Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Jack Wanger is active.

Publication


Featured researches published by Jack Wanger.


European Respiratory Journal | 2005

Standardisation of spirometry

M.R. Miller; John L. Hankinson; Vito Brusasco; Felip Burgos; Richard Casaburi; Allan L. Coates; Robert O. Crapo; Paul L. Enright; C.P.M. van der Grinten; P. Gustafsson; Robert L. Jensen; D.C. Johnson; Neil R. MacIntyre; Roy T. McKay; Daniel Navajas; O.F. Pedersen; R. Pellegrino; G. Viegi; Jack Wanger

[⇓][1] SERIES “ATS/ERS TASK FORCE: STANDARDISATION OF LUNG FUNCTION TESTING” Edited by V. Brusasco, R. Crapo and G. Viegi Number 2 in this Series [1]: #F13


European Respiratory Journal | 2005

Interpretative strategies for lung function tests

Pellegrino R; Viegi G; Brusasco; Robert O. Crapo; Felip Burgos; Richard Casaburi; Allan L. Coates; van der Grinten Cp; P. Gustafsson; John L. Hankinson; Robert L. Jensen; D.C. Johnson; Neil R. MacIntyre; Roy T. McKay; M.R. Miller; Daniel Navajas; O.F. Pedersen; Jack Wanger

SERIES “ATS/ERS TASK FORCE: STANDARDISATION OF LUNG FUNCTION TESTING” Edited by V. Brusasco, R. Crapo and G. Viegi Number 5 in this Series This section is written to provide guidance in interpreting pulmonary function tests (PFTs) to medical directors of hospital-based laboratories that perform PFTs, and physicians who are responsible for interpreting the results of PFTs most commonly ordered for clinical purposes. Specifically, this section addresses the interpretation of spirometry, bronchodilator response, carbon monoxide diffusing capacity ( D L,CO) and lung volumes. The sources of variation in lung function testing and technical aspects of spirometry, lung volume measurements and D L,CO measurement have been considered in other documents published in this series of Task Force reports 1–4 and in the American Thoracic Society (ATS) interpretative strategies document 5. An interpretation begins with a review and comment on test quality. Tests that are less than optimal may still contain useful information, but interpreters should identify the problems and the direction and magnitude of the potential errors. Omitting the quality review and relying only on numerical results for clinical decision making is a common mistake, which is more easily made by those who are dependent upon computer interpretations. Once quality has been assured, the next steps involve a series of comparisons 6 that include comparisons of test results with reference values based on healthy subjects 5, comparisons with known disease or abnormal physiological patterns ( i.e. obstruction and restriction), and comparisons with self, a rather formal term for evaluating change in an individual patient. A final step in the lung function report is to answer the clinical question that prompted the test. Poor choices made during these preparatory steps increase the risk of misclassification, i.e. a falsely negative or falsely positive interpretation for a lung function abnormality or a change …


European Respiratory Journal | 2005

Standardisation of the measurement of lung volumes

Jack Wanger; J.L. Clausen; Allan L. Coates; O.F. Pedersen; Vito Brusasco; Felip Burgos; Richard Casaburi; Robert O. Crapo; Paul L. Enright; C.P.M. van der Grinten; P. Gustafsson; John L. Hankinson; Robert L. Jensen; D.C. Johnson; Neil R. MacIntyre; Roy T. McKay; M.R. Miller; Daniel Navajas; R. Pellegrino; G. Viegi

[⇓][1] SERIES “ATS/ERS TASK FORCE: STANDARDISATION OF LUNG FUNCTION TESTING” Edited by V. Brusasco, R. Crapo and G. Viegi Number 3 in this Series [1]: #F7


European Respiratory Journal | 2005

Standardisation of the single-breath determination of carbon monoxide uptake in the lung

Neil R. MacIntyre; Robert O. Crapo; G. Viegi; D.C. Johnson; van der Grinten Cp; Brusasco; Felip Burgos; Richard Casaburi; Allan L. Coates; Paul L. Enright; P. Gustafsson; John L. Hankinson; Robert L. Jensen; Roy T. McKay; M.R. Miller; Daniel Navajas; O.F. Pedersen; R. Pellegrino; Jack Wanger

[⇓][1] SERIES “ATS/ERS TASK FORCE: STANDARDISATION OF LUNG FUNCTION TESTING” Edited by V. Brusasco, R. Crapo and G. Viegi Number 4 in this Series [1]: #F4


European Respiratory Journal | 2005

General considerations for lung function testing.

M.R. Miller; Robert O. Crapo; John L. Hankinson; Vito Brusasco; Felip Burgos; Richard Casaburi; Allan L. Coates; Paul L. Enright; C.P.M. van der Grinten; P. Gustafsson; Robert L. Jensen; D.C. Johnson; Neil R. MacIntyre; Roy T. McKay; Daniel Navajas; O.F. Pedersen; R. Pellegrino; G. Viegi; Jack Wanger

SERIES “ATS/ERS TASK FORCE: STANDARDISATION OF LUNG FUNCTION TESTING” Edited by V. Brusasco, R. Crapo and G. Viegi Number 1 in this Series ⇓In preparing the joint statements on lung function testing for the American Thoracic Society (ATS) and the European Respiratory Society (ERS), it was agreed by the working party that the format of the statements should be modified so that they were easier to use by both technical and clinical staff. This statement contains details about procedures that are common for many methods of lung function testing and, hence, are presented on their own. A list of abbreviations used in all the documents is also included as part of this statement. All terms and abbreviations used here are based on a report of the American College of Chest Physicians/ATS Joint Committee on Pulmonary Nomenclature 1. The metrology definitions agreed by the International Standards Organization (ISO) are recommended 2 and some important terms are defined as follows. Accuracy is the closeness of agreement between the result of a measurement and the conventional true value. Repeatability is the closeness of agreement between the results of successive measurements of the same item carried out, subject to all of the following conditions: same method, same observer, same instrument, same location, same condition of use, and repeated over a short space of time. In previous documents, the term reproducibility was used in this context, and this represents a change towards bringing this document in line with the ISO. Reproducibility is the closeness of agreement of the results of successive measurements of the same item where the individual measurements are carried out with changed conditions, such as: method of measurement, observer, instrument, location, conditions of use, and time. Thus, if a technician tests a subject several times, this is looking at the …


European Respiratory Journal | 2014

An official European Respiratory Society/American Thoracic Society technical standard: field walking tests in chronic respiratory disease

Anne E. Holland; Martijn A. Spruit; Thierry Troosters; Milo A. Puhan; Didier Saey; Meredith C. McCormack; Brian Carlin; Frank C. Sciurba; Fabio Pitta; Jack Wanger; Neil R. MacIntyre; David A. Kaminsky; Bruce H. Culver; Susan M. Revill; Nidia A. Hernandes; Vasileios Andrianopoulos; Carlos Augusto Camillo; Katy Mitchell; Annemarie Lee; Catherine J. Hill; Sally Singh

Field walking tests are commonly employed to evaluate exercise capacity, assess prognosis and evaluate treatment response in chronic respiratory diseases. In recent years, there has been a wealth of new literature pertinent to the conduct of the 6-min walk test (6MWT), and a growing evidence base describing the incremental and endurance shuttle walk tests (ISWT and ESWT, respectively). The aim of this document is to describe the standard operating procedures for the 6MWT, ISWT and ESWT, which can be consistently employed by clinicians and researchers. The Technical Standard was developed by a multidisciplinary and international group of clinicians and researchers with expertise in the application of field walking tests. The procedures are underpinned by a concurrent systematic review of literature relevant to measurement properties and test conduct in adults with chronic respiratory disease. Current data confirm that the 6MWT, ISWT and ESWT are valid, reliable and responsive to change with some interventions. However, results are sensitive to small changes in methodology. It is important that two tests are conducted for the 6MWT and ISWT. This Technical Standard for field walking tests reflects current evidence regarding procedures that should be used to achieve robust results. Technical Standard document: standard operating procedures for the 6MWT, ISWT and ESWT in chronic respiratory disease http://ow.ly/Bq2B9


European Respiratory Journal | 2014

An official systematic review of the European Respiratory Society/American Thoracic Society: measurement properties of field walking tests in chronic respiratory disease

Sally Singh; Milo A. Puhan; Vasileios Andrianopoulos; Nidia A. Hernandes; Katy Mitchell; Catherine J. Hill; Annemarie Lee; Carlos Augusto Camillo; Thierry Troosters; Martijn A. Spruit; Brian Carlin; Jack Wanger; Véronique Pepin; Didier Saey; Fabio Pitta; David A. Kaminsky; Meredith C. McCormack; Neil R. MacIntyre; Bruce H. Culver; Frank C. Sciurba; Susan M. Revill; Veronica Delafosse; Anne E. Holland

This systematic review examined the measurement properties of the 6-min walk test (6MWT), incremental shuttle walk test (ISWT) and endurance shuttle walk test (ESWT) in adults with chronic respiratory disease. Studies that report the evaluation or use of the 6MWT, ISWT or ESWT were included. We searched electronic databases for studies published between January 2000 and September 2013. The 6-min walking distance (6MWD) is a reliable measure (intra-class correlation coefficients ranged from 0.82 to 0.99 in seven studies). There is a learning effect, with greater distance walked on the second test (pooled mean improvement of 26 m in 13 studies). Reliability was similar for ISWT and ESWT, with a learning effect also evident for ISWT (pooled mean improvement of 20 m in six studies). The 6MWD correlates more strongly with peak work capacity (r=0.59–0.93) and physical activity (r=0.40–0.85) than with respiratory function (r=0.10–0.59). Methodological factors affecting 6MWD include track length, encouragement, supplemental oxygen and walking aids. Supplemental oxygen also affects ISWT and ESWT performance. Responsiveness was moderate to high for all tests, with greater responsiveness to interventions that included exercise training. The findings of this review demonstrate that the 6MWT, ISWT and ESWT are robust tests of functional exercise capacity in adults with chronic respiratory disease. Systematic review: support for use of the 6MWT, ISWT and ESWT in adults with chronic respiratory disease http://ow.ly/Bq2Mz


Clinics in Chest Medicine | 2001

Single-breath carbon monoxide diffusing capacity.

Robert O. Crapo; Robert L. Jensen; Jack Wanger

Measurement of DL(CO) remains a clinically useful way to assess transfer of gases across the lung. It is important, however, to be vigilant in controlling the sources of variation and to be aware of those that remain when interpreting the measured values.


European Respiratory Journal | 2016

FG-3019 anti-connective tissue growth factor monoclonal antibody: results of an open-label clinical trial in idiopathic pulmonary fibrosis.

Ganesh Raghu; Mary Beth Scholand; Joao A. de Andrade; Lisa H. Lancaster; Yolanda Mageto; Jonathan G. Goldin; Kevin K. Brown; Kevin R. Flaherty; Mark Wencel; Jack Wanger; Thomas Neff; Frank Valone; John Stauffer; Seth Porter

FG-3019 is a fully human monoclonal antibody that interferes with the action of connective tissue growth factor, a central mediator in the pathogenesis of fibrosis. This open-label phase 2 trial evaluated the safety and efficacy of two doses of FG-3019 administered by intravenous infusion every 3 weeks for 45 weeks in patients with idiopathic pulmonary fibrosis (IPF). Subjects had a diagnosis of IPF within the prior 5 years defined by either usual interstitial pneumonia (UIP) pattern on a recent high-resolution computed tomography (HRCT) scan, or a possible UIP pattern on HRCT scan and a recent surgical lung biopsy showing UIP pattern. Pulmonary function tests were performed every 12 weeks, and changes in the extent of pulmonary fibrosis were measured by quantitative HRCT scans performed at baseline and every 24 weeks. FG-3019 was safe and well-tolerated in IPF patients participating in the study. Changes in fibrosis were correlated with changes in pulmonary function. Further investigation of FG-3019 in IPF with a placebo-controlled clinical trial is warranted and is underway. FG-3019 demonstrated good outcomes in changes in pulmonary function and extent of pulmonary fibrosis in IPF http://ow.ly/Xn7B4


European Respiratory Journal | 2008

Definition of COPD: based on evidence or opinion?

R. Pellegrino; Vito Brusasco; G. Viegi; Robert O. Crapo; Felip Burgos; Richard Casaburi; Allan L. Coates; C.P.M. van der Grinten; P. Gustafsson; John L. Hankinson; Robert L. Jensen; D.C. Johnson; Neil R. MacIntyre; Roy T. McKay; M.R. Miller; Daniel Navajas; O.F. Pedersen; Jack Wanger

To the Editors: In 1986, the American Thoracic Society (ATS) first suggested a fixed ratio of forced expiratory volume in one second (FEV1) to forced vital capacity (FVC) <0.75 to define airflow obstruction 1. Subsequent ATS documents published in 1991 2 and 1995 3 generically defined airflow obstruction as a reduction of FEV1/FVC, without recommending any numerical cut-off point. By contrast, the European Respiratory Society (ERS) guidelines 4 suggested the diagnosis of airflow obstruction be based on a ratio of FEV1 to slow vital capacity (VC) <88 and <89% of predicted in males and females, respectively. These values were not arbitrarily chosen as they roughly correspond to the lower 95th percentiles of frequency distributions of a healthy population. More importantly, they are consistent with the well-known decrease of lung elastic recoil and, by inference, of forced expiratory flow with ageing. In 2001, the Global Initiative for …

Collaboration


Dive into the Jack Wanger's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Allan L. Coates

Montreal Children's Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Richard Casaburi

Los Angeles Biomedical Research Institute

View shared research outputs
Top Co-Authors

Avatar

Roy T. McKay

University of Cincinnati

View shared research outputs
Top Co-Authors

Avatar

Felip Burgos

University of Barcelona

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge