Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where John Notte is active.

Publication


Featured researches published by John Notte.


Journal of Vacuum Science & Technology B | 2006

Helium ion microscope: A new tool for nanoscale microscopy and metrology

Billy W. Ward; John Notte; Nicholas P. Economou

ALIS Corporation has developed a new helium ion microscope which has many advantages over both traditional scanning electron microscopes (SEMs) and focused ion beams (FIBs). This new technology is expected to produce an ultimate focused spot size of 0.25nm. This high resolution is attributed to the high source brightness (B>4×109A∕cm2sr), low energy spread (ΔE∕E∼2×10−5), and small diffraction effects (λ∼80fm). The interaction of helium ions with matter offers several valuable contrast mechanisms and a surface interaction volume which is much smaller than a SEM or conventional FIB.


Journal of Vacuum Science & Technology B | 2009

Subsurface damage from helium ions as a function of dose, beam energy, and dose rate

Richard H. Livengood; Shida Tan; Yuval Greenzweig; John Notte; Shawn McVey

In recent years, helium ion microscopy has produced high resolution images with novel contrast mechanisms. However, when using any charged particle beam, one must consider the potential for sample damage. In this article, the authors will consider helium ion induced damage thresholds as compared to other more traditional charged-particle-beam technologies, as a function of dose, dose rate, and beam energy, and describe potential applications operating regimes.


Nano Letters | 2011

Neon Ion Beam Lithography (NIBL)

Donald Winston; Vitor R. Manfrinato; Samuel M. Nicaise; Lin Lee Cheong; Huigao Duan; David C. Ferranti; Jeff Marshman; Shawn McVey; Lewis Stern; John Notte; Karl K. Berggren

Existing techniques for electron- and ion-beam lithography, routinely employed for nanoscale device fabrication and mask/mold prototyping, do not simultaneously achieve efficient (low fluence) exposure and high resolution. We report lithography using neon ions with fluence <1 ion/nm(2), ∼1000× more efficient than using 30 keV electrons, and resolution down to 7 nm half-pitch. This combination of resolution and exposure efficiency is expected to impact a wide array of fields that are dependent on beam-based lithography.


Scanning | 2012

The history and development of the helium ion microscope

Nicholas P. Economou; John Notte; William Thompson

The helium ion microscope has recently emerged as a commercially available instrument. However, its roots go back more than 60 years to the development of the field ion microscope in Berlin, first reported in 1951. Over the intervening years, numerous researchers have pursued the development of a gas field ionization source with the goal of producing a suitable source for an ion microscope. This proved to be an elusive goal until early in this century when a number of discoveries led to a successful source, and shortly thereafter, an instrument fully able to exploit its advantages. Many individuals and many technical advances have come together to make this new class of microscope. The long history of this quest is reviewed along with the recent advances that led to the achievement of this milestone. A brief summary of the current status of the technology and its applications are given.


Scanning | 2012

The Prospects of a Subnanometer Focused Neon Ion Beam

Fhm-Faridur Rahman; Shawn McVey; Louis S. Farkas; John Notte; Shida Tan; Richard H. Livengood

The success of the helium ion microscope has encouraged extensions of this technology to produce beams of other ion species. A review of the various candidate ion beams and their technical prospects suggest that a neon beam might be the most readily achieved. Such a neon beam would provide a sputtering yield that exceeds helium by an order of magnitude while still offering a theoretical probe size less than 1-nm. This article outlines the motivation for a neon gas field ion source, the expected performance through simulations, and provides an update of our experimental progress.


Journal of Vacuum Science & Technology B | 2009

Understanding imaging modes in the helium ion microscope

Larry Scipioni; Colin A. Sanford; John Notte; Bill Thompson; Shawn McVey

Recent investigations are gaining us a better understanding of the nature of the beam-sample interactions in the helium ion microscope and what they mean for the image information provided. In secondary electron (SE) imaging, for example, the surface sensitivity is attributed to the low SE-II fraction. Voltage contrast imaging shows the ability to see both buried structures and to probe the conductance to ground of surface contacts. It is found, however, that the prominence of these two types of contrast varies oppositely with beam energy, yielding information about the nature of the interactions that gives rise to them. Transmission ion imaging can yield information about material density, atomic number, grain structure, and electronic structure. It is possible to capture the top-side SE signal, bright field signal, and dark field signal from a given sample simultaneously. The detection of diffraction contrast is under investigation.


Journal of Vacuum Science & Technology B | 2007

Membrane folding by helium ion implantation for three-dimensional device fabrication

William J. Arora; Sybren Sijbrandij; Lewis Stern; John Notte; Henry I. Smith; George Barbastathis

The authors demonstrate that silicon nitride membranes can be folded out of plane into three-dimensional structures by helium ion implantation. The folds have a radius of 1μm and can be directed both up or down by varying implant energy.


Journal of Vacuum Science & Technology. B. Nanotechnology and Microelectronics: Materials, Processing, Measurement, and Phenomena | 2010

Gas field ion source and liquid metal ion source charged particle material interaction study for semiconductor nanomachining applications

Shida Tan; Richard H. Livengood; Darryl Shima; John Notte; Shawn McVey

Semiconductor manufacturing technology nodes will evolve to the 22, 15, and 11 nm generations in the next few years. For semiconductor nanomachining applications, further beam spot size scaling is required beyond what is capable by present generation Ga+ focused ion beam technology. As a result, continued Ga+ beam scaling and/or alternative beam technology innovations will be required. In this work, several alternative ion beam technologies are explored and compared to Ga+ beam for key nanomachining and substrate interaction attributes. First, thorough Monte Carlo simulations were conducted with various ion species incident on silicon and copper. Additionally, silicon and copper substrates were experimentally exposed to ion beams of helium, neon, and gallium. These substrates were subsequently analyzed to determine the sputter yields and subsurface damage.


Journal of Vacuum Science & Technology B | 2008

Elemental analysis with the helium ion microscope

Sybren Sijbrandij; Bill Thompson; John Notte; Bill Ward; Nicholas P. Economou

The newly developed helium ion microscope is an instrument well suited to high resolution surface specific imaging with several unique contrast mechanisms. In addition to its imaging capabilities, the focused helium ion beam (subnanometer in size) has recently been used for elemental analysis. The scattering probability, angular distribution, and recoil energy combine to provide valuable information about the specimen being analyzed.


Journal of Vacuum Science & Technology. B. Nanotechnology and Microelectronics: Materials, Processing, Measurement, and Phenomena | 2010

Analysis and metrology with a focused helium ion beama)

Sybren Sijbrandij; John Notte; Larry Scipioni; Chuong Huynh; Colin A. Sanford

The newly introduced ORION™ helium ion microscope has been used for high resolution imaging and nanofabrication. More recently, an energy sensitive detector has been developed that permits the measurement of the energy spectrum of the backscattered helium ions. The spectra can be analyzed directly or compared with the simulated spectra from hypothetical models of the specimen. The technique can provide information about the elemental composition of the specimen or structural information (for example, layer thickness) of the specimen.

Collaboration


Dive into the John Notte's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge