Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Jaroslav Pól is active.

Publication


Featured researches published by Jaroslav Pól.


Analytical Chemistry | 2010

Laser Desorption-Ionization of Lipid Transfers: Tissue Mass Spectrometry Imaging without MALDI Matrix

Veronika Vidová; Petr Novák; Martin Strohalm; Jaroslav Pól; Vladimír Havlíček; Michael Volný

Mass spectrometry imaging of tissue-lipid transfers without MALDI matrix is demonstrated. Commercially available nanostructured surfaces (nano-assisted laser desorption-ionization or NALDI) are used as substrates for imprinting of tissue sections. The lithographic transfers are then washed and the two-dimensional distribution of the lipids is imaged by laser desorption-ionization mass spectrometry. The NALDI imaging of lipid transfers is compared with standard MALDI imaging of matrix-coated tissue sections. The obtained images are of the same quality, and no spatial information is lost due to the imprinting process. NALDI imaging is faster due to the absence of the time-consuming matrix deposition step, and the NALDI mass spectra are less complex and easier to interpret than standard MALDI. In this particular application example, NALDI mass spectrometry is able to identify the same lipid species as MALDI mass spectrometry and provides better distinction between kidney and adrenal gland tissues based on the lipid analysis.


Analytical Chemistry | 2009

Automated Ambient Desorption−Ionization Platform for Surface Imaging Integrated with a Commercial Fourier Transform Ion Cyclotron Resonance Mass Spectrometer

Jaroslav Pól; Veronika Vidová; Gary H. Kruppa; Václav Kobliha; Petr Novák; Karel Lemr; Tapio Kotiaho; Risto Kostiainen; Vladimír Havlíček; Michael Volný

A fully automated atmospheric pressure ionization platform has been built and coupled with a commercial high-resolution Fourier transform ion cyclotron resonance mass spectrometer (FTICR-MS) instrument. The outstanding performance of this instrument allowed screening on the basis of exact masses in imaging mode. The main novel aspect was in the integration of the atmospheric pressure ionization imaging into the current software for matrix-assisted laser desorption ionization (MALDI) imaging, which allows the user of this commercial dual-source mass spectrometer to perform MALDI-MS and different ambient MS imaging from the same user interface and to utilize the same software tools. Desorption electrospray ionization (DESI) and desorption atmospheric pressure photoionization (DAPPI) were chosen to test the ambient surface imaging capabilities of this new ionization platform. Results of DESI imaging experiments performed on brain tissue sections are in agreement with previous MS imaging reports obtained by DESI imaging, but due to the high resolution and mass accuracy of the FTICR instrument it was possible to resolve several ions at the same nominal mass in the DESI-MS spectra of brain tissue. These isobaric interferences at low resolution are due to the overlap of ions from different lipid classes with different biological relevance. It was demonstrated that with the use of high-resolution MS fast imaging screening of lipids can be achieved without any preseparation steps. DAPPI, which is a relatively new and less developed ambient ionization technique compared to DESI, was used in imaging mode for the first time ever. It showed promise in imaging of phytocompounds from plant leaves, and selective ionization of a sterol lipid was achieved by DAPPI from a brain tissue sample.


Histochemistry and Cell Biology | 2010

Molecular mass spectrometry imaging in biomedical and life science research

Jaroslav Pól; Martin Strohalm; Vladimír Havlíček; Michael Volný

This review describes the current state of mass spectrometry imaging (MSI) in life sciences. A brief overview of mass spectrometry principles is presented followed by a thorough introduction to the MSI workflows, principles and areas of application. Three major desorption-ionization techniques used in MSI, namely, secondary ion mass spectrometry (SIMS), matrix-assisted laser desorption ionization (MALDI), and desorption electrospray ionization (DESI) are described, and biomedical and life science imaging applications of each ionization technique are reviewed. A separate section is devoted to data handling and current challenges and future perspectives are briefly discussed at the end.


Analytical Chemistry | 2008

Desorption and ionization mechanisms in desorption atmospheric pressure photoionization.

Laura Luosujärvi; Ville Arvola; Markus Haapala; Jaroslav Pól; Ville Saarela; Sami Franssila; Tapio Kotiaho; Risto Kostiainen; Tiina J. Kauppila

The factors influencing desorption and ionization in newly developed desorption atmospheric pressure photoionization-mass spectrometry (DAPPI-MS) were studied. Redirecting the DAPPI spray was observed to further improve the versatility of the technique: for dilute samples, parallel spray with increased analyte signal was found to be the best suited, while for more concentrated samples, the orthogonal spray with less risk for contamination is recommended. The suitability of various spray solvents and sampling surface materials was tested for a variety of analytes with different polarities and molecular weights. As in atmospheric pressure photoionization, the analytes formed [M + H](+), [M - H](-), M(+*), M(-*), [M - H + O](-), or [M - 2H + 2O](-) ions depending on the analyte, spray solvent, and ionization mode. In positive ion mode, anisole and toluene as spray solvents promoted the formation of M(+*) ions and were therefore best suited for the analysis of nonpolar compounds (anthracene, benzo[a]pyrene, and tetracyclone). Acetone and hexane were optimal spray solvents for polar compounds (MDMA, testosterone, and verapamil) since they produced intensive [M + H](+) ion peaks of the analytes. In negative ion mode, the type of spray solvent affected the signal intensity, but not the ion composition. M(-*) ions were formed from 1,4-dinitrobenzene, and [M - H + O](-) and [M - 2H + 2O](-) ions from 1,4-naphthoquinone, whereas acidic compounds (naphthoic acid and paracetamol) formed [M - H](-) ions. The tested sampling surfaces included various materials with different thermal conductivities. The materials with low thermal conductivity, i.e., polymers like poly(methyl methacrylate) and poly(tetrafluoroethylene) (Teflon) were found to be the best, since they enable localized heating of the sampling surface, which was found to be essential for efficient analyte desorption. Nevertheless, the sampling surface material did not affect the ionization mechanisms.


Rapid Communications in Mass Spectrometry | 2008

Direct Analysis of Illicit Drugs by Desorption Atmospheric Pressure Photoionization

Tiina J. Kauppila; Ville Arvola; Markus Haapala; Jaroslav Pól; Laura Aalberg; Ville Saarela; Sami Franssila; Tapio Kotiaho; Risto Kostiainen

The feasibility of desorption atmospheric pressure photoionization (DAPPI) in the direct analysis of illicit drugs was demonstrated by the analysis of confiscated drug samples of various forms such as tablets, blotter paper, and plant resin and bloom. 3,4-Methylenedioxymethamphetamine (MDMA), amphetamine, phenazepam, and buprenorphine were detected from the analyzed tablets, lysergic acid diethylamide (LSD) and bromobenzodifuranylisopropylamine (bromo-Dragonfly, ABDF) from blotter paper, and Delta(9)-tetrahydrocannabinol (THC) and cannabinol from Cannabis Sativa bloom and resin. The amphetamines, phenazepam and ABDF showed protonated molecules independent of the solvent used, whereas buprenorphine, LSD and the cannabinoids showed molecular ions with toluene and protonated molecules with acetone as the solvent.


Journal of Lipid Research | 2010

Visualizing spatial lipid distribution in porcine lens by MALDI imaging high-resolution mass spectrometry

Veronika Vidová; Jaroslav Pól; Michael Volny; Petr Novák; Vladimír Havlíček; Susanne K. Wiedmer; Juha M. Holopainen

The intraocular lens contains high levels of both cholesterol and sphingolipids, which are believed to be functionally important for normal lens physiology. The aim of this study was to explore the spatial distribution of sphingolipids in the ocular lens using mass spectrometry imaging (MSI). Matrix-assisted laser desorption/ionization (MALDI) imaging with ultra high resolution Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) was used to visualize the lipid spatial distribution. Equatorially-cryosectioned, 12 μm thick slices of tissue were thaw-mounted to an indium-tin oxide (ITO) glass slide by soft-landing to an ethanol layer. This procedure maintained the tissue integrity. After the automated MALDI matrix deposition, the entire lens section was examined by MALDI MSI in a 150 μm raster. We obtained spatial- and concentration-dependent distributions of seven lens sphingomyelins (SM) and two ceramide-1-phosphates (CerP), which are important lipid second messengers. Glycosylated sphingolipids or sphingolipid breakdown products were not observed. Owing to ultra high resolution MS, all lipids were identified with high confidence, and distinct distribution patterns for each of them are presented. The distribution patterns of SMs provide an understanding of the physiological functioning of these lipids in clear lenses and offer a novel pathophysiological means for understanding diseases of the lens.


Analytical and Bioanalytical Chemistry | 2008

Comprehensive two-dimensional liquid chromatography coupled with mass spectrometry

Jaroslav Pól; Tuulia Hyötyläinen

In this review, instrumental aspects of comprehensive two-dimensional liquid chromatography coupled with mass spectrometry are presented. The milestones of LC×LC are briefly summarized. Instrument configuration, selection of experimental conditions, the different interfaces used in the system and the current applications of LC×LC–MS systems are described.


Analytica Chimica Acta | 2010

Integrated liquid chromatography - heated nebulizer microchip for mass spectrometry

Markus Haapala; Ville Saarela; Jaroslav Pól; Kai Kolari; Tapio Kotiaho; Sami Franssila; Risto Kostiainen

A new integrated microchip for liquid chromatography-mass spectrometry (LC-MS) is presented. The chip is made from bonded silicon and glass wafers with structures for a packed LC column channel, a micropillar frit, a channel for optional optical detection, and a heated vaporizer section etched in silicon and platinum heater elements on the glass cover. LC eluent is vaporized and mixed with nebulizer gas in the vaporizer section and the vapor is sprayed out from the chip. Nonpolar and polar analytes can be efficiently ionized in the gas phase by atmospheric pressure photoionization (APPI) as demonstrated with polycyclic aromatic hydrocarbons (PAHs) and selective androgen receptor modulators (SARMs). This is not achievable with present LC-MS chips, since they are based on electrospray ionization, which is not able to ionize nonpolar compounds efficiently. The preliminary quantitative performance of the new chip was evaluated in terms of limit of detection (down to 5 ng mL(-1)), linearity (r>0.999), and repeatability of signal response (RSD=2.6-4.0%) and retention time (RSD=0.3-0.5%) using APPI for ionization and PAHs as standard compounds. Determination of fluorescent compounds is demonstrated by using laser-induced fluorescence (LIF) for detection in the optical detection channel before the vaporizer section.


PLOS ONE | 2011

Spatial Distribution of Glycerophospholipids in the Ocular Lens

Jaroslav Pól; Veronika Vidová; Tuulia Hyötyläinen; Michael Volný; Petr Novák; Martin Strohalm; Risto Kostiainen; Vladimír Havlíček; Susanne K. Wiedmer; Juha M. Holopainen

Knowledge of the spatial distribution of lipids in the intraocular lens is important for understanding the physiology and biochemistry of this unique tissue and for gaining a better insight into the mechanisms underlying diseases of the lens. Following our previous study showing the spatial distribution of sphingolipids in the porcine lens, the current study used ultra performance liquid chromatography quadrupole time-of-flight mass spectrometry (UPLC-QTOFMS) to provide the whole lipidome of porcine lens and these studies were supplemented by matrix-assisted laser desorption ionization mass spectrometry imaging (MALDI MSI) of the lens using ultra-high resolution Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) to determine the spatial distribution of glycerophospholipids. Altogether 172 lipid species were identified with high confidence and their concentration was determined. Sphingomyelins, phosphatidylcholines, and phosphatidylethanolamines were the most abundant lipid classes. We then determined the spatial and concentration-dependent distributions of 20 phosphatidylcholines, 6 phosphatidylethanolamines, and 4 phosphatidic acids. Based on the planar molecular images of the lipids, we report the organization of fiber cell membranes within the ocular lens and suggest roles for these lipids in normal and diseased lenses.


European Journal of Mass Spectrometry | 2015

Age-related changes in the lateral lipid distribution in a human lens described by mass spectrometry imaging

Jaroslav Pól; Helena Faltyskova; Lukas Krasny; Michael Volný; Ondrej Vlacil; Marian Hajduch; Karel Lemr; Vladimír Havlíček

The lateral lipid distribution in eye lenses of three human donors were studied by matrix-assisted laser desorption ionization imaging mass spectrometry using a high mass resolution. By using exact mass measurements this study shows the relationship between the aging process and the number of lipids detected as well as between aging and the abundance of products derived from sphingomyelins by hydrolysis. Variable lipid composition was also observed in the nuclear, barrier, or cortex regions of the lens samples. This is the first study that suggests the distribution of lysolipids as a potential biomarker panel for the aging of human lens tissue.

Collaboration


Dive into the Jaroslav Pól's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Ville Saarela

Helsinki University of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Petr Novák

Charles University in Prague

View shared research outputs
Top Co-Authors

Avatar

Veronika Vidová

Academy of Sciences of the Czech Republic

View shared research outputs
Top Co-Authors

Avatar

Michael Volný

University of Washington

View shared research outputs
Researchain Logo
Decentralizing Knowledge