Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Pei-Xian Lin is active.

Publication


Featured researches published by Pei-Xian Lin.


PLOS ONE | 2015

Comparison of Two RapidArc Delivery Strategies in Stereotactic Body Radiotherapy of Peripheral Lung Cancer with Flattening Filter Free Beams

Bao-Tian Huang; Jia-Yang Lu; Pei-Xian Lin; Jian-Zhou Chen; Yu Kuang; Chuang-Zhen Chen

Purpose To investigate the performance of using partial arc (PA) and full arc with avoidance sectors (FAAS) in stereotactic body radiotherapy (SBRT) of peripheral lung cancer with flattening filter free (FFF) beams. Methods Eighteen patients with primary (T1 or T2) non-small-cell lung cancer (NSCLC) or lung metastatic were selected for this study. Nine patients with a gross tumor volume (GTV) <= 10 cc were designated as the small tumor group. The other nine patients with a GTV between 10 cc and 44 cc were assigned to the large tumor group. The treatment plans were generated in eighteen patients using PA and FAAS techniques, respectively, and delivered with a Varian TrueBeam Linac. Dosimetry of the target and organs at risk (OARs), monitor unit (MU), out-of-field dose, and delivery time were statistically analyzed. Delta4 and portal dosimetry were employed to evaluate the delivery accuracy. Results For the small tumor group, compared with the PA plans, the FAAS plans significantly achieved a lower MU/fraction, out-of-field dose and a shorter treatment time (p<0.05), but the target dose was slightly higher than that delivered by PA plans (p<0.05). For the large tumor group, the PA plans significantly attained a shorter treatment time (p<0.05), whereas MU/fraction, out-of-field dose and dose to OARs were comparable between the two plans (p>0.05). Furthermore, all plans generated from the eighteen patients achieved a high pass rate in patient-specific quality assurance, with all the gamma indices greater than 97% at the Γ3mm, 3% threshold. Conclusion This study suggests that the FAAS technique is more beneficial for the small tumor patients undergoing lung SBRT with FFF beams because of its higher treatment efficiency and MU reduction. However, for the large tumor patients, the PA technique is recommended due to its higher treatment efficiency.


Scientific Reports | 2016

Radiobiological modeling analysis of the optimal fraction scheme in patients with peripheral non-small cell lung cancer undergoing stereotactic body radiotherapy

Bao-Tian Huang; Jia-Yang Lu; Pei-Xian Lin; Jian-Zhou Chen; De-Rui Li; Chuang-Zhen Chen

This study aimed to determine the optimal fraction scheme (FS) in patients with small peripheral non-small cell lung cancer (NSCLC) undergoing stereotactic body radiotherapy (SBRT) with the 4 × 12 Gy scheme as the reference. CT simulation data for sixteen patients diagnosed with primary NSCLC or metastatic tumor with a single peripheral lesion ≤3 cm were used in this study. Volumetric modulated arc therapy (VMAT) plans were designed based on ten different FS of 1 × 25 Gy, 1 × 30 Gy, 1 × 34 Gy, 3 × 15 Gy, 3 × 18 Gy, 3 × 20 Gy, 4 × 12 Gy, 5 × 12 Gy, 6 × 10 Gy and 10 × 7 Gy. Five different radiobiological models were employed to predict the tumor control probability (TCP) value. Three other models were utilized to estimate the normal tissue complication probability (NTCP) value to the lung and the modified equivalent uniform dose (mEUD) value to the chest wall (CW). The 1 × 30 Gy regimen is recommended to achieve 4.2% higher TCP and slightly higher NTCP and mEUD values to the lung and CW compared with the 4 × 12 Gy schedule, respectively. This regimen also greatly shortens the treatment duration. However, the 3 × 15 Gy schedule is suggested in patients where the lung-to-tumor volume ratio is small or where the tumor is adjacent to the CW.


Scientific Reports | 2016

Dosimetric evaluation of a simple planning method for improving intensity-modulated radiotherapy for stage III lung cancer

Jia-Yang Lu; Zhu Lin; Jing Zheng; Pei-Xian Lin; Michael Lok-Man Cheung; Bao-Tian Huang

This study aimed to evaluate the dosimetric outcomes of a base-dose-plan-compensation (BDPC) planning method for improving intensity-modulated radiotherapy (IMRT) for stage III lung cancer. For each of the thirteen included patients, three types of planning methods were applied to obtain clinically acceptable plans: (1) the conventional optimization method (CO); (2) a split-target optimization method (STO), in which the optimization objectives were set higher dose for the target with lung density; (3) the BDPC method, which compensated for the optimization-convergence error by further optimization based on the CO plan. The CO, STO and BDPC methods were then compared regarding conformity index (CI), homogeneity index (HI) of the target, organs at risk (OARs) sparing and monitor units (MUs). The BDPC method provided better HI/CI by 54%/7% on average compared to the CO method and by 38%/3% compared to the STO method. The BDPC method also spared most of the OARs by up to 9%. The average MUs of the CO, STO and BDPC plans were 890, 937 and 1023, respectively. Our results indicated that the BDPC method can effectively improve the dose distribution in IMRT for stage III lung cancer, at the expense of more MUs.


Scientific Reports | 2017

Different definitions of esophagus influence esophageal toxicity prediction for esophageal cancer patients administered simultaneous integrated boost versus standard-dose radiation therapy

Bao-Tian Huang; Ruihong Huang; Wu-Zhe Zhang; Wen Lin; Longjia Guo; Liang-yu Xu; Pei-Xian Lin; Jian-Zhou Chen; De-Rui Li; Chuang-Zhen Chen

We aim to evaluate whether different definitions of esophagus (DEs) impact on the esophageal toxicity prediction for esophageal cancer (EC) patients administered intensity-modulated radiation therapy with simultaneous integrated boost (SIB-IMRT) vs. standard-dose IMRT (SD-IMRT). The esophagus for 21 patients diagnosed with primary EC were defined in the following four ways: the whole esophagus, including the tumor (ESOwhole); ESOwhole within the treatment field (ESOinfield); ESOinfield, excluding the tumor (ESOinfield-tumor) and ESOwhole, excluding the tumor (ESOwhole-tumor). The difference in the dose variation, acute esophageal toxicity (AET) and late esophageal toxicity (LET) of four DEs were compared. We found that the mean esophageal dose for ESOwhole, ESOinfield, ESOinfield-tumor and ESOwhole-tumor were increased by 7.2 Gy, 10.9 Gy, 4.6 Gy and 2.0 Gy, respectively, in the SIB-IMRT plans. Radiobiological models indicated that a grade ≥ 2 AET was 2.9%, 3.1%, 2.2% and 1.6% higher on average with the Kwint model and 14.6%, 13.2%, 7.2% and 3.4% higher with the Wijsman model for the four DEs. A grade ≥ 3 AET increased by 4.3%, 7.2%, 4.2% and 1.2%, respectively. Additionally, the predicted LET increased by 0.15%, 0.39%, 1.2 × 10−2% and 1.5 × 10−3%. Our study demonstrates that different DEs influence the esophageal toxicity prediction for EC patients administered SIB-IMRT vs. SD-IMRT treatment.


Scientific Reports | 2016

Monitor unit optimization in stereotactic body radiotherapy for small peripheral non-small cell lung cancer patients.

Bao-Tian Huang; Zhu Lin; Pei-Xian Lin; Jia-Yang Lu; Chuang-Zhen Chen

The increasingly attractive stereotactic body radiotherapy (SBRT) treatment for stage I lung cancer is concomitant with a large amount of monitor units (MU), leading to excessive out-of-field dose and prolonged beam-on time. The study aims to reduce the MU number and shorten the beam-on time by optimizing the planning parameters. Clinically acceptable treatment plans from fourteen patients suffered from peripheral stage I non-small cell lung cancer (NSCLC) were created in the study. Priority for the upper objective of the target (PUOT), strength and Max MU setting in the MU objective function (MUOF) were adjusted respectively to investigate their effect on MU number, organs at risk (OARs) sparing and beam-on time. We found that the planning parameters influenced the MU number in a PUOT, strength and Max MU dependent manner. Combined with high priority for the UOT (HPUOT) and MUOF, the MU number was reduced from 443 ± 25 to 228 ± 22 MU/Gy without compromising the target coverage and OARs sparing. We also found beam-on time was proportional to MU number and it could be shortened from 7.9 ± 0.5 to 4.1 ± 0.4 minutes.


OncoTargets and Therapy | 2017

Radiobiological evaluation of simultaneously dose-escalated versus non-escalated intensity-modulated radiation therapy for patients with upper thoracic esophageal cancer

Bao-Tian Huang; Li-Li Wu; Longjia Guo; Liang-yu Xu; Ruihong Huang; Pei-Xian Lin; Jian-Zhou Chen; De-Rui Li; Chuang-Zhen Chen

Objective To compare the radiobiological response between simultaneously dose-escalated and non-escalated intensity-modulated radiation therapy (DE-IMRT and NE-IMRT) for patients with upper thoracic esophageal cancer (UTEC) using radiobiological evaluation. Methods Computed tomography simulation data sets for 25 patients pathologically diagnosed with primary UTEC were used in this study. DE-IMRT plan with an escalated dose of 64.8 Gy/28 fractions to the gross tumor volume (GTV) and involved lymph nodes from 25 patients pathologically diagnosed with primary UTEC, was compared to an NE-IMRT plan of 50.4 Gy/28 fractions. Dose-volume metrics, tumor control probability (TCP), and normal tissue complication probability for the lung and spinal cord were compared. In addition, the risk of acute esophageal toxicity (AET) and late esophageal toxicity (LET) were also analyzed. Results Compared with NE-IMRT plan, we found the DE-IMRT plan resulted in a 14.6 Gy dose escalation to the GTV. The tumor control was predicted to increase by 31.8%, 39.1%, and 40.9% for three independent TCP models. The predicted incidence of radiation pneumonitis was similar (3.9% versus 3.6%), and the estimated risk of radiation-induced spinal cord injury was extremely low (<0.13%) in both groups. Regarding the esophageal toxicities, the estimated grade ≥2 and grade ≥3 AET predicted by the Kwint model were increased by 2.5% and 3.8%. Grade ≥2 AET predicted using the Wijsman model was increased by 14.9%. The predicted incidence of LET was low (<0.51%) in both groups. Conclusion Radiobiological evaluation reveals that the DE-IMRT dosing strategy is feasible for patients with UTEC, with significant gains in tumor control and minor or clinically acceptable increases in radiation-induced toxicities.


BioMed Research International | 2017

Comparative Analysis of Local Control Prediction Using Different Biophysical Models for Non-Small Cell Lung Cancer Patients Undergoing Stereotactic Body Radiotherapy

Bao-Tian Huang; Wu-Zhe Zhang; Li-Li Wu; Pei-Xian Lin; Jia-Yang Lu

Purpose The consistency for predicting local control (LC) data using biophysical models for stereotactic body radiotherapy (SBRT) treatment of lung cancer is unclear. This study aims to compare the results calculated from different models using the treatment planning data. Materials and Methods Treatment plans were designed for 17 patients diagnosed with primary non-small cell lung cancer (NSCLC) using 5 different fraction schemes. The Martel model, Ohri model, and the Tai model were used to predict the 2-year LC value. The Gucken model, Santiago model, and the Tai model were employed to estimate the 3-year LC data. Results We found that the employed models resulted in completely different LC prediction except for the Gucken and the Santiago models which exhibited quite similar 3-year LC data. The predicted 2-year and 3-year LC values in different models were not only associated with the dose normalization but also associated with the employed fraction schemes. The greatest difference predicted by different models was up to 15.0%. Conclusions Our results show that different biophysical models influence the LC prediction and the difference is not only correlated to the dose normalization but also correlated to the employed fraction schemes.


Oncotarget | 2016

Radiobiological modeling of two stereotactic body radiotherapy schedules in patients with stage I peripheral non-small cell lung cancer

Bao-tian Huang; Zhu Lin; Pei-Xian Lin; Jia-Yang Lu; Chuang-Zhen Chen

This study aims to compare the radiobiological response of two stereotactic body radiotherapy (SBRT) schedules for patients with stage I peripheral non-small cell lung cancer (NSCLC) using radiobiological modeling methods. Volumetric modulated arc therapy (VMAT)-based SBRT plans were designed using two dose schedules of 1 × 34 Gy (34 Gy in 1 fraction) and 4 × 12 Gy (48 Gy in 4 fractions) for 19 patients diagnosed with primary stage I NSCLC. Dose to the gross target volume (GTV), planning target volume (PTV), lung and chest wall (CW) were converted to biologically equivalent dose in 2 Gy fraction (EQD2) for comparison. Five different radiobiological models were employed to predict the tumor control probability (TCP) value. Three additional models were utilized to estimate the normal tissue complication probability (NTCP) value for the lung and the modified equivalent uniform dose (mEUD) value to the CW. Our result indicates that the 1 × 34 Gy dose schedule provided a higher EQD2 dose to the tumor, lung and CW. Radiobiological modeling revealed that the TCP value for the tumor, NTCP value for the lung and mEUD value for the CW were 7.4% (in absolute value), 7.2% (in absolute value) and 71.8% (in relative value) higher on average, respectively, using the 1 × 34 Gy dose schedule.


Medical Physics | 2014

TH-C-12A-02: Comparison of Two RapidArc Delivery Strategies in Stereotactic Body Radiotherapy of Stage I and II Peripheral Lung Tumors with Unflattened Beams

B-T Huang; J-Y Lu; Pei-Xian Lin; Jian-Zhou Chen; Yu Kuang; Chuang-Zhen Chen

PURPOSE The full arcs strategy used in SBRT with RapidArc and unflattened (FFF) beams in large and heterogeneous peripheral non-smallcell lung cancer (NSCLC) appears to be suboptimal as it increases the disadvantageous dose to the contralateral lung, which potentially increases the toxicity to surrounding tissues. In this study, we investigated, for the first time, the dose delivery strategies using partial arcs (PA) and the fully rotational arcs with avoidance sectors (FAAS) for SBRT with FFF beams in peripheral NSCLC patients. METHODS Eighteen patients with NSCLC (stage I and II) were selected for this study. Nine patients with a GTV <= 10cc were designated as the small tumor group. The remaining nine patients with a GTV between 10 cc and 44 cc were assigned to the large tumor group. The treatment plans were generated in eighteen patients using PA and FAAS, respectively, and delivered with a Varian TrueBeam Linac. Dosimetry of the target and organs at risk (OAR), total MU, out-of-field dose, and delivery time were analyzed. Delta4 and Portal dosimetry were employed to evaluate the delivery accuracy. RESULTS or the small tumor group, the FAAS plans significantly achieved a better conformity index, the lower total MU and out-of-field dose, a shorter treatment time, and the reduced doses to cord, heart, and lung (p < 0.05). But the target doses were slightly higher than that delivered by PA plans. For the large tumor group, the PA plans significantly attained a better conformity index and a shorter treatment time (p < 0.05). Furthermore, all plans achieved a high pass rate, with all the gamma indices greater than 97% at the Г3mm, 3% threshold. CONCLUSION This study suggests that FAAS strategy is more beneficial for small tumor patients undergoing lung SBRT with FFF beams. However, for large tumor patients, PA strategy is recommended. NIH/NIGMS grant U54 GM104944, Lincy Endowed Assistant Professorship.


Radiation Oncology | 2015

Dose calculation of Acuros XB and Anisotropic Analytical Algorithm in lung stereotactic body radiotherapy treatment with flattening filter free beams and the potential role of calculation grid size

Bao-Tian Huang; Lili Wu; Pei-Xian Lin; Chuangzhen Chen

Collaboration


Dive into the Pei-Xian Lin's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Yu Kuang

Case Western Reserve University

View shared research outputs
Researchain Logo
Decentralizing Knowledge