Featured researches published by Jason W. Sidabras.


Journal of Magnetic Resonance | 2008

Saturation recovery EPR and ELDOR at W-band for spin labels.

Wojciech Froncisz; Theodore G. Camenisch; Joseph J. Ratke; James R. Anderson; Witold K. Subczynski; Robert A. Strangeway; Jason W. Sidabras; James S. Hyde

A reference arm W-band (94 GHz) microwave bridge with two sample-irradiation arms for saturation recovery (SR) EPR and ELDOR experiments is described. Frequencies in each arm are derived from 2 GHz synthesizers that have a common time-base and are translated to 94 GHz in steps of 33 and 59 GHz. Intended applications are to nitroxide radical spin labels and spin probes in the liquid phase. An enabling technology is the use of a W-band loop-gap resonator (LGR) [J.W. Sidabras, R.R. Mett, W. Froncisz, T.G. Camenisch, J.R. Anderson, J.S. Hyde, Multipurpose EPR loop-gap resonator and cylindrical TE(011) cavity for aqueous samples at 94 GHz, Rev. Sci. Instrum. 78 (2007) 034701]. The high efficiency parameter (8.2 GW(-1/2) with sample) permits the saturating pump pulse level to be just 5 mW or less. Applications of SR EPR and ELDOR to the hydrophilic spin labels 3-carbamoyl-2,2,5,5-tetra-methyl-3-pyrroline-1-yloxyl (CTPO) and 2,2,6,6,-tetramethyl-4-piperidone-1-oxyl (TEMPONE) are described in detail. In the SR ELDOR experiment, nitrogen nuclear relaxation as well as Heisenberg exchange transfer saturation from pumped to observed hyperfine transitions. SR ELDOR was found to be an essential method for measurements of saturation transfer rates for small molecules such as TEMPONE. Free induction decay (FID) signals for small nitroxides at W-band are also reported. Results are compared with multifrequency measurements of T(1e) previously reported for these molecules in the range of 2-35 GHz [J.S. Hyde, J.-J. Yin, W.K. Subczynski, T.G. Camenisch, J.J. Ratke, W. Froncisz, Spin label EPR T(1) values using saturation recovery from 2 to 35 GHz. J. Phys. Chem. B 108 (2004) 9524-9529]. The values of T(1e) decrease at 94 GHz relative to values at 35 GHz.


Review of Scientific Instruments | 2007

Multipurpose EPR loop-gap resonator and cylindrical TE011 cavity for aqueous samples at 94GHz

Jason W. Sidabras; Richard R. Mett; Wojciech Froncisz; Theodore G. Camenisch; James R. Anderson; James S. Hyde

A loop-gap resonator (LGR) and a cylindrical TE(011) cavity resonator for use at W band, 94 GHz, have been designed and characterized using the Ansoft (Pittsburgh, PA) high frequency structure simulator (HFSS; Version 10.0). Field modulation penetration was analyzed using Ansoft MAXWELL 3D (Version 11.0). Optimizing both resonators to the same sample sizes shows that EPR signal intensities of the LGR and TE(011) are similar. The 3 dB bandwidth of the LGR, on the order of 1 GHz, is a new advantage for high frequency experiments. Ultraprecision electric discharge machining (EDM) was used to fabricate the resonators from silver. The TE(011) cavity has slots that are cut into the body to allow penetration of 100 kHz field modulation. The resonator body is embedded in graphite, also cut by EDM techniques, for a combination of reasons that include (i) reduced microwave leakage and improved TE(011) mode purity, (ii) field modulation penetration, (iii) structural support for the cavity body, and (iv) machinability by EDM. Both resonators use a slotted iris. Variable coupling is provided by a three-stub tuning element. A collet system designed to hold sample tubes has been implemented, increasing repeatability of sample placement and reducing sample vibration noise. Initial results include multiquantum experiments up to 9Q using the LGR to examine 1 mM 2,2,6,6-tetramethylpiperidine-1-oxyl (TEMPO) in aqueous solution at room temperature and field modulation experiments using the TE(011) cavity to obtain an EPR spectrum of 1 microM TEMPO.


Review of Scientific Instruments | 2008

Dielectric microwave resonators in TE011 cavities for electron paramagnetic resonance spectroscopy

Richard R. Mett; Jason W. Sidabras; Iryna S. Golovina; James S. Hyde

The coupled system of the microwave cylindrical TE(011) cavity and the TE(01delta) dielectric modes has been analyzed in order to determine the maximum achievable resonator efficiency parameter of a dielectric inserted into a cavity, and whether this value can exceed that of a dedicated TE(01delta) mode dielectric resonator. The frequency, Q value, and resonator efficiency parameter Lambda for each mode of the coupled system were calculated as the size of the dielectric was varied. Other output parameters include the relative field magnitudes and phases. Two modes are found: one with fields in the dielectric parallel to the fields in the cavity center and the other with antiparallel fields. Results closely match those from a computer program that solves Maxwells equations by finite element methods. Depending on the relative natural resonance frequencies of the cavity and dielectric, one mode has a higher Q value and correspondingly lower Lambda than the other. The mode with the higher Q value is preferentially excited by a coupling iris or loop in or near the cavity wall. However, depending on the frequency separation between modes, either can be excited in this way. A relatively narrow optimum is found for the size of the insert that produces maximum signal for both modes simultaneously. It occurs when the self-resonance frequencies of the two resonators are nearly equal. The maximum signal is almost the same as that of the dedicated TE(01delta) mode dielectric resonator alone, Lambda congruent with40 G/W(1/2) at X-band for a KTaO(3) crystal. The cavity is analogous to the second stage of a two-stage coupler. In general, there is no electron paramagnetic resonance (EPR) signal benefit by use of a second stage. However, there is a benefit of convenience. A properly designed sample-mounted resonator inserted into a cavity can give EPR signals as large as what one would expect from the dielectric resonator alone.


Health Physics | 2012

ELECTRON PARAMAGNETIC RESONANCE DOSIMETRY FOR A LARGE-SCALE RADIATION INCIDENT

Harold M. Swartz; Ann Barry Flood; Benjamin B. Williams; Ruhong Dong; Steven G. Swarts; Xiaoming He; Oleg Y. Grinberg; Jason W. Sidabras; Eugene Demidenko; Jiang Gui; David J. Gladstone; Lesley A. Jarvis; Maciej M. Kmiec; Kyo Kobayashi; Piotr Lesniewski; Stephen D.P. Marsh; Thomas P. Matthews; Roberto J. Nicolalde; Patrick M. Pennington; Timothy Raynolds; Ildar Salikhov; Dean E. Wilcox; Bassem I. Zaki

Abstract With possibilities for radiation terrorism and intensified concerns about nuclear accidents since the recent Fukushima Daiichi event, the potential exposure of large numbers of individuals to radiation that could lead to acute clinical effects has become a major concern. For the medical community to cope with such an event and avoid overwhelming the medical care system, it is essential to identify not only individuals who have received clinically significant exposures and need medical intervention but also those who do not need treatment. The ability of electron paramagnetic resonance to measure radiation-induced paramagnetic species, which persist in certain tissues (e.g., teeth, fingernails, toenails, bone, and hair), has led to this technique becoming a prominent method for screening significantly exposed individuals. Although the technical requirements needed to develop this method for effective application in a radiation event are daunting, remarkable progress has been made. In collaboration with General Electric and through funding committed by the Biomedical Advanced Research and Development Authority, electron paramagnetic resonance tooth dosimetry of the upper incisors is being developed to become a Food and Drug Administration-approved and manufacturable device designed to carry out triage for a threshold dose of 2 Gy. Significant progress has also been made in the development of electron paramagnetic resonance nail dosimetry based on measurements of nails in situ under point-of-care conditions, and in the near future this may become a second field-ready technique. Based on recent progress in measurements of nail clippings, it is anticipated that this technique may be implementable at remotely located laboratories to provide additional information when the measurements of dose on-site need to be supplemented. The authors conclude that electron paramagnetic resonance dosimetry is likely to be a useful part of triage for a large-scale radiation incident.


Journal of Magnetic Resonance | 2011

Detection of undistorted continuous wave (CW) electron paramagnetic resonance (EPR) spectra with non-adiabatic rapid sweep (NARS) of the magnetic field

Aaron W. Kittell; Theodore G. Camenisch; Joseph J. Ratke; Jason W. Sidabras; James S. Hyde

A continuous wave (CW) electron paramagnetic resonance (EPR) spectrum is typically displayed as the first harmonic response to the application of 100 kHz magnetic field modulation, which is used to enhance sensitivity by reducing the level of 1/f noise. However, magnetic field modulation of any amplitude causes spectral broadening and sacrifices EPR spectral intensity by at least a factor of two. In the work presented here, a CW rapid-scan spectroscopic technique that avoids these compromises and also provides a means of avoiding 1/f noise is developed. This technique, termed non-adiabatic rapid sweep (NARS) EPR, consists of repetitively sweeping the polarizing magnetic field in a linear manner over a spectral fragment with a small coil at a repetition rate that is sufficiently high that receiver noise, microwave phase noise, and environmental microphonics, each of which has 1/f characteristics, are overcome. Nevertheless, the rate of sweep is sufficiently slow that adiabatic responses are avoided and the spin system is always close to thermal equilibrium. The repetitively acquired spectra from the spectral fragment are averaged. Under these conditions, undistorted pure absorption spectra are obtained without broadening or loss of signal intensity. A digital filter such as a moving average is applied to remove high frequency noise, which is approximately equivalent in bandwidth to use of an integrating time constant in conventional field modulation with lock-in detection. Nitroxide spectra at L- and X-band are presented.


Applied Magnetic Resonance | 2007

Uniform radio frequency fields in loop-gap resonators for EPR spectroscopy

Richard R. Mett; Jason W. Sidabras; James S. Hyde

At high frequencies, e.g., Q- and W-bands, it is advantageous to make the axial length of loop-gap resonators (LGRs) at least as long as a free-space wavelength. The opposite scaling of capacitance and inductance with LGR length suggests that the length of an LGR can be increased without limit, with the axial radio frequency (rf) field profiles and resonance frequency independent of length. This scaling is accurate for resonator dimensions much less than one free-space wavelength. When the resonator length approaches one-tenth of a free-space wavelength, the rf field uniformity degrades. From one-tenth to one free-space wavelength, computer simulations and experimental measurements show that the axial magnetic field energy density profile is peaked in the center of the LGR, gradually decreases from 25 to 50% at a distance one radius from the end, and rapidly there-after. The nonuniformity is of two types. One type, in the vicinity of one radius of the end, is caused by the flaring of the field as it curves from the central loop to the end region, into the larger return loop(s). The other type, in the central part of the resonator, is caused by impedance mismatch at the ends of the LGR. The LGR may be viewed as a strongly reentrant (ridge) waveguide nearly open at both ends and supporting a standing wave. A transmission line model relates the central nonuniformity to the fringing capacitance and inductance at the ends of the resonator. This nonuniformity can be eliminated in several ways including modifying the ends of the LGR by adding a small metal bridge or a dielectric ring. These uniformity trimming elements increase the fringing capacitance and/or decrease the fringing inductance. With trimmed ends, LGRs can be made many free-space wavelengths long. The maximum resonator length is determined by the proximity in frequency of the fundamental LGR mode to the next highest frequency mode as well as the quality factor. Results of this theory are compared and conformed with finite-element simulations. This theory connects the uniform LGR with the uniform field cavity resonators previously introduced by this laboratory.


Radiation Protection Dosimetry | 2014

Development and validation of an ex vivo electron paramagnetic resonance fingernail biodosimetric method.

Xiaoming He; Steven G. Swarts; Eugene Demidenko; Ann Barry Flood; Oleg Y. Grinberg; Jiang Gui; Michael Mariani; Stephen D.P. Marsh; Andres E. Ruuge; Jason W. Sidabras; Dmitry Tipikin; Dean E. Wilcox; Harold M. Swartz

There is an imperative need to develop methods that can rapidly and accurately determine individual exposure to radiation for screening (triage) populations and guiding medical treatment in an emergency response to a large-scale radiological/nuclear event. To this end, a number of methods that rely on dose-dependent chemical and/or physical alterations in biomaterials or biological responses are in various stages of development. One such method, ex vivo electron paramagnetic resonance (EPR) nail dosimetry using human nail clippings, is a physical biodosimetry technique that takes advantage of a stable radiation-induced signal (RIS) in the keratin matrix of fingernails and toenails. This dosimetry method has the advantages of ubiquitous availability of the dosimetric material, easy and non-invasive sampling, and the potential for immediate and rapid dose assessment. The major challenge for ex vivo EPR nail dosimetry is the overlap of mechanically induced signals and the RIS. The difficulties of analysing the mixed EPR spectra of a clipped irradiated nail were addressed in the work described here. The following key factors lead to successful spectral analysis and dose assessment in ex vivo EPR nail dosimetry: (1) obtaining a thorough understanding of the chemical nature, the decay behaviour, and the microwave power dependence of the EPR signals, as well as the influence of variation in temperature, humidity, water content, and O₂ level; (2) control of the variability among individual samples to achieve consistent shape and kinetics of the EPR spectra; (3) use of correlations between the multiple spectral components; and (4) use of optimised modelling and fitting of the EPR spectra to improve the accuracy and precision of the dose estimates derived from the nail spectra. In the work described here, two large clipped nail datasets were used to test the procedures and the spectral fitting model of the results obtained with it. A 15-donor nail set with 90 nail samples from 15 donors was used to validate the sample handling and spectral analysis methods that have been developed but without the interference of a native background signal. Good consistency has been obtained between the actual RIS and the estimated RIS computed from spectral analysis. In addition to the success in RIS estimation, a linear dose response has also been achieved for all individuals in this study, where the radiation dose ranges from 0 to 6 Gy. A second 16-donor nail set with 96 nail samples was used to test the spectral fitting model where the background signal was included during the fitting of the clipped nail spectra data. Although the dose response for the estimated and actual RIS calculated in both donor nail sets was similar, there was an increased variability in the RIS values that was likely due to the variability in the background signal between donors. Although the current methods of sample handling and spectral analysis show good potential for estimating the RIS in the EPR spectra of nail clippings, there is a remaining degree of variability in the RIS estimate that needs to be addressed; this should be achieved by identifying and accounting for demographic sources of variability in the background nail signal and the composition of the nail matrix.


Health Physics | 2010

Surface loop resonator design for in vivo EPR tooth dosimetry using finite element analysis.

Jennifer D. Pollock; Benjamin B. Williams; Jason W. Sidabras; Oleg Y. Grinberg; Ildar Salikhov; Piotr Lesniewski; Maciej M. Kmiec; Harold M. Swartz

Finite element analysis is used to evaluate and design L-band surface loop resonators for in vivo electron paramagnetic resonance (EPR) tooth dosimetry. This approach appears to be practical and useful for the systematic examination and evaluation of resonator configurations to enhance the precision of dose estimates. The effects of loop positioning in the mouth are examined, and it is shown that the sensitivity to loop position along a row of molars is decreased as the loop is moved away from the teeth.


Biophysical Journal | 2009

EPR of Cu2+ Prion Protein Constructs at 2 GHz Using the g⊥ Region to Characterize Nitrogen Ligation

James S. Hyde; Brian Bennett; Eric D. Walter; Glenn L. Millhauser; Jason W. Sidabras; William E. Antholine

A double octarepeat prion protein construct, which has two histidines, mixed with copper sulfate in a 3:2 molar ratio provides at most three imidazole ligands to each copper ion to form a square-planar Cu(2+) complex. This work is concerned with identification of the fourth ligand. A new (to our knowledge) electron paramagnetic resonance method based on analysis of the intense features of the electron paramagnetic resonance spectrum in the g( perpendicular) region at 2 GHz is introduced to distinguish between three and four nitrogen ligands. The methodology was established by studies of a model system consisting of histidine imidazole ligation to Cu(2+). In this spectral region at 2 GHz (S-band), g-strain and broadening from the possible rhombic character of the Zeeman interaction are small. The most intense line is identified with the M(I) = +1/2 extra absorption peak. Spectral simulation demonstrated that this peak is insensitive to cupric A(x) and A(y) hyperfine interaction. The spectral region to the high-field side of this peak is uncluttered and suitable for analysis of nitrogen superhyperfine couplings to determine the number of nitrogens. The spectral region to the low-field side of the intense extra absorption peak in the g( perpendicular) part of the spectrum is sensitive to the rhombic distortion parameters A(x) and A(y). Application of the method to the prion protein system indicates that two species are present and that the dominant species contains four nitrogen ligands. A new loop-gap microwave resonator is described that contains approximately 1 mL of frozen sample.


Journal of Magnetic Resonance | 2013

Moving Difference (MDIFF) Non-adiabatic Rapid Sweep (NARS) EPR of Copper(II)

James S. Hyde; Brian Bennett; Aaron W. Kittell; Jason M. Kowalski; Jason W. Sidabras

Non-adiabatic rapid sweep (NARS) EPR spectroscopy has been introduced for application to nitroxide-labeled biological samples (Kittell et al., 2011). Displays are pure absorption, and are built up by acquiring data in spectral segments that are concatenated. In this paper we extend the method to frozen solutions of copper-imidazole, a square planar copper complex with four in-plane nitrogen ligands. Pure absorption spectra are created from concatenation of 170 5-gauss segments spanning 850 G at 1.9 GHz. These spectra, however, are not directly useful since nitrogen superhyperfine couplings are barely visible. Application of the moving difference (MDIFF) algorithm to the digitized NARS pure absorption spectrum is used to produce spectra that are analogous to the first harmonic EPR. The signal intensity is about four times higher than when using conventional 100 kHz field modulation, depending on line shape. MDIFF not only filters the spectrum, but also the noise, resulting in further improvement of the SNR for the same signal acquisition time. The MDIFF amplitude can be optimized retrospectively, different spectral regions can be examined at different amplitudes, and an amplitude can be used that is substantially greater than the upper limit of the field modulation amplitude of a conventional EPR spectrometer, which improves the signal-to-noise ratio of broad lines.

Collaboration


Dive into the Jason W. Sidabras's collaboration.

Top Co-Authors

Avatar

James S. Hyde

Medical College of Wisconsin

View shared research outputs
Top Co-Authors

Avatar

Richard R. Mett

Medical College of Wisconsin

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

James R. Anderson

Medical College of Wisconsin

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Robert A. Strangeway

Medical College of Wisconsin

View shared research outputs
Top Co-Authors

Avatar

Witold K. Subczynski

Medical College of Wisconsin

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge