Ophthalmologica | 2013

Fluidics in a dual pneumatic ultra high-speed vitreous cutter system.

Bruno Diniz; Ramiro Ribeiro; Rodrigo A. Brant Fernandes; Jaw-Chyng Lormen Lue; Anderson Teixeira; Mauricio Maia; Mark S. Humayun

Background: Dual pneumatic systems use two separate air line tubes to open and close the cutter and can achieve high cut rates. The purpose of this study is to evaluate the influence of gauge size, cut rate and aspiration on the flow rate performance of ultra high-speed cutters operated with a commercially available dual pneumatic vitrectomy system. Methods: Analysis of a high-speed video was used to determine duty cycle. Flow rates from 20-, 23- and 25-gauge cutters were calculated in predetermined conditions of aspiration levels and cut rates; water and fresh porcine vitreous samples were studied. Results: For all three gauges of cutters, the duty cycle and water flow showed an inverse correlation with increasing cut rates and a direct correlation with increasing aspiration levels (p < 0.05). Vitreous flow rates from all gauges increased with increasing aspiration and cut rates (p < 0.05). Conclusion: Larger gauges of the cutters as well as higher aspiration and cut rate levels resulted in improvement of the vitreous flow rates. A good understanding of the different flow rate settings is essential for the surgeon and optimizes the safety of surgical procedures.


Investigative Ophthalmology & Visual Science | 2010

An experimental protocol of the model to quantify traction applied to the retina by vitreous cutters.

Anderson Teixeira; Lawrence Chong; Naoki Matsuoka; Luis Arana; Jaw-Chyng Lormen Lue; Matthew Mccormick; Ralph Kerns; Prashant Bhadri; Mark S. Humayun

PURPOSE The purpose of this study was to use a novel method to quantify the traction applied to the retina during vitrectomy. METHODS Five 20-gauge electric cutters were used. Fresh porcine eyes were positioned in a specially developed holder and transfixed to the retinal layers with a microwire, and the other end was fixed to the load cell of a strain gauge. The cutter to be assessed was introduced into the eye by a micromanipulator at a 45 degrees angle adjacent to the retina. The traction force was evaluated when the cutter was at 3 and 5 mm from the retina. As control, the experiment was repeated in eyes filled with water, and the results were compared to those when the eyes had vitreous gel. RESULTS Results from the eyes with vitreous gel indicate that retinal traction increased with increasing aspiration vacuum (7.90 dyn for each 100 mm Hg increased; P < 0.05) and proximity to the retina (2.17 dyn; P < 0.05) and decreased with increasing cut rate (2.51 dyn for each 500 cuts per minute increased; P < 0.05). In all eyes filled with water, traction was not observed. CONCLUSIONS The present study establishes a new reproducible technique to quantify vitreoretinal traction during vitrectomy and demonstrates that the effects of aspiration, distance from the retina, and cut rate are crucial factors in the amount of retinal traction created by vitreous cutters.


British Journal of Ophthalmology | 2010

Novel method to quantify traction in a vitrectomy procedure

Anderson Teixeira; Lawrence Chong; Naoki Matsuoka; Adrian P. Rowley; Jaw-Chyng Lormen Lue; Matthew Mccormick; Ralph Kerns; Mark S. Humayun

Aim To report a novel method to quantify traction applied to the retina using vitreous cutters during pars plana vitrectomy. Methods Fresh porcine eyes were positioned in a specially developed holder and transfixed to the retinal layers with a wire and the other end fixed to the load cell of a strain gauge. Five separate 20-gauge electrical drive mechanism vitrectors were introduced into the eye at a 45° angle and positioned at a distance of either 3 or 5 mm from the retina. Data from the strain gauge were acquired and the traction force computed. Results The analysis revealed that the vitreoretinal traction increased by 7.90 dynes for each 100 mm Hg increase in vacuum (p<0.05). The traction forces decreased by 2.51 dynes for each 500 cuts per minute increased (p<0.05) and the traction force increased by 2.17 dynes at 3 mm compared with 5 mm (p<0.05). Conclusion The traction was directly proportional to the aspiration vacuum and inversely proportional to the cut rate. The cutter traction force increased with proximity to the retina.


Retina-the Journal of Retinal and Vitreous Diseases | 2013

Analysis of a 23-gauge ultra high-speed cutter with duty cycle control.

Bruno Diniz; Rodrigo A. Brant Fernandes; Ramiro Ribeiro; Jaw-Chyng Lormen Lue; Anderson Teixeira; Octaviano Magalhães; Mauricio Maia; Mark S. Humayun

Purpose: The purpose of the study was to determine the performance of dual pneumatic ultra high–speed 23-gauge cutters operated with variable duty cycle (DC) settings. Methods: Frame-by-frame analysis of high-speed video was used to determine the DC in core, 50–50, and shave modes. Using three cutters at various cycles per minute and aspiration levels, mass of water or vitreous removed from a vial was measured within a specified time period. Average flow rates were calculated for each aspiration level and cut rate with the different DC options. Results: The DC increased with increasing cut rate in the shave mode was relatively stable in the 50–50 mode and decreased for the core mode. The DC converged at 5,000 cycles per minute for the 3 different modes. Water flow curves followed the DC variation. Vitreous flow rates for all the DC modes increased with increasing cut rates and peaked at 5,000 cycles per minute (P < 0.05). The results of the 50–50 mode, which had isolated the DC influence, showed that increasing aspiration and/or cut rate independently increased the vitreous flow rate. Conclusion: Progressive values of aspiration and/or cut rate increase the vitreous flow rate, independently of the DC. The DC control also has an important effect on the vitreous flow, but this effect was reduced at high cut rates because of convergence of the DC modes.


BioMed Research International | 2014

Comparison of Reaction Response Time between Hand and Foot Controlled Devices in Simulated Microsurgical Testing

Marcel Pfister; Jaw-Chyng Lormen Lue; Francisco Rosa Stefanini; Paulo Falabella; Laurie Dustin; Michael J. Koss; Mark S. Humayun

Purpose. We hypothesized that reaction times (RTs) for a switch release are faster for hand-controlled than for foot-controlled switches for physiological and anatomical reasons (e.g., nerve conduction speed). The risk of accidental trauma could be reduced if the surgeon reacted quicker and therefore improve the surgical outcome. Method. We included 47 medical professionals at USC. Demographics and handedness were recorded. Under a microscope, a simple reaction time test was performed, testing all extremities multiple times in a random order. Additionally, a subjective questionnaire was administered. Results. The mean RTs for hands are 318.24 ms ± 51.13 and feet 328.69 ± 48.70. The comparison of hand versus foot showed significant shorter RTs for the hand (P = 0.025). Partially significant differences between and within the experience level groups could be demonstrated by level of education (LE) and microscopic surgeries/week (MSW) (P = 0.57–0.02). In the subjective questionnaire, 91.5% (n = 43/47) of test subjects prefer to use hand controls. Conclusion. Our data show that the RT for hands is faster than feet. Similarly the subjective questionnaire showed a greater preference for hand actuation. This data suggest a hand-controlled ophthalmic instrument might have distinct advantages; however, clinical correlation is required.


Retina-the Journal of Retinal and Vitreous Diseases | 2016

INTRAOCULAR PRESSURE CHANGES DURING VITRECTOMY USING CONSTELLATION VISION SYSTEM'S INTRAOCULAR PRESSURE CONTROL FEATURE.

Paulo Falabella; Francisco Rosa Stefanini; Jaw-Chyng Lormen Lue; Marcel Pfister; Jahlyn Reyes-Mckinley; Michael J. Koss; Anderson Teixeira; Paulo Schor; Mark S. Humayun

Purpose: To evaluate intraocular pressure (IOP) changes during experimental vitrectomy and the efficacy of Constellation Vision Systems IOP control (IOPc) feature in reestablishing baseline pressure. Methods: Using a pressure transducer in freshly enucleated porcine eyes, a broad range of parameters (baseline pressures, aspiration levels, and cut rates) were tested with 23- and 25-gauge probes and IOPc turned ON versus OFF. Results: IOPc turned ON was significantly more effective than IOPc turned OFF in controlling IOP drop and stabilizing pressure during vitrectomy using a wide range of baseline pressures (20–70 mmHg). The 23-gauge system consistently presented a reduced drop from baseline compared with the 25-gauge system. The overall average drop for the 23- and 25-gauge systems was 12.79 mmHg and 21.17 mmHg, respectively. Both gauge sizes reestablished baseline pressure approximately 1.6 seconds after the initial pressure drop generated at the beginning of aspiration. A peak of IOP (overshooting) was observed when the pressure was returning to baseline using both 23- and 25-gauge systems. Conclusion: Using IOPc feature turned ON, 23- and 25-gauge probes were effective in reestablishing and sustaining baseline infusion pressures, although 23-gauge probes showed less IOP fluctuation than did 25-gauge probes.


Frontiers in Optics | 2007

Intraocular camera for retinal prostheses: Design constraints based on visual psychophysics

Noelle R. B. Stiles; Michelle C. Hauer; Pamela Lee; Patrick J. Nasiatka; Jaw-Chyng Lormen Lue; James D. Weiland; Mark S. Humayun; Armand R. Tanguay

Optical system design constraints for an intraocular camera are determined by visual psychophysics techniques, including pixellation limits adequate for navigation and object identification, optimal pre- and post-pixellation blurring, and the elimination of gridding artifacts.


Retina-the Journal of Retinal and Vitreous Diseases | 2017

EFFECTS OF A MODIFIED VITRECTOMY PROBE IN SMALL-GAUGE VITRECTOMY: An Experimental Study on the Flow and on the Traction Exerted on the Retina

Stanislao Rizzo; Gualtiero Fantoni; Giovanni de Santis; Jaw-Chyng Lormen Lue; Jonathan Ciampi; M. Palla; Federica Genovesi Ebert; Alfonso Savastano; Carmelo De Maria; Giovanni Vozzi; Rodrigo A. Brant Fernandes; Francesco Faraldi; Giuseppe Criscenti

Purpose: Thorough this experimental study, the physic features of a modified 23-gauge vitrectomy probe were evaluated in vitro. Methods: A modified vitrectomy probe to increase vitreous outflow rate with a small-diameter probe, that also minimized tractional forces on the retina, was created and tested. The “new” probe was created by drilling an opening into the inner duct of a traditional 23-gauge probe with electrochemical or electrodischarge micromachining. Both vitreous outflow and tractional forces on the retina were examined using experimental models of vitreous surgery. Results: The additional opening allowed the modified probe to have a cutting rate of 5,000 cuts per minute, while sustaining an outflow approximately 45% higher than in conventional 23-gauge probes. The modified probe performed two cutting actions per cycle, not one, as in standard probes. Because tractional force is influenced by cutting rate, retinal forces were 2.2 times lower than those observed with traditional cutters. Conclusion: The modified probe could be useful in vitreoretinal surgery. It allows for faster vitreous removal while minimizing tractional forces on the retina. Moreover, any available probe can be modified by creating a hole in the inner duct.


BioMed Research International | 2008

Bio-inspired microsystem for robust genetic assay recognition.

Jaw-Chyng Lormen Lue; Wai-Chi Fang

A compact integrated system-on-chip (SoC) architecture solution for robust, real-time, and on-site genetic analysis has been proposed. This microsystem solution is noise-tolerable and suitable for analyzing the weak fluorescence patterns from a PCR prepared dual-labeled DNA microchip assay. In the architecture, a preceding differential logarithm stage is designed for effectively computing the logarithm of the normalized input fluorescence signals. A posterior VISI artificial neural network (ANN) processor chip is used for analyzing the processed signals from the differential logarithm stage. A single-channel logarithmic circuit was fabricated and characterized. A prototype ANN chip with winner-take-all (WTA) function was designed, fabricated, and tested. An ANN learning algorithm using a novel sigmoid-logarithmic transfer function based on the error backpropagation (BP) algorithm is proposed for robustly recognizing low intensity patterns. Our results show the trained new ANN can recognize low fluorescence patterns better than the ANN using the conventional sigmoid function.


ieee/nih life science systems and applications workshop | 2007

Bio-inspired miniaturized instrument in system-on-chip for robust on-site biomarker recognition

Wai-Chi Fang; Jaw-Chyng Lormen Lue

A compact integrated system-on-chip (SoC) architecture solution for robust, real-time, and on-site genetic analysis and biomarker recognition has been developed. This microsystem solution is noise-tolerable and suitable for analyzing the weak fluorescence patterns from a PCR prepared dual-labeled DNA microchip assay. In the architecture, a preceding VLSI differential logarithm microchip is designed for effectively computing the logarithm of the normalized input fluorescence signals. A posterior VLSI artificial neural network (ANN) processor chip is used for analyzing the processed signals from the differential logarithm stage. A single-channel logarithmic circuit was fabricated and characterized. A prototype ANN chip with unsupervised winner-take-all (WTA) function was designed, fabricated, and tested. An ANN learning algorithm using a novel sigmoid-logarithmic transfer function based on the supervised backpropagation (BP) algorithm is proposed for robustly recognizing low intensity patterns. Our results show the trained new ANN can recognize low fluorescence patterns better than an ANN using the conventional sigmoid function.

Collaboration


Dive into the Jaw-Chyng Lormen Lue's collaboration.

Top Co-Authors

Avatar

Mark S. Humayun

University of Southern California

View shared research outputs
Top Co-Authors

Avatar

Matthew Mccormick

University of Southern California

View shared research outputs
Top Co-Authors

Avatar

Ralph Kerns

University of Southern California

View shared research outputs
Top Co-Authors

Avatar

Prashant Bhadri

University of Southern California

View shared research outputs
Top Co-Authors

Avatar

Anderson Teixeira

Federal University of São Paulo

View shared research outputs
Top Co-Authors

Avatar

Wai-Chi Fang

California Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Mark Humayun

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Paulo Falabella

University of Southern California

View shared research outputs
Top Co-Authors

Avatar

Rodrigo A. Brant Fernandes

University of Southern California

View shared research outputs
Researchain Logo
Decentralizing Knowledge