Y. Iwasaki; P. Jacques; R. A. Johnson; M. Kalelkar; H. Kawahara; Y. Kwon; D. W. G. S. Leith; X. Liu

We report on operational experience with and experimental performance of the SLD barrel Cherenkov Ring Imaging Detector from the 1992 and 1993 physics runs. The liquid (C/sub 6/F/sub 14/) and gas (C/sub 5/F/sub 12/) radiator recirculation systems have performed well, and the drift gas supply system has operated successfully with TMAE for three years. Cherenkov rings have been observed from both the liquid and gas radiators. The number and angular resolution of Cherenkov photons have been measured, and found to be close to design specifications. >


ieee nuclear science symposium | 1990

Component And System Tests Of The SLD Cerenkov Ring Imaging Detector

P. Antilogus; D. Aston; T. Bienz; F. Bird; S. Dasu; S. Dolinsky; W. Dunwoodie; G.D. Hallewell; H. Kawahara; Y. Kwon; D. W. G. S. Leith; D. R. Muller; T. Nagamine; T.J. Pavel; B. N. Ratcliff; P.E. Rensing; D. Schultz; S. Shapiro; C. Simopoulos; E. Solodov; N. Toge; J. Va'vra; Sh Williams; M. Cavalli-Sforza; P. Coyle; D. G. Coyne; P. Gagnon; X. Liu; Dc Williams; Js Whitaker

The components of the SLD barrel Cerenkov Ring Imaging Detector (CRID) are now built and are being installed. We report on tests of these, including tests of the fiber optic calibration system, detailed studies of electron drift paths on production drift boxes and detectors, tests of the dynamic gating system and its effect on drift path distortions due to space-charge, and a measurement of the electron lifetime in a production drift box. In addition, we report on the UV transmission of recirculated liquid C{sub 6}F{sub 14} and on the effects of CRID construction materials on electron lifetime. 9 refs., 11 figs.


nuclear science symposium and medical imaging conference | 1995

The endcap Cherenkov ring imaging detector at SLD

K. Abe; P. Antilogus; D. Aston; K.G. Baird; C. Baltay; A. Bean; R. Ben-David; T. Bienz; F. Bird; D.O. Caldwell; M. Cavalli-Sforza; J.A. Coller; P. Coyle; D. G. Coyne; M. Dima; S. Dolinsky; A.B. d'Oliveira; J. Duboscq; W. Dunwoodie; G.D. Hallewell; K. Hasegawa; Y. Hasegawa; J. Huber; Y. Iwasaki; P. Jacques; R. A. Johnson; M. Kalelkar; H. Kawahara; Y. Kwon; Dwg Leith

We present the Cherenkov ring imaging detector in the endcap regions of the SLD detector and report initial performance. The endcap CRID was completed and commissioned in 1993 and is fully operational for the 1994 run. First Cherenkov rings have been observed. The endcap CRID detectors and fluid systems are described and initial operational experience is discussed. >


ieee nuclear science symposium | 1994

Performance of the endcap Cherenkov ring imaging detector at SLD

K. Abe; P. Antilogus; D. Aston; K.G. Baird; Andrew J. Bean; R. Ben-David; T. Bienz; F. Bird; D.O. Caldwell; M. Cavalli-Sforza; J.A. Coller; P. Coyle; D. G. Coyne; S. Dasu; M. Dima; S. Dolinsky; A.B. d'Oliveira; J. Duboscq; W. Dunwoodie; G.D. Hallewell; K. Hasegawa; Y. Hasegawa; J. Huber; Y. Iwasaki; P. Jacques; R. A. Johnson; M. Kalelkar; H. Kawahara; Y. Kwon; D. W. G. S. Leith

We present the Cherenkov Ring Imaging Detector in the endcap regions of the SLD detector and report on initial performance during the 1993 and 1994 runs at the SLC. The endcap CRID was completed and commissioned in 1993 and is fully operational for the 1994 run. First Cherenkov rings have been observed. The endcap CRID detectors and fluid systems are described and initial operational experience is discussed.<<ETX>>


Physical Review Letters | 1994

Measurement of the charged multiplicity of [ital Z][sup 0][r arrow][ital b[bar b]] events

K. Abe; I. Abt; W.W. Ash; D. Aston; N. Bacchetta; K.G. Baird; C. Baltay; H. R. Band; M.B. Barakat; G. Baranko; O. Bardon; R. Battiston; A.O. Bazarko; Andrew J. Bean; R.J. Belcinski; R. Ben-David; A. C. Benvenuti; M. Biasini; T. Bienz; G. M. Bilei; D. Bisello; G. Blaylock; J.R. Bogart; T. A. Bolton; G.R. Bower; Je Brau; M. Breidenbach; W. Bugg; D. L. Burke; T. H. Burnett

Using an impact parameter tag to select an enriched sample of

Collaboration


Dive into the J. Duboscq's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Andrew J. Bean

University of Texas Health Science Center at Houston

View shared research outputs
Top Co-Authors

Avatar

D.O. Caldwell

University of California

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge