Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Joshua R. Woolley is active.

Publication


Featured researches published by Joshua R. Woolley.


Colloids and Surfaces B: Biointerfaces | 2010

Simple surface modification of a titanium alloy with silanated zwitterionic phosphorylcholine or sulfobetaine modifiers to reduce thrombogenicity

Sang Ho Ye; Carl A. Johnson; Joshua R. Woolley; Hironobu Murata; Lara J. Gamble; Kazuhiko Ishihara; William R. Wagner

Thrombosis and thromboembolism remain problematic for a large number of blood contacting medical devices and limit broader application of some technologies due to this surface bioincompatibility. In this study we focused on the covalent attachment of zwitterionic phosphorylcholine (PC) or sulfobetaine (SB) moieties onto a TiAl(6)V(4) surface with a single step modification method to obtain a stable blood compatible interface. Silanated PC or SB modifiers (PCSi or SBSi) which contain an alkoxy silane group and either PC or SB groups were prepared respectively from trimethoxysilane and 2-methacryloyloxyethyl phosphorylcholine (MPC) or N-(3-sulfopropyl)-N-(methacryloxyethyl)-N,N-dimethylammonium betaine (SMDAB) monomers by a hydrosilylation reaction. A cleaned and oxidized TiAl(6)V(4) surface was then modified with the PCSi or SBSi modifiers by a simple surface silanization reaction. The surface was assessed with X-ray photoelectron spectroscopy (XPS), attenuated total reflection-Fourier transform infrared spectroscopy (ATR-FTIR) and contact angle goniometry. Platelet deposition and bulk phase activation were evaluated following contact with anticoagulated ovine blood. XPS results verified successful modification of the PCSi or SBSi modifiers onto TiAl(6)V(4) based on increases in surface phosphorous or sulfur respectively. Surface contact angles in water decreased with the addition of hydrophilic PC or SB moieties. Both the PCSi and SBSi modified TiAl(6)V(4) surfaces showed decreased platelet deposition and bulk phase platelet activation compared to unmodified TiAl(6)V(4) and control surfaces. This single step modification with PCSi or SBSi modifiers offers promise for improving the surface hemocompatibility of TiAl(6)V(4) and is attractive for its ease of application to geometrically complex metallic blood contacting devices.


Langmuir | 2013

Surface Modification of a Biodegradable Magnesium Alloy with Phosphorylcholine (PC) and Sulfobetaine (SB) Functional Macromolecules for Reduced Thrombogenicity and Acute Corrosion Resistance

Sang Ho Ye; Yong Seok Jang; Yeoheung Yun; Venkat Shankarraman; Joshua R. Woolley; Yi Hong; Lara J. Gamble; Kazuhiko Ishihara; William R. Wagner

Siloxane functionalized phosphorylcholine (PC) or sulfobetaine (SB) macromolecules (PCSSi or SBSSi) were synthesized to act as surface modifying agents for degradable metallic surfaces to improve acute blood compatibility and slow initial corrosion rates. The macromolecules were synthesized using a thiol-ene radical photopolymerization technique and then utilized to modify magnesium (Mg) alloy (AZ31) surfaces via an anhydrous phase deposition of the silane functional groups. X-ray photoelectron spectroscopy surface analysis results indicated successful surface modification based on increased nitrogen and phosphorus or sulfur composition on the modified surfaces relative to unmodified AZ31. In vitro acute thrombogenicity assessment after ovine blood contact with the PCSSi and SBSSi modified surfaces showed a significant decrease in platelet deposition and bulk phase platelet activation compared with the control alloy surfaces. Potentiodynamic polarization and electrochemical impedance spectroscopy data obtained from electrochemical corrosion testing demonstrated increased corrosion resistance for PCSSi- and SBSSi-modified AZ31 versus unmodified surfaces. The developed coating technique using PCSSi or SBSSi showed promise in acutely reducing both the corrosion and thrombotic processes, which would be attractive for application to blood contacting devices, such as vascular stents, made from degradable Mg alloys.


Journal of Biomedical Materials Research Part A | 2009

Covalent surface modification of a titanium alloy with a phosphorylcholine-containing copolymer for reduced thrombogenicity in cardiovascular devices.

Sang Ho Ye; Carl A. Johnson; Joshua R. Woolley; Trevor A. Snyder; Lara J. Gamble; William R. Wagner

Our objective was to develop a surface modification strategy for a titanium alloy (TiAl6V4) to provide thromboresistance for surfaces in rigorous blood-contacting cardiovascular applications, such as that found in ventricular assist devices. We hypothesized that this could be accomplished by the covalent attachment of a phospholipid polymer, poly(2-methacryloyloxyethylphosphorylcholine (MPC)-co-methacryl acid) (PMA). TiAl6V4 was H2O plasma treated by radio frequency glow discharge, silanated with 3-aminopropyltriethoxysilane (APS), and ammonia plasma treated to increase surface reactivity. The TiAl6V4 surface was then modified with PMA via a condensation reaction between the amino groups on the TiAl6V4 surface and the carboxyl groups on PMA. The surface composition was verified by X-ray photoelectron spectroscopy, confirming successful modification of the TiAl6V4 surfaces with APS and PMA as evidenced by increased Si and P. Plasma treatments with H2O and ammonia were effective at further increasing the surface reactivity of TiAl6V4 as evidenced by increased surface PMA. The adsorption of ovine fibrinogen onto PMA-modified surfaces was reduced relative to unmodified surfaces, and in vitro ovine blood contact through a rocking test revealed marked reductions in platelet deposition and bulk phase platelet activation relative to unmodified TiAl6V4 and polystyrene controls. The results indicate that the PMA-modification scheme for TiAl6V4 surfaces offers a potential pathway to improve the thromboresistance of the blood-contacting surfaces of cardiovascular devices.


Colloids and Surfaces B: Biointerfaces | 2009

Surface modification of a titanium alloy with a phospholipid polymer prepared by a plasma-induced grafting technique to improve surface thromboresistance

Sang Ho Ye; Carl A. Johnson; Joshua R. Woolley; Heung Il Oh; Lara J. Gamble; Kazuhiko Ishihara; William R. Wagner

To improve the thromboresistance of a titanium alloy (TiAl(6)V(4)) surface which is currently utilized in several ventricular assist devices (VADs), a plasma-induced graft polymerization of 2-methacryloyloxyethyl phosphorylcholine (MPC) was carried out and poly(MPC) (PMPC) chains were covalently attached onto a TiAl(6)V(4) surface by a plasma induced technique. Cleaned TiAl(6)V(4) surfaces were pretreated with H(2)O-vapor-plasma and silanated with 3-methacryloylpropyltrimethoxysilane (MPS). Next, a plasma-induced graft polymerization with MPC was performed after the surfaces were pretreated with Ar plasma. Surface compositions were verified by X-ray photoelectron spectroscopy (XPS). In vitro blood biocompatibility was evaluated by contacting the modified surfaces with ovine blood under continuous mixing. Bulk phase platelet activation was quantified by flow cytometric analysis, and surfaces were observed with scanning electron microscopy after blood contact. XPS data demonstrated successful modification of the TiAl(6)V(4) surfaces with PMPC as evidenced by increased N and P on modified surfaces. Platelet deposition was markedly reduced on the PMPC grafted surfaces and platelet activation in blood that contacted the PMPC-grafted samples was significantly reduced relative to the unmodified TiAl(6)V(4) and polystyrene control surfaces. Durability studies under continuously mixed water suggested no change in surface modification over a 1-month period. This modification strategy shows promise for further investigation as a means to reduce the thromboembolic risk associated with the metallic blood-contacting surfaces of VADs and other cardiovascular devices under development.


Artificial Organs | 2011

Biocompatibility Assessment of the First Generation PediaFlow Pediatric Ventricular Assist Device

Carl A. Johnson; Stijn Vandenberghe; Amanda R. Daly; Joshua R. Woolley; Shaun T. Snyder; Josiah E. Verkaik; Sang-Ho Ye; Harvey S. Borovetz; James F. Antaki; Peter D. Wearden; Marina V. Kameneva; William R. Wagner

The PediaFlow pediatric ventricular assist device is a miniature magnetically levitated mixed flow pump under development for circulatory support of newborns and infants (3-15 kg) with a targeted flow range of 0.3-1.5 L/min. The first generation design of the PediaFlow (PF1) was manufactured with a weight of approximately 100 g, priming volume less than 2 mL, length of 51 mm, outer diameter of 28 mm, and with 5-mm blood ports. PF1 was evaluated in an in vitro flow loop for 6 h and implanted in ovines for three chronic experiments of 6, 17, and 10 days. In the in vitro test, normalized index of hemolysis was 0.0087 ± 0.0024 g/100L. Hemodynamic performance and blood biocompatibility of PF1 were characterized in vivo by measurements of plasma free hemoglobin, plasma fibrinogen, total plasma protein, and with novel flow cytometric assays to quantify circulating activated ovine platelets. The mean plasma free hemoglobin values for the three chronic studies were 4.6 ± 2.7, 13.3 ± 7.9, and 8.8 ± 3.3 mg/dL, respectively. Platelet activation was low for portions of several studies but consistently rose along with observed animal and pump complications. The PF1 prototype generated promising results in terms of low hemolysis and platelet activation in the absence of complications. Hemodynamic results validated the magnetic bearing design and provided the platform for design iterations to meet the objective of providing circulatory support for young children with exceptional biocompatibility.


Artificial Organs | 2010

Hemocompatibility Assessment of Carbonic Anhydrase Modified Hollow Fiber Membranes for Artificial Lungs

Heung-Il Oh; Sang-Ho Ye; Carl A. Johnson; Joshua R. Woolley; William J. Federspiel; William R. Wagner

Hollow fiber membrane (HFM)-based artificial lungs can require a large blood-contacting membrane surface area to provide adequate gas exchange. However, such a large surface area presents significant challenges to hemocompatibility. One method to improve carbon dioxide (CO(2)) transfer efficiency might be to immobilize carbonic anhydrase (CA) onto the surface of conventional HFMs. By catalyzing the dehydration of bicarbonate in blood, CA has been shown to facilitate diffusion of CO(2) toward the fiber membranes. This study evaluated the impact of surface modifying a commercially available microporous HFM-based artificial lung on fiber blood biocompatibility. A commercial poly(propylene) Celgard HFM surface was coated with a siloxane, grafted with amine groups, and then attached with CA which has been shown to facilitate diffusion of CO(2) toward the fiber membranes. Results following acute ovine blood contact indicated no significant reduction in platelet deposition or activation with the siloxane coating or the siloxane coating with grafted amines relative to base HFMs. However, HFMs with attached CA showed a significant reduction in both platelet deposition and activation compared with all other fiber types. These findings, along with the improved CO(2) transfer observed in CA modified fibers, suggest that its incorporation into HFM design may potentiate the design of a smaller, more biocompatible HFM-based artificial lung.


Artificial Organs | 2011

Platelet activation in ovines undergoing sham surgery or implant of the second generation PediaFlow pediatric ventricular assist device.

Carl A. Johnson; Peter D. Wearden; Ergin Kocyildirim; Timothy M. Maul; Joshua R. Woolley; Sang-Ho Ye; Elise M. Strickler; Harvey S. Borovetz; William R. Wagner

The PediaFlow pediatric ventricular assist device (VAD) is a magnetically levitated turbodynamic pump under development for circulatory support of small children with a targeted flow rate range of 0.3-1.5 L/min. As the design of this device is refined, ensuring high levels of blood biocompatibility is essential. In this study, we characterized platelet activation during the implantation and operation of a second generation prototype of the PediaFlow VAD (PF2) and also performed a series of surgical sham studies to examine purely surgical effects on platelet activation. In addition, a newly available monoclonal antibody was characterized and shown to be capable of quantifying ovine platelet activation. The PF2 was implanted in three chronic ovine experiments of 17, 30, and 70 days, while surgical sham procedures were performed in five ovines with 30-day monitoring. Blood biocompatibility in terms of circulating activated platelets was measured by flow cytometric assays with and without exogenous agonist stimulation. Platelet activation following sham surgery returned to baseline in approximately 2 weeks. Platelets in PF2-implanted ovines returned to baseline activation levels in all three animals and showed an ability to respond to agonist stimulation. Late-term platelet activation was observed in one animal corresponding with unexpected pump stoppages related to a manufacturing defect in the percutaneous cable. The results demonstrated encouraging platelet biocompatibility for the PF2 in that basal platelet activation was achieved early in the pump implant period. Furthermore, this first characterization of the effect of a major cardiothoracic procedure on temporal ovine platelet activation provides comparative data for future cardiovascular device evaluation in the ovine model.


Cell Transplantation | 2006

Towards the development of a pediatric ventricular assist device.

Harvey S. Borovetz; Stephen F. Badylak; J. Robert Boston; Carl N. Johnson; Robert L. Kormos; Marina V. Kameneva; Marwan A. Simaan; Trevor A. Snyder; Hiro Tsukui; William R. Wagner; Joshua R. Woolley; James F. Antaki; Chenguang Diao; Stijn Vandenberghe; Bradley B. Keller; Victor Morell; Peter D. Wearden; Steven Webber; Jeff Gardiner; Chung M. Li; Dave Paden; Bradley E. Paden; Shaun T. Snyder; Jingchun Wu; Gill B. Bearnson; John A. Hawkins; Jacobs G; John Kirk; Pratap S. Khanwilkar; Peter C. Kouretas

The very limited options available to treat ventricular failure in children with congenital and acquired heart diseases have motivated the development of a pediatric ventricular assist device at the University of Pittsburgh (UoP) and University of Pittsburgh Medical Center (UPMC). Our effort involves a consortium consisting of UoP, Childrens Hospital of Pittsburgh (CHP), Carnegie Mellon University, World Heart Corporation, and LaunchPoint Technologies, Inc. The overall aim of our program is to develop a highly reliable, biocompatible ventricular assist device (VAD) for chronic support (6 months) of the unique and high-risk population of children between 3 and 15 kg (patients from birth to 2 years of age). The innovative pediatric ventricular assist device we are developing is based on a miniature mixed flow turbodynamic pump featuring magnetic levitation, to assure minimal blood trauma and risk of thrombosis. This review article discusses the limitations of current pediatric cardiac assist treatment options and the work to date by our consortium toward the development of a pediatric VAD.


Artificial Organs | 2014

Temporal Leukocyte Numbers and Granulocyte Activation in Pulsatile and Rotary Ventricular Assist Device Patients

Joshua R. Woolley; Jeffrey J. Teuteberg; C. Bermudez; J.K. Bhama; Kathleen Lockard; Robert L. Kormos; William R. Wagner

Individual ventricular assist device (VAD) design may affect leukocytes and impact immunity. Few studies have presented leukocyte and infection profiles in VAD patients over the course of the implant period. CD11b (MAC-1) expression on granulocytes is an indicator of activation during inflammation, mediating extravasation and the release of reactive oxygen species in tissue. No reported studies have presented MAC-1 expression on circulating granulocytes in VAD patients. Fifty-six patients implanted at a single center with a HeartMate II (HMII; n = 32), HeartWare (HW; n = 12), or Thoratec pneumatic VAD (PVAD; n = 12) between 1999 and 2011 were followed for 120 days of support. The leukocyte profiles and infectious events of all patients were evaluated; additionally, a subset had MAC-1 expression on circulating granulocytes was measured (HMII n = 9; HW n = 7; PVAD n = 4). All groups exhibited a significant peak in leukocyte numbers at postoperative day (POD) 14 while simultaneously experiencing a significant decrease in hematocrit. HMII patients exhibited a 3.2-fold increase in granulocyte MAC-1 expression at POD 14, and the temporal trend over the implant period differed from that experienced by HW patients. Further, HW patients experienced significantly fewer infection events. Alterations in leukocyte profiles and granulocyte activation experienced by VAD patients appear to be device-specific. Elevations in leukocyte activation may be related to an increased risk for infection, although the specific relationship between these phenomena in this patient group is not known.


Journal of Biomedical Materials Research Part A | 2015

Real time visualization and characterization of platelet deposition under flow onto clinically relevant opaque surfaces

Megan A. Jamiolkowski; Joshua R. Woolley; Marina V. Kameneva; James F. Antaki; William R. Wagner

Although the thrombogenic nature of the surfaces of cardiovascular devices is an important aspect of blood biocompatibility, few studies have examined platelet deposition onto opaque materials used for these devices in real time. This is particularly true for the metallic surfaces used in current ventricular assist devices (VADs). Using hemoglobin depleted red blood cells (RBC ghosts) and long working distance optics to visualize platelet deposition, we sought to perform such an evaluation. Fluorescently labeled platelets mixed with human RBC ghosts were perfused across six opaque materials (a titanium alloy (Ti6Al4V), silicon carbide (SiC), alumina (Al2O3, 2-methacryloyloxyethyl phosphorylcholine polymer coated Ti6Al4V (MPC-Ti6Al4V), yttria partially stabilized zirconia (YZTP), and zirconia toughened alumina (ZTA)) for 5 min at wall shear rates of 400 and 1000 s(-1). Ti6Al4V had significantly increased platelet deposition relative to MPC-Ti6Al4V, Al2 O3 , YZTP, and ZTA at both wall shear rates (p < 0.01). For all test surfaces, increasing the wall shear rate produced a trend of decreased platelet adhesion. The described system can be a utilized as a tool for comparative analysis of candidate blood-contacting materials with acute blood contact.

Collaboration


Dive into the Joshua R. Woolley's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Trevor A. Snyder

Integris Baptist Medical Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

James F. Antaki

Carnegie Mellon University

View shared research outputs
Top Co-Authors

Avatar

Lara J. Gamble

University of Washington

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Sang Ho Ye

University of Pittsburgh

View shared research outputs
Researchain Logo
Decentralizing Knowledge