Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Joyce Low is active.

Publication


Featured researches published by Joyce Low.


Blood Coagulation & Fibrinolysis | 2004

Factor V inhibitors: rare or not so uncommon? A multi-laboratory investigation

Emmanuel J. Favaloro; Jennifer Posen; Raj Ramakrishna; Soma Soltani; Simon Mcrae; Sarah Just; Margaret Aboud; Joyce Low; Rosalie Gemmell; Geoff Kershaw; Robyn Coleman; Mark Dean

Acquired deficiencies of, or inhibitors to, factor V are considered rare events. We report a series of 14 acquired factor V deficiencies, 10 of which were confirmed to have inhibitors to factor V, as identified within Australia in the past 5 years following a multi-laboratory investigation. The initial index case seen by one laboratory was followed within 4 months by a separate similar case. This prompted local contact with colleagues (n = 20) working in other haemostasis referral laboratories to identify the current case series. In total, nearly one-half of all haemostasis referral laboratories contacted had seen a case within the past 5 years. Clinical features and the apparent associated risk of bleeding complications generally varied, as did laboratory findings and the likely causal event. There were three females and 11 males. Age ranged from 44 to 95 years (median, 81 years). The level of inhibitor ranged from undetectable to over 250 Bethesda units. The probable cause leading to development of the inhibitors ranged from exposure to bovine thrombin, exposure to antibiotics, surgery and malignancy. Of additional interest was the apparent association of anti-phospholipid antibodies in many of the cases. For example, in the two similar index cases, with factor V inhibitor titres > 200 Bethesda units, high levels of anti-cardiolipin antibodies (> 70 GPL units) were also detected. Although less clear because of inhibitor interference, many of the cases also showed evident co-associated lupus anticoagulant activity. In conclusion, we report a series of factor V inhibitors recently identified within our geographic region that would represent an annual incidence of around 0.29 cases per million Australians. Although considered a rare finding, there is a high likelihood that most haemostasis referral laboratories will see a case every five or so years.


British Journal of Haematology | 2008

Timely diagnosis and management of heparin-induced thrombocytopenia in a frequent request, low incidence single centre using clinical 4T's score and particle gel immunoassay

Adam Bryant; Joyce Low; Steven Austin; Joanne E. Joseph

Clinicians must promptly decide which patients suspected of having heparin‐induced thrombocytopenia (HIT) warrant a change in anticoagulation. This single‐centre series of 246 HIT testing referrals assessed the combination of clinical score (thrombocytopenia, timing, thrombosis, other causes of thrombocytopenia not evident; 4T’s), Diamed ID‐Heparin‐PF4 immunoassay (PaGIA) and 14C Serotonin Release Assay (SRA) to develop a practical and safe diagnostic strategy for HIT. A total of 142/256 (58%) referrals were in patients with a low 4T’s score, with 12/246 (5%) in the high scoring group. PaGIA was positive in 24/246 (9·7%) patients, whilst SRA was positive in 9/246 (3·6%). The overall positive predictive value of a positive PaGIA test alone was 37·5%, however this reached 80% for the high scoring group. Both negative PaGIA and low clinical score independently had negative predictive values of 100%. We subsequently developed an algorithm that, when applied to this cohort, would have resulted in 18/246 patients (7%) definitely requiring alternative anticoagulation, whilst a further 7/246 (2·8%) patients would have been considered on an individual basis. Ultimately (based on SRA) this would have resulted in 16/246 (6·5%) patients unnecessarily having a change in their anticoagulation, with 9/246 (3·6%) patients being ‘correctly treated’. The combination of 4T’s scoring and PaGIA permitted a practical and safe approach to rapid HIT diagnosis and management.


Genesis | 2010

Generation and characterization of mice with null mutation of the chloride intracellular channel 1 gene.

Min Ru Qiu; Lele Jiang; Klaus I. Matthaei; Simone M. Schoenwaelder; Tamara Kuffner; Pierre Mangin; Joanne E. Joseph; Joyce Low; David E. Connor; Stella M. Valenzuela; Paul M. G. Curmi; Louise J. Brown; Martyn P. Mahaut-Smith; Shaun P. Jackson; Samuel N. Breit

CLIC1 belongs to a family of highly conserved and widely expressed intracellular chloride ion channel proteins existing in both soluble and membrane integrated forms. To study the physiological and biological role of CLIC1 in vivo, we undertook conditional gene targeting to engineer Clic1 gene knock‐out mice. This represents creation of the first gene knock‐out of a vertebrate CLIC protein family member. We first generated a Clic1 Knock‐in (Clic1FN) allele, followed by Clic1 knock‐out (Clic1−/−) mice by crossing Clic1FN allele with TNAP‐cre mice, resulting in germline gene deletion through Cre‐mediated recombination. Mice heterozygous or homozygous for these alleles are viable and fertile and appear normal. However, Clic1−/− mice show a mild platelet dysfunction characterized by prolonged bleeding times and decreased platelet activation in response to adenosine diphosphate stimulation linked to P2Y12 receptor signaling. genesis 48:127–136, 2010.


Thrombosis and Haemostasis | 2006

Identification of factor inhibitors by diagnostic haemostasis laboratories. A large multi-centre evaluation

Emmanuel J. Favaloro; Roslyn Bonar; Elizabeth Duncan; Gail Earl; Joyce Low; Margaret Aboud; Sarah Just; John Sioufi; Alison Street; Ka Marsden

We have assessed the proficiency of diagnostic haemostasis facilities to correctly identify coagulation factor abnormalities and inhibitors. Forty-two laboratories participating in the external Quality Assurance Program (QAP) conducted by the RCPA agreed to participate and were each sent a set of eight samples (each 3 x 1 ml) for evaluation. They were asked to blind test these samples for the presence or absence of inhibitors, and where identified, to perform further analysis (including specific inhibitor analysis). In order to make the exercise more challenging, in addition to true factor inhibitors, samples were provided that reflected potential pre-analytical variables that might arise and complicate inhibitor detection or lead to false inhibitor identification. In brief, the sample set comprised a true high level factor (F) V inhibitor, a true moderate level FVIII inhibitor (but sample was defibrinogenated), a true lupus anticoagulant (LA), a normal (but slightly aged) plasma sample, a normal serum sample, a normal EDTA sample, an oral anticoagulant/vitamin K deficiency sample, and a gross heparin ( approximately 10 U/ml) contaminated sample. Sixty-three percent of participants correctly identified the true FV inhibitor as such, although the reported range varied greatly [10 to >250 Bethesda units (BU/ml)] and 46% correctly identified the true FVIII inhibitor, despite the complication of the sample presentation, although the reported range also varied (7 to 64 BU/ml). Some laboratories either failed to identify the inhibitor present, or misidentified the inhibitor type. The LA, the oral anticoagulant/vitamin K deficiency, the normal serum sample, and the normal (aged) sample were also correctly identified by most laboratories, as was the absence of specific factor inhibitors in these samples. However, a small subset of laboratories incorrectly identified the presence of specific factor inhibitors in some of these samples. The heparin sample was also correctly identified by most (68%) laboratories. In contrast, the normal EDTA sample was misidentified as a FV and/or FVIII inhibitor by most (68%) laboratories, and only one laboratory correctly identified this as an EDTA sample. Thus, we conclude that although laboratories are able, in most cases, to identify the presence of true factor inhibitors, there is a large variation in identified inhibitor levels and there are also some significant errors in identification (i.e. false negatives and misidentifications). In addition, there is a significant false positive error rate where some laboratories will identify the presence of specific factor inhibitors where no such inhibitor exists (i.e. false positives).


Thrombosis Research | 1980

Fibrinolytic activity of gastroduodenal secretions - a possible role in upper gastrointestinal haemorrhage

Joyce Low; Anthony J. Dodds; James C. Biggs

Abstract Fibrinolytic activity in the upper gastrointestinal tract may be a factor contributing towards the haemorrhage that often complicates gastroduodenal ulcers and erosions. In this report the fibrinolytic activity of the gastroduodenal secretions has been studied using a 125 I-labelled clot lysis technique. Fibrin was readily degraded by gastric juice and duodenal juice. Gastric juice was particularly potent and a haemostatic fibrin clot in the stomach must be regarded as a potential substrate for its action. Fibrinolytic inhibitors other than EACA and tranexamic acid have no effect on pepsin but inhibit the pancreatic enzymes to various extents. Serum inhibitors were the most active against pancreatic enzyme activity. The role that the gastroduodenal secretions may play in upper gastrointestinal haemorrhage is discussed and a mechanism involving cycles of clot lysis followed by clot formation, is put forward as a possible explanation for the intermittent nature of gastrointestinal bleeding.


European Journal of Vascular and Endovascular Surgery | 2009

In vitro Effects of Detergent Sclerosants on Antithrombotic Mechanisms

Kurosh Parsi; Thomas Exner; Joyce Low; D. Dang Fung Ma; Joanne E. Joseph

OBJECTIVES To investigate the in vitro effects of detergent sclerosants on antithrombotic pathways. MATERIALS AND METHODS Proteins C, S and antithrombin (AT) were assayed in normal plasma treated with increasing concentrations of sodium tetradecyl sulphate (STS) and polidocanol (POL). Activated protein C (APC) was investigated by mixing normal plasmas with sclerosants and testing with the activated partial thromboplastin time (APTT) and dilute Russells viper venom time in the presence and absence of APC. The effect on factor Xa (FXa), heparin and enoxaparin was investigated using chromogenic anti-FXa and APTT methods. RESULTS High concentration (>0.6%) STS significantly destroyed proteins C, S and AT whereas POL only caused a mild reduction in PC and AT and a moderate (60%) reduction in PS levels. STS potentiated the anticoagulant effect of APC while POL increased APC resistance. STS mimicked AT and demonstrated significant anti-Xa and anti-IIa activity. STS demonstrated a similar anticoagulant profile to heparin but was 1000x weaker. It also significantly potentiated the anticoagulant effect of heparin while POL had less effect. CONCLUSION STS and POL demonstrated quite distinct and sometimes opposite effects on the antithrombotic mechanisms assayed. These effects were concentration-dependent and in general, STS had the greatest effect on antithrombotic proteins.


British Journal of Haematology | 2005

A single-centre prospective study of clinical and haemostatic risk factors for venous thromboembolism following lower limb arthroplasty

Joanne E. Joseph; Joyce Low; Brett Courtenay; Michael J. Neil; Michael A. McGrath; David Ma

Previous studies report conflicting results concerning the potential significance of thrombophilic genotypes in postarthroplasty venous thromboembolism (VTE). This study assessed thrombophilic genotypes, haemostatic and clinical variables as independent risk factors for VTE postarthroplasty. A total number of 569 patients undergoing elective lower limb arthroplasty at a single centre were prospectively studied. All patients were interviewed and had blood samples collected preoperatively. Bilateral lower limb ultrasonography was performed at day 7 ± 2 postoperatively in all patients (ventilation/perfusion lung scanning in symptomatic patients only). The incidence of inhospital postoperative VTE was 26%. In univariate analysis – increased age, knee arthroplasty, recent surgery, general anaesthesia, shorter operation time, non‐receipt of blood transfusion and differences in surgical practice (including use of pneumatic calf compression, surgical drains and postoperative bandaging techniques) were significantly associated with VTE. Factor V Leiden, prothrombin G20210A and MTHFR C677T mutations were not significant risk factors for VTE, and of all haemostatic variables tested, only median activated partial thromboplastin time showed significant difference between VTE and non‐VTE patients (34 s vs. 33 s). Multiple logistic regression analysis demonstrated that increased age, knee arthroplasty and individual surgeons routine practices were the only significant independent risks for VTE; hence routine preoperative blood screening for a potential hypercoaguable state is not indicated in this surgical setting.


European Journal of Vascular and Endovascular Surgery | 2011

In Vitro Effects of Detergent Sclerosants on Clot Formation and Fibrinolysis

Kurosh Parsi; Thomas Exner; Joyce Low; D.D. Fung Ma; Joanne E. Joseph

OBJECTIVE To investigate the in vitro effects of detergent sclerosants sodium tetradecyl sulphate (STS) and polidocanol (POL) on clot formation and lysis. MATERIALS AND METHODS clot kinetics were assessed in whole blood by thromboelastography (TEG®) and rotational thromboelastometry (ROTEM®). Fibrinogen was measured by the Clauss method in plasma and factor XIII (FXIII) by enzyme-linked immunosorbent assay (ELISA). Turbidity measurements were used to assess clot lysis in plasma, and fibrinolysis in non-cross-linked and cross-linked fibrin. D-dimer was measured by VIDAS®, STA®Liatest® and AxSYM® assays. RESULTS Strong clots were formed at low sclerosant concentrations (0.075-0.1%). At midrange concentrations (0.15% STS, 0.15-0.3% POL), both agents inhibited the contribution of platelets to clot firmness and formed weak clots prone to lysis. At higher concentrations (STS ≥ 0.3% and POL ≥ 0.6%), clot formation was inhibited. STS destroyed FXIII at ≥ 0.15% and fibrinogen at ≥ 0.6%. Neither sclerosant had a significant effect on cross-linked fibrin, but STS had a lytic effect on non-cross-linked fibrin. STS caused an artefactual elevation of D-dimer in the VIDAS® assay when fibrinogen was present. CONCLUSION Detergent sclerosants demonstrated a trimodal effect on clot formation, initiating strong clots at low concentrations, weak clots at midrange concentrations and preventing clot formation at higher concentrations. Neither agent had fibrinolytic activity.


Journal of Heart and Lung Transplantation | 2016

Longitudinal changes in hemostatic parameters and reduced pulsatility contribute to non-surgical bleeding in patients with centrifugal continuous-flow left ventricular assist devices.

K. Muthiah; David E. Connor; Ken Ly; Elizabeth E. Gardiner; Robert K. Andrews; Jianlin Qiao; Darren Rutgers; D. Robson; Joyce Low; Susan Jarvis; Peter B MacDonald; K. Dhital; P. Jansz; Joanne E. Joseph; Christopher S. Hayward

BACKGROUND Bleeding and thromboembolic events are identified complications in patients supported with newer centrifugal continuous-flow left ventricular assist devices (cfLVADs). Bleeding events have been associated with acquired von Willebrand syndrome (vWS) in these patients, though longitudinal changes and the effect of pulsatility remain unquantified. We evaluated longitudinal effects of third-generation cfLVADs on hemostatic biomarkers, non-surgical bleeding, and thromboembolic events. We investigated the association between pulsatility (as defined by aortic valve opening) on von Willebrand Factor (VWF) profile and bleeding. METHODS We prospectively studied 28 patients implanted with the HeartWare (HeartWare International, Framingham, MA) cfLVAD for up to 360 days. We performed bleeding and coagulation assays 8 times from pre-implant to Day 360 (D360) post-implant, including platelet aggregometry, VWF collagen binding activity-to-antigen (CBA/Ag) ratio, thromboelastography, soluble P-selectin, platelet-specific marker soluble glycoprotein VI (sGPVI), and platelet microparticles. Aortic valve opening was assessed by echocardiography at each assessment. Bleeding and thromboembolic events were documented. RESULTS Bleeding events occurred in 14 patients (50%). Maximal platelet inhibition occurred by D30. VWF profile impairment (VWF CBA/Ag < 0.8) was demonstrated in 89% of patients at D30, with subsequent recovery but further deterioration after D180. Bleeding was associated with elevated pre-implant sGPVI (p = 0.008). Pulsatility was associated with higher VWF CBA/Ag (p = 0.02) and a trend to less bleeding. CONCLUSIONS Third-generation cfLVADs were associated with longitudinal changes in hemostatic markers, and bleeding was associated with elevated pre-implant plasma sGPVI. Further, pulsatility may contribute to recovery of the VWF profile and potentially lower bleeding risk.


Thrombosis Research | 2012

Low Concentration Detergent Sclerosants Induce Platelet Activation but Inhibit Aggregation due to Suppression of GPIIb/IIIa Activation in vitro

Kurosh Parsi; David E. Connor; Anne Pilotelle; Joyce Low; David Ma; Joanne E. Joseph

INTRODUCTION Sclerotherapy is associated with thromboembolic and ischemic neurological adverse events but the effects of sclerosants on platelet function are unknown. The aim of this study was to investigate the in vitro effects of detergent sclerosants Sodium Tetradecyl Sulphate (STS) and Polidocanol (POL) on platelet activation and aggregation. MATERIALS AND METHODS Whole blood and platelet rich plasma samples were incubated with sclerosants. Platelet and platelet microparticle (PMP) counts were measured by flow cytometry. Platelet activation was examined by ELISA for soluble factors (sP-selectin, von Willebrand factor, sCD40L and serotonin) and by flow cytometry for membrane-bound markers (CD62p, CD63) and cytoplasmic calcium. Platelet aggregation was assessed by PFA-100®, light transmission and impedance (Multiplate®) aggregometry, and by flow cytometry for glycoprotein (GP) Ib and GPIIb/IIIa subunits, heterodimer expression and activation (PAC-1 binding). RESULTS Both agents lysed platelets at high concentrations (≥ 0.1%) but induced platelet activation at lower concentrations as evident by a rise in membrane-bound and soluble markers, cytoplasmic calcium and release of phosphatidylserine+PMP. Agonist-stimulated platelet aggregation was inhibited by both sclerosants. Membrane expression of GPIb and GPIIb/IIIa individual subunits or heterodimer was not affected by sclerosants but the activation of GPIIb/IIIa was suppressed. CONCLUSION Low concentration sclerosants activated platelets and released microparticles but inhibited platelet aggregation due to suppression of GPIIb/IIIa activation.

Collaboration


Dive into the Joyce Low's collaboration.

Top Co-Authors

Avatar

Joanne E. Joseph

St. Vincent's Health System

View shared research outputs
Top Co-Authors

Avatar

David E. Connor

University of New South Wales

View shared research outputs
Top Co-Authors

Avatar

Thomas Exner

Royal Prince Alfred Hospital

View shared research outputs
Top Co-Authors

Avatar

David Ma

St. Vincent's Health System

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Kurosh Parsi

University of New South Wales

View shared research outputs
Top Co-Authors

Avatar

Margaret Aboud

Royal North Shore Hospital

View shared research outputs
Top Co-Authors

Avatar

James C. Biggs

St. Vincent's Health System

View shared research outputs
Top Co-Authors

Avatar

Elizabeth Duncan

Institute of Medical and Veterinary Science

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge