Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Lin-Na Liu is active.

Publication


Featured researches published by Lin-Na Liu.


PLOS ONE | 2012

Virtual Touch Tissue Quantification of Acoustic Radiation Force Impulse: A New Ultrasound Elastic Imaging in the Diagnosis of Thyroid Nodules

Yi-Feng Zhang; Hui-Xiong Xu; Yong He; Chang Liu; Le-Hang Guo; Lin-Na Liu; Jun-Mei Xu

Objective Virtual touch tissue quantification (VTQ) of acoustic radiation force impulse (ARFI) is a new quantitative technique to measure tissue stiffness. The study was aimed to assess the usefulness of VTQ in the diagnosis of thyroid nodules. Methods 173 pathologically proven thyroid nodules in 142 patients were included and all were examined by conventional ultrasound (US), conventional elasticity imaging (EI) and VTQ of ARFI. The tissue stiffness for VTQ was expressed as shear wave velocity (SWV) (m/s). Receiver-operating characteristic curve (ROC) analyses were performed to assess the diagnostic performance. Intra- and inter-observer reproducibility of VTQ measurement was assessed. Results The SWVs of benign and malignant thyroid nodules were 2.34±1.17 m/s (range: 0.61–9.00 m/s) and 4.82±2.53 m/s (range: 2.32–9.00 m/s) respectively (P<0.001). The mean SWV ratios between each nodule and the adjacent thyroid tissue were 1.19±0.67 (range: 0.31–6.87) for benign and 2.50±1.54 (range: 0.85–6.69) for malignant nodules (P<0.001). ROC analyses indicated that the area under the curve was 0.861 (95% CI : 0.804, 0.918) (P<0.001) for SWV and 0.831(95% CI : 0.761, 0.900)(P<0.001) for the SWV ratio. The cutoff points for the differential diagnosis were 2.87 m/s for SWV and 1.59 for SWV ratio. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value for EI were 65.9%, 66.7%, 66.5%, 40.3%, and 85.1%, respectively, and were 63.6%–75%, 82.2%–88.4%, 80.3%–82.1%, 58.9%–65.1%, and 87.7%–90.5%, respectively, for VTQ. The diagnostic value of VTQ is the highest for nodules >20 mm and lowest for those ≤10 mm. The correlation coefficients were 0.904 for intraobserver measurement and 0.864 for interobserver measurement. Conclusions VTQ of ARFI provides quantitative and reproducible information about the tissue stiffness, which is useful for the differentiation between benign and malignant thyroid nodules. The diagnostic performance of VTQ is higher than that of conventional EI.


Radiology | 2014

Conventional US, US Elasticity Imaging, and Acoustic Radiation Force Impulse Imaging for Prediction of Malignancy in Thyroid Nodules

Jun-Mei Xu; Xiao-Hong Xu; Hui-Xiong Xu; Yi-Feng Zhang; Jing Zhang; Le-Hang Guo; Lin-Na Liu; Chang Liu; Shu-Guang Zheng

PURPOSE To evaluate conventional ultrasonography (US), US elasticity imaging (EI), and acoustic radiation force impulse (ARFI) imaging in thyroid nodule malignancy prediction. MATERIALS AND METHODS This prospective study was institutional review board approved; informed consent was obtained. Study included 375 patients (mean age, 51 years; range, 18-75 years) with 441 pathologically proven thyroid nodules. In 281 women (mean age, 50 years; range, 18-75 years) and 94 men (mean age, 53 years; range, 18-74 years), conventional US, EI, Virtual Touch tissue imaging (VTi; Siemens, Mountain View, Calif), and Virtual Touch tissue quantification (VTq; Siemens) of ARFI imaging were performed for each nodule. Multivariate logistic regression analysis was performed to assess 17 independent variables for malignancy prediction. Diagnostic performance was evaluated with receiver operating characteristic (ROC) curve analysis. RESULTS There were 325 benign and 116 malignant nodules. Marked hypoechogenicity (odds ratio [OR]: 83.88; 95% confidence interval [CI]: 17.81, 394.99) was the strongest independent predictor for thyroid malignancy, followed by shape taller than wide (OR: 8.69; 95% CI: 2.87, 26.31), VTi (OR: 6.54; 95% CI: 3.61, 11.88), moderate hypoechogenicity (OR: 3.98; 95% CI: 1.13, 14.05), poorly defined margin (OR: 3.27; 95% CI: 1.22, 8.77), female sex (OR: 2.55; 95% CI: 1.33, 4.91), coarse background of surrounding thyroid tissue (OR: 2.01; 95% CI: 1.12, 3.62), and VTq (OR: 1.78; 95% CI: 1.28, 2.47) (all P < .05). EI was not significantly associated with thyroid malignancy (P = .855). Area under the ROC curve (Az) for VTq and VTi was higher than that with other significant independent variables. Az, sensitivity, and specificity were 0.91 (95% CI: 0.87, 0.94) and 0.86 (95% CI: 0.82, 0.90), 80% and 71.6%, and 93.8% and 83.4%, respectively, for VTi and VTq. VTq of at least 2.87 m/sec and VTi of at least grade IV were the best cutoff values for malignant thyroid nodules. CONCLUSION ARFI imaging is promising for malignant thyroid nodule prediction, with higher diagnostic performance than conventional US or EI. ARFI can be used to supplement conventional US to diagnose thyroid nodules in patients referred for surgery.


PLOS ONE | 2013

Acoustic Radiation Force Impulse Imaging for Noninvasive Evaluation of Renal Parenchyma Elasticity: Preliminary Findings

Le-Hang Guo; Hui-Xiong Xu; Hui-Jun Fu; Ai Peng; Yi-Feng Zhang; Lin-Na Liu

Objective To evaluate the diagnostic value of acoustic radiation force impulse (ARFI) to test the elasticity of renal parenchyma by measuring the shear wave velocity (SWV) which might be used to detect chronic kidney disease (CKD). Methods 327 healthy volunteers and 64 CKD patients were enrolled in the study. The potential influencing factors and measurement reproducibility were evaluated in the healthy volunteers. Correlations between SWV and laboratory tests were analyzed in CKD patients.?Receiver-operating characteristic curve (ROC) analyses were performed to assess the diagnostic performance of ARFI. Results The SWV of healthy volunteers correlated significantly to age (r = −0.22, P<0.001, n = 327) and differed significantly between men and women (2.06±0.48 m/s vs. 2.2±0.52 m/s, P = 0.018, n = 327). However, it did not correlate significantly to height, weight, body mass index, waistline, kidney dimension and the depth for SWV measurement (n = 30). Inter- and intraobserver agreement expressed as intraclass coefficient correlation were 0.64 (95% CI: 0.13 to 0.82, P = 0.011) and 0.6 (95% CI: 0.31 to 0.81, P = 0.001) (n = 40). The mean SWV in healthy volunteers was 2.15±0.51 m/s, while was 1.81±0.43 m/s, 1.79±0.29 m/s, 1.81±0.44 m/s, 1.64±0.55 m/s, and 1.36±0.17 m/s for stage 1, 2, 3, 4 and 5 in CKD patients respectively. The SWV was significantly higher for healthy volunteers compared with each stage in CKD patients. ARFI could not predict the different stages of CKD except stage 5. In CKD patients, SWV correlated to e-GFR (r = 0.3, P = 0.018), to urea nitrogen (r =  −0.3, P = 0.016), and to creatinine (r =  −0.41, P = 0.001). ROC analyses indicated that the area under the ROC curve was 0.752 (95% CI: 0.704 to 0.797) (P<0.001). The cut-off value for predicting CKD was 1.88 m/s (sensitivity 71.87% and specificity 69.69%). Conclusion ARFI may be a potentially useful tool in detecting CKD.


PLOS ONE | 2012

Contrast-Enhanced Ultrasound in the Diagnosis of Gallbladder Diseases: A Multi-Center Experience

Lin-Na Liu; Hui-Xiong Xu; Ming-De Lu; Xiao-Yan Xie; Wen-Ping Wang; Bing Hu; K. Yan; Hong Ding; Shao-Shan Tang; Lin-Xue Qian; Bao-Ming Luo; Yan-Ling Wen

Objective To assess the usefulness of contrast–enhanced ultrasound (CEUS) in differentiating malignant from benign gallbladder (GB) diseases. Methods This study had institutional review board approval. 192 patients with GB diseases from 9 university hospitals were studied. After intravenous bonus injection of a phospholipid-stabilized shell microbubble contrast agent, lesions were scanned with low acoustic power CEUS. A multiple logistic regression analysis was performed to identify diagnostic clues from 17 independent variables that enabled differentiation between malignant and benign GB diseases. Receiver operating characteristic (ROC) curve analysis was performed. Results Among the 17 independent variables, multiple logistic regression analysis showed that the following 4 independent variables were associated with the benign nature of the GB diseases, including the patient age, intralesional blood vessel depicted on CEUS, contrast washout time, and wall intactness depicted on CEUS (all P<0.05). ROC analysis showed that the patient age, intralesional vessels on CEUS, and the intactness of the GB wall depicted on CEUS yielded an area under the ROC curve (Az) greater than 0.8 in each and Az for the combination of the 4 significant independent variables was 0.915 [95% confidence interval (CI): 0.857–0.974]. The corresponding Az, sensitivity, and specificity for the age were 0.805 (95% CI: 0.746–0.863), 92.2%%, and 59.6%; for the intralesional vessels on CEUS were 0.813 (95% CI: 0.751–0.875), 59.8%, and 98.0%; and for the GB wall intactness were 0.857 (95% CI: 0.786–0.928), 78.4%, and 92.9%. The cut-off values for benign GB diseases were patient age <53.5 yrs, dotted intralesional vessels on CEUS and intact GB wall on CEUS. Conclusion CEUS is valuable in differentiating malignant from benign GB diseases. Branched or linear intralesional vessels and destruction of GB wall on CEUS are the CEUS features highly suggestive of GB malignancy and the patient age >53.5 yrs is also a clue for GB malignancy.


Journal of Ultrasound in Medicine | 2014

Virtual touch tissue imaging on acoustic radiation force impulse elastography: a new technique for differential diagnosis between benign and malignant thyroid nodules.

Yi-Feng Zhang; Yong He; Hui-Xiong Xu; Xiao-Hong Xu; Chang Liu; Le-Hang Guo; Lin-Na Liu; Jun-Mei Xu

Acoustic radiation force impulse elastography is a newly developed ultrasound elasticity imaging technique that included both Virtual Touch tissue quantification and Virtual Touch tissue imaging (VTI; Siemens Medical Solutions, Mountain View, CA). This study aimed to evaluate the usefulness of VTI in differentiating malignant from benign thyroid nodules.


Ultrasound in Medicine and Biology | 2014

Solid hypo-echoic thyroid nodules on ultrasound: the diagnostic value of acoustic radiation force impulse elastography.

Jun-Mei Xu; Hui-Xiong Xu; Xiao-Hong Xu; Chang Liu; Yi-Feng Zhang; Le-Hang Guo; Lin-Na Liu; Jin Zhang

The aim of the study described here was to evaluate the diagnostic performance of acoustic radiation force impulse (ARFI) elastography in the differential diagnosis between benign and malignant solid hypo-echoic thyroid nodules (SHTNs) on ultrasound. In this retrospective study, 183 histologically proven SHTNs in 159 patients were enrolled. Conventional US, as well as Virtual Touch tissue imaging (VTI) and Virtual Touch tissue quantification (VTQ) of ARFI elastography, was performed on each nodule. The VTI features of SHTNs were divided into six grades, where higher grades represent harder tissue. VTQ was expressed as shear wave velocity, where higher shear wave velocity values indicate stiffer tissue. The sensitivity, specificity, accuracy, positive predictive value, negative predictive value and Youden index for ultrasound and ARFI were assessed. The 183 pathologically proven SHTNs included 117 benign and 66 malignant lesions. Nodules classified as VTI grades IV to VI were more frequently malignant (49/66, 74.2%) than benign (10/117, 8.5%) (p < 0.001). The mean shear wave velocity of VTQ for malignant SHTNs (mean ± standard deviation, 4.65 ± 2.68 m/s; range, 1.36-9 m/s) was significantly higher than that for benign SHTNs (2.34 ± 0.85 m/s, 0-5.7 m/s) (p < 0.001). The sensitivity, specificity, accuracy, positive predictive value, negative predictive value and Youden index were 27.3%-84.8%, 13.7%-89.7%, 39.3%-69.4%, 35.7%-60%, 61.5%-78.5%, and -0.015 to 0.37 for ultrasound; 68.2%, 76.9%, 73.8%, 62.5%, 81.1% and 0.451 for VTQ; and 74.2%, 91.5%, 85.2%, 83.1%, 86.3% and 0.657 for VTI, respectively. ARFI elastography performed at a superior level, compared with conventional ultrasound, in the differential diagnosis between malignant and benign SHTNs. The diagnostic performance of VTI is higher than that of VTQ.


BioMed Research International | 2014

Acoustic Radiation Force Impulse Imaging: A New Tool for the Diagnosis of Papillary Thyroid Microcarcinoma

Yi-Feng Zhang; Chang Liu; Hui-Xiong Xu; Jun-Mei Xu; Jing Zhang; Le-Hang Guo; Shu-Guang Zheng; Lin-Na Liu; Xiao-Hong Xu

Purpose. To evaluate the diagnostic performance of ARFI imaging in differentiating between benign and malignant thyroid nodules <1 cm. Materials and Methods. 173 pathologically proven thyroid nodules (77 benign, 96 malignant) in 157 patients were included in this study. Receiver-operating characteristic curve (ROC) analyses were performed to assess the diagnostic performance of conventional ultrasound (US) and ARFI imaging in papillary thyroid microcarcinoma (PTMC). The independent risk factors for predicting PTMC were evaluated. Results. The mean SWV value of benign and malignant thyroid nodules were 2.57 ± 0.79 m/s (range: 0.90–4.92 m/s) and 3.88 ± 2.24 m/s (range: 1.49–9.00 m/s) (P = 0.000). Az for VTI elastography score was higher than that for hypoechoic, absence of halo sign, and type III vascularity (P < 0.05). The optimal cut-offs for VTI elastography score and SWV were score 4 and 3.10 m/s. Gender, hypoechoic, taller than wide, VTI elastography score ≥ 4, and SWV > 3.10 m/s had been found to be independent risk factors for predicting PTMC. Conclusion. ARFI elastography can provide elasticity information of PTMC quantitatively (VTQ) and directly reflects the overall elastic properties (VTI). Gender, hypoechogenicity, taller than wide, VTI elastography score ≥ 4, and SWV > 3.10 m/s are independent risk factors for predicting PTMC. ARFI elastography seems to be a new tool for the diagnosis of PTMC.


Ultraschall in Der Medizin | 2012

Imaging features of intrahepatic biliary cystadenoma and cystadenocarcinoma on B-mode and contrast-enhanced ultrasound.

H.-X. Xu; M.-D. Lu; Lin-Na Liu; Yi Feng Zhang; Le-Hang Guo; Chun Liu; S. Wang

PURPOSE To investigate the imaging features of intrahepatic biliary cystadenoma and cystadenocarcinoma on B-mode and contrast-enhanced ultrasound. MATERIALS AND METHODS The B-mode and contrast-enhanced ultrasound features of 6 intrahepatic biliary cystadenomas and 7 intrahepatic biliary cystadenocarcinomas were retrospectively analyzed, and the differences between cystadenomas and cystadenocarcinomas were compared. RESULTS There were no significant differences between cystadenomas and cystadenocarcinomas in terms of patient gender, age, lesion location, size, and shape (all p > 0.05). On conventional ultrasound, biliary cystadenomas were more likely to be multilocular (6/6 for cystadenoma vs. 2/7 for cystadenocarcinoma) and cystadenocarcinomas more likely presented the features of a mural or septal nodule and a nodule diameter > 1.0 cm (0/6 for cystadenoma vs. 5/7 for cystadenocarcinoma). On contrast-enhanced ultrasound, hyper-enhancement (n = 4) or iso-enhancement (n = 2) was present in the cystic wall, septations or mural nodules of the cystadenomas during the arterial phase and the enhancement washed out to hypo-enhancement (n = 6) during the late phase. Cystadenocarcinomas also showed hyper-enhancement (n = 4) or iso-enhancement (n = 3) in the cystic wall, septations or mural nodules during the arterial phase and iso-enhancement (n = 1) or hypo-enhancement (n = 6) during the late phase. CONCLUSION Intrahepatic biliary cystadenomas are more typically multilocular cystic lesions. A mural or septal nodule and a nodule diameter greater than 1.0 cm on conventional ultrasound are suggestive of cystadenocarcinomas. Contrast-enhanced ultrasound is helpful for depicting the vascularity of the lesions but there was no significant difference between cystadenomas and cystadenocarcinomas.


Medicine | 2015

Acoustic Radiation Force Impulse Elastography: A Useful Tool for Differential Diagnosis of Thyroid Nodules and Recommending Fine-Needle Aspiration: A Diagnostic Accuracy Study

Yi-Feng Zhang; Jun-Mei Xu; Hui-Xiong Xu; Chang Liu; Xiao-Wan Bo; Xiao-Long Li; Le-Hang Guo; Bo-Ji Liu; Lin-Na Liu; Xiao-Hong Xu

Abstract To investigate the diagnostic performance of combined use of conventional ultrasound (US) and elastography, including conventional strain elastography such as elasticity imaging (EI) and acoustic radiation force impulse (ARFI) elastography, and to evaluate their usefulness in recommending fine-needle aspiration (FNA). A total of 556 pathologically proven thyroid nodules were evaluated by US, EI, and ARFI examinations in this study. Three blinded readers scored the likelihood of malignancy for 4 datasets (ie, US alone, US and EI, US and virtual touch tissue imaging [VTI], and US and virtual touch tissue quantification [VTQ]). The diagnostic performances of 4 datasets in differentiating malignant from benign thyroid nodules were evaluated. The decision-making changes for FNA recommendation in the indeterminate nodules or the probably benign nodules on conventional US were evaluated after review of elastography. The diagnostic performance in terms of area under the ROC curve did not show any change after adding EI, VTI, or VTQ for analysis; and no differences were found among different readers; however, the specificity and positive predictive value (PPV) improved significantly after adding VTI or VTQ for analysis in the senior reader. For the indeterminate nodules on US that were pathologically benign, VTQ made correct decision-making changes from FNA biopsy to follow-up in a mean of 82.6% nodules, which was significantly higher than those achieved by EI (46.8%) and VTI (54.4%) (both P < 0.05). With regard to the probably benign nodules on US that were pathologically malignant, EI made the highest correct decision-making change from follow-up to FNA biopsy in a mean of 62.6% nodules (compared with 41.5% on VTQ, P < 0.05). The results indicated that ARFI increases the specificity and PPV in diagnosing thyroid nodules. US combined VTQ might be helpful in reducing unnecessary FNA for indeterminate nodules on US whereas US combined EI is useful to detect the false negative nodules that are probably benign on conventional US.


Clinical Radiology | 2012

Magnetic navigation in ultrasound-guided interventional radiology procedures

H.-X. Xu; M.-D. Lu; Lin-Na Liu; Le-Hang Guo

AIM To evaluate the usefulness of magnetic navigation in ultrasound (US)-guided interventional procedures. MATERIALS AND METHODS Thirty-seven patients who were scheduled for US-guided interventional procedures (20 liver cancer ablation procedures and 17 other procedures) were included. Magnetic navigation with three-dimensional (3D) computed tomography (CT), magnetic resonance imaging (MRI), 3D US, and position-marking magnetic navigation were used for guidance. The influence on clinical outcome was also evaluated. RESULTS Magnetic navigation facilitated applicator placement in 15 of 20 ablation procedures for liver cancer in which multiple ablations were performed; enhanced guidance in two small liver cancers invisible on conventional US but visible at CT or MRI; and depicted the residual viable tumour after transcatheter arterial chemoembolization for liver cancer in one procedure. In four of 17 other interventional procedures, position-marking magnetic navigation increased the visualization of the needle tip. Magnetic navigation was beneficial in 11 (55%) of 20 ablation procedures; increased confidence but did not change management in five (25%); added some information but did not change management in two (10%); and made no change in two (10%). In the other 17 interventional procedures, the corresponding numbers were 1 (5.9%), 2 (11.7%), 7 (41.2%), and 7 (41.2%), respectively (p=0.002). CONCLUSION Magnetic navigation in US-guided interventional procedure provides solutions in some difficult cases in which conventional US guidance is not suitable. It is especially useful in complicated interventional procedures such as ablation for liver cancer.

Collaboration


Dive into the Lin-Na Liu's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Xiao-Hong Xu

Guangdong Medical College

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge