Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Jun-Mei Xu is active.

Publication


Featured researches published by Jun-Mei Xu.


Radiology | 2014

Conventional US, US Elasticity Imaging, and Acoustic Radiation Force Impulse Imaging for Prediction of Malignancy in Thyroid Nodules

Jun-Mei Xu; Xiao-Hong Xu; Hui-Xiong Xu; Yi-Feng Zhang; Jing Zhang; Le-Hang Guo; Lin-Na Liu; Chang Liu; Shu-Guang Zheng

PURPOSE To evaluate conventional ultrasonography (US), US elasticity imaging (EI), and acoustic radiation force impulse (ARFI) imaging in thyroid nodule malignancy prediction. MATERIALS AND METHODS This prospective study was institutional review board approved; informed consent was obtained. Study included 375 patients (mean age, 51 years; range, 18-75 years) with 441 pathologically proven thyroid nodules. In 281 women (mean age, 50 years; range, 18-75 years) and 94 men (mean age, 53 years; range, 18-74 years), conventional US, EI, Virtual Touch tissue imaging (VTi; Siemens, Mountain View, Calif), and Virtual Touch tissue quantification (VTq; Siemens) of ARFI imaging were performed for each nodule. Multivariate logistic regression analysis was performed to assess 17 independent variables for malignancy prediction. Diagnostic performance was evaluated with receiver operating characteristic (ROC) curve analysis. RESULTS There were 325 benign and 116 malignant nodules. Marked hypoechogenicity (odds ratio [OR]: 83.88; 95% confidence interval [CI]: 17.81, 394.99) was the strongest independent predictor for thyroid malignancy, followed by shape taller than wide (OR: 8.69; 95% CI: 2.87, 26.31), VTi (OR: 6.54; 95% CI: 3.61, 11.88), moderate hypoechogenicity (OR: 3.98; 95% CI: 1.13, 14.05), poorly defined margin (OR: 3.27; 95% CI: 1.22, 8.77), female sex (OR: 2.55; 95% CI: 1.33, 4.91), coarse background of surrounding thyroid tissue (OR: 2.01; 95% CI: 1.12, 3.62), and VTq (OR: 1.78; 95% CI: 1.28, 2.47) (all P < .05). EI was not significantly associated with thyroid malignancy (P = .855). Area under the ROC curve (Az) for VTq and VTi was higher than that with other significant independent variables. Az, sensitivity, and specificity were 0.91 (95% CI: 0.87, 0.94) and 0.86 (95% CI: 0.82, 0.90), 80% and 71.6%, and 93.8% and 83.4%, respectively, for VTi and VTq. VTq of at least 2.87 m/sec and VTi of at least grade IV were the best cutoff values for malignant thyroid nodules. CONCLUSION ARFI imaging is promising for malignant thyroid nodule prediction, with higher diagnostic performance than conventional US or EI. ARFI can be used to supplement conventional US to diagnose thyroid nodules in patients referred for surgery.


Ultrasound in Medicine and Biology | 2017

WFUMB Guidelines and Recommendations on the Clinical Use of Ultrasound Elastography: Part 4. Thyroid

David Cosgrove; Richard G. Barr; Joerg Bojunga; Vito Cantisani; Maria Cristina Chammas; Manjiri Dighe; Sudhir Vinayak; Jun-Mei Xu; Christoph F. Dietrich

The World Federation for Ultrasound in Medicine and Biology (WFUMB) has produced guidelines for the use of elastography techniques, including basic science, breast, liver and thyroid elastography. Here we present elastography in prostate diseases. For each available technique, procedure, reproducibility, results and limitations are analyzed and recommendations are given. Finally, recommendations are given based on the level of evidence of the published literature and on the WFUMB expert groups consensus. This document has a clinical perspective and is aimed at assessing the usefulness of elastography in the management of prostate diseases.


Ultrasound in Medicine and Biology | 2014

Solid hypo-echoic thyroid nodules on ultrasound: the diagnostic value of acoustic radiation force impulse elastography.

Jun-Mei Xu; Hui-Xiong Xu; Xiao-Hong Xu; Chang Liu; Yi-Feng Zhang; Le-Hang Guo; Lin-Na Liu; Jin Zhang

The aim of the study described here was to evaluate the diagnostic performance of acoustic radiation force impulse (ARFI) elastography in the differential diagnosis between benign and malignant solid hypo-echoic thyroid nodules (SHTNs) on ultrasound. In this retrospective study, 183 histologically proven SHTNs in 159 patients were enrolled. Conventional US, as well as Virtual Touch tissue imaging (VTI) and Virtual Touch tissue quantification (VTQ) of ARFI elastography, was performed on each nodule. The VTI features of SHTNs were divided into six grades, where higher grades represent harder tissue. VTQ was expressed as shear wave velocity, where higher shear wave velocity values indicate stiffer tissue. The sensitivity, specificity, accuracy, positive predictive value, negative predictive value and Youden index for ultrasound and ARFI were assessed. The 183 pathologically proven SHTNs included 117 benign and 66 malignant lesions. Nodules classified as VTI grades IV to VI were more frequently malignant (49/66, 74.2%) than benign (10/117, 8.5%) (p < 0.001). The mean shear wave velocity of VTQ for malignant SHTNs (mean ± standard deviation, 4.65 ± 2.68 m/s; range, 1.36-9 m/s) was significantly higher than that for benign SHTNs (2.34 ± 0.85 m/s, 0-5.7 m/s) (p < 0.001). The sensitivity, specificity, accuracy, positive predictive value, negative predictive value and Youden index were 27.3%-84.8%, 13.7%-89.7%, 39.3%-69.4%, 35.7%-60%, 61.5%-78.5%, and -0.015 to 0.37 for ultrasound; 68.2%, 76.9%, 73.8%, 62.5%, 81.1% and 0.451 for VTQ; and 74.2%, 91.5%, 85.2%, 83.1%, 86.3% and 0.657 for VTI, respectively. ARFI elastography performed at a superior level, compared with conventional ultrasound, in the differential diagnosis between malignant and benign SHTNs. The diagnostic performance of VTI is higher than that of VTQ.


Ultrasound in Medicine and Biology | 2017

WFUMB Guidelines and Recommendations on the Clinical Use of Ultrasound ElastographyWFUMB Guidelines and Recommendations on the Clinical Use of Ultrasound Elastography: Part 4. Thyroid

David Cosgrove; Richard G. Barr; Joerg Bojunga; Vito Cantisani; Maria Cristina Chammas; Manjiri Dighe; Sudhir Vinayak; Jun-Mei Xu; Christoph F. Dietrich

The World Federation for Ultrasound in Medicine and Biology (WFUMB) has produced guidelines for the use of elastography techniques including basic science, breast and liver. Here we present elastography in thyroid diseases. For each available technique, procedure, reproducibility, results and limitations are analyzed and recommendations are given. Finally, recommendations are given based on the level of evidence of the published literature and on the WFUMB expert groups consensus. The document has a clinical perspective and is aimed at assessing the usefulness of elastography in the management of thyroid diseases.


British Journal of Radiology | 2016

Treatment efficacy and safety of ultrasound-guided percutaneous bipolar radiofrequency ablation for benign thyroid nodules

Xiao-Long Li; Hui-Xiong Xu; Feng Lu; Wen-Wen Yue; Li-Ping Sun; Xiao-Wan Bo; Le-Hang Guo; Jun-Mei Xu; Bo-Ji Liu; Dan-Dan Li; Shen Qu

OBJECTIVE To evaluate the therapeutic efficacy and safety of ultrasound-guided percutaneous bipolar radiofrequency ablation (BRFA) of benign thyroid nodules by comparison with a matched untreated control group. METHODS The therapeutic efficacy and safety in 35 patients who were subjected to a single session of ultrasound-guided percutaneous BRFA (Group A) for benign thyroid nodules were compared with those in 35 untreated patients (Group B) with benign nodules. The benign nature of all the nodules was confirmed by ultrasound-guided fine-needle aspiration biopsy (FNAB), and all the patients had normal thyroid functions. BRFA was performed with a bipolar electrode (CelonProSurge 150-T20) with an output power of 20 W. Nodule volume, thyroid function and clinical symptoms of all the patients were compared before treatment and during follow-up. RESULTS In Group A, the BRFA procedures were completed with a mean time of 10.02 ± 3.30 min (range, 5.47-16.03 min) and with a mean total energy deposition of 10.747 ± 3704 J (range, 5510-17.770 J). The procedures were tolerated well in all the patients without causing any major complications. At the 6-month follow-up, all of the nodule volume decreased significantly (from 8.81 ± 8.66 to 1.59 ± 1.55 ml, p < 0.001) in Group A, whereas the nodule volume increased from 6.90 ± 3.77 to 7.87 ± 3.95 ml in Group B (p < 0.001). All (100%) the 35 nodules in Group A had volume reduction ratios (VRRs) of >50%, among which 3 (8.57%) had VRRs >90%. In Group A, the clinical symptoms of the patients who had symptoms before BRFA disappeared, whereas in Group B, the patients had no resolution of clinical symptoms at the 6-month follow-up. CONCLUSION Ultrasound-guided percutaneous BRFA seems to be an effective and safe method for the treatment of benign thyroid nodules. It may gain a wide use in clinical practice. ADVANCES IN KNOWLEDGE Based on the comparable efficacy and clinical symptoms between the BRFA and untreated groups, the technique of BRFA can be used as an effective and safe method for the treatment of benign thyroid nodules.


BioMed Research International | 2014

Acoustic Radiation Force Impulse Imaging: A New Tool for the Diagnosis of Papillary Thyroid Microcarcinoma

Yi-Feng Zhang; Chang Liu; Hui-Xiong Xu; Jun-Mei Xu; Jing Zhang; Le-Hang Guo; Shu-Guang Zheng; Lin-Na Liu; Xiao-Hong Xu

Purpose. To evaluate the diagnostic performance of ARFI imaging in differentiating between benign and malignant thyroid nodules <1 cm. Materials and Methods. 173 pathologically proven thyroid nodules (77 benign, 96 malignant) in 157 patients were included in this study. Receiver-operating characteristic curve (ROC) analyses were performed to assess the diagnostic performance of conventional ultrasound (US) and ARFI imaging in papillary thyroid microcarcinoma (PTMC). The independent risk factors for predicting PTMC were evaluated. Results. The mean SWV value of benign and malignant thyroid nodules were 2.57 ± 0.79 m/s (range: 0.90–4.92 m/s) and 3.88 ± 2.24 m/s (range: 1.49–9.00 m/s) (P = 0.000). Az for VTI elastography score was higher than that for hypoechoic, absence of halo sign, and type III vascularity (P < 0.05). The optimal cut-offs for VTI elastography score and SWV were score 4 and 3.10 m/s. Gender, hypoechoic, taller than wide, VTI elastography score ≥ 4, and SWV > 3.10 m/s had been found to be independent risk factors for predicting PTMC. Conclusion. ARFI elastography can provide elasticity information of PTMC quantitatively (VTQ) and directly reflects the overall elastic properties (VTI). Gender, hypoechogenicity, taller than wide, VTI elastography score ≥ 4, and SWV > 3.10 m/s are independent risk factors for predicting PTMC. ARFI elastography seems to be a new tool for the diagnosis of PTMC.


Medicine | 2015

Acoustic Radiation Force Impulse Elastography: A Useful Tool for Differential Diagnosis of Thyroid Nodules and Recommending Fine-Needle Aspiration: A Diagnostic Accuracy Study

Yi-Feng Zhang; Jun-Mei Xu; Hui-Xiong Xu; Chang Liu; Xiao-Wan Bo; Xiao-Long Li; Le-Hang Guo; Bo-Ji Liu; Lin-Na Liu; Xiao-Hong Xu

Abstract To investigate the diagnostic performance of combined use of conventional ultrasound (US) and elastography, including conventional strain elastography such as elasticity imaging (EI) and acoustic radiation force impulse (ARFI) elastography, and to evaluate their usefulness in recommending fine-needle aspiration (FNA). A total of 556 pathologically proven thyroid nodules were evaluated by US, EI, and ARFI examinations in this study. Three blinded readers scored the likelihood of malignancy for 4 datasets (ie, US alone, US and EI, US and virtual touch tissue imaging [VTI], and US and virtual touch tissue quantification [VTQ]). The diagnostic performances of 4 datasets in differentiating malignant from benign thyroid nodules were evaluated. The decision-making changes for FNA recommendation in the indeterminate nodules or the probably benign nodules on conventional US were evaluated after review of elastography. The diagnostic performance in terms of area under the ROC curve did not show any change after adding EI, VTI, or VTQ for analysis; and no differences were found among different readers; however, the specificity and positive predictive value (PPV) improved significantly after adding VTI or VTQ for analysis in the senior reader. For the indeterminate nodules on US that were pathologically benign, VTQ made correct decision-making changes from FNA biopsy to follow-up in a mean of 82.6% nodules, which was significantly higher than those achieved by EI (46.8%) and VTI (54.4%) (both P < 0.05). With regard to the probably benign nodules on US that were pathologically malignant, EI made the highest correct decision-making change from follow-up to FNA biopsy in a mean of 62.6% nodules (compared with 41.5% on VTQ, P < 0.05). The results indicated that ARFI increases the specificity and PPV in diagnosing thyroid nodules. US combined VTQ might be helpful in reducing unnecessary FNA for indeterminate nodules on US whereas US combined EI is useful to detect the false negative nodules that are probably benign on conventional US.


Clinical Hemorheology and Microcirculation | 2017

Comparison of virtual touch tissue imaging & quantification (VTIQ) and Virtual touch tissue quantification (VTQ) for diagnosis of thyroid nodules

Yu-Ping Yang; Xiao-Hong Xu; Hui-Xiong Xu; Xiao-Wan Bo; Bo-Ji Liu; Le-Hang Guo; Jun-Mei Xu; Li-Ping Sun

OBJECTIVE The aim of this study was to compare the diagnostic performance of Virtual Touch Tissue Imaging & Quantification (VTIQ) and Virtual Touch Tissue Quantification (VTQ) in differentiating benign from malignant thyroid nodules (TNs). MATERIALS AND METHODS In this study 107 TNs in 107 patients were enrolled and analyzed. All of them were detected by conventional ultrasound (US) and confirmed by fine-needle aspiration (FNA) biopsy or surgery. VTIQ and VTQ examinations were performed on each nodule. Thereafter the median and mean of shear wave speed (SWS) values in lesions on VTIQ and VTQ were computed (SWS-median and SWS-mean). With cytological results of FNA and histological results adopted as the reference standard, area under the receiver operating characteristic (AUROC) curve analysis was performed to evaluate the diagnostic efficiency of VTIQ and VTQ in differentiation of TNs. RESULTS Among the 107 lesions, 19 were papillary thyroid carcinomas (PTCs), 1 was medullary thyroid carcinoma (MTC) and 87 were benign. In total lesions, AUROC-median in VTIQ was significantly higher than that in VTQ (0.851 vs.0.759; p < 0.05). CONCLUSION VTIQ and VTQ were equivalent in diagnosing TNs when using SWS-mean, whereas VTIQ showed better performance in comparison with VTQ when using SWS-median.


Scientific Reports | 2015

Comparison between Ultrasound Guided Transperineal and Transrectal Prostate Biopsy: A Prospective, Randomized, and Controlled Trial.

Le-Hang Guo; Rong Wu; Hui-Xiong Xu; Jun-Mei Xu; Jian Wu; Shuai Wang; Xiao-Wan Bo; Bo-Ji Liu

This prospective study of comparing transperineal prostate biopsy (TPBx) with transrectal prostate biopsy (TRBx) was aimed to provide evidence for clinicians to select the appropriate biopsy approach under different conditions. TPBx (n = 173) and TRBx (n = 166) were performed randomly for 339 patients who were suspicious of prostate cancer (PCa). The cancer detection rate (CDR), complication rate, visual analogue scale (VAS) score, most painful procedure, number of repeated biopsy and additional anesthesia, and operating time (starting from lying down on the operating table to getting up) were recorded. The results showed that TPBx and TRBx were equivalent in CDR (35.3% vs. 31.9%) and minor complication rate (44.9% vs. 41.0%) (both P > 0.05). The major complication rate was lower in TPBx than in TRBx (0.6% vs. 4.3%, P < 0.05). TPBx was more time-consuming (17.51 ± 3.33 min vs. 14.73 ± 3.25 min) and painful (VAS score: 4.0 vs. 2.0); and it had higher rates of repeated biopsy (3.2% vs. 1.1%) and additional anesthesia (15.0% vs. 1.2%) (all P < 0.05). In summary, both TPBx and TRBx are effective to detect PCa. The major complication rate for TRBx is higher, whereas TPBx procedure is more complex and painful.


Clinical Hemorheology and Microcirculation | 2013

Parametric imaging with contrast-enhanced ultrasound: usefulness for characterization of dynamic effects of microvascularization for hepatocellular carcinoma and focal nodular hyperplasia.

Shu-Guang Zheng; Hui-Xiong Xu; Lin-Na Liu; Yan Wang; Yi-Feng Zhang; Le-Hang Guo; Chang Liu; Jun-Mei Xu; Li-Ping Sun; Jian Wu

OBJECTIVE To evaluate whether parametric imaging with contrast-enhanced ultrasound (CEUS) is equal to experienced radiologists after review of CEUS in differentiating hepatocellular carcinoma (HCC) from focal nodular hyperplasia (FNH). METHODS An image processing software was used to quantitatively analyze the CEUS clips of 30 HCCs (mean diameter, 3.4±0.9 cm; range, 1.8-5.0 cm) and 30 FNHs (mean diameter, 3.0±1.1 cm; range, 1.1-5.0 cm). Low mechanical index contrast specific imaging modes and contrast agent of SonoVue® were applied for CEUS. Fourteen HCCs were pathologically diagnosed and 16 were clinically diagnosed, whereas all the FNHs were confirmed by pathological examination. Quantitative parameters of HCC and FNH were compared. The diagnostic performance between parametric imaging and two experienced readers was compared using the receiver operating characteristic (ROC) curve analysis. RESULTS On parametric imaging, the rise time, time to peak and mean transit time for HCC and FNH were 16.7±11.1 s vs. 21.9±9.0 s (P=0.052), 29.9±14.1 s vs. 33.2±11.1 s (P=0.322), 115.0±90.9 s vs. 271.5±147.6 s (P<0.001), respectively. The ROC analysis showed that, for the differentiation between HCC and FNH, the cut-off point for mTT was 107.93 s with the Az value of 0.817 (95% CI: 0.703-0.931), and the Az value was 0.834 (95%CI: 0.728-0.941) for two experienced readers (P=0.417 compared with mTT). The sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) were 96.7%, 66.7%, 81.7%, 74.4%, and 95.2%, respectively, for parametric imaging, and 86.7%, 76.7%, 81.7%, 78.8%, and 85.2%, respectively, for two experienced readers (all P>0.05 compared with parametric imaging). CONCLUSION Parametric imaging with CEUS is helpful for characterization the typical dynamic effects of microvascularization of HCC and FHH and is equal to experienced readers in the differential diagnosis between HCC and FNH.

Collaboration


Dive into the Jun-Mei Xu's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Xiao-Hong Xu

Guangdong Medical College

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge