Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Sang-Ho Ye is active.

Publication


Featured researches published by Sang-Ho Ye.


ACS Applied Materials & Interfaces | 2014

Nonthrombogenic, biodegradable elastomeric polyurethanes with variable sulfobetaine content.

Sang-Ho Ye; Yi Hong; Hirokazu Sakaguchi; Venkat Shankarraman; Samuel K. Luketich; Antonio D’Amore; William R. Wagner

For applications where degradable polymers are likely to have extended blood contact, it is often important for these materials to exhibit high levels of thromboresistance. This can be achieved with surface modification approaches, but such modifications may be transient with degradation. Alternatively, polymer design can be altered such that the bulk polymer is thromboresistant and this is maintained with degradation. Toward this end a series of biodegradable, elastic polyurethanes (PESBUUs) containing different zwitterionic sulfobetaine (SB) content were synthesized from a polycaprolactone-diol (PCL-diol):SB-diol mixture (100:0, 75:25, 50:50, 25:75 and 0:100) reacted with diisocyanatobutane and chain extended with putrescine. The chemical structure, tensile mechanical properties, thermal properties, hydrophilicity, biodegradability, fibrinogen adsorption and thrombogenicity of the resulting polymers was characterized. With increased SB content some weakening in tensile properties occurred in wet conditions and enzymatic degradation also decreased. However, at higher zwitterionic molar ratios (50% and 75%) wet tensile strength exceeded 15 MPa and breaking strain was >500%. Markedly reduced thrombotic deposition was observed both before and after substantial degradation for both of these PESBUUs and they could be processed by electrospinning into a vascular conduit format with appropriate compliance properties. The mechanical and degradation properties as well as the acute in vitro thrombogenicity assessment suggest that these tunable polyurethanes could provide options appropriate for use in blood contacting applications where a degradable, elastomeric component with enduring thromboresistance is desired.


Acta Biomaterialia | 2014

Biodegradable Poly(ester urethane)urea Elastomers with Variable Amino Content for Subsequent Functionalization with Phosphorylcholine

Jun Fang; Sang-Ho Ye; Venkat Shankarraman; Yixian Huang; Xiumei Mo; William R. Wagner

While surface modification is well suited for imparting biomaterials with specific functionality for favorable cell interactions, the modification of degradable polymers would be expected to provide only temporary benefit. Bulk modification by incorporating pendant reactive groups for subsequent functionalization of biodegradable polymers would provide a more enduring approach. Towards this end, a series of biodegradable poly(ester urethane)urea elastomers with variable amino content (PEUU-NH2 polymers) were developed. Carboxylated phosphorycholine was synthesized and conjugated to the PEUU-NH2 polymers for subsequent bulk functionalization to generate PEUU-PC polymers. Synthesis was verified by proton nuclear magnetic resonance, X-ray photoelectron spectroscopy and attenuated total reflection Fourier transform infrared spectroscopy. The impact of amine incorporation and phosphorylcholine conjugation was shown on mechanical, thermal and degradation properties. Water absorption increased with increasing amine content, and further with PC conjugation. In wet conditions, tensile strength and initial modulus generally decreased with increasing hydrophilicity, but remained in the range of 5-30 MPa and 10-20 MPa, respectively. PC conjugation was associated with significantly reduced platelet adhesion in blood contact testing and the inhibition of rat vascular smooth muscle cell proliferation. These biodegradable PEUU-PC elastomers offer attractive properties for applications as non-thrombogenic, biodegradable coatings and for blood-contacting scaffold applications. Further, the PEUU-NH2 base polymers offer the potential to have multiple types of biofunctional groups conjugated onto the backbone to address a variety of design objectives.


Artificial Organs | 2011

Biocompatibility Assessment of the First Generation PediaFlow Pediatric Ventricular Assist Device

Carl A. Johnson; Stijn Vandenberghe; Amanda R. Daly; Joshua R. Woolley; Shaun T. Snyder; Josiah E. Verkaik; Sang-Ho Ye; Harvey S. Borovetz; James F. Antaki; Peter D. Wearden; Marina V. Kameneva; William R. Wagner

The PediaFlow pediatric ventricular assist device is a miniature magnetically levitated mixed flow pump under development for circulatory support of newborns and infants (3-15 kg) with a targeted flow range of 0.3-1.5 L/min. The first generation design of the PediaFlow (PF1) was manufactured with a weight of approximately 100 g, priming volume less than 2 mL, length of 51 mm, outer diameter of 28 mm, and with 5-mm blood ports. PF1 was evaluated in an in vitro flow loop for 6 h and implanted in ovines for three chronic experiments of 6, 17, and 10 days. In the in vitro test, normalized index of hemolysis was 0.0087 ± 0.0024 g/100L. Hemodynamic performance and blood biocompatibility of PF1 were characterized in vivo by measurements of plasma free hemoglobin, plasma fibrinogen, total plasma protein, and with novel flow cytometric assays to quantify circulating activated ovine platelets. The mean plasma free hemoglobin values for the three chronic studies were 4.6 ± 2.7, 13.3 ± 7.9, and 8.8 ± 3.3 mg/dL, respectively. Platelet activation was low for portions of several studies but consistently rose along with observed animal and pump complications. The PF1 prototype generated promising results in terms of low hemolysis and platelet activation in the absence of complications. Hemodynamic results validated the magnetic bearing design and provided the platform for design iterations to meet the objective of providing circulatory support for young children with exceptional biocompatibility.


Biomacromolecules | 2015

Thiol Click Modification of Cyclic Disulfide Containing Biodegradable Polyurethane Urea Elastomers

Jun Fang; Sang-Ho Ye; Jing Wang; Ting Zhao; Xiumei Mo; William R. Wagner

Although the thiol click reaction is an attractive tool for postpolymerization modification of thiolmers, thiol groups are easily oxidized, limiting the potential for covalent immobilization of bioactive molecules. In this study, a series of biodegradable polyurethane elastomers incorporating stable cyclic disulfide groups was developed and characterized. These poly(ester urethane)urea (PEUU-SS) polymers were based on polycaprolactone diol (PCL), oxidized dl-dithiothreitol (O-DTT), lysine diisocyanate (LDI), or butyl diisocyanate (BDI), with chain extension by putrescine. The ratio of O-DTT:PCL was altered to investigate different levels of potential functionalization. PEG acrylate was employed to study the mechanism and availability of both bulk and surface click modification of PEUU-SS polymers. All synthesized PEUU-SS polymers were elastic with breaking strengths of 38-45 MPa, while the PEUU-SS(LDI) polymers were more amorphous, possessing lower moduli and relatively small permanent deformations versus PEUU-SS(BDI) polymers. Variable bulk click modification of PEUU-SS(LDI) polymers was achieved by controlling the amount of reduction reagent, and rapid reaction rates occurred using a one-pot, two-step process. Likewise, surface click reaction could be carried out quickly under mild, aqueous conditions. Furthermore, a maleimide-modified affinity peptide (TPS) was successfully clicked on the surface of an electrospun PEUU-SS(BDI) fibrous sheet, which improved endothelial progenitor cell adhesion versus corresponding unmodified films. The cyclic disulfide containing biodegradable polyurethanes described provide an option for cardiovascular and other soft tissue regenerative medicine applications where a temporary, elastic scaffold with designed biofunctionality from a relatively simple click chemistry approach is desired.


Artificial Organs | 2010

Hemocompatibility Assessment of Carbonic Anhydrase Modified Hollow Fiber Membranes for Artificial Lungs

Heung-Il Oh; Sang-Ho Ye; Carl A. Johnson; Joshua R. Woolley; William J. Federspiel; William R. Wagner

Hollow fiber membrane (HFM)-based artificial lungs can require a large blood-contacting membrane surface area to provide adequate gas exchange. However, such a large surface area presents significant challenges to hemocompatibility. One method to improve carbon dioxide (CO(2)) transfer efficiency might be to immobilize carbonic anhydrase (CA) onto the surface of conventional HFMs. By catalyzing the dehydration of bicarbonate in blood, CA has been shown to facilitate diffusion of CO(2) toward the fiber membranes. This study evaluated the impact of surface modifying a commercially available microporous HFM-based artificial lung on fiber blood biocompatibility. A commercial poly(propylene) Celgard HFM surface was coated with a siloxane, grafted with amine groups, and then attached with CA which has been shown to facilitate diffusion of CO(2) toward the fiber membranes. Results following acute ovine blood contact indicated no significant reduction in platelet deposition or activation with the siloxane coating or the siloxane coating with grafted amines relative to base HFMs. However, HFMs with attached CA showed a significant reduction in both platelet deposition and activation compared with all other fiber types. These findings, along with the improved CO(2) transfer observed in CA modified fibers, suggest that its incorporation into HFM design may potentiate the design of a smaller, more biocompatible HFM-based artificial lung.


Colloids and Surfaces B: Biointerfaces | 2016

Biodegradable, elastomeric coatings with controlled anti-proliferative agent release for magnesium-based cardiovascular stents.

Xinzhu Gu; Zhongwei Mao; Sang-Ho Ye; Youngmi Koo; Yeoheung Yun; Tarannum Tiasha; Vesselin Shanov; William R. Wagner

Vascular stent design continues to evolve to further improve the efficacy and minimize the risks associated with these devices. Drug-eluting coatings have been widely adopted and, more recently, biodegradable stents have been the focus of extensive evaluation. In this report, biodegradable elastomeric polyurethanes were synthesized and applied as drug-eluting coatings for a relatively new class of degradable vascular stents based on Mg. The dynamic degradation behavior, hemocompatibility and drug release were investigated for poly(carbonate urethane) urea (PCUU) and poly(ester urethane) urea (PEUU) coated magnesium alloy (AZ31) stents. Poly(lactic-co-glycolic acid) (PLGA) coated and bare stents were employed as control groups. The PCUU coating effectively slowed the Mg alloy corrosion in dynamic degradation testing compared to PEUU-coated, PLGA-coated and bare Mg alloy stents. This was confirmed by electron microscopy, energy-dispersive x-ray spectroscopy and magnesium ion release experiments. PCUU-coating of AZ31 was also associated with significantly reduced platelet adhesion in acute blood contact testing. Rat vascular smooth muscle cell (rSMC) proliferation was successfully inhibited when paclitaxel was released from pre-loaded PCUU coatings. The corrosion retardation, low thrombogenicity, drug loading capacity, and high elasticity make PCUU an attractive option for drug eluting coating on biodegradable metallic cardiovascular stents.


Artificial Organs | 2011

Platelet activation in ovines undergoing sham surgery or implant of the second generation PediaFlow pediatric ventricular assist device.

Carl A. Johnson; Peter D. Wearden; Ergin Kocyildirim; Timothy M. Maul; Joshua R. Woolley; Sang-Ho Ye; Elise M. Strickler; Harvey S. Borovetz; William R. Wagner

The PediaFlow pediatric ventricular assist device (VAD) is a magnetically levitated turbodynamic pump under development for circulatory support of small children with a targeted flow rate range of 0.3-1.5 L/min. As the design of this device is refined, ensuring high levels of blood biocompatibility is essential. In this study, we characterized platelet activation during the implantation and operation of a second generation prototype of the PediaFlow VAD (PF2) and also performed a series of surgical sham studies to examine purely surgical effects on platelet activation. In addition, a newly available monoclonal antibody was characterized and shown to be capable of quantifying ovine platelet activation. The PF2 was implanted in three chronic ovine experiments of 17, 30, and 70 days, while surgical sham procedures were performed in five ovines with 30-day monitoring. Blood biocompatibility in terms of circulating activated platelets was measured by flow cytometric assays with and without exogenous agonist stimulation. Platelet activation following sham surgery returned to baseline in approximately 2 weeks. Platelets in PF2-implanted ovines returned to baseline activation levels in all three animals and showed an ability to respond to agonist stimulation. Late-term platelet activation was observed in one animal corresponding with unexpected pump stoppages related to a manufacturing defect in the percutaneous cable. The results demonstrated encouraging platelet biocompatibility for the PF2 in that basal platelet activation was achieved early in the pump implant period. Furthermore, this first characterization of the effect of a major cardiothoracic procedure on temporal ovine platelet activation provides comparative data for future cardiovascular device evaluation in the ovine model.


ACS Applied Materials & Interfaces | 2016

Orthogonally Functionalizable Polyurethane with Subsequent Modification with Heparin and Endothelium-Inducing Peptide Aiming for Vascular Reconstruction

Jun Fang; Jialing Zhang; Jun Du; Yanjun Pan; Jing Shi; Yongxuan Peng; Weiming Chen; Liu Yuan; Sang-Ho Ye; William R. Wagner; Meng Yin; Xiumei Mo

Surface coimmobilization modifications of blood-contacting devices with both antithrombogenic moieties and endothelium-inducing biomolecules may create a synergistic effect to improve their performance. However, it is difficult to perform covalent dual-functionalization with both biomolecules on the surface of normally used synthetic polymeric substrates. Herein, we developed and characterized an orthogonally functionalizable polymer, biodegradable elastic poly(ester urethane)urea with disulfide and amino groups (PUSN), which was further fabricated into electropun fibrous scaffolds and surface modified with heparin and endothelial progenitor cells (EPC) recruiting peptide (TPS). The modification effects were assessed through platelet adhesion, EPC, and HUVEC proliferation. Results showed the dual modified PUSN scaffolds demonstrated a synergistic effect of reduced platelet deposition and improved EPC proliferation in vitro study, and demonstrated their potential application in small diameter vascular regeneration.


PLOS ONE | 2018

Comparison of endothelial cell attachment on surfaces of biodegradable polymer-coated magnesium alloys in a microfluidic environment

Lumei Liu; Sang-Ho Ye; Xinzhu Gu; Teal Russell; Zhigang Xu; Jagannathan Sankar; William R. Wagner; Young-Choon Lee; Yeoheung Yun

Polymeric coatings can provide temporary stability to bioresorbable metallic stents at the initial stage of deployment by alleviating rapid degradation and providing better interaction with surrounding vasculature. To understand this interfacing biocompatibility, this study explored the endothelial-cytocompatibility of polymer-coated magnesium (Mg) alloys under static and dynamic conditions compared to that of non-coated Mg alloy surfaces. Poly (carbonate urethane) urea (PCUU) and poly (lactic-co-glycolic acid) (PLGA) were coated on Mg alloys (WE43, AZ31, ZWEKL, ZWEKC) and 316L stainless steel (316L SS, control sample), which were embedded into a microfluidic device to simulate a vascular environment with dynamic flow. The results from attachment and viability tests showed that more cells were attached on the polymer-coated Mg alloys than on non-coated Mg alloys in both static and dynamic conditions. In particular, the attachment and viability on PCUU-coated surfaces were significantly higher than that of PLGA-coated surfaces of WE43 and ZWEKC in both static and dynamic conditions, and of AZ31 in dynamic conditions (P<0.05). The elementary distribution map showed that there were relatively higher Carbon weight percentages and lower Mg weight percentages on PCUU-coated alloys than PLGA-coated alloys. Various levels of pittings were observed underneath the polymer coatings, and the pittings were more severe on the surface of Mg alloys that corroded rapidly. Polymer coatings are recommended to be applied on Mg alloys with relatively low corrosion rates, or after pre-stabilizing the substrate. PCUU-coating has more selective potential to enhance the biocompatibility and mitigate the endothelium damage of Mg alloy stenting.


Langmuir | 2018

Biodegradable Zwitterionic Polymer Coatings for Magnesium Alloy Stents

Sang-Ho Ye; Yingqi Chen; Zhongwei Mao; Xinzhu Gu; Venkat Shankarraman; Yi Hong; Vesselin Shanov; William R. Wagner

Degradable metallic stents, most commonly composed of Mg-based alloys, are of interest as an alternative to traditional metallic stents for application in cardiac and peripheral vasculature. Two major design challenges with such stents are control of the corrosion rate and acute presentation of a nonthrombogenic surface to passing blood. In this study, several types of sulfobetaine (SB)-bearing biodegradable polyurethanes were developed and assessed as physical, chemical, and combination-type coatings for a model degradable Mg alloy, AZ31. For physical coatings, poly(ester sulfobetaine)urethane ureas, PESBUUs were synthesized using variable monomers that allowed the incorporation of a varying extent of carboxyl groups. Introduction of the carboxyl groups was associated with faster polymer degradation time. Simple physical coating of PESBUUs reduced macro- and microscopic thrombogenic deposition together with good stability of the coating attachment compared to a control coating of polylactic- co-glycolic acid. For PESBUUs incorporating carboxyl groups (PESBUUs-COOH), these groups could be converted to siloxane groups (PESBUUs-Si), thus creating polymers that could be surface reacted with the oxidized or phytic acid treated AZ31 surface. Chemical (silanization) attachment of these polymers reduced underlying alloy corrosion rates, but following the salination reaction with physical coating most reduced corrosion rates and protected the surface better from the consequences of oxidation occurring under the coating, such as blistering. The application of a multilayered coating approach using a sulfobetaine-based biodegradable elastomer thus offers options for degradable metallic stent design where thromboresistance is desired in combination with a means to control both polymeric coating degradation rates and underlying alloy corrosion rates.

Collaboration


Dive into the Sang-Ho Ye's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Xinzhu Gu

University of Pittsburgh

View shared research outputs
Top Co-Authors

Avatar

Yang Zhu

University of Pittsburgh

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Vesselin Shanov

Applied Science Private University

View shared research outputs
Researchain Logo
Decentralizing Knowledge