Journal of Biomechanics | 2014

Comparison of eight published static finite element models of the intact lumbar spine: Predictive power of models improves when combined together

Marcel Dreischarf; Thomas Zander; A. Shirazi-Adl; Christian M. Puttlitz; Clayton J. Adam; Chen-Sheng Chen; Vijay K. Goel; Ata M. Kiapour; Yoon Hyuk Kim; K.M. Labus; J.P. Little; Won Man Park; Y.H. Wang; H.J. Wilke; A. Rohlmann; Hendrik Schmidt

Finite element (FE) model studies have made important contributions to our understanding of functional biomechanics of the lumbar spine. However, if a model is used to answer clinical and biomechanical questions over a certain population, their inherently large inter-subject variability has to be considered. Current FE model studies, however, generally account only for a single distinct spinal geometry with one set of material properties. This raises questions concerning their predictive power, their range of results and on their agreement with in vitro and in vivo values. Eight well-established FE models of the lumbar spine (L1-5) of different research centers around the globe were subjected to pure and combined loading modes and compared to in vitro and in vivo measurements for intervertebral rotations, disc pressures and facet joint forces. Under pure moment loading, the predicted L1-5 rotations of almost all models fell within the reported in vitro ranges, and their median values differed on average by only 2° for flexion-extension, 1° for lateral bending and 5° for axial rotation. Predicted median facet joint forces and disc pressures were also in good agreement with published median in vitro values. However, the ranges of predictions were larger and exceeded those reported in vitro, especially for the facet joint forces. For all combined loading modes, except for flexion, predicted median segmental intervertebral rotations and disc pressures were in good agreement with measured in vivo values. In light of high inter-subject variability, the generalization of results of a single model to a population remains a concern. This study demonstrated that the pooled median of individual model results, similar to a probabilistic approach, can be used as an improved predictive tool in order to estimate the response of the lumbar spine.


Medical Engineering & Physics | 2010

Development of a multi-scale finite element model of the osteoporotic lumbar vertebral body for the investigation of apparent level vertebra mechanics and micro-level trabecular mechanics

Katrina A. McDonald; J.P. Little; Mark J. Pearcy; Clayton J. Adam

Osteoporotic spinal fractures are a major concern in ageing Western societies. This study develops a multi-scale finite element (FE) model of the osteoporotic lumbar vertebral body to study the mechanics of vertebral compression fracture at both the apparent (whole vertebral body) and micro-structural (internal trabecular bone core) levels. Model predictions were verified against experimental data, and found to provide a reasonably good representation of the mechanics of the osteoporotic vertebral body. This novel modelling methodology will allow detailed investigation of how trabecular bone loss in osteoporosis affects vertebral stiffness and strength in the lumbar spine.


Computer Methods in Biomechanics and Biomedical Engineering | 2008

Are coupled rotations in the lumbar spine largely due to the osseo-ligamentous anatomy?--a modeling study.

J.P. Little; H. de Visser; Mark J. Pearcy; Clayton J. Adam

Prior studies have found that primary rotations in the lumbar spine are accompanied by coupled out-of-plane rotations. However, it is not clear whether these accompanying rotations are primarily due to passive (discs, ligaments and facet joints) or active (muscles) spinal anatomy. The aim of this study was to use a finite element (FE) model of the lumbar spine to predict three-dimensional coupled rotations between the lumbar vertebrae, due to passive spinal structures alone. The FE model was subjected to physiologically observed whole lumbar spine rotations about in vivo centres of rotation. Model predictions were validated by comparison of intra-discal pressures and primary rotations with in vivo measurements and these showed close agreement. Predicted coupled rotations matched in vivo measurements for all primary motions except lateral bending. We suggest that coupled rotations accompanying primary motions in the sagittal (flexion/extension) and transverse (axial rotation) planes are primarily due to passive spinal structures. For lateral bending the muscles most likely play a key role in the coupled rotation of the spine.


Clinical Biomechanics | 2011

Effects of surgical joint destabilization on load sharing between ligamentous structures in the thoracic spine: a finite element investigation.

J.P. Little; Clayton J. Adam

BACKGROUND In vitro investigations have demonstrated the importance of the ribcage in stabilizing the thoracic spine. Surgical alterations of the ribcage may change load-sharing patterns in the thoracic spine. Computer models are used in this study to explore the effect of surgical disruption of the rib-vertebrae connections on ligament load-sharing in the thoracic spine. METHODS A finite element model of a T7-8 motion segment, including the T8 rib, was developed using CT-derived spinal anatomy for the Visible Woman. Both the intact motion segment and the motion segment with four successive stages of destabilization (discectomy and removal of right costovertebral joint, right costotransverse joint and left costovertebral joint) were analyzed for a 2000 Nmm moment in flexion/extension, lateral bending and axial rotation. Joint rotational moments were compared with existing in vitro data and a detailed investigation of the load sharing between the posterior ligaments carried out. FINDINGS The simulated motion segment demonstrated acceptable agreement with in vitro data at all stages of destabilization. Under lateral bending and axial rotation, the costovertebral joints were of critical importance in resisting applied moments. In comparison to the intact joint, anterior destabilization increases the total moment contributed by the posterior ligaments. INTERPRETATION Surgical removal of the costovertebral joints may lead to excessive rotational motion in a spinal joint, increasing the risk of overload and damage to the remaining ligaments. The findings of this study are particularly relevant for surgical procedures involving rib head resection, such as some techniques for scoliosis deformity correction.


Journal of The Mechanical Behavior of Biomedical Materials | 2009

Development of a biaxial compression device for biological samples: preliminary experimental results for a closed cell foam.

J.P. Little; Gregory Tevelen; Clayton J. Adam; John Evans; Mark J. Pearcy

Biological tissues are subjected to complex loading states in vivo and in order to define constitutive equations that effectively simulate their mechanical behaviour under these loads, it is necessary to obtain data on the tissues response to multiaxial loading. Single axis and shear testing of biological tissues is often carried out, but biaxial testing is less common. We sought to design and commission a biaxial compression testing device, capable of obtaining repeatable data for biological samples. The apparatus comprised a sealed stainless steel pressure vessel specifically designed such that a state of hydrostatic compression could be created on the test specimen while simultaneously unloading the sample along one axis with an equilibrating tensile pressure. Thus a state of equibiaxial compression was created perpendicular to the long axis of a rectangular sample. For the purpose of calibration and commissioning of the vessel, rectangular samples of closed cell ethylene vinyl acetate (EVA) foam were tested. Each sample was subjected to repeated loading, and nine separate biaxial experiments were carried out to a maximum pressure of 204 kPa (30 psi), with a relaxation time of two hours between them. Calibration testing demonstrated the force applied to the samples had a maximum error of 0.026 N (0.423% of maximum applied force). Under repeated loading, the foam sample demonstrated lower stiffness during the first load cycle. Following this cycle, an increased stiffness, repeatable response was observed with successive loading. While the experimental protocol was developed for EVA foam, preliminary results on this material suggest that this device may be capable of providing test data for biological tissue samples. The load response of the foam was characteristic of closed cell foams, with consolidation during the early loading cycles, then a repeatable load-displacement response upon repeated loading. The repeatability of the test results demonstrated the ability of the test device to provide reproducible test data and the low experimental error in the force demonstrated the reliability of the test data.


Clinical Biomechanics | 2016

Understanding how axial loads on the spine influence segmental biomechanics for idiopathic scoliosis patients: A magnetic resonance imaging study

J.P. Little; Mark J. Pearcy; Maree T. Izatt; Koen Boom; Robert D. Labrom; Geoffrey N. Askin; Clayton J. Adam

BACKGROUND Segmental biomechanics of the scoliotic spine are important since the overall spinal deformity is comprised of the cumulative coronal and axial rotations of individual joints. This study investigates the coronal plane segmental biomechanics for adolescent idiopathic scoliosis patients in response to physiologically relevant axial compression. METHODS Individual spinal joint compliance in the coronal plane was measured for a series of 15 idiopathic scoliosis patients using axially loaded magnetic resonance imaging. Each patient was first imaged in the supine position with no axial load, and then again following application of an axial compressive load. Coronal plane disc wedge angles in the unloaded and loaded configurations were measured. Joint moments exerted by the axial compressive load were used to derive estimates of individual joint compliance. FINDINGS The mean standing major Cobb angle for this patient series was 46°. Mean intra-observer measurement error for endplate inclination was 1.6°. Following loading, initially highly wedged discs demonstrated a smaller change in wedge angle, than less wedged discs for certain spinal levels (+2,+1,-2 relative to the apex, (p<0.05)). Highly wedged discs were observed near the apex of the curve, which corresponded to lower joint compliance in the apical region. INTERPRETATION While individual patients exhibit substantial variability in disc wedge angles and joint compliance, overall there is a pattern of increased disc wedging near the curve apex, and reduced joint compliance in this region. Approaches such as this can provide valuable biomechanical data on in vivo spinal biomechanics of the scoliotic spine, for analysis of deformity progression and surgical planning.


Journal of Biomechanics | 2007

The Effect of Implant Alignment on Bone and Cement Stresses Following Hip Resurfacing Arthroplasty

J.P. Little; H.S. Gill

INTRODUCTION Hip resurfacing arthroplasty (HRA) has seen a resurgence in the past decade, in particular for treatment of osteoarthritis in younger, more active patients. Short-term femoral neck fracture and aseptic loosening are two main causes of HRA failure [1]. Among others, implant alignment has been suggested as a risk factor for femoral neck fracture [2,3]. This study aimed to compare the results from finite element (FE) models of an intact and an HRA-implanted femur, to investigate the effect of different implant alignments.


Clinical Biomechanics | 2016

Intra-operative measurement of applied forces during anterior scoliosis correction

H. Fairhurst; J.P. Little; Clayton J. Adam

BACKGROUND Spinal instrumentation and fusion for the treatment of scoliosis is primarily a mechanical intervention to correct the deformity and halt further progression. While implant-related complications remain a concern, little is known about the magnitudes of the forces applied to the spine during surgery, which may affect post-surgical outcomes. In this study, the compressive forces applied to each spinal segment during anterior instrumentation were measured in a series of patients with Adolescent Idiopathic Scoliosis. METHODS A force transducer was designed and retrofit to a routinely used surgical tool, and compressive forces applied to each segment during surgery were measured for 15 scoliosis patients. Cobb angle correction achieved by each force was measured on intra-operative fluoroscope images. Relative changes in orientation of the screw within the vertebra were also measured to detect intra-operative screw plough. FINDINGS Intra-operative forces were measured for a total of 95 spinal segments. The mean applied compressive force was 540N (SD 230N, range 88N-1019N). There was a clear trend for higher forces to be applied at segments toward the apex of the scoliosis. Fluoroscopic evidence of screw plough was detected at 10 segments (10.5%). INTERPRETATION The magnitude of forces applied during anterior scoliosis correction vary over a broad range. These forces do reach magnitudes capable of causing intra-operative vertebral body screw plough. Surgeons should be aware there is a risk for tissue overload during correction, however the clinical implications of intra-operative screw plough remain unclear. The dataset presented here is valuable for providing realistic input parameters for in silico surgical simulations.


Journal of Biomechanics | 2007

ARE COUPLED ROTATIONS IN THE LUMBAR SPINE A CONSEQUENCE OF THE OSSEOLIGAMENTOUS ANATOMY

J.P. Little; Mark J. Pearcy; Clayton J. Adam

INTRODUCTION Previous studies have found that primary rotations in the lumbar spine are accompanied by coupled out-of-plane rotations. However, it is not clear whether this accompanying rotation is due to passive (discs, ligaments and facet joints) or active (muscles) spinal anatomy. The aim of this study was to use a finite element model of the lumbar spine to determine three-dimensional rotations in the loaded spine, due to passive spinal anatomy alone.


Journal of Biomechanics | 2007

Nonlinear finite element analysis of anular lesions in the L4/5 intervertebral disc.

J.P. Little; Clayton J. Adam; John Evans; Mark J. Pearcy

Collaboration


Dive into the J.P. Little's collaboration.

Top Co-Authors

Avatar

Clayton J. Adam

Queensland University of Technology

View shared research outputs
Top Co-Authors

Avatar

Mark J. Pearcy

Queensland University of Technology

View shared research outputs
Top Co-Authors

Avatar

John Evans

Queensland University of Technology

View shared research outputs
Top Co-Authors

Avatar

Gregory Tevelen

Queensland University of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

A. Shirazi-Adl

École Polytechnique de Montréal

View shared research outputs
Top Co-Authors

Avatar

Ata M. Kiapour

Boston Children's Hospital

View shared research outputs
Researchain Logo
Decentralizing Knowledge