Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where K. Dauber is active.

Publication


Featured researches published by K. Dauber.


Europace | 2016

Radiation risk reduction in cardiac electrophysiology through use of a gridless imaging technique.

Ian R. Smith; W. Stafford; J. Hayes; Michael C. Adsett; K. Dauber; J. Rivers

AIMS It has been previously demonstrated that use of appropriate frame rates coupled with minimal use of high-dose digital acquisition can limit radiation risk to patients undergoing diagnostic and therapeutic electrophysiology (EP). Imaging without the anti-scatter grid has been proposed as a means of achieving further radiation reduction. We evaluate application of a gridless imaging technique to deliver further reductions in radiation risk to both patients and personnel. METHODS AND RESULTS Radiation and clinical data for EP procedures performed for 16 months from March 2012 were monitored. The period was divided into three phases: Phase 1 (March 2012-June 2012) provided a performance baseline (radiation output modelling and procedural risk adjustment calibration), Phase 2 (July 2012-September 2012) confirmation of performance with the grid, and Phase 3 (September 2012-June 2013) gridless imaging period. Statistical process control (SPC) charts were used to monitor for changes in radiation use and clinical outcomes (procedural success). Imaging without the grid halved the levels of radiation delivered in undertaking EP procedures. Although there was a perceptible impact on image quality with the grid removed. Review of the SPC chart monitoring procedural outcomes did not identify any discernable adverse impact on success rates. Selected use of the gridless technique is recommended with re-introduction of the grid in larger patients or during aspects of the procedure where image quality is important (e.g. transeptal punctures). CONCLUSION Use of a gridless imaging technique can contribute to a significant reduction in radiation risk to both patients and operators during cardiac EP procedures.


Journal of Cardiovascular Electrophysiology | 2016

Characteristics of Cavotricuspid Isthmus Ablation for Atrial Flutter Guided by Novel Parameters Using a Contact Force Catheter.

Paul A. Gould; C. Booth; K. Dauber; Kevin Ng; Andrew Claughton; G. Kaye

This study sought to investigate specific contact force (CF) parameters to guide cavotricuspid isthmus (CTI) ablation and compare the outcome with a historical control cohort.


Heart Lung and Circulation | 2015

A Comparison of Right Ventricular Non-apical Defibrillator Lead Position with Traditional Right Ventricular Apical Position: A Single Centre Experience

G. Kaye; L. Eng; Benjamin J. Hunt; K. Dauber; J. Hill; Paul A. Gould

BACKGROUND Implantable cardioverter defibrillator (ICD) leads have traditionally been placed at the right ventricular apex (RVA). An important minority of patients with an ICD may develop a future requirement for bradycardia support. Pacing from the RVA may be detrimental, promoting heart failure and mortality. Increasingly non-apical right ventricular (RVNA) lead positions have been suggested as an alternative pacing site. METHODS A retrospective review of 512 patients who received an ICD at our institution between 1999 and 2011 was conducted. A comparison of lead performance characteristics was performed between RVNA sites and those at RVA. Data were collated from chart review and the pacing database. RESULTS The mean follow-up period in the RVNA cohort was 40.4±25.9 months and in the RVA cohort it was 38±31.8 months (p=0.43). The RVNA cohort consisted of 144 leads and 368 leads in the RVA cohort. The groups had similar baseline clinical characteristics. No significant difference was detected in the proportion of patients receiving an appropriate ICD defibrillation (RVNA 10.4% vs. RVA 16.8%; p=0.07), inappropriate defibrillation (RVNA 7.6% vs. RVA 7.6%; p=0.99) or an unsuccessful defibrillation (RVNA 0% vs. RVA 1.7%; p=0.12). There was also no significant difference in the proportion of patients receiving successful anti-tachycardia pacing (ATP) (RVNA 13.2% vs. RVA 17.4%; p=0.49) or failed ATP (RVNA 2.7% vs. RVA 4.1%; p=0.25). There was no significant difference in lead impedance (p=0.99), sensing (p=0.59) and pacing threshold (p=0.34). CONCLUSION In this large retrospective study, RVNA ICD lead had similar stability and therapy efficacy compared to the traditional RVA position. This potentially has important implications for the suitability of RVNA as an alternative site for ICD leads.


Europace | 2008

High-pressure balloon angioplasty of coronary sinus vein

K. Dauber; Gerry Kaye


Heart Lung and Circulation | 2015

The guidance of Cavo-Tricuspid Isthmus ablation using a contact force ablation catheter and novel parameters

C. Booth; Kevin Ng; K. Dauber; G. Kaye; Paul A. Gould


Heart Lung and Circulation | 2013

A Comparison of Right Ventricular Apical (RVA) and Non-Apical (RVNA) Defibrillator (ICD) Lead Position: A Single Centre Experience

L. Eng; Benjamin J. Hunt; K. Dauber; J. Hill; Paul A. Gould; G. Kaye


Journal of the American College of Cardiology | 2012

Optimization of cardiac resynchronization therapy at rest but not on exercise produces significant improvement in Bnp: Results of a 1 year randomized, double-blind clinical trial

Tony Stanton; Brian Haluska; K. Dauber; S. Doneva; W. Stafford; G. Kaye; Paul A. Gould; J. Hill; Thomas H. Marwick


Heart Lung and Circulation | 2012

Cardiac resynchronisation therapy optimisation at rest but not on exercise produces significant improvement in BNP: results of a one year randomised, double-blind clinical trial

Tony Stanton; Brian Haluska; K. Dauber; S. Doneva; W. Stafford; G. Kaye; Paul A. Gould; J. Hill; Thomas H. Marwick


Heart Lung and Circulation | 2009

Echocardiographic Optimization of Cardiac Resynchronization Therapy: The Importance of Mechanical Synchrony

Tony Stanton; Brian Haluska; Rodel Leano; K. Dauber; S. Doneva; W. Stafford; Paul A. Gould; G. Kaye; J. Hill; Thomas H. Marwick


Heart Lung and Circulation | 2009

Regional Variations Seen in Left Ventricular Electro-mechanical Activation

K. Dauber; Paul A. Gould; Carly Jenkins; S. Doneva; G. Kaye; J. Hill; Thomas H. Marwick

Collaboration


Dive into the K. Dauber's collaboration.

Top Co-Authors

Avatar

G. Kaye

Princess Alexandra Hospital

View shared research outputs
Top Co-Authors

Avatar

Paul A. Gould

Princess Alexandra Hospital

View shared research outputs
Top Co-Authors

Avatar

J. Hill

Princess Alexandra Hospital

View shared research outputs
Top Co-Authors

Avatar

Thomas H. Marwick

Baker IDI Heart and Diabetes Institute

View shared research outputs
Top Co-Authors

Avatar

S. Doneva

Princess Alexandra Hospital

View shared research outputs
Top Co-Authors

Avatar

Brian Haluska

University of Queensland

View shared research outputs
Top Co-Authors

Avatar

Tony Stanton

University of Queensland

View shared research outputs
Top Co-Authors

Avatar

W. Stafford

Memorial Hospital of South Bend

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

L. Hanekom

University of Queensland

View shared research outputs
Researchain Logo
Decentralizing Knowledge