PLOS ONE | 2015

Fatigue Performance of Medical Ti6Al4V Alloy after Mechanical Surface Treatments

Robert Sonntag; Jörn Reinders; Jens Gibmeier; J. Philippe Kretzer

Mechanical surface treatments have a long history in traditional engineering disciplines, such as the automotive or aerospace industries. Today, they are widely applied to metal components to increase the mechanical performance of these. However, their application in the medical field is rather rare. The present study aims to compare the potential of relevant mechanical surface treatments on the high cycle fatigue (R = 0.1 for a maximum of 10 million cycles) performance of a Ti6Al4V standard alloy for orthopedic, spinal, dental and trauma surgical implants: shot peening, deep rolling, ultrasonic shot peening and laser shock peening. Hour-glass shaped Ti6Al4V specimens were treated and analyzed with regard to the material’s microstructure, microhardness, residual stress depth profiles and the mechanical behavior during fatigue testing. All treatments introduced substantial compressive residual stresses and exhibited considerable potential for increasing fatigue performance from 10% to 17.2% after laser shock peening compared to non-treated samples. It is assumed that final mechanical surface treatments may also increase fretting wear resistance in the modular connection of total hip and knee replacements.


Acta Biomaterialia | 2013

In vivo serum titanium ion levels following modular neck total hip arthroplasty--10 year results in 67 patients.

G.W. Omlor; Jan Philippe Kretzer; Jörn Reinders; Marcus R. Streit; Thomas Bruckner; Tobias Gotterbarm; P.R. Aldinger; Christian Merle

The objective of the present cross-sectional study was to determine in vivo titanium ion levels following cementless total hip arthroplasty (THA) using a modular stem system with different shapes for femoral canal fit and multiple neck options. A consecutive series of 173 patients (190 hips) who underwent cementless modular neck THA and a ceramic on polyethylene bearing with a median follow-up of 9 (7-13) years was evaluated retrospectively. According to a standardized protocol, titanium ion measurements were performed on 67 patients using high-resolution inductively coupled plasma-mass spectrometry. Ion levels were compared to a control group comprising patients with non-modular titanium implants (n=11) and to individuals without implants (n=23). Modular neck THA did not result in elevated titanium ion levels compared to non-modular THA. Compared to individuals without implants, both modular THA and non-modular THA showed elevated titanium ion levels. Absolute titanium ion levels, however, were comparatively low for both implants. The data suggest that the present modular stem system does not result in elevated systemic titanium ion levels in the medium term when compared to non-modular stems. Further longitudinal studies are needed to evaluate the use of systemic titanium ion levels as an objective diagnostic tool to identify THA failure and to monitor patients following revision surgery.


PLOS ONE | 2013

Hard-on-Hard Lubrication in the Artificial Hip under Dynamic Loading Conditions

Robert Sonntag; Jörn Reinders; Johannes S. Rieger; Daniel W.W. Heitzmann; J. Philippe Kretzer

The tribological performance of an artificial hip joint has a particularly strong influence on its success. The principle causes for failure are adverse short- and long-term reactions to wear debris and high frictional torque in the case of poor lubrication that may cause loosening of the implant. Therefore, using experimental and theoretical approaches models have been developed to evaluate lubrication under standardized conditions. A steady-state numerical model has been extended with dynamic experimental data for hard-on-hard bearings used in total hip replacements to verify the tribological relevance of the ISO 14242-1 gait cycle in comparison to experimental data from the Orthoload database and instrumented gait analysis for three additional loading conditions: normal walking, climbing stairs and descending stairs. Ceramic-on-ceramic bearing partners show superior lubrication potential compared to hard-on-hard bearings that work with at least one articulating metal component. Lubrication regimes during the investigated activities are shown to strongly depend on the kinematics and loading conditions. The outcome from the ISO gait is not fully confirmed by the normal walking data and more challenging conditions show evidence of inferior lubrication. These findings may help to explain the differences between the in vitro predictions using the ISO gait cycle and the clinical outcome of some hard-on-hard bearings, e.g., using metal-on-metal.


Orthopade | 2012

Principles of tribological analysis of endoprostheses

J.P. Kretzer; Carmen Zietz; Christian Schröder; Jörn Reinders; Lars Middelborg; Alexander Paulus; R. Sonntag; Rainer Bader; Sandra Utzschneider

For the tribological characterization of artificial joints, various experimental methods are currently available. However, the in vitro test conditions applied are only comparable in a limited way and transferability to the in vivo situation is also restricted. This is due to the different wear simulation concepts used and partly insufficient simulation of clinical worst case situations. In the present paper current scientific methods and procedures for tribological testing of artificial joints are presented. In addition, the biological effects of wear products are described enabling clinicians to challenge tribological studies and to facilitate specific interpretation of scientific results taking the clinical situation into account.


PLOS ONE | 2013

Wear performance of ceramic-on-metal hip bearings.

Jörn Reinders; Robert Sonntag; Christian Heisel; Tobias Reiner; Leo Vot; Jan Philippe Kretzer

Ceramic-on-metal (CoM) bearings are considered to be a promising alternative to polyethylene-based bearings or hard-on-hard bearings (Ceramic-on-Ceramic (CoC) and Metal-on-Metal (MoM)). Although, CoM shows lower wear rates than MoM, in-vitro wear testing of CoM shows widely varying results. This may be related to limitations of wear-measuring methods. Therefore, the aim of this study was to improve the gravimetric measurement technique and to test wear behaviour of CoM bearings compared to CoC bearings. Level walking according to ISO-14242 was simulated for four CoM and four CoC bearings. Prior to simulation, errors in measurement of gravimetric wear were detected and improvements in measurement technique incorporated. The results showed no differences in mean wear rates between CoM and CoC bearings. However, the CoM bearings showed wear results over a wide range of wear performance. High reliability of wear results was recorded for the CoC bearings. Material transfer was observed on the ceramic heads of the CoM bearings. Therefore, for level walking a partial mixed or boundary lubrication has to be assumed for this type of bearing. CoM is a highly sensitive wear-couple. The reasons for the observed behaviour cannot be clarified from this study. Simulator studies have to be considered as an ideal loading condition. Therefore, high variations in wear rates as seen in this study, even at low levels, may have an adverse effect on the in-vivo wear behavior. Careful clinical use may be advisable until the reasons for the variation are fully clarified and understood.


PLOS ONE | 2015

Wear testing of moderate activities of daily living using in vivo measured knee joint loading.

Jörn Reinders; Robert Sonntag; Leo Vot; Christian Gibney; Moritz Nowack; Jan Philippe Kretzer

Resumption of daily living activities is a basic expectation for patients provided with total knee replacements. However, there is a lack of knowledge regarding the impact of different activities on the wear performance. In this study the wear performance under application of different daily activities has been analyzed. In vivo load data for walking, walking downstairs/upstairs, sitting down/standing up, and cycling (50 W & 120 W) has been standardized for wear testing. Wear testing of each activity was carried out on a knee wear simulator. Additionally, ISO walking was tested for reasons of comparison. Wear was assessed gravimetrically and wear particles were analyzed. In vivo walking produced the highest overall wear rates, which were determined to be three times higher than ISO walking. Moderate wear rates were determined for walking upstairs and downstairs. Low wear rates were determined for standing up/sitting down and cycling at power levels of 50 W and 120 W. The largest wear particles were observed for cycling. Walking based on in vivo data has been shown to be the most wear-relevant activity. Highly demanding activities (stair climbing) produced considerably less wear. Taking into account the expected number of loads, low-impact activities like cycling may have a greater impact on articular wear than highly demanding activities.


BioMed Research International | 2014

Wear Behavior of an Unstable Knee: Stabilization via Implant Design?

Jörn Reinders; Robert Sonntag; Jan Philippe Kretzer

Background. Wear-related failures and instabilities are frequent failure mechanisms of total knee replacements. High-conforming designs may provide additional stability for the joint. This study analyzes the effects of a ligamentous insufficiency on the stability and the wear behavior of a high-conforming knee design. Methods. Two simulator wear tests were performed on a high-conforming total knee replacement design. In the first, a ligamentous-stable knee replacement with a sacrificed anterior cruciate ligament was simulated. In the second, a ligamentous-unstable knee with additionally insufficient posterior cruciate ligament and medial collateral ligament was simulated. Wear was determined gravimetrically and wear particles were analyzed. Implant kinematics was recorded during simulation. Results. Significantly higher wear rates (P ≤ 0.001) were observed for the unstable knee (14.58 ± 0.56 mg/106 cycles) compared to the stable knee (7.97 ± 0.87 mg/106 cycles). A higher number of wear particles with only small differences in wear particle characteristics were observed. Under unstable knee conditions, kinematics increased significantly for translations and rotations (P ≤ 0.01). This increase was mainly attributed to higher tibial posterior translation and internal rotations. Conclusion. Higher kinematics under unstable test conditions is a result of insufficient stabilization via implant design. Due to the higher kinematics, increased wear was observed in this study.


Orthopade | 2012

Grundlagen zur tribologischen Analyse von Endoprothesen

J.P. Kretzer; Carmen Zietz; Christian Schröder; Jörn Reinders; Lars Middelborg; Alexander Paulus; R. Sonntag; Rainer Bader; Sandra Utzschneider

For the tribological characterization of artificial joints, various experimental methods are currently available. However, the in vitro test conditions applied are only comparable in a limited way and transferability to the in vivo situation is also restricted. This is due to the different wear simulation concepts used and partly insufficient simulation of clinical worst case situations. In the present paper current scientific methods and procedures for tribological testing of artificial joints are presented. In addition, the biological effects of wear products are described enabling clinicians to challenge tribological studies and to facilitate specific interpretation of scientific results taking the clinical situation into account.


Orthopade | 2012

Grundlagen zur tribologischen Analyse von Endoprothesen@@@Principles of tribological analysis of endoprostheses

J.P. Kretzer; Carmen Zietz; Christian Schröder; Jörn Reinders; Lars Middelborg; Alexander Paulus; R. Sonntag; Rainer Bader; Sandra Utzschneider

For the tribological characterization of artificial joints, various experimental methods are currently available. However, the in vitro test conditions applied are only comparable in a limited way and transferability to the in vivo situation is also restricted. This is due to the different wear simulation concepts used and partly insufficient simulation of clinical worst case situations. In the present paper current scientific methods and procedures for tribological testing of artificial joints are presented. In addition, the biological effects of wear products are described enabling clinicians to challenge tribological studies and to facilitate specific interpretation of scientific results taking the clinical situation into account.


Acta Biomaterialia | 2013

Characterization of polyethylene wear particle: The impact of methodology

Christian Schröder; Jörn Reinders; Carmen Zietz; Sandra Utzschneider; Rainer Bader; J. Philippe Kretzer

Collaboration


Dive into the Jörn Reinders's collaboration.

Top Co-Authors

Avatar

Robert Sonntag

University Hospital Heidelberg

View shared research outputs
Top Co-Authors

Avatar

Jan Philippe Kretzer

University Hospital Heidelberg

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

J. Philippe Kretzer

University Hospital Heidelberg

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Christian Gibney

University Hospital Heidelberg

View shared research outputs
Top Co-Authors

Avatar

Daniel W.W. Heitzmann

University Hospital Heidelberg

View shared research outputs
Top Co-Authors

Avatar

Leo Vot

University Hospital Heidelberg

View shared research outputs
Top Co-Authors

Avatar

Burkhard Lehner

University Hospital Heidelberg

View shared research outputs
Researchain Logo
Decentralizing Knowledge