Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Johannes K. M. Fakler is active.

Publication


Featured researches published by Johannes K. M. Fakler.


Orthopedics | 2008

Current Concepts in the Treatment of Proximal Humeral Fractures

Johannes K. M. Fakler; Craig Hogan; Christoph E. Heyde; Thilo John

Preoperative classification of proximal humeral fractures in addition to thorough knowledge of the specific anatomy and vascular blood supply is more important for successful treatment than the choice of implant. If reduction and fixation is necessary, aggressive reduction maneuvers can compromise humeral head perfusion with subsequent humeral head necrosis regardless of the implant used. Modern implants such as intramedullary proximal humeral nails and anatomically designed proximal humeral angular stable plates offer high primary stability even in osteoporotic bone with preservation of periosteal blood supply to the humeral head. These implants allow early functional exercises and showed good to excellent results in the majority of patients with an acceptable complication rate. Increasing experience with these relatively new implants and further technical development might improve clinical results and reduce complications. Minimally invasive, percutaneous techniques also demonstrate favorable results comparable to those mentioned above, although mean patient age tends to be younger in these studies and complications requiring reoperation tend to be more pronounced in elderly patients due to poor bone quality. Alternatively, nonoperative treatment of displaced two- and three-part fractures in elderly patients with severe morbidity and high perioperative risks should be considered. In elderly patients with selected displaced four-part fractures or fracture dislocations and head-split fractures, hemiarthroplasty offers high subjective patient satisfaction despite moderate function with most of the patients being pain free.


Patient Safety in Surgery | 2008

Pitfalls and complications in the treatment of cervical spine fractures in patients with ankylosing spondylitis

C.-E. Heyde; Johannes K. M. Fakler; Erik A Hasenboehler; Philip F. Stahel; Thilo John; Yohan Robinson; Sven K. Tschoeke; Ralph Kayser

Patients with ankylosing spondylitis are at significant risk for sustaining cervical spine injuries following trauma predisposed by kyphosis, stiffness and osteoporotic bone quality of the spine. The risk of sustaining neurological deficits in this patient population is higher than average. The present review article provides an outline on the specific injury patterns in the cervical spine, diagnostic algorithms and specific treatment modalities dictated by the underlying disease in patients with ankylosing spondylitis. An emphasis is placed on the risks and complication patterns in the treatment of these rare, but challenging injuries.


Patient Safety in Surgery | 2007

Errors in handling and manufacturing of orthopaedic implants: the tip of the iceberg of an unrecognized system problem?

Johannes K. M. Fakler; Yohan Robinson; Christoph E. Heyde; Thilo John

Patient safety related to orthopaedic implants, particularly joint arthroplasty, is a major concern due to the increasing elderly population and the wide variety of available devices. The safe use of medical devices, such as orthopaedic implants, is regulated by institutions or governmental agencies in many countries. Nevertheless, adverse incidents associated with the implantation of orthopaedic devices in patients are reported periodically in the news media.


Scientific Reports | 2018

Mechanical complications and outcomes following invasive emergency procedures in severely injured trauma patients

Manuel F. Struck; Johannes K. M. Fakler; M. Bernhard; Thilo Busch; Patrick Stumpp; Gunther Hempel; André Beilicke; Sebastian N. Stehr; Christoph Josten; Hermann Wrigge

This study aimes to determine the complication rates, possible risk factors and outcomes of emergency procedures performed during resuscitation of severely injured patients. The medical records of patients with an injury severity score (ISS) >15 admitted to the University Hospital Leipzig from 2010 to 2015 were reviewed. Within the first 24 hours of treatment, 526 patients had an overall mechanical complication rate of 26.2%. Multivariate analysis revealed out-of-hospital airway management (OR 3.140; 95% CI 1.963–5.023; p < 0.001) and ISS (per ISS point: OR 1.024; 95% CI 1.003–1.045; p = 0.027) as independent predictors of any mechanical complications. Airway management complications (13.2%) and central venous catheter complications (11.4%) were associated with ISS >32.5 (p < 0.001) and ISS >33.5 (p = 0.005), respectively. Chest tube complications (15.8%) were associated with out-of-hospital insertion (p = 0.002) and out-of-hospital tracheal intubation (p = 0.033). Arterial line complications (9.4%) were associated with admission serum lactate >4.95 mmol/L (p = 0.001) and base excess <−4.05 mmol/L (p = 0.008). In multivariate analysis, complications were associated with an increased length of stay in the intensive care unit (p = 0.019) but not with 24 hour mortality (p = 0.930). Increasing injury severity may contribute to higher complexity of the individual emergency treatment and is thus associated with higher mechanical complication rates providing potential for further harm.


European Journal of Trauma and Emergency Surgery | 2018

Clinical consequences of chest tube malposition in trauma resuscitation: single-center experience

Manuel F. Struck; Sebastian Ewens; Johannes K. M. Fakler; Gunther Hempel; André Beilicke; M. Bernhard; Patrick Stumpp; Christoph Josten; Sebastian N. Stehr; Hermann Wrigge; Sebastian Krämer

PurposeEvaluation of trauma patients with chest tube malposition using initial emergency computed tomography (CT) and assessment of outcomes and the need for chest tube replacement.MethodsPatients with an injury severity score > 15, admitted directly from the scene, and requiring chest tube insertion prior to initial emergency CT were retrospectively reviewed. Injury severity, outcomes, and the positions of chest tubes were analyzed with respect to the need for replacement after CT.ResultsOne hundred seven chest tubes of 78 patients met the inclusion criteria. Chest tubes were in the pleural space in 58% of cases. Malposition included intrafissural positions (27%), intraparenchymal positions (11%) and extrapleural positions (4%). Injury severity and outcomes were comparable in patients with and without malposition. Replacement due to malfunction was required at similar rates when comparing intrapleural positions with both intrafissural or intraparenchymal positions (11 vs. 23%, p = 0.072). Chest tubes not reaching the target position (e.g., pneumothorax) required replacement more often than targeted tubes (75 vs. 45%, p = 0.027). Out-of-hospital insertions required higher replacement rates than resuscitation room insertions (29 vs. 10%, p = 0.016). Body mass index, chest wall thickness, injury severity, insertion side and intercostal space did not predict the need for replacement.ConclusionsPatients with malposition of emergency chest tubes according to CT were not associated with worse outcomes compared to patients with correctly positioned tubes. Early emergency chest CT in the initial evaluation of severely injured patients allows precise detection of possible malposition of chest tubes that may require immediate intervention.


BMC Musculoskeletal Disorders | 2017

A new classification of TKA periprosthetic femur fractures considering the implant type

Johannes K. M. Fakler; Cathleen Pönick; Melanie Edel; Robert Möbius; Alexander Giselher Brand; Andreas Roth; Christoph Josten; Dirk Zajonz

BackgroundThe treatment aims of periprosthetic fractures (PPF) of the distal femur are a gentle stabilization, an early load-bearing capacity and a rapid postoperative mobilization of the affected patients. For the therapy planning of PPF a standardized classification is necessary which leads to a clear and safe therapy recommendation. Despite different established classifications, there is none that includes the types of prosthesis used in the assessment. For this purpose, the objective of this work is to create a new more extensive fracture and implant-related classification of periprosthetic fractures of the distal femur based on available classifications which allows distinct therapeutic recommendations.MethodsIn a retrospective analysis all patients who were treated in the University Hospital Leipzig from 2010 to 2016 due to a distal femur fracture with total knee arthroplasty (TKA) were established. To create an implant-associated classification the cases were discussed in a panel of experienced orthopaedists and well-practiced traumatologists with a great knowledge in the field of endoprosthetics and fracture care. In this context, two experienced surgeons classified 55 consecutive fractures according to Su et al., Lewis and Rorabeck and by the new created classification. In this regard, the interobserver reliability was determined for two independent raters in terms of Cohen Kappa.ResultsOn the basis of the most widely recognized classifications of Su et al. as well as Lewis and Rorabeck, we established an implant-dependent classification for PPF of the distal femur. In accordance with the two stated classifications four fracture types were created and defined. Moreover, the four most frequent prosthesis types were integrated. Finally, a new classification with 16 subtypes was generated based on four types of fracture and four types of prosthesis. Considering all cases the presented implant-associated classification (κ = 0.74) showed a considerably higher interobserver reliability compared to the other classifications of Su et al. (κ = 0.39) as well as Lewis and Rorabeck (κ = 0.31). Excluding the cases which were only assessable by the new classification, it still shows a higher interobserver reliability (κ = 0.70) than the other ones (κ = 0.63 or κ = 0.45).ConclusionsThe new classification system for PPF of the distal femur following TKA considers fracture location and implant type. It is easy to use, shows agood interobserver reliability and allows conclusions to be drawn on treatment recommendations. Moreover, further studies on the evaluation of the classification are necessary and planned.


Journal of Vascular Access | 2018

Central venous catheterization for acute trauma resuscitation: Tip position analysis using routine emergency computed tomography:

Manuel F. Struck; Sebastian Ewens; Wolfram Schummer; Thilo Busch; M. Bernhard; Johannes K. M. Fakler; Patrick Stumpp; Sebastian N. Stehr; Christoph Josten; Hermann Wrigge

Purpose: Central venous catheter insertion for acute trauma resuscitation may be associated with mechanical complications, but studies on the exact central venous catheter tip positions are not available. The goal of the study was to analyze central venous catheter tip positions using routine emergency computed tomography. Methods: Consecutive acute multiple trauma patients requiring large-bore thoracocervical central venous catheters in the resuscitation room of a university hospital were enrolled retrospectively from 2010 to 2015. Patients who received a routine emergency chest computed tomography were analyzed regarding central venous catheter tip position. The central venous catheter tip position was defined as correct if the catheter tip was placed less than 1 cm inside the right atrium relative to the cavoatrial junction, and the simultaneous angle of the central venous catheter tip compared with the lateral border of the superior vena cava was below 40°. Results: During the 6-year study period, 97 patients were analyzed for the central venous catheter tip position in computed tomography. Malpositions were observed in 29 patients (29.9%). Patients with malpositioned central venous catheters presented with a higher rate of shock (systolic blood pressure <90 mmHg) at admission (58.6% vs 33.8%, p = 0.023) and a higher mean injury severity score (38.5 ± 15.7 vs 31.6 ± 11.8, p = 0.041) compared with patients with correctly positioned central venous catheter tips. Logistic regression revealed injury severity score as a significant predictor for central venous catheter malposition (odds ratio = 1.039, 95% confidence interval = 1.005–1.074, p = 0.024). Conclusion: Multiple trauma patients who underwent emergency central venous catheter placement by experienced anesthetists presented with considerable tip malposition in computed tomography, which was significantly associated with a higher injury severity.


Clinical Interventions in Aging | 2018

The significance of the vitamin D metabolism in the development of periprosthetic infections after THA and TKA: a prospective matched-pair analysis of 240 patients

Dirk Zajonz; Florian Lutz Prager; Melanie Edel; Robert Möbius; Alexandros Daikos; Johannes K. M. Fakler; Christoph Josten; Jürgen Kratzsch; Andreas Roth

Background The importance of the vitamin D homeostasis in infections is already known. However, its significance in periprosthetic infections (PPIs) after total hip arthroplasty and total knee arthroplasty is largely unexplored. The aim of the study is to precisely analyze the vitamin D balance in patients with PPIs after total hip arthroplasty and total knee arthroplasty. Here, cases with primary endoprosthesis implants and aseptic loosening are used as comparison groups. Materials and methods In this prospective matched-pair analysis, patients with PPI at the hip and knee joints were included in the study group (SG). The control groups (CGs) consisted of patients with primary implants (CG I) and who underwent replacement surgery due to aseptic loosening (CG II). In addition to 25 OH vitamin D3 and calcium, bone mineral and protein parameters were determined. An osteoporosis-specific questionnaire was collected. Results There are no significant differences in the 25 OH-vitamin D levels between the SG (17.9±8.9) and both CGs (CG I: 16.8±6.90; CG II: 19.7±7.90). However, compared with the SG, significantly higher levels of calcium (Ca) and bone-specific alkaline phosphatase were found in both CGs in comparison with the SG. Significantly lower values concerning the protein balance in PPI were conspicuous. Acute PPI showed a significant reduction in 25 OH vitamin D3 compared with chronic infections (8.3±5.98 vs 21.6±8.40, P=0.002). Calcium and protein balance were also significantly reduced in acute PPIs. Conclusion Acute PPIs of the hip and knee joints show a significantly reduced calcium and 25 OH vitamin D3 levels as well as lowered proteins (albumin and total protein) compared with chronic infections as well as primary endoprostheses and aseptic replacement operations. Substitution of vitamin D3 and calcium with simultaneous adaptation of the protein balance is recommended in all PPIs, especially in the acute PPI.


Journal of Orthopaedic Trauma | 2007

Optimizing the management of Moore type I postero-medial split fracture dislocations of the tibial head: description of the Lobenhoffer approach.

Johannes K. M. Fakler; Mark Ryzewicz; Cody J. Hartshorn; Steven J. Morgan; Philip F. Stahel; Wade R. Smith


Patient Safety in Surgery | 2013

Safety aspects in surgical treatment of pathological fractures of the proximal femur - modular endoprosthetic replacement vs. intramedullary nailing

Johannes K. M. Fakler; Franziska Hase; Jörg Böhme; Christoph Josten

Collaboration


Dive into the Johannes K. M. Fakler's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Philip F. Stahel

University of Colorado Denver

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge