John Kitching
National Institute of Standards and Technology
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by John Kitching.
Applied Physics Letters | 2004
Svenja Knappe; Vishal Shah; Peter D. D. Schwindt; Leo W. Hollberg; John Kitching; Li-Anne Liew; John M. Moreland
Fabrication techniques usually applied to microelectromechanical systems (MEMS) are used to reduce the size and operating power of the core physics assembly of an atomic clock. With a volume of 9.5mm3, a fractional frequency instability of 2.5×10−10 at 1s of integration, and dissipating less than 75mW of power, the device has the potential to bring atomically precise timing to hand-held, battery-operated devices. In addition, the design and fabrication process allows for wafer-level assembly of the structures, enabling low-cost mass-production of thousands of identical units with the same process sequence, and easy integration with other electronics.
Applied Physics Letters | 2004
Li-Anne Liew; Svenja Knappe; John M. Moreland; Hugh Robinson; Leo W. Hollberg; John Kitching
We describe the fabrication of chip-sized alkali atom vapor cells using silicon micromachining and anodic bonding technology. Such cells may find use in highly miniaturized atomic frequency references or magnetometers. The cells consist of cavities etched in silicon, with internal volumes as small as 1 mm3. Two techniques for introducing cesium and a buffer gas into the cells are described: one based on chemical reaction between cesium chloride and barium azide, and the other based on direct injection of elemental cesium within a controlled anaerobic environment. Cesium optical absorption and coherent population trapping resonances were measured in the cells.
IEEE\/ASME Journal of Microelectromechanical Systems | 2002
Yang Zhao; Minyao Mao; Roberto Horowitz; Arunava Majumdar; J. B. Varesi; Paul R. Norton; John Kitching
This paper presents the design, fabrication and performance of an uncooled micro-optomechanical infrared (IR) imaging system consisting of a focal-plane array (FPA) containing bi-material cantilever pixels made of silicon nitride (SiNx) and gold (Au), which serve as infrared absorbers and thermomechanical transducers. Based on wave optics, a visible optical readout system is designed to simultaneously measure the deflections of all the cantilever beams in the FPA and project the visible deflection map onto a visible charge-coupled device (CCD) imager. The IR imaging results suggest that the detection resolution of current design is 3-5 K, whereas noise analysis indicates the current resolution to be around 1 K. The noise analysis also shows that the theoretical noise-equivalent temperature difference (NETD) of the system can be below 3 mK.
Applied Physics Letters | 2002
John Kitching; Svenja Knappe; Leo W. Hollberg
We propose a sub-millimeter-scale vapor-cell atomic-frequency reference based on a micromachined vapor cell, all-optical excitation, and advanced diode-laser technology. We analyze theoretically the performance of such a device as a function of cell size. Initial measurements on small-scale vapor cells support the theoretical treatment.
Journal of The Optical Society of America B-optical Physics | 2003
J. Ye; Jin Long Peng; R. Jason Jones; Kevin W. Holman; John L. Hall; David J. Jones; Scott A. Diddams; John Kitching; S Bize; James C. Bergquist; Leo W. Hollberg; Lennart Robertsson; L . Ma
Optical and radio frequency standards located in JILA and National Institute of Standards and Technology (NIST) laboratories have been connected through a 3.45-km optical fiber link. An optical frequency standard based on an iodine-stabilized Nd:YAG laser at 1064 nm (with an instability of ∼4×10-14 at 1 s) has been transferred from JILA to NIST and simultaneously measured in both laboratories. In parallel, a hydrogen maser-based radio frequency standard (with an instability of ∼2.4×10-13 at 1 s) is transferred from NIST to JILA. Comparison between these frequency standards is made possible by the use of femtosecond frequency combs in both laboratories. The degradation of the optical and rf standards that are due to the instability in the transmission channel has been measured. Active noise cancellation is demonstrated to improve the transfer stability of the fiber link.
Optics Letters | 2005
Svenja Knappe; Vladislav Gerginov; Peter D. D. Schwindt; Vishal Shah; Hugh Robinson; Leo W. Hollberg; John Kitching
A novel technique for microfabricating alkali atom vapor cells is described in which alkali atoms are evaporated into a micromachined cell cavity through a glass nozzle. A cell of interior volume 1 mm3, containing 87Rb and a buffer gas, was made in this way and integrated into an atomic clock based on coherent population trapping. A fractional frequency instability of 6 x 10(-12) at 1000 s of integration was measured. The long-term drift of the F=1, mF=0-->F=2, mF=0 hyperfine frequency of atoms in these cells is below 5 x 10(-11)/day.
Optics Express | 2005
Svenja Knappe; Peter D. D. Schwindt; Vishal Shah; Leo W. Hollberg; John Kitching; Li-Anne Liew; John M. Moreland
We demonstrate a microfabricated atomic clock physics package based on coherent population trapping (CPT) on the D1 line of 87Rb atoms. The package occupies a volume of 12 mm3 and requires 195 mW of power to operate at an ambient temperature of 200 degrees C. Compared to a previous microfabricated clock exciting the D2 transition in Cs [1], this 87Rb clock shows significantly improved short- and long-term stability. The instability at short times is 4 x?10-11 / tau?/2 and the improvement over the Cs device is due mainly to an increase in resonance amplitude. At longer times (tau?> 50 s), the improvement results from the reduction of a slow drift to ?5 x 10-9 / day. The drift is most likely caused by a chemical reaction of nitrogen and barium inside the cell. When probing the atoms on the D1 line, spin-exchange collisions between Rb atoms and optical pumping appear to have increased importance compared to the D2 line.
Optics Letters | 2002
M. Stähler; R. Wynands; Svenja Knappe; John Kitching; Leo W. Hollberg; Aleksei V. Taichenachev; V. I. Yudin
We have compared coherent population trapping (CPT) resonances, both experimentally and theoretically, for excitation of the D(1) and D(2) transitions of thermal (85)Rb vapor. Excitation of the D(1) line results in greater resonance contrast than excitation of the D(2) line and in a reduction in the resonance width, in agreement with theoretical expectations. These results translate into a nearly tenfold improvement in performance for the application of CPT resonances to a frequency standard or a sensitive magnetometer when the D(1) line, rather than the D(2) line, is used.
Biomedical Optics Express | 2012
Tilmann Sander; Jan Preusser; Rahul Mhaskar; John Kitching; Lutz Trahms; Svenja Knappe
We report on the measurement of somatosensory-evoked and spontaneous magnetoencephalography (MEG) signals with a chip-scale atomic magnetometer (CSAM) based on optical spectroscopy of alkali atoms. The uncooled, fiber-coupled CSAM has a sensitive volume of 0.77 mm3 inside a sensor head of volume 1 cm3 and enabled convenient handling, similar to an electroencephalography (EEG) electrode. When positioned over O1 of a healthy human subject, α-oscillations were observed in the component of the magnetic field perpendicular to the scalp surface. Furthermore, by stimulation at the right wrist of the subject, somatosensory-evoked fields were measured with the sensors placed over C3. Higher noise levels of the CSAM were partly compensated by higher signal amplitudes due to the shorter distance between CSAM and scalp.
Applied Physics Letters | 2007
Peter D. D. Schwindt; Brad Lindseth; Svenja Knappe; Vishal Shah; John Kitching; Li-Anne Liew
The fabrication and performance of a miniature optically pumped atomic magnetometer constructed with microfabricated components are discussed. This device measures the spin precession frequency of Rb87 atoms to determine the magnetic field by use of the Mx technique. It has a demonstrated sensitivity to magnetic fields of 5pT∕Hz1∕2 for a bandwidth from 1to100Hz, nearly an order of magnitude improvement over our previous chip-scale magnetometer. The 3dB bandwidth has also been increased to 1kHz by reconfiguring the miniature vapor cell heater.