Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where J.R. Paisey is active.

Publication


Featured researches published by J.R. Paisey.


Journal of Interventional Cardiac Electrophysiology | 2003

Comparison of Coronary Venous Defibrillation with Conventional Transvenous Internal Defibrillation in Man

Paul R. Roberts; J.R. Paisey; Tim R. Betts; Stuart Allen; Theresa Whitman; M. Bonner; J.M. Morgan

AbstractObjective: Animal studies have shown that defibrillation in coronary veins is more effective than in the right ventricle. We aimed to assess the feasibility of placing defibrillation electrodes in the middle cardiac vein (MCV) in man and its impact on defibrillation requirements. Methods: A prospective randomised study conducted in a tertiary referral centre. 10 patients (9 male) undergoing ICD implantation (65 (12) yrs) for NASPE/BPEG indications were studied. Defibrillation thresholds (DFT) were measured, using a binary search and an external defibrillator after 10 seconds of ventricular fibrillation, for the following configurations in each patient (order of testing randomised): RV + MCV → Can and RV → SVC + Can. Interventions: A dual coil defibrillation electrode was placed transvenously in the right ventricle (RV) in the conventional manner. Using a guiding catheter a 3.2 Fr (67.5 mm length) electrode was placed transvenously in MCV. A test-can was placed subcutaneously in the left pectoral region. Results: Lead placement was possible in 8/10 pts. Time to perform a middle cardiac venogram and place the electrode was 21 (23) mins. No adverse events were observed. Defibrillation current was less (6.7 (2.7) A) with RV + MCV → Can compared to the conventional RV → SVC + Can configuration (8.9 (3.4) A, p = 0.03). There was no significant difference in defibrillation voltage or energy. However, shock impedance was higher in the former configuration (57 (10) v. 43 (6) Ω, p = 0.001). Conclusions: In the majority of cases placement of a defibrillation lead in MCV is feasible. Defibrillation current requirements are 25% less when the shock is delivered using a MCV electrode.


Europace | 2006

Defibrillator and cardiac resynchronization therapy after mustard surgery for trans position of the great arteries

K.A. Michael; J.R. Paisey; Arthur M. Yue; Nadia S. Sunni; Sian Robinson; Paul R. Roberts; J.M. Morgan; Gruschen R. Veldtman; Stuart Allen

15th World Congress in Cardiac Electrophysiology and Cardiac Techniques: Cardiostim 2006, Nice–French Riviera, France, 14-17 June 2006. In Europace, 2006, v. 8 Supplement 1, p. 43/5


Europace | 2006

Value of pre-discharge defbrillator testing

J.R. Paisey; S.J. Ankolevar; R.L. Gough; J.M. Morgan; Paul R. Roberts; H. Clothier; Arthur M. Yue

15th World Congress in Cardiac Electrophysiology and Cardiac Techniques: Cardiostim 2006, Nice–French Riviera, France, 14-17 June 2006. In Europace, 2006, v. 8 Supplement 1, p. 43/5


International Journal of Cardiology | 2005

Implantable loop recorders detect tachyarrhythmias in symptomatic patients with negative electrophysiological studies

J.R. Paisey; Arthur M. Yue; Kenneth Treacher; Paul R. Roberts; John M. Morgan


Pediatric Cardiology | 2009

Renal Function of Patients with a Failing Fontan Circuit Undergoing Total Cavopulmonary Revision Surgery

Fatin Sammour; Marcus P. Haw; J.R. Paisey; Richard Cope; Mike Herbertson; Tony Salmon; Joseph J. Vettukattil; Mary Rogerson; Varvara Karagkiozaki; Gruschen R. Veldtman


International Journal of Cardiology | 2005

Development of indications for cardiac resynchronisation therapy in the implantable cardioverter defibrillator population

J.R. Paisey; Arthur M. Yue; Rien Moore; Tim R. Betts; Paul R. Roberts; John M. Morgan


Journal of Interventional Cardiac Electrophysiology | 2008

A hybrid form of cardiac resynchronisation therapy in patients with failing systemic right ventricles

Kevin A. Michael; J.R. Paisey; Bongani M. Mayosi; Stephen Robinson; Stuart Allen; Nadia S. Sunni; Paul R. Roberts; John M. Morgan; Gruschen R. Veldtman


Europace | 2004

Evaluation of body weight as a predictive factor for transvenous ventricular defibrillation characteristics

J.R. Paisey; Tim R. Betts; Stuart Allen; J.M. Morgan; Paul R. Roberts


Europace | 2003

P-233 Description of a new phenotype related to sudden cardiac death

J.M. Morgan; B. Skaria; Y. Yue; J.R. Paisey; Paul R. Roberts; David I. Wilson


Europace | 2003

P-140 Use of maximum entry point radiation dose to risk stratify electrophysiological procedures for deterministic skin damage

J.R. Paisey; A. White; A. Moss; Arthur M. Yue; J. Butchart; J.M. Morgan; Paul R. Roberts

Collaboration


Dive into the J.R. Paisey's collaboration.

Top Co-Authors

Avatar

Paul R. Roberts

University of Southampton

View shared research outputs
Top Co-Authors

Avatar

J.M. Morgan

University of Southampton

View shared research outputs
Top Co-Authors

Avatar

Arthur M. Yue

University of Southampton

View shared research outputs
Top Co-Authors

Avatar

Tim R. Betts

Southampton General Hospital

View shared research outputs
Top Co-Authors

Avatar

Stuart Allen

University of Southampton

View shared research outputs
Top Co-Authors

Avatar

John M. Morgan

University of Southampton

View shared research outputs
Top Co-Authors

Avatar

Y. Yue

University of Southampton

View shared research outputs
Top Co-Authors

Avatar

Gruschen R. Veldtman

Cincinnati Children's Hospital Medical Center

View shared research outputs
Top Co-Authors

Avatar

Nadia S. Sunni

Southampton General Hospital

View shared research outputs
Top Co-Authors

Avatar

Sian Robinson

University of Southampton

View shared research outputs
Researchain Logo
Decentralizing Knowledge