Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Jia-Yang Lu is active.

Publication


Featured researches published by Jia-Yang Lu.


PLOS ONE | 2015

Volumetric Modulated Arc Therapy vs. c-IMRT for the Treatment of Upper Thoracic Esophageal Cancer

Wu-Zhe Zhang; Tian-Tian Zhai; Jia-Yang Lu; Jian-Zhou Chen; Zhi-Jian Chen; De-Rui Li; Chuang-Zhen Chen

Objective To compare plans using volumetric-modulated arc therapy (VMAT) with conventional sliding window intensity-modulated radiation therapy (c-IMRT) to treat upper thoracic esophageal cancer (EC). Methods CT datasets of 11 patients with upper thoracic EC were identified. Four plans were generated for each patient: c-IMRT with 5 fields (5F) and VMAT with a single arc (1A), two arcs (2A), or three arcs (3A). The prescribed doses were 64 Gy/32 F for the primary tumor (PTV64). The dose-volume histogram data, the number of monitoring units (MUs) and the treatment time (TT) for the different plans were compared. Results All of the plans generated similar dose distributions for PTVs and organs at risk (OARs), except that the 2A- and 3A-VMAT plans yielded a significantly higher conformity index (CI) than the c-IMRT plan. The CI of the PTV64 was improved by increasing the number of arcs in the VMAT plans. The maximum spinal cord dose and the planning risk volume of the spinal cord dose for the two techniques were similar. The 2A- and 3A-VMAT plans yielded lower mean lung doses and heart V50 values than the c-IMRT. The V20 and V30 for the lungs in all of the VMAT plans were lower than those in the c-IMRT plan, at the expense of increasing V5, V10 and V13. The VMAT plan resulted in significant reductions in MUs and TT. Conclusion The 2A-VMAT plan appeared to spare the lungs from moderate-dose irradiation most effectively of all plans, at the expense of increasing the low-dose irradiation volume, and also significantly reduced the number of required MUs and the TT. The CI of the PTVs and the OARs was improved by increasing the arc-number from 1 to 2; however, no significant improvement was observed using the 3A-VMAT, except for an increase in the TT.


Scientific Reports | 2015

Dosimetric Comparison and Evaluation of Three Radiotherapy Techniques for Use after Modified Radical Mastectomy for Locally Advanced Left-sided Breast Cancer.

Changchun Ma; Wu-Zhe Zhang; Jia-Yang Lu; Li-Li Wu; Fangcai Wu; Bao-Tian Huang; Yan Lin; Dongsheng Li

This study aimed to compare the post-modified radical mastectomy radiotherapy (PMRMRT) for left-sided breast cancer utilizing 3-dimensional conformal radiotherapy with field-in-field technique (3DCRT-FinF), 5-field intensity-modulated radiation therapy (5F-IMRT) and 2- partial arc volumetric modulated arc therapy (2P-VMAT). We created the 3 different PMRMRT plans for each of the ten consecutive patients. We performed Kruskal-Wallis analysis of variance (ANOVA) followed by the Dunn’s-type multiple comparisons to establish a hierarchy in terms of plan quality and dosimetric benefits. P < 0.05 was considered statistically significant. Both 5F-IMRT and 2P-VMAT plans exhibited similar PTV coverage (V95%), hotspot areas (V110%) and conformity (all p > 0.05), and significantly higher PTV coverage compared with 3DCRT-FinF (both p < 0.001). In addition, 5F-IMRT plans provided significantly less heart and left lung radiation exposure than 2P-VMAT (all p < 0.05). The 3DCRT-FinF plans with accurately estimated CTV displacement exhibited enhanced target coverage but worse organs at risk (OARs) sparing compared with those plans with underestimated displacements. Our results indicate that 5F-IMRT has dosimetrical advantages compared with the other two techniques in PMRMRT for left-sided breast cancer given its optimal balance between PTV coverage and OAR sparing (especially heart sparing). Individually quantifying and minimizing CTV displacement can significantly improve dosage distribution.


British Journal of Radiology | 2017

Nomogram for radiation-induced hypothyroidism prediction in nasopharyngeal carcinoma after treatment

Ren Luo; Mei Li; Zhining Yang; Yi-Zhou Zhan; Bao-Tian Huang; Jia-Yang Lu; Zhenxi Xu; Zhixiong Lin

OBJECTIVE The aim of this study was to develop a nomogram for radiation-induced hypothyroidism (RHT) prediction. METHODS We collected data from 164 patients with nasopharyngeal carcinoma (NPC) in our previous prospective study. Biochemical hypothyroidism was defined as a serum thyroid-stimulating hormone level greater than the normal value. We collected both clinical and dose-volume factors. A univariate Cox regression analysis was performed to identify RHT risk factors. Optimal predictors were selected according to the least absolute shrinkage and selection operator (LASSO). We then selected the Cox regression models that best balanced the prediction performance and practicability to build a nomogram for RHT prediction. RESULTS There were 38 (23.2%) patients who developed RHT, and the median follow-up was 24 months. The univariate Cox regression analysis indicated that gender, minimum dose, mean dose (Dmean) and V25-V60 [Vx (%), the percentage of thyroid volume receiving >x Gy] of the thyroid were significantly associated with RHT. The variables of gender, receiving chemotherapy or not (chemo), Dmean and V50 were selected using the LASSO analysis. A nomogram based on a three-variable (gender, chemo and V50) Cox regression model was constructed, and its concordance index was 0.72. Good accordance between prediction and observation was showed by calibration curves in the probability of RHT at 18, 24 and 30 months. CONCLUSION This study built a nomogram for RHT in NPC survivors by analyzing both clinical and dose-volume parameters using LASSO. Thus, the individual dose constraint could be achieved in a visual format. Advances in knowledge: This study used LASSO to more accurately address the multicollinear problem between variables. The resulting nomogram will help physicians predict RHT.


PLOS ONE | 2015

Comparison of Two RapidArc Delivery Strategies in Stereotactic Body Radiotherapy of Peripheral Lung Cancer with Flattening Filter Free Beams

Bao-Tian Huang; Jia-Yang Lu; Pei-Xian Lin; Jian-Zhou Chen; Yu Kuang; Chuang-Zhen Chen

Purpose To investigate the performance of using partial arc (PA) and full arc with avoidance sectors (FAAS) in stereotactic body radiotherapy (SBRT) of peripheral lung cancer with flattening filter free (FFF) beams. Methods Eighteen patients with primary (T1 or T2) non-small-cell lung cancer (NSCLC) or lung metastatic were selected for this study. Nine patients with a gross tumor volume (GTV) <= 10 cc were designated as the small tumor group. The other nine patients with a GTV between 10 cc and 44 cc were assigned to the large tumor group. The treatment plans were generated in eighteen patients using PA and FAAS techniques, respectively, and delivered with a Varian TrueBeam Linac. Dosimetry of the target and organs at risk (OARs), monitor unit (MU), out-of-field dose, and delivery time were statistically analyzed. Delta4 and portal dosimetry were employed to evaluate the delivery accuracy. Results For the small tumor group, compared with the PA plans, the FAAS plans significantly achieved a lower MU/fraction, out-of-field dose and a shorter treatment time (p<0.05), but the target dose was slightly higher than that delivered by PA plans (p<0.05). For the large tumor group, the PA plans significantly attained a shorter treatment time (p<0.05), whereas MU/fraction, out-of-field dose and dose to OARs were comparable between the two plans (p>0.05). Furthermore, all plans generated from the eighteen patients achieved a high pass rate in patient-specific quality assurance, with all the gamma indices greater than 97% at the Γ3mm, 3% threshold. Conclusion This study suggests that the FAAS technique is more beneficial for the small tumor patients undergoing lung SBRT with FFF beams because of its higher treatment efficiency and MU reduction. However, for the large tumor patients, the PA technique is recommended due to its higher treatment efficiency.


Scientific Reports | 2016

Radiobiological modeling analysis of the optimal fraction scheme in patients with peripheral non-small cell lung cancer undergoing stereotactic body radiotherapy

Bao-Tian Huang; Jia-Yang Lu; Pei-Xian Lin; Jian-Zhou Chen; De-Rui Li; Chuang-Zhen Chen

This study aimed to determine the optimal fraction scheme (FS) in patients with small peripheral non-small cell lung cancer (NSCLC) undergoing stereotactic body radiotherapy (SBRT) with the 4 × 12 Gy scheme as the reference. CT simulation data for sixteen patients diagnosed with primary NSCLC or metastatic tumor with a single peripheral lesion ≤3 cm were used in this study. Volumetric modulated arc therapy (VMAT) plans were designed based on ten different FS of 1 × 25 Gy, 1 × 30 Gy, 1 × 34 Gy, 3 × 15 Gy, 3 × 18 Gy, 3 × 20 Gy, 4 × 12 Gy, 5 × 12 Gy, 6 × 10 Gy and 10 × 7 Gy. Five different radiobiological models were employed to predict the tumor control probability (TCP) value. Three other models were utilized to estimate the normal tissue complication probability (NTCP) value to the lung and the modified equivalent uniform dose (mEUD) value to the chest wall (CW). The 1 × 30 Gy regimen is recommended to achieve 4.2% higher TCP and slightly higher NTCP and mEUD values to the lung and CW compared with the 4 × 12 Gy schedule, respectively. This regimen also greatly shortens the treatment duration. However, the 3 × 15 Gy schedule is suggested in patients where the lung-to-tumor volume ratio is small or where the tumor is adjacent to the CW.


Scientific Reports | 2016

Dosimetric evaluation of a simple planning method for improving intensity-modulated radiotherapy for stage III lung cancer

Jia-Yang Lu; Zhu Lin; Jing Zheng; Pei-Xian Lin; Michael Lok-Man Cheung; Bao-Tian Huang

This study aimed to evaluate the dosimetric outcomes of a base-dose-plan-compensation (BDPC) planning method for improving intensity-modulated radiotherapy (IMRT) for stage III lung cancer. For each of the thirteen included patients, three types of planning methods were applied to obtain clinically acceptable plans: (1) the conventional optimization method (CO); (2) a split-target optimization method (STO), in which the optimization objectives were set higher dose for the target with lung density; (3) the BDPC method, which compensated for the optimization-convergence error by further optimization based on the CO plan. The CO, STO and BDPC methods were then compared regarding conformity index (CI), homogeneity index (HI) of the target, organs at risk (OARs) sparing and monitor units (MUs). The BDPC method provided better HI/CI by 54%/7% on average compared to the CO method and by 38%/3% compared to the STO method. The BDPC method also spared most of the OARs by up to 9%. The average MUs of the CO, STO and BDPC plans were 890, 937 and 1023, respectively. Our results indicated that the BDPC method can effectively improve the dose distribution in IMRT for stage III lung cancer, at the expense of more MUs.


PLOS ONE | 2016

Flattening Filter-Free Beams in Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Therapy for Sinonasal Cancer

Jia-Yang Lu; Jing Zheng; Wu-Zhe Zhang; Bao-Tian Huang

Purpose To evaluate the dosimetric impacts of flattening filter-free (FFF) beams in intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) for sinonasal cancer. Methods For fourteen cases, IMRT and VMAT planning was performed using 6-MV photon beams with both conventional flattened and FFF modes. The four types of plans were compared in terms of target dose homogeneity and conformity, organ-at-risk (OAR) sparing, number of monitor units (MUs) per fraction, treatment time and pure beam-on time. Results FFF beams led to comparable target dose homogeneity, conformity, increased number of MUs and lower doses to the spinal cord, brainstem and normal tissue, compared with flattened beams in both IMRT and VMAT. FFF beams in IMRT resulted in improvements by up to 5.4% for sparing of the contralateral optic structures, with shortened treatment time by 9.5%. However, FFF beams provided comparable overall OAR sparing and treatment time in VMAT. With FFF mode, VMAT yielded inferior homogeneity and superior conformity compared with IMRT, with comparable overall OAR sparing and significantly shorter treatment time. Conclusions Using FFF beams in IMRT and VMAT is feasible for the treatment of sinonasal cancer. Our results suggest that the delivery mode of FFF beams may play an encouraging role with better sparing of contralateral optic OARs and treatment efficiency in IMRT, but yield comparable results in VMAT.


British Journal of Radiology | 2016

Effects of omitting elective neck irradiation to nodal Level IB in nasopharyngeal carcinoma patients with negative Level IB lymph nodes treated by intensity-modulated radiotherapy: a Phase 2 study

Mei Li; Xiao-Guang Huang; Zhining Yang; Jia-Yang Lu; Yi-Zhou Zhan; Wen-Jia Xie; Dongjie Zhou; Li Wang; Di-Xia Zhu; Zhixiong Lin

OBJECTIVE To investigate the need for elective neck irradiation (ENI) to nodal Level IB in patients with nasopharyngeal carcinoma (NPC) with negative Level IB lymph nodes (IB-negative) treated by intensity-modulated radiotherapy (IMRT). METHODS We conducted a Phase 2 prospective study in 123 newly diagnosed IB-negative patients with NPC treated by IMRT, who met at least 1 of the following criteria: (1) unilateral or bilateral Level II involvement with 1 of the following: Level IIA involvement or any Level II node ≥2 cm/with extracapsular spread; (2) ≥2 unilateral node-positive regions. Bilateral Level IB nodes were not contoured as part of the treatment target and treated electively. Level IB regional recurrence rate; pattern of treatment failure; 3-year overall survival (3y-OS), 3-year local control (3y-LC) and 3-year regional control (3y-RC) rates; toxicities; and dosimetric data for planning target volumes, organs at risk, Level IB and submandibular glands (SMGs) were evaluated. RESULTS Two patients developed failures at Level IB (1.6%). The 3y-LC, 3y-RC and 3y-OS rates were 93.5%, 93.5% and 78.0%, respectively. Bilateral Level IB received unplanned high-dose irradiation with a mean dose (Dmean) ≥50 Gy in 60% of patients. The average Dmean of bilateral SMGs was approximately 53 Gy. CONCLUSION ENI to Level IB may be unnecessary in IB-negative patients with NPC treated by IMRT. A further Phase 3 study is warranted. ADVANCES IN KNOWLEDGE Based on the results of this first Phase 2 study, we suggest omitting ENI to Level IB in Ib-negative patients with NPC with extensive nodal disease treated by IMRT.


PLOS ONE | 2015

Dosimetric Evaluation of a Simple Planning Technique for Improving Intensity-Modulated Radiotherapy for Nasopharyngeal Cancer.

Jia-Yang Lu; Michael Lok-Man Cheung; Mei Li; Bao-Tian Huang; Wen-Jia Xie; Liang-Xi Xie

Purpose To evaluate the dosimetric outcomes of a simple planning technique for improving intensity-modulated radiotherapy (IMRT) for nasopharyngeal cancer (NPC). Methods For 39 NPC cases, generally acceptable original plans were generated and were improved by the two planning techniques, respectively: (1) a basal-dose-compensation (BDC) technique, in which the treatment plans were re-optimized based on the original plans; (2) a local-dose-control (LDC) technique, in which the original plans were re-optimized with constraints for hot and cold spots. The BDC, original, and LDC plans were then compared regarding homogeneity index (HI) and conformity index (CI) of planning target volumes (PTVs), organ-at-risk (OAR) sparing and monitor units (MUs) per fraction. The whole planning times were also compared between the BDC and LDC plans. Results The BDC plans had superior HIs / CIs, by 13-24% / 3-243%, respectively, over the original plans. Compared to the LDC plans, the BDC plans provided better HIs only for PTVnx (the PTV of nasopharyngeal primary tumor) by 11% and better CIs for all PTVs by 2-134%. The BDC technique spared most OARs, by 1-9%. The average MUs of the BDC, original, and LDC plans were 2149, 2068 and 2179, respectively. The average whole planning times were 48 and 69 minutes for the BDC and LDC plans, respectively. Conclusions For the IMRT of nasopharyngeal cancer, the BDC planning technique can improve target dose homogeneity, conformity and OAR sparing, with better planning efficiency.


Scientific Reports | 2016

Monitor unit optimization in stereotactic body radiotherapy for small peripheral non-small cell lung cancer patients.

Bao-Tian Huang; Zhu Lin; Pei-Xian Lin; Jia-Yang Lu; Chuang-Zhen Chen

The increasingly attractive stereotactic body radiotherapy (SBRT) treatment for stage I lung cancer is concomitant with a large amount of monitor units (MU), leading to excessive out-of-field dose and prolonged beam-on time. The study aims to reduce the MU number and shorten the beam-on time by optimizing the planning parameters. Clinically acceptable treatment plans from fourteen patients suffered from peripheral stage I non-small cell lung cancer (NSCLC) were created in the study. Priority for the upper objective of the target (PUOT), strength and Max MU setting in the MU objective function (MUOF) were adjusted respectively to investigate their effect on MU number, organs at risk (OARs) sparing and beam-on time. We found that the planning parameters influenced the MU number in a PUOT, strength and Max MU dependent manner. Combined with high priority for the UOT (HPUOT) and MUOF, the MU number was reduced from 443 ± 25 to 228 ± 22 MU/Gy without compromising the target coverage and OARs sparing. We also found beam-on time was proportional to MU number and it could be shortened from 7.9 ± 0.5 to 4.1 ± 0.4 minutes.

Collaboration


Dive into the Jia-Yang Lu's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jing Zheng

Sun Yat-sen University

View shared research outputs
Researchain Logo
Decentralizing Knowledge