Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Jun Arai is active.

Publication


Featured researches published by Jun Arai.


international conference on biomedical engineering | 2014

Investigation of mechanical load on proximal left anterior descending of coronary artery

Tadashi Yamamoto; Kiyotaka Iwasaki; Jun Arai; Katsumi Ohori; Mitsuo Umezu

It is clinically recognized that percutaneous coronary intervention (PCI) treatment for proximal left anterior descending (LAD) artery disease is resulting in less satisfactory in comparison with other lesions. However, the reason has not yet clarified. The purpose of this study is to investigate the mechanical loading conditions in proximal LAD artery. This study hypothesized that the coronary artery is prestretched in the heart. In order to investigate the pre-stretched value, porcine heart was obtained from a local slauterhouse. Two points were marked at coronary artery and its distance was measured. Two-dimensional distances (L1) between the dots marked on vessel centerline were measured with digital microscope. The coronary artery was separated from the heart, the distance between the points was measured again (L2). Pre-stretched ratio was calculated as (L1-L2) / L2 × 100%. 101 consecutive patients of coronary CT were taken in Hokkaido Cardiovascular Hospital from September 2012 in order to investigate dynamic loads acting on coronary artery. The distance of proximal LAD artery was measured in diastolic phase (Ld) and systolic phase (Ls) from a stretch view taken from CT. Shortening ratio was defined as (Ld-Ls) / Ld × 100%. The twist angle was defined as a sum of the following two angles and mesured in end-systolic and end-diastolic phase. One is tha angle between the line connecting the centers of LAD and left circumflex (LCX), and the perpendicular line toward abdominal to dorsal. The other is the angle between the line connecting the centers of LAD and the first septal branch, and the perpendicular line. Twisting ratio was calculated as θ / Ld × 100%. Results showed that the pre-stretched ratio was calculated to be 7.6±2.9% (mean±SD) in porcine LAD artery. The length of proximal LAD artery of human coronary artery was 26.6 ± 9.3mm (mean±SD). Shortening ratio was calculated to be 6.1 ± 6.2% (mean±SD). And the mean twisting ratio was calculated to be 0.6 ° / mm. This study revealed the pre-stretched value of proximal LAD artery due to restrain from the myocardium. Moreover shortening and twisting motions in proximal LAD artery were quantified.


American Journal of Cardiology | 2013

Flexibility and Stent Fracture Potentials Against Cyclically Bending Coronary Artery Motions: Comparison Between 2-Link and 3-Link DESs

Kiyotaka Iwasaki; Sho Kishigami; Jun Arai; Takafumi Ohba; Xiaodong Zhu; Tadashi Yamamoto; Yutaka Hikichi; Mitsuo Umezu


Transactions of Japanese Society for Medical and Biological Engineering | 2014

Construction on finite element analysis method of coronary stent in cyclical bending-load environment simulated bending motion of coronary artery

Xiaodong Zhu; Kiyotaka Iwasaki; Jun Arai; Takafumi Oba; Hirotugu Tokutake; Mitsuo Umezu


The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME | 2014

2D32 屈曲負荷型加速耐久試験装置による屈曲角度変化量が冠動脈ステントの破損耐久性に及ぼす影響の検討(OS9-5:臨床バイオメカニクスと医療デバイス(5))

Jun Arai; Kiyotaka Iwasaki; Xiaodong Zhu; Takafumi Oba; Hirotsugu Tokutake; Tadashi Yamamoto; Yutaka Hikichi; Mitsuo Umezu


Circulation | 2014

Abstract 17991: Angulation Range of Coronary Artery During the Cardiac Cycles is a Key Factor Inducing Stent Fracture; Demonstration by an in vitro Accelerated Durability Test

Kiyotaka Iwasaki; Jun Arai; Takafumi Ohba; Hirotsugu Tokutake; Zhu Xiaodong; Mitsuo Umezu


Circulation | 2014

Abstract 18666: What are Key Factors to Achieve Better Stent Apposition at Left Main Bifurcation by Culottes Stenting Technique? Micro-CT Analysis Using Bifurcated Elastic Coronary Artery Models

Yutaka Hikichi; Takafumi Ohba; Tsuyoshi Inukai; Sho Kishigami; Jun Arai; Mitsuo Umezu; Koichi Node; Kiyotaka Iwasaki


Transactions of Japanese Society for Medical and Biological Engineering | 2013

Clinical results of three-time-balloon-inflation method performed in elective PCI cases

Tadashi Yamamoto; Kiyotaka Iwasaki; Jun Arai; Shigemi Kitahara; Mitsuo Umezu


The Proceedings of the JSME Conference on Frontiers in Bioengineering | 2013

A213 下肢血管ステントの破損耐久性評価のための屈曲負荷型耐久試験装置の開発(A2-3 循環器系バイオメカニクス1)

Jun Arai; Kiyotaka Iwasaki; Xiaodong Zhu; Takafumi Oba; Hirotsugu Tokutake; Tadashi Yamamoto; Yutaka Hikichi; Mitsuo Umezu


The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME | 2013

3C10 Investigation of evaluation method of bending-flexibility of coronary stents using in-vivo simulated cyclically-bended coronary artery model.

Jun Arai; Kiyotaka Iwasaki; Sho Kishigami; Takafumi Oba; Tadashi Yamamoto; Yutaka Hikichi; Mitsuo Umezu


The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME | 2013

3C09 Proposal of assessment methodology of incomplete apposition of coronary stent deployed in left main trunk bifurcation lesion using a 3-D bifurcated stenotic artery model

Takafumi Oba; Kiyotaka Iwasaki; Yutaka Hikichi; Sho Kishigami; Jun Arai; Tadashi Yamamoto; Mitsuo Umezu

Collaboration


Dive into the Jun Arai's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge