Jordi Franch
Autonomous University of Barcelona
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Jordi Franch.
Veterinary Journal | 2011
Cristina Costa-Farré; Xavier Sala Blanch; J. Ignacio Cruz; Jordi Franch
The aim of this study was to investigate the use of ultrasound (US) guidance to perform sciatic and saphenous nerve blocks in dogs. Five dogs were sedated with medetomidine and butorphanol. A high-resolution US transducer was used to locate the nerves, guide placement of the needle and visualise the perineural injection of lidocaine 2%. Electrostimulation was used to confirm correct placement prior to the sciatic block. Nerve functions were evaluated over a 3 h period following administration of atipamezole. Successful identification of the nerves and the quality of the blocks were recorded. Location of the nerves, complete sensory block of the saphenous nerve, and partial to complete sensory and motor blocks of the sciatic nerve were achieved in all dogs. The resultant US guidance is potentially valuable for blocking the sciatic and saphenous nerves in dogs, although further work will be required to ensure a complete block of the sciatic nerve.
ACS Applied Materials & Interfaces | 2017
Albert Barba; Anna Diez-Escudero; Yassine Maazouz; Katrin Rappe; Montserrat Espanol; Edgar B. Montufar; Mar Bonany; Joanna M. Sadowska; Jordi Guillem-Marti; Caroline Öhman-Mägi; Cecilia Persson; Maria-Cristina Manzanares; Jordi Franch; Maria-Pau Ginebra
Some biomaterials are osteoinductive, that is, they are able to trigger the osteogenic process by inducing the differentiation of mesenchymal stem cells to the osteogenic lineage. Although the underlying mechanism is still unclear, microporosity and specific surface area (SSA) have been identified as critical factors in material-associated osteoinduction. However, only sintered ceramics, which have a limited range of porosities and SSA, have been analyzed so far. In this work, we were able to extend these ranges to the nanoscale, through the foaming and 3D-printing of biomimetic calcium phosphates, thereby obtaining scaffolds with controlled micro- and nanoporosity and with tailored macropore architectures. Calcium-deficient hydroxyapatite (CDHA) scaffolds were evaluated after 6 and 12 weeks in an ectopic-implantation canine model and compared with two sintered ceramics, biphasic calcium phosphate and β-tricalcium phosphate. Only foams with spherical, concave macropores and not 3D-printed scaffolds with convex, prismatic macropores induced significant ectopic bone formation. Among them, biomimetic nanostructured CDHA produced the highest incidence of ectopic bone and accelerated bone formation when compared with conventional microstructured sintered calcium phosphates with the same macropore architecture. Moreover, they exhibited different bone formation patterns; in CDHA foams, the new ectopic bone progressively replaced the scaffold, whereas in sintered biphasic calcium phosphate scaffolds, bone was deposited on the surface of the material, progressively filling the pore space. In conclusion, this study demonstrates that the high reactivity of nanostructured biomimetic CDHA combined with a spherical, concave macroporosity allows the pushing of the osteoinduction potential beyond the limits of microstructured calcium phosphate ceramics.
PLOS ONE | 2015
Erika Cuzmar; Roman A. Perez; Maria-Cristina Manzanares; Maria-Pau Ginebra; Jordi Franch
The osteogenic capacity of biomimetic calcium deficient hydroxyapatite microspheres with and without collagen obtained by emulsification of a calcium phosphate cement paste has been evaluated in an in vivo model, and compared with an injectable calcium phosphate cement with the same composition. The materials were implanted into a 5 mm defect in the femur condyle of rabbits, and bone formation was assessed after 1 and 3 months. The histological analysis revealed that the cements presented cellular activity only in the margins of the material, whereas each one of the individual microspheres was covered with osteogenic cells. Consequently, bone ingrowth was enhanced by the microspheres, with a tenfold increase compared to the cement, which was associated to the higher accessibility for the cells provided by the macroporous network between the microspheres, and the larger surface area available for osteoconduction. No significant differences were found in terms of bone formation associated with the presence of collagen in the materials, although a more extensive erosion of the collagen-containing microspheres was observed.
Biomedical Materials | 2017
S. Lewin; Albert Barba; Cecilia Persson; Jordi Franch; Maria-Pau Ginebra; Caroline Öhman-Mägi
There is a plethora of calcium phosphate (CaP) scaffolds used as synthetic substitutes to bone grafts. The scaffold performance is often evaluated from the quantity of bone formed within or in direct contact with the scaffold. Micro-computed tomography (μCT) allows three-dimensional evaluation of bone formation inside scaffolds. However, the almost identical x-ray attenuation of CaP and bone obtrude the separation of these phases in μCT images. Commonly, segmentation of bone in μCT images is based on gray scale intensity, with manually determined global thresholds. However, image analysis methods, and methods for manual thresholding in particular, lack standardization and may consequently suffer from subjectivity. The aim of the present study was to provide a methodological framework for addressing these issues. Bone formation in two types of CaP scaffold architectures (foamed and robocast), obtained from a larger animal study (a 12 week canine animal model) was evaluated by μCT. In addition, cross-sectional scanning electron microscopy (SEM) images were acquired as references to determine thresholds and to validate the result. μCT datasets were registered to the corresponding SEM reference. Global thresholds were then determined by quantitatively correlating the different area fractions in the μCT image, towards the area fractions in the corresponding SEM image. For comparison, area fractions were also quantified using global thresholds determined manually by two different approaches. In the validation the manually determined thresholds resulted in large average errors in area fraction (up to 17%), whereas for the evaluation using SEM references, the errors were estimated to be less than 3%. Furthermore, it was found that basing the thresholds on one single SEM reference gave lower errors than determining them manually. This study provides an objective, robust and less error prone method to determine global thresholds for the evaluation of bone formation in CaP scaffolds.
International Journal of Molecular Sciences | 2018
Mónica Ortiz-Hernandez; Katrin Rappe; Meritxell Molmeneu; Carles Mas-Moruno; Jordi Guillem-Marti; Miquel Punset; Cristina Caparrós; José Antonio Calero; Jordi Franch; Mariano Fernandez-Fairen; Javier Gil
In this study, highly-interconnected porous titanium implants were produced by powder sintering with different porous diameters and open interconnectivity. The actual foams were produced using high cost technologies: Chemical Vapor Deposition (CVD), Physical Vapor Deposition (PVD), and spark plasma sintering, and the porosity and/or interconnection was not optimized. The aim was to generate a bioactive surface on foams using two different strategies, based on inorganic thermo-chemical treatment and organic coating by peptide adsorption, to enhance osseointegration. Porosity was produced using NaCl as a space holder and polyethyleneglicol as a binder phase. Static and fatigue tests were performed in order to determine mechanical behaviors. Surface bioactivation was performed using a thermo-chemical treatment or by chemical adsorption with peptides. Osteoblast-like cells were cultured and cytotoxicity was measured. Bioactivated scaffolds and a control were implanted in the tibiae of rabbits. Histomorphometric evaluation was performed at 4 weeks after implantation. Interconnected porosity was 53% with an average diameter of 210 µm and an elastic modulus of around 1 GPa with good mechanical properties. The samples presented cell survival values close to 100% of viability. Newly formed bone was observed inside macropores, through interconnected porosity, and on the implant surface. Successful bone colonization of inner structure (40%) suggested good osteoconductive capability of the implant. Bioactivated foams showed better results than non-treated ones, suggesting both bioactivation strategies induce osteointegration capability.
Acta Biomaterialia | 2018
Albert Barba; Yassine Maazouz; Anna Diez-Escudero; Katrin Rappe; Montserrat Espanol; Edgar B. Montufar; Caroline Öhman-Mägi; Cecilia Persson; Pedro Fontecha; Maria-Cristina Manzanares; Jordi Franch; Maria-Pau Ginebra
There is an urgent need of synthetic bone grafts with enhanced osteogenic capacity. This can be achieved by combining biomaterials with exogenous growth factors, which however can have numerous undesired side effects, but also by tuning the intrinsic biomaterial properties. In a previous study, we showed the synergistic effect of nanostructure and pore architecture of biomimetic calcium deficient hydroxyapatite (CDHA) scaffolds in enhancing osteoinduction, i.e. fostering the differentiation of mesenchymal stem cells to bone forming cells. This was demonstrated by assessing bone formation after implanting the scaffolds intramuscularly. The present study goes one step forward, since it analyzes the effect of the geometrical features of the same CDHA scaffolds, obtained either by 3D-printing or by foaming, on the osteogenic potential and resorption behaviour in a bony environment. After 6 and 12 weeks of intraosseous implantation, both bone formation and material degradation had been drastically affected by the macropore architecture of the scaffolds. Whereas nanostructured CDHA was shown to be highly osteoconductive both in the robocast and foamed scaffolds, a superior osteogenic capacity was observed in the foamed scaffolds, which was associated with their higher intrinsic osteoinductive potential. Moreover, they showed a significantly higher cell-mediated degradation than the robocast constructs, with a simultaneous and progressive replacement of the scaffold by new bone. In conclusion, these results demonstrate that the control of macropore architecture is a crucial parameter in the design of synthetic bone grafts, which allows fostering both material degradation and new bone formation. Statement of Significance 3D-printing technologies open new perspectives for the design of patient-specific bone grafts, since they allow customizing the external shape together with the internal architecture of implants. In this respect, it is important to design the appropriate pore geometry to maximize the bone healing capacity of these implants. The present study analyses the effect of pore architecture of nanostructured hydroxyapatite scaffolds, obtained either by 3D-printing or foaming, on the osteogenic potential and scaffold resorption in an in vivo model. While nanostructured hydroxyapatite showed excellent osteoconductive properties irrespective of pore geometry, we demonstrated that the spherical, concave macropores of foamed scaffolds significantly promoted both material resorption and bone regeneration compared to the 3D-printed scaffolds with orthogonal-patterned struts and therefore prismatic, convex macropores.
Contextos Educativos: Revista de Educación | 2003
Joaquín Gairín Sallán; Dolors Quinquer Vilamitjana; Mònica Feixas; Jordi Franch; Cristina Guillamón
Journal of Exotic Pet Medicine | 2017
Laura Vilalta; Jordi Franch; Jaime Martorell
ED-IADR/NOF Oral Health Research Congress, Vienna | 2017
Albert Barba; Katrin Rappe; P Fontecha; Anna Diez-Escudero; Yassine Maazouz; Montserrat Espanol; Caroline Öhman Mägi; Cecilia Persson; Maria-Cristina Manzanares; Jordi Franch; Maria-Pau Ginebra
29th Bioceramic symposium, Toulouse (France) | 2017
Susanne Lewin; Albert Barba; Cecilia Persson; Jordi Franch; Maria-Pau Ginebra; Caroline Öhman Mägi