Radiographics | 2011

Evaluation of Left Ventricular Diastolic Function with Cardiac MR Imaging

Jérôme Caudron; Jeannette Fares; Fabrice Bauer; Jean-Nicolas Dacher

Assessment of left ventricular (LV) function with cardiac magnetic resonance (MR) imaging is often limited to evaluation of systolic function, including analysis of regional wall motion, measurement of mass and volume, and estimation of ejection fraction. However, diastolic dysfunction is present in various heart diseases, particularly in heart failure with preserved ejection fraction, which is increasingly prevalent and is associated with a poor prognosis. In daily practice, the assessment of diastolic function is mainly performed with transthoracic echocardiography. Evaluation of diastolic function with cardiac MR imaging is seldom performed in clinical practice. However, basic assessment of LV relaxation and stiffness abnormalities can be achieved with MR imaging by using a combination of left atrium size measurement and phase-contrast evaluation of transmitral flow. In addition, assessment of pulmonary venous flow and the LV filling curve can also be performed. Furthermore, MR imaging with late gadolinium enhancement sequences provides insight into the extent of myocardial fibrosis, which strongly influences LV stiffness. Finally, phase-contrast evaluation of tissue velocities, myocardial tagging, MR spectroscopy, and MR elastography are promising tools for a better understanding of LV diastolic function but require further evaluation.


Academic Radiology | 2012

Cardiac MRI assessment of right ventricular function in acquired heart disease: factors of variability.

Jérôme Caudron; Jeannette Fares; Valentin Lefebvre; Pierre-Hugues Vivier; Caroline Petitjean; Jean-Nicolas Dacher

RATIONALE AND OBJECTIVES To evaluate intra- and inter-observer variability of right ventricular (RV) functional parameters as evaluated by cardiac magnetic resonance imaging (MRI) in patients with acquired heart disease (AHD), and to identify factors associated with an increased variability. MATERIALS AND METHODS Sixty consecutive patients were enrolled. Right and left ventricular (LV) volumes, ejection fraction, and mass were determined from short-axis cine sequences. All analyzes were performed twice by three observers with various training-degree in cardiac MRI. Intra- and inter-observer variability was evaluated. The impact on variability of each of the following parameters was assessed: observers experience, basal and apical slices selection, end-systolic phase selection, and delineation. RESULTS Mean segmentation time ranged 9.8-19.0 minutes for RV and 6.4-9.2 minutes for LV. Variability of RV functional parameters measurement was strongly influenced by previous observers experience: it was two to three times superior to that of LV, even for the most experienced observer. High variability in the measurement of RV mass was observed. For both ventricles, selection of the basal slice and delineation were major determinants of variability. CONCLUSION As compared to LV, RV function assessment with cardiac MRI in AHD patients is much more variable and time-consuming. Observers experience, selection of basal slice, and delineation are determinant.


computer assisted radiology and surgery | 2011

Automatic cardiac ventricle segmentation in MR images: a validation study.

Damien Grosgeorge; Caroline Petitjean; Jérôme Caudron; Jeannette Fares; Jean-Nicolas Dacher

AbstractPurposeSegmenting the cardiac ventricles in magnetic resonance (MR) images is required for cardiac function assessment. Numerous segmentation methods have been developed and applied to MR ventriculography. Quantitative validation of these segmentation methods with ground truth is needed prior to clinical use, but requires manual delineation of hundreds of images. We applied a well-established method to this problem and rigorously validated the results.MethodsAn automatic method based on active contours without edges was used for left and the right ventricle cavity segmentation. A large database of 1,920 MR images obtained from 59 patients who gave informed consent was evaluated. Two standard metrics were used for quantitative error measurement.ResultsSegmentation results are comparable to previously reported values in the literature. Since different points in the cardiac cycle and different slice levels were used in this study, a detailed error analysis is possible. Better performance was obtained at end diastole than at end systole, and on mid-ventricular slices than apical slices. Localization of segmentation errors were highlighted through a study of their spatial distribution.ConclusionsVentricular segmentation based on region-driven active contours provided satisfactory results in MRI, without the use of a priori knowledge. The study of error distribution allows identification of potential improvements in algorithm performance.


European Radiology | 2011

Diagnostic accuracy and variability of three semi-quantitative methods for assessing right ventricular systolic function from cardiac MRI in patients with acquired heart disease

Jérôme Caudron; Jeannette Fares; Pierre-Hugues Vivier; Valentin Lefebvre; Caroline Petitjean; Jean-Nicolas Dacher

ObjectivesTo evaluate the diagnostic accuracy and variability of 3 semi-quantitative (SQt) methods for assessing right ventricular (RV) systolic function from cardiac MRI in patients with acquired heart disease: tricuspid annular plane systolic excursion (TAPSE), RV fractional-shortening (RVFS) and RV fractional area change (RVFAC).MethodsSixty consecutive patients were enrolled. Reference RV ejection fraction (RVEF) was determined from short axis cine sequences. TAPSE, RVFS and RVFAC were measured on a 4-chamber cine sequence. All SQt analyses were performed twice by 3 observers with various degrees of training in cardiac MRI. Correlation with RVEF, intra- and inter-observer variability, and receiver operating characteristic (ROC) curve analysis were performed for each SQt method.ResultsCorrelation between RVFAC and RVEF was good for all observers and did not depend on previous cardiac MRI experience (R range = 0.716–0.741). Conversely, RVFS (R range = 0.534–0.720) and TAPSE (R range = 0.482–0.646) correlated less with RVEF and depended on previous experience. Intra- and inter-observer variability was much lower for RVFAC than for RVFS and TAPSE. ROC analysis demonstrated that RVFAC <41% could predict a RVEF <45% with 90% sensitivity and 94% specificity.ConclusionsRVFAC appears to be more accurate and reproducible than RVFS and TAPSE for SQt assessment of RV function by cardiac MRI.


American Journal of Cardiology | 2011

Evaluation of Multislice Computed Tomography Early After Transcatheter Aortic Valve Implantation With the Edwards SAPIEN Bioprosthesis

J. Caudron; Jeannette Fares; Camille Hauville; Alain Cribier; Jean-Nicolas Dacher; Christophe Tron; Fabrice Bauer; Pierre-Yves Litzler; Jean-Paul Bessou; H. Eltchaninoff

Currently, imaging assessment of patients who undergo transcatheter aortic valve implantation is based mainly on echocardiography and angiography, both limited to provide a 3-dimensional evaluation of the prosthesis within the native valve. This study involved 34 patients who underwent multislice computed tomography (MSCT) after transcatheter aortic valve implantation. Prosthesis expansion and circularity, depth of implantation, apposition degree at the ventriculoaortic junction, and positioning in relation to coronary artery ostia were evaluated. Early clinical events such as aortic regurgitation and periprocedural conduction abnormalities were recorded and correlated with multislice computed tomographic findings. MSCT provided comprehensive 3-dimensional assessments of the prostheses in 31 of 34 of patients (91%). Expansion was excellent (mean expansion ratio 100.0 ± 10.4%) and increased significantly from the ventricular side to the aortic side of the prosthesis. Circular deployment was achieved in most patients and increased from the ventricular to the aortic side. Mean implantation depth was -2.4 ± 2.5 mm, associated with a low rate (12%) of permanent pacemaker implantation. Patients with a new conduction abnormalities had the deepest prosthesis implantation, associated with lesser expansion and circularity. Perfect apposition on MSCT was associated with a low rate of significant aortic regurgitation. In conclusion, MSCT is able to provide an accurate 3-dimensional evaluation of prosthesis deployment and positioning after transcatheter aortic valve implantation. Moreover, these anatomic findings correlate with the most frequent early complications (i.e., the occurrence of aortic regurgitation and conduction abnormalities).


European Heart Journal | 2009

Diagnosis and follow-up of Wegener's granulomatosis by cardiac magnetic resonance

Jérôme Caudron; Jeannette Fares; Stéphane Dominique; Jean-Nicolas Dacher

A 46-year-old woman was referred to our institution for chest pain and dyspnea. Wegeners granulomatosis (WG) had recently been diagnosed based on typical chest and sinus CT findings. Clinical examination was normal. ECG disclosed an acute episode of atrial fibrillation. Troponin level was moderately increased at 3.25 µg/L. There was a marked inflammatory syndrome (Erythrocyte sedimentation rate 116 mm; C-reative protein …


Archives of Cardiovascular Diseases | 2011

Cardiac computed tomography in right-sided carcinoid heart disease

Jeannette Fares; Jérôme Caudron; Jean-Nicolas Dacher

MOTS CLÉS Valvulopathie ; Cardiopathie carcinoïde ; Scanner cardiaque Ileal carcinoid neoplasm with liver metastasis (Panel A, arrows) was diagnosed recently in this 38-year-old man. Surgical treatment had been scheduled, combining ileo-colectomy and liver transplantation. As the patient complained of dyspnoea on exertion, transthoracic echocardiography (TTE) was performed, which revealed massive pulmonary and tricuspid regurgitation. Left ventricular ejection fraction and left-sided valves were normal. Dose-modulated cardiac computed tomography (CT) (VCT Light Speed 64, General Electric, Milwaukee, WI, USA) was performed to eliminate coronary artery disease before surgery (Fig. 1). Coronary arteries were normal. Multiplanar multiphase reconstruction showed enlarged right cavities, and thickening and retraction of the tricuspid valve and subvalvular apparatus, including chordae and papillary muscles (Panels B, C and D). Tricuspid valve closure was incomplete during systole (Panel C, arrow; Video 1). The pulmonary valve was also thickened and non-coapting at diastole (Panels E, F; Video 2). Moderate cardiac effusion was visible (Panel D, arrow). Although the impact of CT was limited for planning the treatment of cardiac carcinoid disease, it provided a comprehensive depiction of the anatomy of the right-sided cavities and pulmonary valve. The limits of CT must be acknowledged: it cannot assess or quantify valve regurgitation, pulmonary artery pressure or patent foramen ovale (PFO). Also, the temporal resolution of CT does not allow detailed assessment of valve motion compared with TTE.


European Heart Journal | 2009

Magnetic resonance diagnosis of cardiac fat-containing tumours in tuberous sclerosis

Cécile Martin; Jeannette Fares; Pierre Hugues Vivier; Jean-Nicolas Dacher

The patient, 23-year-old man, was known to have tuberous sclerosis (TS). He had been previously diagnosed with renal angiomyolipomas ( Panel A ), and intracranial lesions. He had neither cardiac, nor pulmonary symptoms. Since TS can involve various organs, a chest and abdominal multi detector computed tomography was performed. It incidentally revealed …


Journal of the American College of Cardiology | 2011

CATASTROPHIC OUTCOME OF UNTREATED PATIENTS WITH SEVERE SYMPTOMATIC AORTIC STENOSIS

Jeannette Fares; Hélène Eltchaninoff; Matthieu Godin; Christophe Tron; Fabrice Bauer; Brahim Baala; Alain Cribier


Journal of the American College of Cardiology | 2011

ROLE OF MULTISLICE COMPUTED TOMOGRAPHY TO ASSESS EDWARDS SAPIEN PROSTHESIS DEPLOYMENT AND POSITIONING

Hélène Eltchaninoff; Jérôme Caudron; Jeannette Fares; Camille Hauville; Matthieu Godin; Christophe Tron; Jean-Nicolas Dacher; Alain Cribier

Collaboration


Dive into the Jeannette Fares's collaboration.

Top Co-Authors

Avatar

Jean-Nicolas Dacher

French Institute of Health and Medical Research

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge