Featured researches published by Jaydev K. Dave.


Ultrasonic Imaging | 2011

Subharmonic Contrast Microbubble Signals for Noninvasive Pressure Estimation under Static and Dynamic Flow Conditions

Valgerdur G. Halldorsdottir; Jaydev K. Dave; Lauren M. Leodore; John R. Eisenbrey; Suhyun Park; Anne L. Hall; Kai E. Thomenius; Flemming Forsberg

Our group has proposed the concept of subharmonic aided pressure estimation (SHAPE) utilizing microbubble-based ultrasound contrast agent signals for the noninvasive estimation of hydrostatic blood pressures. An experimental system for in vitro SHAPE was constructed based on two single-element transducers assembled confocally at a 60° angle to each other. Changes in the first, second and subharmonic amplitudes of five different ultrasound contrast agents were measured in vitro at static hydrostatic pressures from 0–186 mmHg, acoustic pressures from 0.35–0.60 MPa peak-to-peak and frequencies of 2.5–6.6 MHz. The most sensitive agent and optimal parameters for SHAPE were determined using linear regression analysis and implemented on a Logiq 9 scanner (GE Healthcare, Milwaukee, WI). This implementation of SHAPE was then tested under dynamic-flow conditions and compared to pressure-catheter measurements. Over the pressure range studied, the first and second harmonic amplitudes reduced approximately 2 dB for all contrast agents. Over the same pressure range, the subharmonic amplitudes decreased by 9–14 dB and excellent linear regressions were achieved with the hydrostatic pressure variations (r2 = 0.98, p < 0.001). Optimal sensitivity was achieved at a transmit frequency of 2.5 MHz and acoustic pressure of 0.35 MPa using Sonazoid (GE Healthcare, Oslo, Norway). A Logiq 9 scanner was modified to implement SHAPE on a convex transducer with a frequency range from 1.5–4.5 MHz and acoustic pressures from 0–3.34 MPa. Results matched the pressure catheter (r2 = 0.87). In conclusion, subharmonic contrast signals are a good indicator of hydrostatic pressure. Out of the five ultrasound contrast agents tested, Sonazoid was the most sensitive for subharmonic pressure estimation. Real-time SHAPE has been implemented on a commercial scanner and offers the possibility of allowing pressures in the heart and elsewhere to be obtained noninvasively.


Ultrasonics | 2011

Simultaneous grayscale and subharmonic ultrasound imaging on a modified commercial scanner

John R. Eisenbrey; Jaydev K. Dave; Valgerdur G. Halldorsdottir; Daniel A. Merton; Priscilla Machado; Ji-Bin Liu; Cynthia Miller; José M. Gonzalez; Suhyun Park; Scott Dianis; Carl L. Chalek; Kai E. Thomenius; Daniel B. Brown; Victor J. Navarro; Flemming Forsberg

OBJECTIVE To demonstrate the feasibility of simultaneous dual fundamental grayscale and subharmonic imaging on a modified commercial scanner. MOTIVATION The ability to generate signals at half the insonation frequency is exclusive to ultrasound contrast agents (UCA). Thus, subharmonic imaging (SHI; transmitting at f(0) and receiving at f(0)/2) provides improved visualization of UCA within the vasculature via suppression of the surrounding tissue echoes. While this capability has proven useful in a variety of clinical applications, the SHI suppression of surrounding tissue landmarks (which are needed for sonographic navigation) also limits it use as a primary imaging modality. In this paper we present results using a commercial ultrasound scanner modified to allow imaging in both grayscale (f(0)=4.0 MHz) and SHI (f(0)=2.5 MHz, f(0)/2=1.25 MHz) modes in real time. METHODS A Logiq 9 ultrasound scanner (GE Healthcare, Milwaukee, WI) with a 4C curvilinear probe was modified to provide this capability. Four commercially available UCA (Definity, Lantheus Medical Imaging, North Billerica, MA; Optison, GE Healthcare, Princeton, NJ; SonoVue, Bracco Imaging, Milan, Italy; and Sonazoid, GE Healthcare, Oslo, Norway) were all investigated in vitro over an acoustic output range of 3.34 MPa. In vivo the subharmonic response of Sonazoid was investigated in the portal veins of four canines (open abdominal cavity) and four patients with suspected portal hypertension. RESULTS In vitro, the four UCA showed an average maximum subharmonic amplitude of 44.1±5.4 dB above the noise floor with a maximum subharmonic amplitude of 48.6±1.6 dB provided by Sonazoid. The average in vivo maximum signal above the noise floor from Sonazoid was 20.8±2.3 dB in canines and 33.9±5.2 dB in humans. Subharmonic amplitude as a function of acoustic output in both groups matched the S-curve behavior of the agent observed in vitro. The dual grayscale imaging provided easier sonographic navigation, while the degree of tissue suppression in SHI mode varied greatly on a case by case basis. CONCLUSIONS These results demonstrate the feasibility of dual grayscale and SHI on a modified commercial scanner. The ability to simultaneously visualize both imaging modes in real time should improve the applicability of SHI as a future primary clinical imaging modality.


Journal of Ultrasound in Medicine | 2011

Parametric Imaging Using Subharmonic Signals From Ultrasound Contrast Agents in Patients With Breast Lesions

John R. Eisenbrey; Jaydev K. Dave; Daniel A. Merton; Juan P. Palazzo; Anne L. Hall; Flemming Forsberg

Parametric maps showing perfusion of contrast media can be useful tools for characterizing lesions in breast tissue. In this study we show the feasibility of parametric subharmonic imaging (SHI), which allows imaging of a vascular marker (the ultrasound contrast agent) while providing near complete tissue suppression. Digital SHI clips of 16 breast lesions from 14 women were acquired. Patients were scanned using a modified LOGIQ 9 scanner (GE Healthcare, Waukesha, WI) transmitting/receiving at 4.4/2.2 MHz. Using motion‐compensated cumulative maximum intensity (CMI) sequences, parametric maps were generated for each lesion showing the time to peak (TTP), estimated perfusion (EP), and area under the time‐intensity curve (AUC). Findings were grouped and compared according to biopsy results as benign lesions (n = 12, including 5 fibroadenomas and 3 cysts) and carcinomas (n = 4). For each lesion CMI, TTP, EP, and AUC parametric images were generated. No significant variations were detected with CMI (P = .80), TTP (P = .35), or AUC (P = .65). A statistically significant variation was detected for the average pixel EP (P = .002). Especially, differences were seen between carcinoma and benign lesions (mean ± SD, 0.10 ± 0.03 versus 0.05 ± 0.02 intensity units [IU]/s; P = .0014) and between carcinoma and fibroadenoma (0.10 ± 0.03 versus 0.04 ± 0.01 IU/s; P = .0044), whereas differences between carcinomas and cysts were found to be nonsignificant. In conclusion, a parametric imaging method for characterization of breast lesions using the high contrast to tissue signal provided by SHI has been developed. While the preliminary sample size was limited, results show potential for breast lesion characterization based on perfusion flow parameters.


Academic Radiology | 2012

Three-Dimensional Subharmonic Ultrasound Imaging In Vitro and In Vivo

John R. Eisenbrey; Anush Sridharan; Priscilla Machado; Hongjia Zhao; Valgerdur G. Halldorsdottir; Jaydev K. Dave; Ji-Bin Liu; Suhyun Park; Scott Dianis; Kirk Wallace; Kai E. Thomenius; Flemming Forsberg

RATIONALE AND OBJECTIVES Although contrast-enhanced ultrasound imaging techniques such as harmonic imaging (HI) have evolved to reduce tissue signals using the nonlinear properties of the contrast agent, levels of background suppression have been mixed. Subharmonic imaging (SHI) offers near complete tissue suppression by centering the receive bandwidth at half the transmitting frequency. The aims of this study were to demonstrate the feasibility of three-dimensional (3D) SHI and to compare it to 3D HI. MATERIALS AND METHODS Three-dimensional HI and SHI were implemented on a Logiq 9 ultrasound scanner with a 4D10L probe. Four-cycle SHI was implemented to transmit at 5.8 MHz and receive at 2.9 MHz, while two-cycle HI was implemented to transmit at 5 MHz and receive at 10 MHz. The ultrasound contrast agent Definity was imaged within a flow phantom and the lower pole of two canine kidneys in both HI and SHI modes. Contrast-to-tissue ratios and rendered images were compared offline. RESULTS SHI resulted in significant improvement in contrast-to-tissue ratios relative to HI both in vitro (12.11 ± 0.52 vs 2.67 ± 0.77, P< .001) and in vivo (5.74 ± 1.92 vs 2.40 ± 0.48, P = .04). Rendered 3D subharmonic images provided better tissue suppression and a greater overall view of vessels in a flow phantom and canine renal vasculature. CONCLUSIONS The successful implementation of SHI in 3D allows imaging of vascular networks over a heterogeneous sample volume and should improve future diagnostic accuracy. Additionally, 3D SHI provides improved contrast-to-tissue ratios relative to 3D HI.


Jacc-cardiovascular Imaging | 2012

Noninvasive LV Pressure Estimation Using Subharmonic Emissions From Microbubbles

Jaydev K. Dave; Valgerdur G. Halldorsdottir; John R. Eisenbrey; Joel S. Raichlen; Ji-Bin Liu; Maureen E. McDonald; Kris Dickie; Shumin Wang; Corina Leung; Flemming Forsberg

To develop a new noninvasive approach to quantify left ventricular (LV) pressures using subharmonic emissions from microbubbles, an ultrasound scanner was used in pulse inversion grayscale mode; unprocessed radiofrequency data were obtained with pulsed wave Doppler from the aorta and/or LV during Sonazoid infusion. Subharmonic data (in dB) were extracted and processed. Calibration factor (mm Hg/dB) from the aortic pressure was used to estimate LV pressures. Errors ranged from 0.19 to 2.50 mm Hg when estimating pressures using the aortic calibration factor, and were higher (0.64 to 8.98 mm Hg) using a mean aortic calibration factor. Subharmonic emissions from ultrasound contrast agents have the potential to noninvasively monitor LV pressures.


Radiology | 2013

Chronic Liver Disease: Noninvasive Subharmonic Aided Pressure Estimation of Hepatic Venous Pressure Gradient

John R. Eisenbrey; Jaydev K. Dave; Valgerdur G. Halldorsdottir; Daniel A. Merton; Cynthia Miller; José M. Gonzalez; Priscilla Machado; Suhyun Park; Scott Dianis; Carl L. Chalek; Christopher E. Kim; Jeffrey P. Baliff; Kai E. Thomenius; Daniel B. Brown; Victor J. Navarro; Flemming Forsberg

PURPOSE To compare subharmonic aided pressure estimation (SHAPE) with pressure catheter-based measurements in human patients with chronic liver disease undergoing transjugular liver biopsy. MATERIALS AND METHODS This HIPAA-compliant study had U.S. Food and Drug Administration and institutional review board approval, and written informed consent was obtained from all participants. Forty-five patients completed this study between December 2010 and December 2011. A clinical ultrasonography (US) scanner was modified to obtain SHAPE data. After transjugular liver biopsy with pressure measurements as part of the standard of care, 45 patients received an infusion of a microbubble US contrast agent and saline. During infusion, SHAPE data were collected from a portal and hepatic vein and were compared with invasive measurements. Correlations between data sets were determined by using the Pearson correlation coefficient, and statistical significance between groups was determined by using the Student t test. RESULTS The 45 study patients included 27 men and 18 women (age range, 19-71 years; average age, 55.8 years). The SHAPE gradient between the portal and hepatic veins was in good overall agreement with the hepatic venous pressure gradient (HVPG) (R = 0.82). Patients at increased risk for variceal hemorrhage (HVPG ≥ 12 mm Hg) had a significantly higher mean subharmonic gradient than patients with lower HVPGs (1.93 dB ± 0.61 [standard deviation] vs -1.47 dB ± 0.29, P < .001), with a sensitivity of 100% and a specificity of 81%, indicating that SHAPE may be a useful tool for the diagnosis of clinically important portal hypertension. CONCLUSION Preliminary results show SHAPE to be an accurate noninvasive technique for estimating portal hypertension.


Journal of Ultrasound in Medicine | 2010

Static and Dynamic Cumulative Maximum Intensity Display Mode for Subharmonic Breast Imaging A Comparative Study With Mammographic and Conventional Ultrasound Techniques

Jaydev K. Dave; Flemming Forsberg; Savitha Fernandes; Catherine W. Piccoli; Traci B. Fox; Daniel A. Merton; Lauren M. Leodore; Anne L. Hall

Objective. The purpose of this study was to test the efficacy of static and dynamic cumulative maximum intensity (CMI) subharmonic imaging (SHI) in breast ultrasound studies. Methods. Contrast‐enhanced SHI was performed in 14 women using a modified LOGIQ 9 scanner (GE Healthcare, Milwaukee, WI) transmitting/receiving at 4.4/2.2 MHz. Following mammography, baseline scans of gray scale ultrasound and power Doppler imaging (PDI) were performed. Contrast‐enhanced PDI and gray scale SHI were performed after contrast agent administration. Static CMI‐SHI is a composite image summarizing blood flow over multiple frames using the maximum intensity projection technique. The dynamic CMI‐SHI mode depicts the gradual inflow pattern of the contrast agent in blood vessels. Both CMI‐SHI modes were set up using a new automated sum‐absolute‐difference–based block‐matching algorithm to reduce noise and blurring and compensate for motion artifacts. Evaluation of the imaging modes for detecting breast cancer was done by an experienced radiologist, blinded to histopathologic findings. Sensitivity, specificity, and receiver operating characteristic (ROC) analyses were computed and compared for all ultrasound imaging modes and mammography. Results Of the 16 lesions, 4 were malignant. The area under the ROC curve (Az) for the diagnosis of breast cancer was 0.64 for gray scale and PDI, 0.67 for contrast‐enhanced PDI, 0.76 for mammography, 0.78 for SHI, and 0.75 for static CMI‐SHI. For the dynamic CMI‐SHI mode, the Az increased to 0.90, and this was significantly better than mammography (P = .03). Conclusions. The new dynamic CMI‐SHI mode produced the highest Az for the diagnosis of breast cancer compared to conventional techniques and thus appears to improve diagnosis of breast cancer relative to conventional techniques, albeit based on a limited patient population.


Investigative Radiology | 2013

Perfusion estimation using contrast-enhanced 3-dimensional subharmonic ultrasound imaging: an in vivo study.

Anush Sridharan; John R. Eisenbrey; Ji-Bin Liu; Priscilla Machado; Valgerdur G. Halldorsdottir; Jaydev K. Dave; Hongjia Zhao; Yu He; Suhyun Park; Scott Dianis; Kirk Wallace; Kai E. Thomenius; Flemming Forsberg

ObjectivesThe ability to estimate tissue perfusion (in milliliter per minute per gram) in vivo using contrast-enhanced 3-dimensional (3D) harmonic and subharmonic ultrasound imaging was investigated. Materials and MethodsA LOGIQ™ 9 scanner (GE Healthcare, Milwaukee, WI) equipped with a 4D10L probe was modified to perform 3D harmonic imaging (HI; ftransmit, 5 MHz and freceive, 10 MHz) and subharmonic imaging (SHI; ftransmit, 5.8 MHz and freceive, 2.9 MHz). In vivo imaging was performed in the lower pole of both kidneys in 5 open-abdomen canines after injection of the ultrasound contrast agent (UCA) Definity (Lantheus Medical Imaging, N Billerica, MA). The canines received a 5-&mgr;L/kg bolus injection of Definity for HI and a 20-&mgr;L/kg bolus for SHI in triplicate for each kidney. Ultrasound data acquisition was started just before the injection of UCA (to capture the wash-in) and continued until washout. A microvascular staining technique based on stable (nonradioactive) isotope-labeled microspheres (Biophysics Assay Laboratory, Inc, Worcester, MA) was used to quantify the degree of perfusion in each kidney (the reference standard). Ligating a surgically exposed branch of the renal arteries induced lower perfusion rates. This was followed by additional contrast-enhanced imaging and microsphere injections to measure post-ligation perfusion. Slice data were extracted from the 3D ultrasound volumes and used to generate time-intensity curves offline in the regions corresponding to the tissue samples used for microvascular staining. The midline plane was also selected from the 3D volume (as a quasi–2-dimensional [2D] image) and compared with the 3D imaging modes. Perfusion was estimated from the initial slope of the fractional blood volume uptake (for both HI and SHI) and compared with the reference standard using linear regression analysis. ResultsBoth 3D HI and SHI were able to provide visualization of flow and, thus, perfusion in the kidneys. However, SHI provided near-complete tissue suppression and improved visualization of the UCA flow. Microsphere perfusion data were available for 4 canines (1 was excluded because of an error with the reference blood sample) and showed a mean (SD) perfusion of 9.30 (6.60) and 5.15 (3.42) mL/min per gram before and after the ligation, respectively. The reference standard showed significant correlation with the overall 3D HI perfusion estimates (r = 0.38; P = 0.007), but it correlated more strongly with 3D SHI (r = 0.62; P < 0.001). In addition, these results showed an improvement over the quasi-2D HI and SHI perfusion estimates (r = −0.05 and r = 0.14) and 2D SHI perfusion estimates previously reported by our group (r = 0.57). ConclusionsIn this preliminary study, 3D contrast-enhanced nonlinear ultrasound was able to quantify perfusion in vivo. Three-dimensional SHI resulted in better overall agreement with the reference standard than 3D HI did and was superior to previously reported 2D SHI results. Three-dimensional SHI outperforms the other methods for estimating blood perfusion because of the improved visualization of the complete perfused vascular networks.


IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control | 2011

Noninvasive estimation of dynamic pressures in vitro and in vivo using the subharmonic response from microbubbles

Jaydev K. Dave; Valgerdur G. Halldorsdottir; John R. Eisenbrey; Ji-Bin Liu; Maureen E. McDonald; Kris Dickie; Corina Leung; Flemming Forsberg

In this work, the development of subharmonic emission based noninvasive pressure estimation technique is presented. In vitro, ambient pressures were varied (between 0 and 120 mmHg) in a closed-loop flow system circulating 0.2 ml Sonazoid microbubbles (GE Healthcare, Oslo, Norway) suspended in 750 ml of isotonic diluent and recorded by a Millar pressure catheter as the reference standard. Simultaneously, a SonixRP ultrasound scanner (Ultrasonix Medical Corp., Richmond, BC, Canada) operating in pulse inversion mode (ftransmit: 2.5 MHz) was used to acquire unprocessed RF data at five different incident acoustic pressures (from 76 kPa to 897 kPa; n=3). The subharmonic data for each pulse was extracted using band-pass filtering with averaging, and subsequently, processed to eliminate noise. The incident acoustic pressure most sensitive to ambient pressure fluctuations was determined; then the ambient pressure was tracked over 20 seconds. Regression analysis compared subharmonic and catheter pressure values. In vivo validation of this technique was performed noninvasively for tracking left ventricular (LV) pressures of two canines using similar post processing as in vitro. The subharmonic signal tracked ambient pressures with r2 = 0.922 for 20 seconds in vitro. In vivo the subharmonic signal tracked the LV pressures with r2 >; 0.7P90. Maximum errors in estimating clinically relevant systolic and diastolic pressures ranged from 0.22 to 2.84 mmHg using this subharmonic technique relative to Millar catheter pressures. Clinical validation and real time implementation of this technique may ultimately lead to the first noninvasive cardiac pressure monitoring tool.


Ultrasound in Medicine and Biology | 2012

Investigating the Efficacy of Subharmonic Aided Pressure Estimation for Portal Vein Pressures and Portal Hypertension Monitoring

Jaydev K. Dave; Valgerdur G. Halldorsdottir; John R. Eisenbrey; Daniel A. Merton; Ji Bin Liu; Jian Hua Zhou; Hsin Kai Wang; Suhyun Park; Scott Dianis; Carl L. Chalek; Feng Lin; Kai E. Thomenius; Daniel B. Brown; Flemming Forsberg

The efficacy of using subharmonic emissions from Sonazoid microbubbles (GE Healthcare, Oslo, Norway) to track portal vein pressures and pressure changes was investigated in 14 canines using either slow- or high-flow models of portal hypertension (PH). A modified Logiq 9 scanner (GE Healthcare, Milwaukee, WI, USA) operating in subharmonic mode (f(transmit): 2.5 MHz, f(receive): 1.25 MHz) was used to collect radiofrequency data at 10-40% incident acoustic power levels with 2-4 transmit cycles (in triplicate) before and after inducing PH. A pressure catheter (Millar Instruments, Inc., Houston, TX, USA) provided reference portal vein pressures. At optimum insonification, subharmonic signal amplitude changes correlated with portal vein pressure changes; r ranged from -0.82 to -0.94 and from -0.70 to -0.73 for PH models considered separately or together, respectively. The subharmonic signal amplitudes correlated with absolute portal vein pressures (r: -0.71 to -0.79). Statistically significant differences between subharmonic amplitudes, before and after inducing PH, were noted (p ≤ 0.01). Portal vein pressures estimated using subharmonic aided pressure estimation did not reveal significant differences (p > 0.05) with respect to the pressures obtained using the Millar pressure catheter. Subharmonic-aided pressure estimation may be useful clinically for portal vein pressure monitoring.

Collaboration


Dive into the Jaydev K. Dave's collaboration.

Top Co-Authors

Avatar

Flemming Forsberg

Thomas Jefferson University

View shared research outputs
Top Co-Authors

Avatar

John R. Eisenbrey

Thomas Jefferson University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Ji-Bin Liu

Thomas Jefferson University

View shared research outputs
Top Co-Authors

Avatar

Priscilla Machado

Thomas Jefferson University

View shared research outputs
Top Co-Authors

Avatar

Daniel A. Merton

Thomas Jefferson University

View shared research outputs