Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Jonathan L. King is active.

Publication


Featured researches published by Jonathan L. King.


Forensic Science International-genetics | 2016

Evaluation of the Illumina® Beta Version ForenSeq™ DNA Signature Prep Kit for use in genetic profiling

Jennifer D. Churchill; Sarah E. Schmedes; Jonathan L. King; Bruce Budowle

While capillary electrophoresis-based technologies have been the mainstay for human identity typing applications, there are limitations with this methodologys resolution, scalability, and throughput. Massively parallel sequencing (MPS) offers the capability to multiplex multiple types of forensically-relevant markers and multiple samples together in one run all at an overall lower cost per nucleotide than traditional capillary electrophoresis-based methods; thus, addressing some of these limitations. MPS also is poised to expand forensic typing capabilities by providing new strategies for mixture deconvolution with the identification of intra-STR allele sequence variants and the potential to generate new types of investigative leads with an increase in the overall number and types of genetic markers being analyzed. The beta version of the Illumina ForenSeq DNA Signature Prep Kit is a MPS library preparation method with a streamlined workflow that allows for targeted amplification and sequencing of 63 STRs and 95 identity SNPs, with the option to include an additional 56 ancestry SNPs and 22 phenotypic SNPs depending on the primer mix chosen for amplification, on the MiSeq desktop sequencer (Illumina). This study was divided into a series of experiments that evaluated reliability, sensitivity of detection, mixture analysis, concordance, and the ability to analyze challenged samples. Genotype accuracy, depth of coverage, and allele balance were used as informative metrics for the quality of the data produced. The ForenSeq DNA Signature Prep Kit produced reliable, reproducible results and obtained full profiles with DNA input amounts of 1ng. Data were found to be concordant with current capillary electrophoresis methods, and mixtures at a 1:19 ratio were resolved accurately. Data from the challenged samples showed concordant results with current DNA typing methods with markers in common and minimal allele drop out from the large number of markers typed on these samples. This set of experiments indicates the beta version of the ForenSeq DNA Signature Prep Kit is a valid tool for forensic DNA typing and warrants full validation studies of this MPS technology.


Forensic Science International-genetics | 2014

High-quality and high-throughput massively parallel sequencing of the human mitochondrial genome using the Illumina MiSeq

Jonathan L. King; Bobby L. LaRue; Nicole M.M. Novroski; Monika Stoljarova; Seung Bum Seo; Xiangpei Zeng; David H. Warshauer; Carey Davis; Walther Parson; Antti Sajantila; Bruce Budowle

Mitochondrial DNA typing in forensic genetics has been performed traditionally using Sanger-type sequencing. Consequently sequencing of a relatively-large target such as the mitochondrial genome (mtGenome) is laborious and time consuming. Thus, sequencing typically focuses on the control region due to its high concentration of variation. Massively parallel sequencing (MPS) has become more accessible in recent years allowing for high-throughput processing of large target areas. In this study, Nextera(®) XT DNA Sample Preparation Kit and the Illumina MiSeq™ were utilized to generate quality whole genome mitochondrial haplotypes from 283 individuals in a both cost-effective and rapid manner. Results showed that haplotypes can be generated at a high depth of coverage with limited strand bias. The distribution of variants across the mitochondrial genome was described and demonstrated greater variation within the coding region than the non-coding region. Haplotype and haplogroup diversity were described with respect to whole mtGenome and HVI/HVII. An overall increase in haplotype or genetic diversity and random match probability, as well as better haplogroup assignment demonstrates that MPS of the mtGenome using the Illumina MiSeq system is a viable and reliable methodology.


Forensic Science International-genetics | 2013

STRait Razor: a length-based forensic STR allele-calling tool for use with second generation sequencing data.

David H. Warshauer; David Lin; Kumar Hari; Ravi Jain; Carey Davis; Bobby L. LaRue; Jonathan L. King; Bruce Budowle

Recent studies have demonstrated the capability of second generation sequencing (SGS) to provide coverage of short tandem repeats (STRs) found within the human genome. However, there are relatively few bioinformatic software packages capable of detecting these markers in the raw sequence data. The extant STR-calling tools are sophisticated, but are not always applicable to the analysis of the STR loci commonly used in forensic analyses. STRait Razor is a newly developed Perl-based software tool that runs on the Linux/Unix operating system and is designed to detect forensically-relevant STR alleles in FASTQ sequence data, based on allelic length. It is capable of analyzing STR loci with repeat motifs ranging from simple to complex without the need for extensive allelic sequence data. STRait Razor is designed to interpret both single-end and paired-end data and relies on intelligent parallel processing to reduce analysis time. Users are presented with a number of customization options, including variable mismatch detection parameters, as well as the ability to easily allow for the detection of alleles at new loci. In its current state, the software detects alleles for 44 autosomal and Y-chromosome STR loci. The study described herein demonstrates that STRait Razor is capable of detecting STR alleles in data generated by multiple library preparation methods and two Illumina(®) sequencing instruments, with 100% concordance. The data also reveal noteworthy concepts related to the effect of different preparation chemistries and sequencing parameters on the bioinformatic detection of STR alleles.


Forensic Science International-genetics | 2016

Massively parallel sequencing of forensic STRs: Considerations of the DNA commission of the International Society for Forensic Genetics (ISFG) on minimal nomenclature requirements

Walther Parson; David Ballard; Bruce Budowle; John M. Butler; Katherine Butler Gettings; Peter Gill; Leonor Gusmão; Douglas R. Hares; Jodi A. Irwin; Jonathan L. King; Peter de Knijff; Niels Morling; Mechthild Prinz; Peter M. Schneider; Christophe Van Neste; Sascha Willuweit; C. Phillips

The DNA Commission of the International Society for Forensic Genetics (ISFG) is reviewing factors that need to be considered ahead of the adoption by the forensic community of short tandem repeat (STR) genotyping by massively parallel sequencing (MPS) technologies. MPS produces sequence data that provide a precise description of the repeat allele structure of a STR marker and variants that may reside in the flanking areas of the repeat region. When a STR contains a complex arrangement of repeat motifs, the level of genetic polymorphism revealed by the sequence data can increase substantially. As repeat structures can be complex and include substitutions, insertions, deletions, variable tandem repeat arrangements of multiple nucleotide motifs, and flanking region SNPs, established capillary electrophoresis (CE) allele descriptions must be supplemented by a new system of STR allele nomenclature, which retains backward compatibility with the CE data that currently populate national DNA databases and that will continue to be produced for the coming years. Thus, there is a pressing need to produce a standardized framework for describing complex sequences that enable comparison with currently used repeat allele nomenclature derived from conventional CE systems. It is important to discern three levels of information in hierarchical order (i) the sequence, (ii) the alignment, and (iii) the nomenclature of STR sequence data. We propose a sequence (text) string format the minimal requirement of data storage that laboratories should follow when adopting MPS of STRs. We further discuss the variant annotation and sequence comparison framework necessary to maintain compatibility among established and future data. This system must be easy to use and interpret by the DNA specialist, based on a universally accessible genome assembly, and in place before the uptake of MPS by the general forensic community starts to generate sequence data on a large scale. While the established nomenclature for CE-based STR analysis will remain unchanged in the future, the nomenclature of sequence-based STR genotypes will need to follow updated rules and be generated by expert systems that translate MPS sequences to match CE conventions in order to guarantee compatibility between the different generations of STR data.


Forensic Science International-genetics | 2015

High sensitivity multiplex short tandem repeat loci analyses with massively parallel sequencing

Xiangpei Zeng; Jonathan L. King; Monika Stoljarova; David H. Warshauer; Bobby L. LaRue; Antti Sajantila; Jaynish Patel; Douglas R. Storts; Bruce Budowle

STR typing in forensic genetics has been performed traditionally using capillary electrophoresis (CE). However, CE-based method has some limitations: a small number of STR loci can be used; stutter products, dye artifacts and low level alleles. Massively parallel sequencing (MPS) has been considered a viable technology in recent years allowing high-throughput coverage at a relatively affordable price. Some of the CE-based limitations may be overcome with the application of MPS. In this study, a prototype multiplex STR System (Promega) was amplified and prepared using the TruSeq DNA LT Sample Preparation Kit (Illumina) in 24 samples. Results showed that the MinElute PCR Purification Kit (Qiagen) was a better size selection method compared with recommended diluted bead mixtures. The library input sensitivity study showed that a wide range of amplicon product (6-200ng) could be used for library preparation without apparent differences in the STR profile. PCR sensitivity study indicated that 62pg may be minimum input amount for generating complete profiles. Reliability study results on 24 different individuals showed that high depth of coverage (DoC) and balanced heterozygote allele coverage ratios (ACRs) could be obtained with 250pg of input DNA, and 62pg could generate complete or nearly complete profiles. These studies indicate that this STR multiplex system and the Illumina MiSeq can generate reliable STR profiles at a sensitivity level that competes with current widely used CE-based method.


Forensic Science International-genetics | 2015

STRait Razor v2.0: The improved STR Allele Identification Tool - Razor

David H. Warshauer; Jonathan L. King; Bruce Budowle

STRait Razor (the STR Allele Identification Tool - Razor) was developed as a bioinformatic software tool to detect short tandem repeat (STR) alleles in massively parallel sequencing (MPS) raw data. The method of detection used by STRait Razor allows it to make reliable allele calls for all STR types in a manner that is similar to that of capillary electrophoresis. STRait Razor v2.0 incorporates several new features and improvements upon the original software, such as a larger default locus configuration file that increases the number of detectable loci (now including X-chromosome STRs and Amelogenin), an enhanced custom locus list generator, a novel output sorting method that highlights unique sequences for intra-repeat variation detection, and a genotyping tool that emulates traditional electropherogram data. Users also now have the option to choose whether the program detects autosomal, X-chromosome, Y-chromosome, or all STRs. Concordance testing was performed, and allele calls produced by STRait Razor v2.0 were completely consistent with those made by the original software.


Forensic Science International-genetics | 2014

Internal validation of the GlobalFiler™ Express PCR Amplification Kit for the direct amplification of reference DNA samples on a high-throughput automated workflow

Shahida Flores; Jie Sun; Jonathan L. King; Bruce Budowle

The GlobalFiler™ Express PCR Amplification Kit uses 6-dye fluorescent chemistry to enable multiplexing of 21 autosomal STRs, 1 Y-STR, 1 Y-indel and the sex-determining marker amelogenin. The kit is specifically designed for processing reference DNA samples in a high throughput manner. Validation studies were conducted to assess the performance and define the limitations of this direct amplification kit for typing blood and buccal reference DNA samples on various punchable collection media. Studies included thermal cycling sensitivity, reproducibility, precision, sensitivity of detection, minimum detection threshold, system contamination, stochastic threshold and concordance. Results showed that optimal amplification and injection parameters for a 1.2mm punch from blood and buccal samples were 27 and 28 cycles, respectively, combined with a 12s injection on an ABI 3500xL Genetic Analyzer. Minimum detection thresholds were set at 100 and 120RFUs for 27 and 28 cycles, respectively, and it was suggested that data from positive amplification controls provided a better threshold representation. Stochastic thresholds were set at 250 and 400RFUs for 27 and 28 cycles, respectively, as stochastic effects increased with cycle number. The minimum amount of input DNA resulting in a full profile was 0.5ng, however, the optimum range determined was 2.5-10ng. Profile quality from the GlobalFiler™ Express Kit and the previously validated AmpFlSTR(®) Identifiler(®) Direct Kit was comparable. The validation data support that reliable DNA typing results from reference DNA samples can be obtained using the GlobalFiler™ Express PCR Amplification Kit.


Forensic Science International-genetics | 2016

Characterization of genetic sequence variation of 58 STR loci in four major population groups

Nicole M.M. Novroski; Jonathan L. King; Jennifer D. Churchill; Lay Hong Seah; Bruce Budowle

Massively parallel sequencing (MPS) can identify sequence variation within short tandem repeat (STR) alleles as well as their nominal allele lengths that traditionally have been obtained by capillary electrophoresis. Using the MiSeq FGx Forensic Genomics System (Illumina), STRait Razor, and in-house excel workbooks, genetic variation was characterized within STR repeat and flanking regions of 27 autosomal, 7 X-chromosome and 24 Y-chromosome STR markers in 777 unrelated individuals from four population groups. Seven hundred and forty six autosomal, 227 X-chromosome, and 324 Y-chromosome STR alleles were identified by sequence compared with 357 autosomal, 107 X-chromosome, and 189 Y-chromosome STR alleles that were identified by length. Within the observed sequence variation, 227 autosomal, 156 X-chromosome, and 112 Y-chromosome novel alleles were identified and described. One hundred and seventy six autosomal, 123 X-chromosome, and 93 Y-chromosome sequence variants resided within STR repeat regions, and 86 autosomal, 39 X-chromosome, and 20 Y-chromosome variants were located in STR flanking regions. Three markers, D18S51, DXS10135, and DYS385a-b had 1, 4, and 1 alleles, respectively, which contained both a novel repeat region variant and a flanking sequence variant in the same nucleotide sequence. There were 50 markers that demonstrated a relative increase in diversity with the variant sequence alleles compared with those of traditional nominal length alleles. These population data illustrate the genetic variation that exists in the commonly used STR markers in the selected population samples and provide allele frequencies for statistical calculations related to STR profiling with MPS data.


Forensic Science International-genetics | 2015

An evaluation of the PowerSeq™ Auto System: A multiplex short tandem repeat marker kit compatible with massively parallel sequencing

Xiangpei Zeng; Jonathan L. King; Spencer Hermanson; Jaynish Patel; Douglas R. Storts; Bruce Budowle

Capillary electrophoresis (CE) and multiplex amplification with fluorescent tagging have been routinely used for STR typing in forensic genetics. However, CE-based methods restrict the number of markers that can be multiplexed simultaneously and cannot detect any intra-repeat variations within STRs. Several studies already have indicated that massively parallel sequencing (MPS) may be another potential technology for STR typing. In this study, the prototype PowerSeq(™) Auto System (Promega) containing the 23 STR loci and amelogenin was evaluated using Illumina MiSeq. Results showed that single source complete profiles could be obtained using as little as 62 pg of input DNA. The reproducibility study showed that the profiles generated were consistent among multiple typing experiments for a given individual. The mixture study indicated that partial STR profiles of the minor contributor could be detected up to 19:1 mixture. The mock forensic casework study showed that full or partial profiles could be obtained from different types of single source and mixture samples. These studies indicate that the PowerSeq Auto System and the Illumina MiSeq can generate concordant results with current CE-based methods. In addition, MPS-based systems can facilitate mixture deconvolution with the detection of intra-repeat variations within length-based STR alleles.


Croatian Medical Journal | 2015

Blind study evaluation illustrates utility of the Ion PGM™ system for use in human identity DNA typing

Jennifer D. Churchill; Joseph Chang; Jianye Ge; Narasimhan Rajagopalan; Sharon Wootton; Chien-Wei Chang; Robert Lagace; Wenchi Liao; Jonathan L. King; Bruce Budowle

Aim To perform a blind study to assess the capability of the Ion Personal Genome Machine™ (PGM) system to sequence forensically relevant genetic marker panels and to characterize unknown individuals for ancestry and possible relatedness. Methods Twelve genomic samples were provided by a third party for blinded genetic analysis. For these 12 samples, the mitochondrial genome and three PGM™ panels containing human identity single nucleotide polymorphisms (SNPs), ancestry informative SNPs, and short tandem repeats (STRs) were sequenced on the PGM™ system and analyzed. Results All four genetic systems were run and analyzed on the PGM™ system in a reasonably quick time frame. Completeness of genetic profiles, depth of coverage, strand balance, and allele balance were informative metrics that illustrated the quality and reliability of the data produced. SNP genotypes allowed for identification of sex, paternal lineage, and population ancestry. STR genotypes were shown to be in complete concordance with genotypes generated by standard capillary electrophoresis-based technologies. Variants in the mitochondrial genome data provided information on population background and maternal relationships. Conclusion All results from analysis of the 12 genomic samples were consistent with sample information provided by the sample providers at the end of the blinded study. The relatively easy identification of intra-STR allele SNPs offered the potential for increased discrimination power. The promising nature of these results warrants full validation studies of this massively parallel sequencing technology and its further development for forensic data analysis.

Collaboration


Dive into the Jonathan L. King's collaboration.

Top Co-Authors

Avatar

Bruce Budowle

University of North Texas Health Science Center

View shared research outputs
Top Co-Authors

Avatar

Jennifer D. Churchill

University of North Texas Health Science Center

View shared research outputs
Top Co-Authors

Avatar

Bobby L. LaRue

University of North Texas Health Science Center

View shared research outputs
Top Co-Authors

Avatar

David H. Warshauer

University of North Texas Health Science Center

View shared research outputs
Top Co-Authors

Avatar

Xiangpei Zeng

University of North Texas Health Science Center

View shared research outputs
Top Co-Authors

Avatar

Nicole M.M. Novroski

University of North Texas Health Science Center

View shared research outputs
Top Co-Authors

Avatar

Jianye Ge

University of North Texas Health Science Center

View shared research outputs
Top Co-Authors

Avatar

Carey Davis

University of North Texas Health Science Center

View shared research outputs
Top Co-Authors

Avatar

Frank R. Wendt

University of North Texas Health Science Center

View shared research outputs
Top Co-Authors

Avatar

Pamela L. Marshall

University of North Texas Health Science Center

View shared research outputs
Researchain Logo
Decentralizing Knowledge